1010 BUCHANAN ST

Western Addition · San Francisco, CA · Parcel 0771025 · Last violation Oct 2, 2025 · Last complaint Sep 29, 2026

NeighborhoodWestern Addition
More violations than 96% of nearby buildings
More violations than 96% of buildings and more complaints than 94% of buildings in Western Addition. Size-normalized against residential buildings in the neighborhood.
ViolationsComplaints
Activity TrendsLast 5 years
A steady level of activity over time
Last 2 yrs: 15 violations · 19 complaints
'21'26ViolationsComplaints
Severityⓘopen violations
15 open DBI violations
Active Notices of Violation issued by the Department of Building Inspection.
Severe0
Serious10
Minor5

What to watch forⓘ

  1. Fire safety problems have been reported here.
    Worth checkingⓘ
    Walk the exit route from the unit to the street and check the stairs and hallways are clear of stored items, and that fire doors close properly.
    details ▸

    California law requires safe fire or emergency exits leading to a street or hallway, and requires stairs, hallways and exits to be kept litter free. Storage areas, garages and basements must be kept free of combustible materials. San Francisco's Housing Code separately treats inadequate exits and inadequate fire protection equipment as conditions that make a building substandard, which is the finding behind a notice of violation.

    • California Tenant Guide
    • San Francisco Housing Code §1001(m), (n)
  2. Tenants here have reported no heat or no hot water.
    details ▸

    California law requires heating facilities in good working order, and plumbing facilities in good working order including hot and cold running water. A rental unit that substantially lacks either may be legally uninhabitable, which is the standard the implied warranty of habitability sets for every residential tenancy in the state.

311 Housing Complaints
Total complaints since 2016
26
2 per year avg.↑ Up 375% in the last 2 years (19 vs 4 prior 2 yrs)
Complaint severity
Last 5 years
24
Severeⓘ8
Seriousⓘ8
Minorⓘ8
Dept. of Building Inspection Violations
Total violations since 2002
154
6 per year avg.↑ Up 200% in the last 2 years (15 vs 5 prior 2 yrs)
Open violations
15
Severeⓘ0
Seriousⓘ10
Minorⓘ5

Top violation categories

5 yrsAll time
Heating equipmentⓘ7 violations
Plumbingⓘ2 violations
Heat / hot waterⓘ1 violations
Fire safetyⓘ1 violations
General disrepairⓘ1 violations
Exterior & windowsⓘ1 violations
No specific condition stated9 violations
9 still open. See violation log below.

Top complaint types

5 yrsAll time
General Maintenance Not In List Above7 complaints
Hot Water Lack Of Hot Water4 complaints
Infestation Rodent Insect4 complaints
Doors Windows Broken Defective2 complaints
Fire Hazard2 complaints
Fire Sprinkler System2 complaints
Inadequately Maintained Building Exterior1 complaints
Mold And Mildew1 complaints
Plumbing Broken Leaking1 complaints
Hide violations (154) ↑See complaints (26) →

Violation log

139 DBI violations · Closed

AllOpenClosed
StatusFiledCategoryItemNOV Item Description
not activeSep 1, 2023Heating equipment—No permit to operate the boiler. serial no 12152056, CMC 1022. Monthly monitoring fee applies. Code Sec: SFBC 110A, Table 1A-K
See something wrong? File a complaint with SF 311

Ask how heat and hot water are supplied and who pays for them. If either fails once you live here, put the request to the landlord in writing and keep a copy.

  • California Tenant Guide
  • San Francisco Housing Code §701
  • Tenants here have reported pests.
    Worth checkingⓘ
    Look along baseboards and inside low cabinets for droppings, greasy rub marks or tracks, and check whether the bins outside overflow and whether gaps around exterior doors are sealed.
    details ▸

    California law requires buildings and grounds to be kept clean and sanitary and free from debris, filth, rubbish, garbage, rodents and vermin. San Francisco requires property owners to keep their property free of vermin, and requires an owner or manager to respond to a tenant's bed bug complaint by hiring a licensed pest control operator.

    • California Tenant Guide
    • SF.gov, Keeping your building free of vermin
  • not activeSep 1, 2023Heating equipment—No permit to operate the boiler. serial no 04282125-G2V2, CMC 1022. Monthly monitoring fee applies. Code Sec: SFBC 110A, Table 1A-K
    not activeSep 1, 2023Heating equipment—No permit to operate the boiler. serial no 02152102, CMC 1022. Monthly monitoring fee applies. Code Sec: SFBC 110A, Table 1A-K
    not activeSep 1, 2023Heating equipment—No permit to operate the boiler. serial no 02152105-G2V2, CMC 1022. Monthly monitoring fee applies. Code Sec: SFBC 110A, Table 1A-K
    not activeSep 1, 2023Heating equipment—No permit to operate the boiler. serial no 09042098, CMC 1022. Monthly monitoring fee applies. Code Sec: SFBC 110A, Table 1A-K
    not activeJul 15, 2022Heating equipment—No permit to operate the boiler. serial no 09042098, CMC 1022. Monthly monitoring fee applies. Code Sec: SFBC 110A, Table 1A-K
    not activeJul 15, 2022Heating equipment—No permit to operate the boiler. serial no 02152102, CMC 1022. Monthly monitoring fee applies. Code Sec: SFBC 110A, Table 1A-K
    not activeAug 17, 2021Heating equipment—No permit to operate the boiler. serial no 1810109522937, CMC 1022. Monthly monitoring fee applies. Code Sec: SFBC 110A, Table 1A-K
    not activeAug 17, 2021Heating equipment—No permit to operate the boiler. serial no 0920MOO1237, CMC 1022. Monthly monitoring fee applies. Code Sec: SFBC 110A, Table 1A-K
    not activeAug 17, 2021Heating equipment—No permit to operate the boiler. serial no 0936M001559, CMC 1022. Monthly monitoring fee applies. Code Sec: SFBC 110A, Table 1A-K
    not activeAug 17, 2021Heating equipment—No permit to operate the boiler. serial no 1252E000325, CMC 1022. Monthly monitoring fee applies. Code Sec: SFBC 110A, Table 1A-K
    not activeNov 6, 2019building sectionthis notice includes violations for the areas noted.920 mcallister st. unit a
    not activeNov 6, 2019sanitation sectioneliminate bedbug infestation (1001b, 1306 hc)evidence of bedbug infestation. provide certified pest control to eliminate bed bug infestation. at re-inspection provide sign off by department of public health showing that bed bug protocols have been followed. comply with the bedbug eradication protocol as directed by the environmental health section of the department of public health.
    not activeNov 6, 2019other sectioninspector commentsit is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to secure a different inspection time/date with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b)), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection
    not activeNov 6, 2019building sectiongeneral dilapidation or improper maintenance (1001 (b)(13))at the time of insoection it was noted that the intercom and door system didn't not operate. repair systems back to good working condition.
    not activeJun 3, 2019Heating equipment—No permit to operate the boiler. serial no 1252E000325, CMC 1022
    not activeJun 3, 2019Heating equipment—No permit to operate the boiler. serial no 0920MOO1237, CMC 1022
    not activeJan 2, 2019Heating equipment—No permit to operate the boiler. serial no 0936M001559, CMC 1022
    not activeFeb 6, 2018Heating equipment—No permit to operate the boiler. serial no 0920MOO1237, CMC 1022
    not activeSep 29, 2017Fire safety—A complaint investigation has revealed an unsafe condition in units: 1089C, 1069F, 1069E, 1049F, 1010C, and 1010D. Second means of egress, rear sliding door has been screwed shut. This leads to 2 unit common fire escape, creating an unsafe condition. Code Section: SFBC 102A
    not activeMar 6, 2017Fire safety—A complaint has been filed with this department regarding a potentially hazardous condition at above location in Unit #C. Front bedroom, wall & ceiling finishes have been removed around egress window. Dry rot observed. No building permit. Shielding in place impeding access to egress window. Work started in mid January 2017. Code/Section: SFBC 103A; 102A.3, Table 1A-K; 1029
    not activeOct 19, 2016DBI code violation—1.) A building you owned on September 15, 2013 was noticed as a part of the mandatory Soft Story Retrofit Program. You have failed to submit the Permit Application with plans for Seismic Retrofit work. This building is in violation of the requirements of the San Francisco Building Code regarding earthquake safety. The owner of this building has not complied with the mandatory Soft Story Retrofit Program as required by ( S.F.B.C. 3405B.2 Chapter 34B) 2.) Monthly Monitoring Fee (S.F.B.C. 102A.3 Table 1A-K) 3.) Do not remove the posted "Earthquake Warning" Placard (S.F.B.C. 3405 B.6.1)
    not activeAug 8, 2016Heating equipment—No permit to operate the boiler. serial no 9280827003, CMC 1022
    not activeAug 8, 2016Heating equipment—No permit to operate the boiler. serial no 9280827003, CMC 1022
    not activeAug 8, 2016Heating equipment—No permit to operate the boiler. serial no 0920MOO1237, CMC 1022
    not activeAug 8, 2016Heating equipment—No permit to operate the boiler. serial no 0936M001559, CMC 1022
    not activeAug 8, 2016Heating equipment—No permit to operate the boiler. serial no F07-2853, CMC 1022
    not activeAug 8, 2016Heating equipment—No permit to operate the boiler. serial no F07-2853, CMC 1022
    not activeMar 10, 2016building sectionthis notice includes violations for the areas noted.1039b golden gate avenue.
    not activeMar 10, 2016interior surfaces sectioneliminate mold/mildew on walls (1301,1001b(13),1306 hc)on both bedroom walls and window frames and jambs. address isolated areas in kitchen and living room of units. there is mold visible in all aforementioned areas. wash these surfaces with an appropriate cleaning solution like household bleach diluted in water. if painting is required, paint these surfaces using a mold inhibitor paint additive.
    not activeMar 10, 2016interior surfaces sectioneliminate mold/mildew on walls & ceiling (1301,1001b(13),1306 hc)in bathroom. there is mold visible in all aforementioned areas. wash these surfaces with an appropriate cleaning solution like household bleach diluted in water. if painting is required, paint these surfaces using a mold inhibitor paint additive.
    not activeMar 10, 2016other sectioninspector commentsdue to the violations noted, this property is defined as a nuisance per the san francisco housing code section 1001(d). it is the property owner's responsibility to be present or direct his/her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the reinspection.
    not activeAug 6, 2015building sectionthis notice includes violations for the areas noted.1079 golden gate avenue, unit #b.
    not activeAug 6, 2015interior surfaces sectioneliminate mold/mildew on walls (1301,1001b(13),1306 hc)on bedroom window wall and window door jamb. there is mold visible in all aforementioned areas. wash these surfaces with an appropriate cleaning solution like household bleach diluted in water. if painting is required, paint these surfaces using a mold inhibitor paint additive.
    not activeAug 6, 2015interior surfaces sectiondisturbing lead based paint can be extremely dangerous to dwelling occupants and visitors, particularly to young children, pregnant women, pets, and to people performing work on the premises. for interior or exterior paint removal : always wet the surface, contain and properly dispose of leaded paint. if you are unsure whether the paint is leaded, you should test it prior to performing any work. if the paint is found to contain lead, you should consult with an expert about appropriate procedures. proper containment and 3-day notification is required for exterior jobs of more than 10 sq.ft. (sec.3423, sfbc) informational packets are available at (415) 558-6088. you can contact the san francisco childhood lead poisoning prevention program at: (415) 252-3800 for free advice. if you cause lead dust to be created, you could be liable for any illness caused by the dust. ordinance #446-97.where work is required.
    not activeAug 6, 2015other sectioninspector commentsdue to the violations noted, this property is defined as a nuisance per the san francisco housing code section 1001(d). it is the property owner's responsibility to be present or direct his/her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the reinspection.
    not activeApr 27, 2015Heating equipment—No current permit to operate the boiler. serial no F07-2853, CMC 1022 Monthly violation monitoring fee: $52
    not activeApr 27, 2015Heating equipment—No current permit to operate the boiler. serial no 9280827003, CMC 1022 Monthly violation monitoring fee: $52
    not activeJul 20, 2011Heating equipment—No permit to operate the boiler. CMC 1022, serial no F03-3278
    not activeMar 9, 2009DBI code violation—This Department is requesting access to the basement of the coffee shop to investigate work being performed at PM hours and on weekends (CPC/SFPC Sec. 103)
    not activeAug 25, 2008building sectionthis notice includes violations for the areas noted.1039 golden gate av., unit f.
    not activeAug 25, 2008building sectiongeneral dilapidation or improper maintenance 1001.(b)(13) hcbedroom 1 (master): repair or replace damaged window sill.
    not activeAug 25, 2008interior surfaces sectioneliminate mold/mildew on walls (1301,1001b(13),1306 hc)eliminate mold from window frames and caulking seal clean mold/mildew with a commercial mildewcide or a solution of 1 1/2 cups bleach to 1 gallon of water. note: bleach is hazardous, wear gloves and eye protection and have good air circulation. add mildewcide additive to paint applied in affected areas.
    not activeAug 25, 2008interior surfaces sectionremove or cover damaged paint in an approved manner to prevent a lead hazard. see attached lead hazard warning. (1301 hc)at all work areas.
    not activeAug 25, 2008interior surfaces sectionpaint walls (1001b,1301 hc)at all work areas.
    not activeAug 25, 2008interior surfaces sectiondisturbing lead based paint can be extremely dangerous to dwelling occupants and visitors, particularly to young children, pregnant women, pets, and to people performing work on the premises. for interior or exterior paint removal : always wet the surface, contain and properly dispose of leaded paint. if you are unsure whether the paint is leaded, you should test it prior to performing any work. if the paint is found to contain lead, you should consult with an expert about appropriate procedures. proper containment and 3-day notification is required for exterior jobs of more than 10 sq.ft. (sec.3604, sfbc) informational packets are available at (415) 558-6088. you can contact the san francisco childhood lead poisoning prevention program at: (415) 554-8930 for free advice. if you cause lead dust to be created, you could be liable for any illness caused by the dust. ordinance #446-97.do all work in a lead safe manner.
    not activeAug 25, 2008other sectioninspector commentsit is the property owner's responsibility to be present or direct his/ her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/ or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/ her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954. san francisco housing code section 303.(b), if any dwelling, apartment units or guest rooms are to be accessed during the reinspection.
    not activeAug 21, 2008building sectionthis notice includes violations for the areas noted.1039 golden gate av. unit d.
    not activeAug 21, 2008building sectiongeneral dilapidation or improper maintenance 1001.(b)(13) hcbedroom 1, 2 and living room: repair or replace damaged window sills.
    not activeAug 21, 2008interior surfaces sectioneliminate mold/mildew on walls (1301,1001b(13),1306 hc)eliminate mold from window frames and caulking seal clean mold/mildew with a commercial mildewcide or a solution of 1 1/2 cups bleach to 1 gallon of water. note: bleach is hazardous, wear gloves and eye protection and have good air circulation. add mildewcide additive to paint applied in affected areas.
    not activeSep 1, 2023
    Heating equipment
    No permit to operate the boiler. serial no 12152056, CMC 1022. Monthly monitoring fee applies. Code Sec: SFBC 110A, Table 1A-K
    not activeSep 1, 2023
    Heating equipment
    No permit to operate the boiler. serial no 04282125-G2V2, CMC 1022. Monthly monitoring fee applies. Code Sec: SFBC 110A, Table 1A-K
    not activeSep 1, 2023
    Heating equipment
    No permit to operate the boiler. serial no 02152102, CMC 1022. Monthly monitoring fee applies. Code Sec: SFBC 110A, Table 1A-K
    not activeSep 1, 2023
    Heating equipment
    No permit to operate the boiler. serial no 02152105-G2V2, CMC 1022. Monthly monitoring fee applies. Code Sec: SFBC 110A, Table 1A-K
    not activeSep 1, 2023
    Heating equipment
    No permit to operate the boiler. serial no 09042098, CMC 1022. Monthly monitoring fee applies. Code Sec: SFBC 110A, Table 1A-K
    not activeJul 15, 2022
    Heating equipment
    No permit to operate the boiler. serial no 09042098, CMC 1022. Monthly monitoring fee applies. Code Sec: SFBC 110A, Table 1A-K
    not activeJul 15, 2022
    Heating equipment
    No permit to operate the boiler. serial no 02152102, CMC 1022. Monthly monitoring fee applies. Code Sec: SFBC 110A, Table 1A-K
    not activeAug 17, 2021
    Heating equipment
    No permit to operate the boiler. serial no 1810109522937, CMC 1022. Monthly monitoring fee applies. Code Sec: SFBC 110A, Table 1A-K
    not activeAug 17, 2021
    Heating equipment
    No permit to operate the boiler. serial no 0920MOO1237, CMC 1022. Monthly monitoring fee applies. Code Sec: SFBC 110A, Table 1A-K
    not activeAug 17, 2021
    Heating equipment
    No permit to operate the boiler. serial no 0936M001559, CMC 1022. Monthly monitoring fee applies. Code Sec: SFBC 110A, Table 1A-K
    not activeAug 17, 2021
    Heating equipment
    No permit to operate the boiler. serial no 1252E000325, CMC 1022. Monthly monitoring fee applies. Code Sec: SFBC 110A, Table 1A-K
    not activeNov 6, 2019
    building section · this notice includes violations for the areas noted.
    920 mcallister st. unit a
    not activeNov 6, 2019
    sanitation section · eliminate bedbug infestation (1001b, 1306 hc)
    evidence of bedbug infestation. provide certified pest control to eliminate bed bug infestation. at re-inspection provide sign off by department of public health showing that bed bug protocols have been followed. comply with the bedbug eradication protocol as directed by the environmental health section of the department of public health.
    not activeNov 6, 2019
    other section · inspector comments
    it is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to secure a different inspection time/date with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b)), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection
    not activeNov 6, 2019
    building section · general dilapidation or improper maintenance (1001 (b)(13))
    at the time of insoection it was noted that the intercom and door system didn't not operate. repair systems back to good working condition.
    not activeJun 3, 2019
    Heating equipment
    No permit to operate the boiler. serial no 1252E000325, CMC 1022
    not activeJun 3, 2019
    Heating equipment
    No permit to operate the boiler. serial no 0920MOO1237, CMC 1022
    not activeJan 2, 2019
    Heating equipment
    No permit to operate the boiler. serial no 0936M001559, CMC 1022
    not activeFeb 6, 2018
    Heating equipment
    No permit to operate the boiler. serial no 0920MOO1237, CMC 1022
    not activeSep 29, 2017
    Fire safety
    A complaint investigation has revealed an unsafe condition in units: 1089C, 1069F, 1069E, 1049F, 1010C, and 1010D. Second means of egress, rear sliding door has been screwed shut. This leads to 2 unit common fire escape, creating an unsafe condition. Code Section: SFBC 102A
    not activeMar 6, 2017
    Fire safety
    A complaint has been filed with this department regarding a potentially hazardous condition at above location in Unit #C. Front bedroom, wall & ceiling finishes have been removed around egress window. Dry rot observed. No building permit. Shielding in place impeding access to egress window. Work started in mid January 2017. Code/Section: SFBC 103A; 102A.3, Table 1A-K; 1029
    not activeOct 19, 2016
    DBI code violation
    1.) A building you owned on September 15, 2013 was noticed as a part of the mandatory Soft Story Retrofit Program. You have failed to submit the Permit Application with plans for Seismic Retrofit work. This building is in violation of the requirements of the San Francisco Building Code regarding earthquake safety. The owner of this building has not complied with the mandatory Soft Story Retrofit Program as required by ( S.F.B.C. 3405B.2 Chapter 34B) 2.) Monthly Monitoring Fee (S.F.B.C. 102A.3 Table 1A-K) 3.) Do not remove the posted "Earthquake Warning" Placard (S.F.B.C. 3405 B.6.1)
    not activeAug 8, 2016
    Heating equipment
    No permit to operate the boiler. serial no 9280827003, CMC 1022
    not activeAug 8, 2016
    Heating equipment
    No permit to operate the boiler. serial no 9280827003, CMC 1022
    not activeAug 8, 2016
    Heating equipment
    No permit to operate the boiler. serial no 0920MOO1237, CMC 1022
    not activeAug 8, 2016
    Heating equipment
    No permit to operate the boiler. serial no 0936M001559, CMC 1022
    not activeAug 8, 2016
    Heating equipment
    No permit to operate the boiler. serial no F07-2853, CMC 1022
    not activeAug 8, 2016
    Heating equipment
    No permit to operate the boiler. serial no F07-2853, CMC 1022
    not activeMar 10, 2016
    building section · this notice includes violations for the areas noted.
    1039b golden gate avenue.
    not activeMar 10, 2016
    interior surfaces section · eliminate mold/mildew on walls (1301,1001b(13),1306 hc)
    on both bedroom walls and window frames and jambs. address isolated areas in kitchen and living room of units. there is mold visible in all aforementioned areas. wash these surfaces with an appropriate cleaning solution like household bleach diluted in water. if painting is required, paint these surfaces using a mold inhibitor paint additive.
    not activeMar 10, 2016
    interior surfaces section · eliminate mold/mildew on walls & ceiling (1301,1001b(13),1306 hc)
    in bathroom. there is mold visible in all aforementioned areas. wash these surfaces with an appropriate cleaning solution like household bleach diluted in water. if painting is required, paint these surfaces using a mold inhibitor paint additive.
    not activeMar 10, 2016
    other section · inspector comments
    due to the violations noted, this property is defined as a nuisance per the san francisco housing code section 1001(d). it is the property owner's responsibility to be present or direct his/her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the reinspection.
    not activeAug 6, 2015
    building section · this notice includes violations for the areas noted.
    1079 golden gate avenue, unit #b.
    not activeAug 6, 2015
    interior surfaces section · eliminate mold/mildew on walls (1301,1001b(13),1306 hc)
    on bedroom window wall and window door jamb. there is mold visible in all aforementioned areas. wash these surfaces with an appropriate cleaning solution like household bleach diluted in water. if painting is required, paint these surfaces using a mold inhibitor paint additive.
    not activeAug 6, 2015
    interior surfaces section · disturbing lead based paint can be extremely dangerous to dwelling occupants and visitors, particularly to young children, pregnant women, pets, and to people performing work on the premises. for interior or exterior paint removal : always wet the surface, contain and properly dispose of leaded paint. if you are unsure whether the paint is leaded, you should test it prior to performing any work. if the paint is found to contain lead, you should consult with an expert about appropriate procedures. proper containment and 3-day notification is required for exterior jobs of more than 10 sq.ft. (sec.3423, sfbc) informational packets are available at (415) 558-6088. you can contact the san francisco childhood lead poisoning prevention program at: (415) 252-3800 for free advice. if you cause lead dust to be created, you could be liable for any illness caused by the dust. ordinance #446-97.
    where work is required.
    not activeAug 6, 2015
    other section · inspector comments
    due to the violations noted, this property is defined as a nuisance per the san francisco housing code section 1001(d). it is the property owner's responsibility to be present or direct his/her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the reinspection.
    not activeApr 27, 2015
    Heating equipment
    No current permit to operate the boiler. serial no F07-2853, CMC 1022 Monthly violation monitoring fee: $52
    not activeApr 27, 2015
    Heating equipment
    No current permit to operate the boiler. serial no 9280827003, CMC 1022 Monthly violation monitoring fee: $52
    not activeJul 20, 2011
    Heating equipment
    No permit to operate the boiler. CMC 1022, serial no F03-3278
    not activeMar 9, 2009
    DBI code violation
    This Department is requesting access to the basement of the coffee shop to investigate work being performed at PM hours and on weekends (CPC/SFPC Sec. 103)
    not activeAug 25, 2008
    building section · this notice includes violations for the areas noted.
    1039 golden gate av., unit f.
    not activeAug 25, 2008
    building section · general dilapidation or improper maintenance 1001.(b)(13) hc
    bedroom 1 (master): repair or replace damaged window sill.
    not activeAug 25, 2008
    interior surfaces section · eliminate mold/mildew on walls (1301,1001b(13),1306 hc)
    eliminate mold from window frames and caulking seal clean mold/mildew with a commercial mildewcide or a solution of 1 1/2 cups bleach to 1 gallon of water. note: bleach is hazardous, wear gloves and eye protection and have good air circulation. add mildewcide additive to paint applied in affected areas.
    not activeAug 25, 2008
    interior surfaces section · remove or cover damaged paint in an approved manner to prevent a lead hazard. see attached lead hazard warning. (1301 hc)
    at all work areas.
    not activeAug 25, 2008
    interior surfaces section · paint walls (1001b,1301 hc)
    at all work areas.
    not activeAug 25, 2008
    interior surfaces section · disturbing lead based paint can be extremely dangerous to dwelling occupants and visitors, particularly to young children, pregnant women, pets, and to people performing work on the premises. for interior or exterior paint removal : always wet the surface, contain and properly dispose of leaded paint. if you are unsure whether the paint is leaded, you should test it prior to performing any work. if the paint is found to contain lead, you should consult with an expert about appropriate procedures. proper containment and 3-day notification is required for exterior jobs of more than 10 sq.ft. (sec.3604, sfbc) informational packets are available at (415) 558-6088. you can contact the san francisco childhood lead poisoning prevention program at: (415) 554-8930 for free advice. if you cause lead dust to be created, you could be liable for any illness caused by the dust. ordinance #446-97.
    do all work in a lead safe manner.
    not activeAug 25, 2008
    other section · inspector comments
    it is the property owner's responsibility to be present or direct his/ her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/ or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/ her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954. san francisco housing code section 303.(b), if any dwelling, apartment units or guest rooms are to be accessed during the reinspection.
    not activeAug 21, 2008
    building section · this notice includes violations for the areas noted.
    1039 golden gate av. unit d.
    not activeAug 21, 2008
    building section · general dilapidation or improper maintenance 1001.(b)(13) hc
    bedroom 1, 2 and living room: repair or replace damaged window sills.
    not activeAug 21, 2008
    interior surfaces section · eliminate mold/mildew on walls (1301,1001b(13),1306 hc)
    eliminate mold from window frames and caulking seal clean mold/mildew with a commercial mildewcide or a solution of 1 1/2 cups bleach to 1 gallon of water. note: bleach is hazardous, wear gloves and eye protection and have good air circulation. add mildewcide additive to paint applied in affected areas.