stoop
MAP
LeaderboardAbout
Building SafetyHousing Conditions

400 HERKIMER STREET

Brooklyn · ZIP 11213 · BIN 3054043 · Bedford-Stuyvesant (East) · Last violation Jul 22, 2026 · Last complaint Jun 4, 2026

NeighborhoodBedford-Stuyvesant (East)
More violations than 88% of nearby buildings
More violations than 88% of buildings and more complaints than 97% of buildings in Bedford-Stuyvesant (East). Size-normalized against residential buildings in the neighborhood for issues in the last 10 years.
ViolationsComplaints
Activity TrendsLast 5 years
A steady level of activity over time
Last 2 yrs: 213 violations · 1011 complaints
'21'26ViolationsComplaints
▼ View all activity over time
Severityⓘopen violations
65 immediately hazardous (Class C) violations still open
Class C violations include lead paint, mold, pest infestations, heat/hot water failure, and structural hazards — the most serious category.
Class Cimmediately hazardous65Class Bhazardous136

What to watch forⓘ

  1. Hazardous violations are open, including mold and pests, heat and hot water, and fire safety.
    Worth checking · AI-assistedⓘ
    Look under sinks and inside cabinets for droppings or signs of rodents or cockroaches. Feel the radiator or baseboard heater with your hand to check if it produces heat. Look at stairwells and hallways for blocked doors, clutter blocking passage, or fire escape windows painted shut.
    details ▸

    Deadlines vary by condition: immediate for heat and hot water, 14 days for self-closing doors, 21 days for lead paint, window guards, mold, and mice, cockroaches or rats, and 24 hours for everything else. They run from the date the owner is served, and mark when civil penalties can be sought in Housing Court. They are not a promise the condition is fixed by then. If the owner does not fix it, HPD can send its own contractor and bill them.

    • —Mold & pests — Rodent, cockroach, bedbug, or other pest infestation and extermination related issues.
    • —Heat / hot water — Lack of heat, hot water, or heating system related issues affecting tenants.
    • —
Housing Preservation & Development Violations
Total violations since 1990
972
26 per year avg.↓ Down 26% in the last 2 years (213 vs 287 prior 2 yrs)
Open violations
242
Class C (immed. haz.)ⓘ65
Class B (hazardous)ⓘ136
Rent-impairingⓘ27
Housing Preservation & Development Complaints
Total complaints since 2003
4,009
167 per year avg.↑ Up 53% in the last 2 years (1,011 vs 659 prior 2 yrs)
Complaint Resolution
No access9%Violation issued12%No violation21%Phone resolved58%Other0%(4,009)
Urgency breakdown
Last 12 mo.

Top violation categories

5 yrsAll time
Maintenanceⓘ257 violations
Egressⓘ159 violations
Heat And Hot Waterⓘ83 violations
Extermination & Rodent Eradicationⓘ74 violations
Smoke Detecting Devicesⓘ65 violations
Paintingⓘ63 violations
Carbon Monoxide Detecting Devicesⓘ55 violations
Water Supplyⓘ55 violations
Top complaint groupsⓘ
5 yrsAll time
Heat / hot waterⓘ2,483 complaints
Bldg maintenanceⓘ356 complaints
Mold & pestsⓘ285 complaints
Water & plumbingⓘ281 complaints
Electricalⓘ142 complaints
Appliancesⓘ132 complaints
Safety & fireⓘ76 complaints
Elevatorⓘ9 complaints
Adminⓘ4 complaints
Outdoor / structuralⓘ2 complaints
See violations →See complaints →
See something wrong? File a complaint with 311
Safety & fire — Blocked, unsafe, or inaccessible exits, hallways, stairs, or fire escape routes.

The violation list below shows which conditions are open and when each was cited. If one in your own apartment is still unaddressed, call 311.

  • NYC HPD, ABCs of Housing 2024 (Tenants' Guide) — violation classes
  • NYC HPD, Penalties and Fees — correction deadlines
  • Detector violations on record.
    Worth checking · AI-assistedⓘ
    Locate smoke detectors on the ceiling near bedrooms and in hallways, and ask the broker whether carbon monoxide detectors are present in the unit.
    details ▸

    Responsibility is split: the owner provides, installs, and replaces the detectors, while the tenant tests them monthly and replaces the batteries. An open violation means the owner has not yet certified to HPD that the condition was fixed, so a device may still be missing or dead at move-in. A tenant reimburses the owner for a newly installed device, $25 for a smoke or carbon monoxide detector and $50 for a combined unit, and is responsible for replacing one that goes missing or is damaged during the tenancy.

    On a viewing, look for a smoke alarm within fifteen feet of the door of each room used for sleeping, on the ceiling or just below it on the wall, and a carbon monoxide alarm at any height, including one plugged into a hallway outlet. Press the test button, and check that none have been painted over. A chirping alarm usually means a low battery, which is the tenant's to replace, but detectors also sound a separate end-of-life alarm when the device itself has to be replaced by the owner.

    • NYC HPD, ABCs of Housing 2024 (Tenants' Guide) — the requirement
    • NYC HPD, Smoke, Carbon Monoxide, and Natural Gas Detectors — responsibilities, placement, and reimbursement
  • Open violation ages
    ▪ < 30 days2% (4)
    ▪ 30–90 days1% (2)
    ▪ 3–12 months19% (47)
    ▪ 1–3 years39% (94)
    ▪ 3+ years39% (95)
    Prior 4 yr.
    Immed. Emergency1%5%
    Emergency97%83%
    Non-Emergency2%12%
    (322)
    (1,610)