stoop
MAP
LeaderboardAbout

1455 CLAY ST

Nob Hill · San Francisco, CA · Parcel 0219020 · Last violation Jul 22, 2026 · Last complaint Jul 23, 2026

NeighborhoodNob Hill
More violations than 100% of nearby buildings
More violations than 100% of buildings and more complaints than 100% of buildings in Nob Hill. Size-normalized against residential buildings in the neighborhood.
ViolationsComplaints
Activity TrendsLast 5 years
More activity recently than in past years
Last 2 yrs: 27 violations · 12 complaints
'24'26ViolationsComplaints
Severityⓘopen violations
All DBI violations have been resolved
Notices of Violation issued by the Department of Building Inspection, by current status.
Severe0
Serious0
Minor0

What to watch forⓘ

  1. Tenants here have reported no heat or no hot water.
    details ▸

    California law requires heating facilities in good working order, and plumbing facilities in good working order including hot and cold running water. A rental unit that substantially lacks either may be legally uninhabitable, which is the standard the implied warranty of habitability sets for every residential tenancy in the state.

    Ask how heat and hot water are supplied and who pays for them. If either fails once you live here, put the request to the landlord in writing and keep a copy.

    • California Tenant Guide
    • San Francisco Housing Code §701
  2. Unsafe work on paint has been reported here.
    Worth checkingⓘ
    Look for chipping or flaking paint, especially in older buildings and on window frames, door frames and stair rails, and for paint dust or debris left behind after recent work.
    details ▸

    San Francisco's Health Code presumes that any paint on a building built before 1979 is lead based unless shown otherwise, and treats lead hazards as a public health nuisance. Disturbing that paint without controlling the dust is what spreads the hazard. California law separately treats a lead hazard that endangers the occupants as a condition that can make a rental unit uninhabitable.

311 Housing Complaints
Total complaints since 2024
12
4 per year avg.↑ Rising — no prior history
Complaint severity
Last 5 years
12
Severeⓘ6
Seriousⓘ4
Minorⓘ2
Dept. of Building Inspection Violations
Total violations since 2001
104
4 per year avg.↑ Rising — no prior history
Open violations
0
No open DBI violations on record.

Top violation categories

5 yrsAll time
Fire safetyⓘ13 violations
Exterior & windowsⓘ10 violations
Floors & stairsⓘ7 violations
Peeling paintⓘ7 violations
Smoke detectorsⓘ7 violations
Walls, ceilings & cabinetsⓘ7 violations
Heat / hot waterⓘ5 violations
Gas shutoff & metersⓘ4 violations
Plumbingⓘ3 violations
Permits & unpermitted workⓘ2 violations
Pestsⓘ2 violations
Ventilation & lightⓘ2 violations
Electricalⓘ1 violations
General disrepairⓘ1 violations
Cleanliness & refuseⓘ1 violations
No specific condition stated32 violations
See violation log below.

Top complaint types

5 yrsAll time
Hide violations (104) ↑See complaints (12) →

Violation log

104 DBI violations

AllOpenClosed
StatusFiledCategoryItemNOV Item Description
not activeMay 25, 2016sanitation sectionprovide the services of a structural pest controller 1001b12, d, k sfhc
See something wrong? File a complaint with SF 311

Ask when the building was built and whether any paint work has been done recently. If it was built before 1978, read the federal booklet Protect Your Family From Lead in Your Home.

  • California Tenant Guide
  • San Francisco Health Code §581(b)(10)
  • Tenants here have reported mold.
    Worth checkingⓘ
    Look for dark spots on walls, floors and ceilings, and for dry or wet spots, flaking or bubbling, or a damp or moldy smell, especially in bathrooms and closets.
    details ▸

    San Francisco's Health Code treats visible or otherwise demonstrable mold or mildew in a residential building as a public health nuisance in its own right. Under state law, mold that the landlord has notice of and that affects livability or health can also breach the implied warranty of habitability.

    • California Tenant Guide
    • San Francisco Health Code §581(b)(6)
  • Doors Windows Broken Defective3 complaints
    Electrical Hazardous Condition2 complaints
    Electrical Non Hazard2 complaints
    Heat Lack Of Heat2 complaints
    Paint Lead Violating Safe Practices2 complaints
    Mold And Mildew1 complaints
    a number of rats were witnessed at inspection in and around the trash area. provide the services of a licensed pest control operator to eradicate the vermin. please note: according to state law it is unlawful for an unlicensed, uncertified person to apply pesticides to another person's dwelling unit. nor should anyone violate the epa labeling requirements. check for and repair contributing factors such as: a) plumbing leaks b) excessive garbage and trash c) excessive grease, grime and dirt d) holes, gaps and cracks in and around walls and kitchen and bathroom cabinets e) excessive personal belongings, not neatly stored notify the tenant 48 hours in advance of the treatment. notification must include the name of the products used and a phone number to call for information about those products. a referral will be made to the environmental health section of the department of public health (for apts. 415-252-3805). comply with the mice eradication protocol as directed by the environmental health section of the department of public health. fill all holes, gaps and cracks with solid material to eliminate the areas of intrusion. provide paper work from your exterminator at the time of re-inspection.
    not activeMay 25, 2016other sectioninspector commentsimportant note: due to the nature of this violation, this property has been defined as a nuisance per section 1001-d of the san francisco housing code. it is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection. please see the enclosed inspection appointment letter. you have been scheduled for a routine inspection of these premises on july 7, 2016 at 9:30 am along with the re-inspection of these items. all of the attached items should be completed and returned to the inspector at the time of inspection. a residential habitibility checklist has been included for your review.
    not activeMay 25, 2016fire sectionprovide carbon monoxide detectors 420 cbc provide smoke detectors 908, 911 sfhc, 907.2.11 sfbcprovide carbon monoxide detectors laid out per the san francisco building code section 420. there shall be one unit in each guest room within the immediate floor and each adjacent floor, above and below a gas burning appliance to include stoves, dryers, furnaces, water heaters and boilers. install smoke detectors as required by the san francisco building code. a self-certification form has been included for your convenience. provide completed form at inspection or return by mail to: department of building inspection housing division, c. grady 1660 mission street, 6th floor san francisco, ca 94102
    not activeSep 17, 2009building sectionthis notice includes violations for the areas noted.all common areas of 1455 clay street.
    not activeSep 17, 2009building sectionreplace broken glass window pane (1001(h),708 hc)in front of building second floor apartments and one on the third floor. three windows.
    not activeSep 17, 2009building sectionreplace window sash frame. (1001(h),708 hc)fourth floor apartment. front of building.
    not activeSep 17, 2009fire sectionrepair, maintain fire escape drop ladder in working condition (sec 908 hc) provide a written and signed report from a qualified service vendor or contractor stating that all parts and cables have been tested and are functional or you are required to lower the ladder on re-inspection day to verify its proper full release. lubricate and drop the ladder at least once a year.—
    not activeSep 17, 2009smoke detection sectionprovide annual certification for central alarm system / panel (908, 909 hc) the central alarm system must be tested and certified annually by a qualified professional vendor / electrical contractor. current certification must be visible and posted on the panel.—
    not activeSep 17, 2009fire sectionremove egress obstruction at (801,1001(l) hc)back stairs and fire escapes.
    not activeSep 17, 2009fire sectionpermanently remove combustible storage, cardboard, wood,motorcyle and parts, etc. (904, 1001(i) hc)from bottom of back stairs and area around garbage recptacles and back of building.
    not activeSep 17, 2009building sectionrepair handrails (802(c),1001(b)(13)hc)at exterior stairway, west side of building between second and third floor
    not activeSep 17, 2009building sectionrepair stairs (1001(b)(13)hc)repair damged and cracked treads, west side stairway between second and third floor.
    not activeSep 17, 2009security requirements sectionprovide primary locking devices at exterior doors (706 hc) note: door closer must be able to close and latch the door freely and without any assistance.at penthouse door leading to roof.
    not activeSep 17, 2009security requirements sectionprovide self-closing devices at exterior doors (706 hc) note: door closer must be able to close and latch the door freely and without any assistance.at penthouse door leading to roof.also repair self closing device leading to side back stairs on the second floor.
    not activeSep 17, 2009security requirements sectionreplace penthouse door with a one hour rated fire proof door.(807,707hc)—
    not activeSep 17, 2009other sectionprovide shutoff tool for gas utility shutoff (712 hc)at gas metered area.
    not activeSep 17, 2009other sectionpost enclosed gas meter instructional diagram in a public area. (712 hc)in lobby.
    not activeSep 17, 2009other sectioninspector commentsinspector comments regarding "follow up" reinspection: i have scheduled a reinspection of your building on friday, 16-october-2009 at 2:30 pm. reinspection of premise to include all areas referenced above. please contact inspector galvis to confirm appointment at 415-558-6513. it is the property owners responsibility to be present or direct his/her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector. on scheduled reinspection day, provide the inspector with a full access to all common and public areas per attached checklist. your cooperation is appreciated.
    not activeDec 4, 2002building sectionthis notice includes violations for the areas noted.1455 clay street, #1.
    not activeDec 4, 2002other sectionrepair damaged ceilings (1001b,h,o hc)at bathroom.
    not activeDec 4, 2002other sectionrepair source of water damage (703,1001f hc)at bathroom ceiling.
    not activeDec 4, 2002other sectionrepair floor covering (1001b,j,o hc)kitchen, near window and near refrigerator.
    not activeDec 4, 2002other sectionprovide heat to each occupied habitable room for 13 hrs between 5:00 a.m. and 11:00 a.m. and between 3:00 p.m. and 10:00 p.m. capable to maintaining a min. room temp. of 68 degrees f. (20 degrees c.). (701c hc)check radiators and repair/replace as necessary.
    not activeDec 4, 2002interior surfaces sectiondisturbing lead based paint can be extremely dangerous to dwelling occupants and visitors, particularly to young children, pregnant women, pets, and to people performing work on the premises. for interior or exterior paint removal : always wet the surface, contain and properly dispose of leaded paint. if you are unsure whether the paint is leaded, you should test it prior to performing any work. if the paint is found to contain lead, you should consult with an expert about appropriate procedures. proper containment and 3-day notification is required for exterior jobs of more than 10 sq.ft. (sec.3604, sfbc) informational packets are available at (415) 558-6088. you can contact the san francisco childhood lead poisoning prevention program at: (415) 554-8930 for free advice. if you cause lead dust to be created, you could be liable for any illness caused by the dust. ordinance #446-97.—
    not activeDec 4, 2002interior surfaces sectionpaint ceilings (1001b,1301 hc)after repairs are done.
    not activeNov 1, 2002building sectionthis notice includes violations for the areas noted.1455 clay street.
    not activeNov 1, 2002interior surfaces sectionrepair damaged ceilings (1001b,h,o hc)#12, bedroom and living room.
    not activeNov 1, 2002interior surfaces sectionrepair damaged walls (1001b,h,o hc)#12, bedroom, near ceiling.
    not activeNov 1, 2002interior surfaces sectionpaint ceilings (1001b,1301 hc)after repairs are done.
    not activeNov 1, 2002interior surfaces sectionpaint walls (1001b,1301 hc)after repairs are done.
    not activeNov 1, 2002other sectionrepair floor covering (1001b,j,o hc)#12, under and around radiator. repair/replace damaged carpets on stairways.
    not activeNov 1, 2002other sectionmiscellaneous violationsrepair damaged radiator in unit #12 and where required.
    not activeNov 1, 2002other sectionprovide heat to each occupied habitable room for 13 hrs between 5:00 a.m. and 11:00 a.m. and between 3:00 p.m. and 10:00 p.m. capable to maintaining a min. room temp. of 68 degrees f. (20 degrees c.). (701c hc)open all units for inspection of heat availability at time of inspection. please notify all tenants at least 24 hours prior to entering their units for maintenance purposes. open boiler room for inspection at time of reinspection.
    not activeNov 1, 2002smoke detection sectionprovide smoke detector (908,911 hc)in unit #12 and where required.
    not activeNov 1, 2002fire sectionremove egress obstruction at (801,1001(l) hc)exterior stairways.
    not activeNov 1, 2002fire sectionmaintain fire escape drop ladders in good working condition (sec 908 hc)note: property manager, owner or the owner's agent needs to provide a proof of the workability of the fire escape ladders. non-working fire escape drop ladder is a life safety hazard and must be corrected immediately. provide a written report from a qualified service company or contractor stating that all parts and cables have been tested and are functional or contact the housing inspector (within 30 days) to witness lowering the ladder in person. reminder: test and verify that all windows or doors leading to emergency fire escape are operational and unobstructed. advise tenants not to block the path of emergency exits on the inside.
    not activeNov 1, 2002other sectioninspector commentsnote: the department of building inspection urges all owners of property with exterior stairs, decks and attachments to have a licensed professional pest control contractor, general building contractor, architect or engineer inspect your deck, porch, stairs, balcony or other attachments, every 2 years to assure their continued stability and safety. have them provide a written report stating recommended repairs.
    not activeNov 1, 2002interior surfaces sectiondisturbing lead based paint can be extremely dangerous to dwelling occupants and visitors, particularly to young children, pregnant women, pets, and to people performing work on the premises. for interior or exterior paint removal : always wet the surface, contain and properly dispose of leaded paint. if you are unsure whether the paint is leaded, you should test it prior to performing any work. if the paint is found to contain lead, you should consult with an expert about appropriate procedures. proper containment and 3-day notification is required for exterior jobs of more than 10 sq.ft. (sec.3604, sfbc) informational packets are available at (415) 558-6088. you can contact the san francisco childhood lead poisoning prevention program at: (415) 554-8930 for free advice. if you cause lead dust to be created, you could be liable for any illness caused by the dust. ordinance #446-97.—
    not activeJan 17, 2002building sectionthis notice includes violations for the areas noted.1455 clay street #1 and common areas.
    not activeJan 17, 2002interior surfaces sectionrepair damaged walls and ceilings (1001b,h,o hc)#1''s bathroom, living room, bed room and hallway.
    not activeJan 17, 2002interior surfaces sectiondisturbing lead based paint can be extremely dangerous to dwelling occupants and visitors, particularly to young children, pregnant women, pets, and to people performing work on the premises. for interior or exterior paint removal : always wet the surface, contain and properly dispose of leaded paint. if you are unsure whether the paint is leaded, you should test it prior to performing any work. if the paint is found to contain lead, you should consult with an expert about appropriate procedures. proper containment and 3-day notification is required for exterior jobs of more than 10 sq.ft. (sec.3604, sfbc) informational packets are available at (415) 558-6088. you can contact the san francisco childhood lead poisoning prevention program at: (415) 554-8930 for free advice. if you cause lead dust to be created, you could be liable for any illness caused by the dust. ordinance #446-97.—
    not activeJan 17, 2002interior surfaces sectionpaint walls and ceilings (1001b,1301 hc)after repairs are done.
    not activeJan 17, 2002interior surfaces sectionother interior violationsreplace broken glass at garage door.
    not activeJan 17, 2002other sectionprovide heat to each occupied habitable room for 13 hrs between 5:00 a.m. and 11:00 a.m. and between 3:00 p.m. and 10:00 p.m. capable to maintaining a min. room temp. of 68 degrees f. (20 degrees c.). (701c hc)open boiler room for inspection at time of reinspection. set time clock to appropriate hours. post boiler permit in boiler area.
    not activeJan 17, 2002plumbing and electrical sectionprovide non-tamperable temp.-sensing device with a + to -1 1/2 degree f. (.8 degrees c.) tol., centrally located in bldg in habitable rm (not mgr or owner's) to which heat is provided, occupied or not (701c hc)show location at time of reinspection.
    not activeJan 17, 2002plumbing and electrical sectionprovide electrical permit (90.25 ec)at time of reinspection, show copy of electrical permit required for the electrical heaters being installed.
    not activeJan 17, 2002interior surfaces sectionrepair floor covering (1001b,j,o hc)in #1's kitchen -tripping hazard.
    not activeFeb 21, 2001building sectionthis notice includes violations for the areas noted.1455 clay st.
    not activeFeb 21, 2001fire sectionrecharge/date tag fire extinguisher type 2a 10bc or equivalent (905,1001(m)hc)all expired fire extinguisher in the building.
    not activeFeb 21, 2001fire sectionremove egress obstruction at (801,1001(l) hc)remove all items off of the rear stair and fire escape and roof, so as not to obstruct the means of egress
    not activeMay 25, 2016
    sanitation section · provide the services of a structural pest controller 1001b12, d, k sfhc
    a number of rats were witnessed at inspection in and around the trash area. provide the services of a licensed pest control operator to eradicate the vermin. please note: according to state law it is unlawful for an unlicensed, uncertified person to apply pesticides to another person's dwelling unit. nor should anyone violate the epa labeling requirements. check for and repair contributing factors such as: a) plumbing leaks b) excessive garbage and trash c) excessive grease, grime and dirt d) holes, gaps and cracks in and around walls and kitchen and bathroom cabinets e) excessive personal belongings, not neatly stored notify the tenant 48 hours in advance of the treatment. notification must include the name of the products used and a phone number to call for information about those products. a referral will be made to the environmental health section of the department of public health (for apts. 415-252-3805). comply with the mice eradication protocol as directed by the environmental health section of the department of public health. fill all holes, gaps and cracks with solid material to eliminate the areas of intrusion. provide paper work from your exterminator at the time of re-inspection.
    not activeMay 25, 2016
    other section · inspector comments
    important note: due to the nature of this violation, this property has been defined as a nuisance per section 1001-d of the san francisco housing code. it is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection. please see the enclosed inspection appointment letter. you have been scheduled for a routine inspection of these premises on july 7, 2016 at 9:30 am along with the re-inspection of these items. all of the attached items should be completed and returned to the inspector at the time of inspection. a residential habitibility checklist has been included for your review.
    not activeMay 25, 2016
    fire section · provide carbon monoxide detectors 420 cbc provide smoke detectors 908, 911 sfhc, 907.2.11 sfbc
    provide carbon monoxide detectors laid out per the san francisco building code section 420. there shall be one unit in each guest room within the immediate floor and each adjacent floor, above and below a gas burning appliance to include stoves, dryers, furnaces, water heaters and boilers. install smoke detectors as required by the san francisco building code. a self-certification form has been included for your convenience. provide completed form at inspection or return by mail to: department of building inspection housing division, c. grady 1660 mission street, 6th floor san francisco, ca 94102
    not activeSep 17, 2009
    building section · this notice includes violations for the areas noted.
    all common areas of 1455 clay street.
    not activeSep 17, 2009
    building section · replace broken glass window pane (1001(h),708 hc)
    in front of building second floor apartments and one on the third floor. three windows.
    not activeSep 17, 2009
    building section · replace window sash frame. (1001(h),708 hc)
    fourth floor apartment. front of building.
    not activeSep 17, 2009
    fire section · repair, maintain fire escape drop ladder in working condition (sec 908 hc) provide a written and signed report from a qualified service vendor or contractor stating that all parts and cables have been tested and are functional or you are required to lower the ladder on re-inspection day to verify its proper full release. lubricate and drop the ladder at least once a year.
    not activeSep 17, 2009
    smoke detection section · provide annual certification for central alarm system / panel (908, 909 hc) the central alarm system must be tested and certified annually by a qualified professional vendor / electrical contractor. current certification must be visible and posted on the panel.
    not activeSep 17, 2009
    fire section · remove egress obstruction at (801,1001(l) hc)
    back stairs and fire escapes.
    not activeSep 17, 2009
    fire section · permanently remove combustible storage, cardboard, wood,motorcyle and parts, etc. (904, 1001(i) hc)
    from bottom of back stairs and area around garbage recptacles and back of building.
    not activeSep 17, 2009
    building section · repair handrails (802(c),1001(b)(13)hc)
    at exterior stairway, west side of building between second and third floor
    not activeSep 17, 2009
    building section · repair stairs (1001(b)(13)hc)
    repair damged and cracked treads, west side stairway between second and third floor.
    not activeSep 17, 2009
    security requirements section · provide primary locking devices at exterior doors (706 hc) note: door closer must be able to close and latch the door freely and without any assistance.
    at penthouse door leading to roof.
    not activeSep 17, 2009
    security requirements section · provide self-closing devices at exterior doors (706 hc) note: door closer must be able to close and latch the door freely and without any assistance.
    at penthouse door leading to roof.also repair self closing device leading to side back stairs on the second floor.
    not activeSep 17, 2009
    security requirements section · replace penthouse door with a one hour rated fire proof door.(807,707hc)
    not activeSep 17, 2009
    other section · provide shutoff tool for gas utility shutoff (712 hc)
    at gas metered area.
    not activeSep 17, 2009
    other section · post enclosed gas meter instructional diagram in a public area. (712 hc)
    in lobby.
    not activeSep 17, 2009
    other section · inspector comments
    inspector comments regarding "follow up" reinspection: i have scheduled a reinspection of your building on friday, 16-october-2009 at 2:30 pm. reinspection of premise to include all areas referenced above. please contact inspector galvis to confirm appointment at 415-558-6513. it is the property owners responsibility to be present or direct his/her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector. on scheduled reinspection day, provide the inspector with a full access to all common and public areas per attached checklist. your cooperation is appreciated.
    not activeDec 4, 2002
    building section · this notice includes violations for the areas noted.
    1455 clay street, #1.
    not activeDec 4, 2002
    other section · repair damaged ceilings (1001b,h,o hc)
    at bathroom.
    not activeDec 4, 2002
    other section · repair source of water damage (703,1001f hc)
    at bathroom ceiling.
    not activeDec 4, 2002
    other section · repair floor covering (1001b,j,o hc)
    kitchen, near window and near refrigerator.
    not activeDec 4, 2002
    other section · provide heat to each occupied habitable room for 13 hrs between 5:00 a.m. and 11:00 a.m. and between 3:00 p.m. and 10:00 p.m. capable to maintaining a min. room temp. of 68 degrees f. (20 degrees c.). (701c hc)
    check radiators and repair/replace as necessary.
    not activeDec 4, 2002
    interior surfaces section · disturbing lead based paint can be extremely dangerous to dwelling occupants and visitors, particularly to young children, pregnant women, pets, and to people performing work on the premises. for interior or exterior paint removal : always wet the surface, contain and properly dispose of leaded paint. if you are unsure whether the paint is leaded, you should test it prior to performing any work. if the paint is found to contain lead, you should consult with an expert about appropriate procedures. proper containment and 3-day notification is required for exterior jobs of more than 10 sq.ft. (sec.3604, sfbc) informational packets are available at (415) 558-6088. you can contact the san francisco childhood lead poisoning prevention program at: (415) 554-8930 for free advice. if you cause lead dust to be created, you could be liable for any illness caused by the dust. ordinance #446-97.
    not activeDec 4, 2002
    interior surfaces section · paint ceilings (1001b,1301 hc)
    after repairs are done.
    not activeNov 1, 2002
    building section · this notice includes violations for the areas noted.
    1455 clay street.
    not activeNov 1, 2002
    interior surfaces section · repair damaged ceilings (1001b,h,o hc)
    #12, bedroom and living room.
    not activeNov 1, 2002
    interior surfaces section · repair damaged walls (1001b,h,o hc)
    #12, bedroom, near ceiling.
    not activeNov 1, 2002
    interior surfaces section · paint ceilings (1001b,1301 hc)
    after repairs are done.
    not activeNov 1, 2002
    interior surfaces section · paint walls (1001b,1301 hc)
    after repairs are done.
    not activeNov 1, 2002
    other section · repair floor covering (1001b,j,o hc)
    #12, under and around radiator. repair/replace damaged carpets on stairways.
    not activeNov 1, 2002
    other section · miscellaneous violations
    repair damaged radiator in unit #12 and where required.
    not activeNov 1, 2002
    other section · provide heat to each occupied habitable room for 13 hrs between 5:00 a.m. and 11:00 a.m. and between 3:00 p.m. and 10:00 p.m. capable to maintaining a min. room temp. of 68 degrees f. (20 degrees c.). (701c hc)
    open all units for inspection of heat availability at time of inspection. please notify all tenants at least 24 hours prior to entering their units for maintenance purposes. open boiler room for inspection at time of reinspection.
    not activeNov 1, 2002
    smoke detection section · provide smoke detector (908,911 hc)
    in unit #12 and where required.
    not activeNov 1, 2002
    fire section · remove egress obstruction at (801,1001(l) hc)
    exterior stairways.
    not activeNov 1, 2002
    fire section · maintain fire escape drop ladders in good working condition (sec 908 hc)
    note: property manager, owner or the owner's agent needs to provide a proof of the workability of the fire escape ladders. non-working fire escape drop ladder is a life safety hazard and must be corrected immediately. provide a written report from a qualified service company or contractor stating that all parts and cables have been tested and are functional or contact the housing inspector (within 30 days) to witness lowering the ladder in person. reminder: test and verify that all windows or doors leading to emergency fire escape are operational and unobstructed. advise tenants not to block the path of emergency exits on the inside.
    not activeNov 1, 2002
    other section · inspector comments
    note: the department of building inspection urges all owners of property with exterior stairs, decks and attachments to have a licensed professional pest control contractor, general building contractor, architect or engineer inspect your deck, porch, stairs, balcony or other attachments, every 2 years to assure their continued stability and safety. have them provide a written report stating recommended repairs.
    not activeNov 1, 2002
    interior surfaces section · disturbing lead based paint can be extremely dangerous to dwelling occupants and visitors, particularly to young children, pregnant women, pets, and to people performing work on the premises. for interior or exterior paint removal : always wet the surface, contain and properly dispose of leaded paint. if you are unsure whether the paint is leaded, you should test it prior to performing any work. if the paint is found to contain lead, you should consult with an expert about appropriate procedures. proper containment and 3-day notification is required for exterior jobs of more than 10 sq.ft. (sec.3604, sfbc) informational packets are available at (415) 558-6088. you can contact the san francisco childhood lead poisoning prevention program at: (415) 554-8930 for free advice. if you cause lead dust to be created, you could be liable for any illness caused by the dust. ordinance #446-97.
    not activeJan 17, 2002
    building section · this notice includes violations for the areas noted.
    1455 clay street #1 and common areas.
    not activeJan 17, 2002
    interior surfaces section · repair damaged walls and ceilings (1001b,h,o hc)
    #1''s bathroom, living room, bed room and hallway.
    not activeJan 17, 2002
    interior surfaces section · disturbing lead based paint can be extremely dangerous to dwelling occupants and visitors, particularly to young children, pregnant women, pets, and to people performing work on the premises. for interior or exterior paint removal : always wet the surface, contain and properly dispose of leaded paint. if you are unsure whether the paint is leaded, you should test it prior to performing any work. if the paint is found to contain lead, you should consult with an expert about appropriate procedures. proper containment and 3-day notification is required for exterior jobs of more than 10 sq.ft. (sec.3604, sfbc) informational packets are available at (415) 558-6088. you can contact the san francisco childhood lead poisoning prevention program at: (415) 554-8930 for free advice. if you cause lead dust to be created, you could be liable for any illness caused by the dust. ordinance #446-97.
    not activeJan 17, 2002
    interior surfaces section · paint walls and ceilings (1001b,1301 hc)
    after repairs are done.
    not activeJan 17, 2002
    interior surfaces section · other interior violations
    replace broken glass at garage door.
    not activeJan 17, 2002
    other section · provide heat to each occupied habitable room for 13 hrs between 5:00 a.m. and 11:00 a.m. and between 3:00 p.m. and 10:00 p.m. capable to maintaining a min. room temp. of 68 degrees f. (20 degrees c.). (701c hc)
    open boiler room for inspection at time of reinspection. set time clock to appropriate hours. post boiler permit in boiler area.
    not activeJan 17, 2002
    plumbing and electrical section · provide non-tamperable temp.-sensing device with a + to -1 1/2 degree f. (.8 degrees c.) tol., centrally located in bldg in habitable rm (not mgr or owner's) to which heat is provided, occupied or not (701c hc)
    show location at time of reinspection.
    not activeJan 17, 2002
    plumbing and electrical section · provide electrical permit (90.25 ec)
    at time of reinspection, show copy of electrical permit required for the electrical heaters being installed.
    not activeJan 17, 2002
    interior surfaces section · repair floor covering (1001b,j,o hc)
    in #1's kitchen -tripping hazard.
    not activeFeb 21, 2001
    building section · this notice includes violations for the areas noted.
    1455 clay st.
    not activeFeb 21, 2001
    fire section · recharge/date tag fire extinguisher type 2a 10bc or equivalent (905,1001(m)hc)
    all expired fire extinguisher in the building.
    not activeFeb 21, 2001
    fire section · remove egress obstruction at (801,1001(l) hc)
    remove all items off of the rear stair and fire escape and roof, so as not to obstruct the means of egress
    Page 2 of 3
    ← PrevNext →