2 BUCARELI DR

Lakeshore · San Francisco, CA · Parcel 7335001 · Last violation Jul 28, 2026 · Last complaint Aug 4, 2026

NeighborhoodLakeshore
More violations than 99% of nearby buildings
More violations than 99% of buildings and more complaints than 97% of buildings in Lakeshore. Size-normalized against residential buildings in the neighborhood.
ViolationsComplaints
Activity TrendsLast 5 years
More activity recently than in past years
Last 2 yrs: 152 violations · 42 complaints
'21'26ViolationsComplaints
Severityⓘopen violations
3 open fire-safety violations
Active Notices of Violation issued by the Department of Building Inspection.
Severe3
Serious104
Minor10
311 Housing Complaints
Total complaints since 2011
96
6 per year avg.↑ Up 500% in the last 2 years (42 vs 7 prior 2 yrs)
Complaint severity
Last 5 years
51
Severeⓘ26
Seriousⓘ17
Minorⓘ8
Dept. of Building Inspection Violations
Total violations since 1996
462
15 per year avg.↑ Up 361% in the last 2 years (152 vs 33 prior 2 yrs)
Open violations
117
Severeⓘ3
Seriousⓘ104
Minorⓘ10

Top violation categories

5 yrsAll time
building sectionⓘ165 violations
other sectionⓘ13 violations
interior surfaces section5 violations
Unknownⓘ4 violations
plumbing and electrical sectionⓘ4 violations
fire sectionⓘ3 violations

Top complaint types

5 yrsAll time
Heat Lack Of Heat13 complaints
Elevators No Working Elevator 7 Or More Stories11 complaints
Infestation Rodent Insect5 complaints
Mold And Mildew5 complaints
General Maintenance Not In List Above5 complaints
Plumbing Broken Leaking5 complaints
Electrical Non Hazard1 complaints
Ventilation Inadequate Or None1 complaints
Elevators Everthing Else1 complaints
Fire Alarm System1 complaints
Garbage Receptacles1 complaints
Hot Water Lack Of Hot Water1 complaints
Paint Peeling1 complaints
Hide violations (462) ↑See complaints (96) →

Violation log

117 DBI violations · Open

AllOpenClosed
StatusFiledCategoryItemNOV Item Description
OpenApr 21, 2025other sectioninspector commentsthe tenant stated that heat was not in opearation for some time but it is currenly in working order. the complaint cited non working elevators at the 12 story building. at the time of inspection it was noted that there is a three elevator bank. one elevator has been permanenly taken out of service and the doors are sealed shut. a second elevator is currently of of order. currently there is one working elevator. although 2 elevators are inoperative the sfhc allows to have a working elevator.
See something wrong? File a complaint with SF 311
OpenApr 21, 2025fire sectionrepair smoke enclosure door closer (807,707 hc)repair or replace the closing device at the trash room door labeled #17.
OpenApr 21, 2025fire sectionfire alarm maintenance (909(d) hc (907.20.5) sffcat the time of inspection a trouble light was noted on the central alarm panel. perform the required repairs and restore proper operation to the central alarm. have the system inspected and tested as required and certification must be current and posted.
OpenApr 21, 2025other sectiongeneral dilapidation or improper maintenance 1001(b)(d)(13) hca. remount and secure the clothes drying rack is the basement laundry room. b. replace the missing cover at the area floor drain. c. replace the missing grate covers at the exterior ramp channel drain.
OpenApr 21, 2025building sectionthis notice includes violations for the areas noted.810 gonzalez dr. common area and unit 10g.
OpenApr 21, 2025fire sectionremove egress obstruction (801,1001(l) hc)remove the mattress from the common hallway by the exit doors on the 10th floor and maintain unobstructed egress.
OpenApr 21, 2025other sectioninspector comments(nuisance (401(2) (1001(d) hc) this property has been deemed a nuisance. it is the property owner's responsibility to be present or to direct his/her representative to attend the reinspections scheduled on this notice of violation, for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibilty to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954. san francisco housing code section 303.(b), if any dwelling, apartment units or guest rooms are to be accessed during the reinspection.
OpenDec 18, 2024building sectionrepair the water damaged hardwood flooring (1001(b)(13), 1001(j)hc)in the bedroom by the window.
OpenDec 18, 2024building sectionthis notice includes violations for the areas noted.these violations are in unit# 403 font blvd of the building.
OpenDec 18, 2024building sectionrepair then re-paint water damaged ceiling and wall (1001(b)(13), 1301 hc) note: check for water intrusion and repair as necessary.in the following areas: 1) bedroom wall by the window. 2) bathroom ceiling.
OpenDec 18, 2024building sectioninspector commentsit is the property owner's responsibility to be present or direct his/her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner can not attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the reinspection.
OpenSep 3, 2024other sectioninspector commentsrepairs cited in this notice may require building, plumbing and/or electrical permits. it is the responsibility of the owner to obtain (or have others obtain) any required permits before beginning work that requires permit(s). specify in the permit description of work the complaint number and the items that need a permit. this case can not be abated until the housing inspector makes a final inspection to verify that all violations have been corrected and all required permits have been obtained and finalized. on the reinspection day, present to the housing inspector the job card, permit appication and permits indicating that all the required work under permit is complete. prior to the reinspection by the housing inspector, call building, electrical and/or plumbing inspector(s) for the required inspection(s).
OpenSep 3, 2024building sectionprovide ventilation for habitable rooms (504(a), 1001(b)(7),(8) hc)a. the roof top exhaust fan is damaged and the motor is exposed to the weather. repair or replace the exhaust fan. b. replace all corroded exhaust caps visible on the roof.
OpenSep 3, 2024plumbing and electrical sectionrepair drain (1001f hc)replace the missing area floor drain cover in the basement by room 16.
OpenSep 3, 2024building sectiongeneral dilapidation or improper maintenance 1001(b)(d)(13) hcrepair or replace the corroded garbage receptacle by the rear exit doorway.
OpenSep 3, 2024building sectionthis notice includes violations for the areas noted.810 gonzalez dr. common area.
OpenSep 3, 2024other sectioninspector comments(nuisance (401(2) (1001(d) hc) this property has been deemed a nuisance. it is the property owner's responsibility to be present or to direct his/her representative to attend the reinspections scheduled on this notice of violation, for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibilty to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954. san francisco housing code section 303.(b), if any dwelling, apartment units or guest rooms are to be accessed during the reinspection.
OpenApr 21, 2025
other section · inspector comments
the tenant stated that heat was not in opearation for some time but it is currenly in working order. the complaint cited non working elevators at the 12 story building. at the time of inspection it was noted that there is a three elevator bank. one elevator has been permanenly taken out of service and the doors are sealed shut. a second elevator is currently of of order. currently there is one working elevator. although 2 elevators are inoperative the sfhc allows to have a working elevator.
OpenApr 21, 2025
fire section · repair smoke enclosure door closer (807,707 hc)
repair or replace the closing device at the trash room door labeled #17.
OpenApr 21, 2025
fire section · fire alarm maintenance (909(d) hc (907.20.5) sffc
at the time of inspection a trouble light was noted on the central alarm panel. perform the required repairs and restore proper operation to the central alarm. have the system inspected and tested as required and certification must be current and posted.
OpenApr 21, 2025
other section · general dilapidation or improper maintenance 1001(b)(d)(13) hc
a. remount and secure the clothes drying rack is the basement laundry room. b. replace the missing cover at the area floor drain. c. replace the missing grate covers at the exterior ramp channel drain.
OpenApr 21, 2025
building section · this notice includes violations for the areas noted.
810 gonzalez dr. common area and unit 10g.
OpenApr 21, 2025
fire section · remove egress obstruction (801,1001(l) hc)
remove the mattress from the common hallway by the exit doors on the 10th floor and maintain unobstructed egress.
OpenApr 21, 2025
other section · inspector comments
(nuisance (401(2) (1001(d) hc) this property has been deemed a nuisance. it is the property owner's responsibility to be present or to direct his/her representative to attend the reinspections scheduled on this notice of violation, for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibilty to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954. san francisco housing code section 303.(b), if any dwelling, apartment units or guest rooms are to be accessed during the reinspection.
OpenDec 18, 2024
building section · repair the water damaged hardwood flooring (1001(b)(13), 1001(j)hc)
in the bedroom by the window.
OpenDec 18, 2024
building section · this notice includes violations for the areas noted.
these violations are in unit# 403 font blvd of the building.
OpenDec 18, 2024
building section · repair then re-paint water damaged ceiling and wall (1001(b)(13), 1301 hc) note: check for water intrusion and repair as necessary.
in the following areas: 1) bedroom wall by the window. 2) bathroom ceiling.
OpenDec 18, 2024
building section · inspector comments
it is the property owner's responsibility to be present or direct his/her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner can not attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the reinspection.
OpenSep 3, 2024
other section · inspector comments
repairs cited in this notice may require building, plumbing and/or electrical permits. it is the responsibility of the owner to obtain (or have others obtain) any required permits before beginning work that requires permit(s). specify in the permit description of work the complaint number and the items that need a permit. this case can not be abated until the housing inspector makes a final inspection to verify that all violations have been corrected and all required permits have been obtained and finalized. on the reinspection day, present to the housing inspector the job card, permit appication and permits indicating that all the required work under permit is complete. prior to the reinspection by the housing inspector, call building, electrical and/or plumbing inspector(s) for the required inspection(s).
OpenSep 3, 2024
building section · provide ventilation for habitable rooms (504(a), 1001(b)(7),(8) hc)
a. the roof top exhaust fan is damaged and the motor is exposed to the weather. repair or replace the exhaust fan. b. replace all corroded exhaust caps visible on the roof.
OpenSep 3, 2024
plumbing and electrical section · repair drain (1001f hc)
replace the missing area floor drain cover in the basement by room 16.
OpenSep 3, 2024
building section · general dilapidation or improper maintenance 1001(b)(d)(13) hc
repair or replace the corroded garbage receptacle by the rear exit doorway.
OpenSep 3, 2024
building section · this notice includes violations for the areas noted.
810 gonzalez dr. common area.
OpenSep 3, 2024
other section · inspector comments
(nuisance (401(2) (1001(d) hc) this property has been deemed a nuisance. it is the property owner's responsibility to be present or to direct his/her representative to attend the reinspections scheduled on this notice of violation, for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibilty to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954. san francisco housing code section 303.(b), if any dwelling, apartment units or guest rooms are to be accessed during the reinspection.