not activeDec 8, 2025
building section · this notice includes violations for the areas noted.
this notice includes violations of the san francisco housing code. unless noted otherwise, all violations were observed on the date of inspection at 2055 sacramento street, san francisco, ca.
not activeDec 8, 2025
building section · post certification of current alarm system maintenance by qualified contractor 908, 909, 911 sfhc
the alarm system at the front hallway by the manager's office is in distress. investigate and find the issue causing distress. repair the fire alarm systems. all testing and maintenance shall be conducted according to the manufacturer's recommendations.
not activeDec 8, 2025
building section · provide a building caretaker 1311 sfhc
there is no indication of the building caretaker at the front entry. a janitor, housekeeper or other responsible person shall reside upon the premises and shall have charge of this apartment house, if the owner does not reside upon the premises. in either case a notice of this agent and his unit shall be posted in a conspicuous place at the front entry. provide the onsite building manager's contact information at the front entry in the electronic entry system or on a permanent sign with lettering in contrasting color to the background so that they are easily visible to emergency service workers. all numbers shall be made of substantial and permanent materials and installed in a permanent manner.
not activeDec 8, 2025
other section · inspector comments
important note: due to the nature of this violation, this property has been defined as a nuisance per section 1001-d of the san francisco housing code. it is the property owner¿s responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection.
OpenDec 8, 2025
other section · inspector comments
important note: due to the nature of this violation, this property has been defined as a nuisance per section 1001-d of the san francisco housing code. it is the property owner¿s responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection.
OpenDec 8, 2025
building section · this notice includes violations for the areas noted.
this notice includes violations of the san francisco housing code. unless noted otherwise, all violations were observed on the date of inspection at 2055 sacramento street, unit 607, san francisco, ca.
OpenDec 8, 2025
building section · repair window glazing seals and weatherproofing 1001h, j, & 708 sfhc
the unit windows leak when it rains., on the south and the north side. repair or replace the windows to provide a weather tight condition.
OpenDec 8, 2025
building section · repair the spalling concrete 1001 b13, c4 sfhc
the sills and walls below the leaking windows are spalling. the concrete has deteriorated. remove damaged or contaminated materials and replace with new. prep, prime and paint to complete the repair.
OpenDec 8, 2025
building section · replace the water damaged shelf 1001b13, d sfhc
there is a high pressure laminate shelf in the child's room in this unit. the shelf is water damaged and the particle board substructure is deteriorating and the laminate is delaminating. replace the shelf.
OpenDec 8, 2025
building section · repair the weather proofing of the window 1001 b13, d, h sfhc
there is evidence of water damage at the top of the window in the child's room. repair the window to create a water proof condition.
OpenDec 8, 2025
building section · repair the entry door 1001b13, 706 sfhc
the entry door to the unit has swollen. the leading edge of the door drags on the jamb. repair the entry door. upon completion the door and jamb shall be tight fitting, in good condition, self-closing and self-latching.
OpenDec 8, 2025
building section · repair the bedroom door 1001b13 sfhc
the door to the master bedroom has a stop that was installed out of plumb. the correction provided (a screw at the bottom of the stop) is a substandard repair. remove and re-install the stop to match the leading edge of the door. prep, prime and paint the jamb to complete the repair.
OpenDec 8, 2025
building section · repair or replace the dead bolt 1001b13, 706 sfhc
the dead bolt in the front entry door to the unit has a malfunctioning cylinder. repair or replace the dead bolt.
OpenDec 8, 2025
building section · encapsulate or remove the popcorn ceiling 1001k, d, 1301 sfhc
the shelf life for the acoustic spray (popcorn ceiling) has long past. given the date of construction of this building, the product likely contains asbestos. in addition, the product is friable. remove (not recommended) or encapsulate the popcorn ceiling. encapsulate the popcorn ceiling using specialized encapsulant paint, or by applying a high-quality acrylic latex paint, which seals the surface, binds fibers, and prevents dust. safety note: your building was built before 1978; the ceiling may contain asbestos, making encapsulation a safer alternative to removal. preparation: before painting, it is highly recommended to use a primer, such as an oil-based primer like kilz, to harden the texture. best paint type: use interior flat or matte acrylic latex paint. flat finishes hide imperfections better than glossy ones. specialized products: products like hy-tech encapsulguard are designed to adhere directly to older surfaces, including those that may contain asbestos or lead. application methods: sprayer: a paint sprayer is generally preferred to avoid removing or damaging the delicate texture. roller: use a thick nap roller (3/4" to 1-1/4" knap) and apply gentle pressure to prevent the texture from breaking off. removing popcorn ceilings involves spraying the texture with water to soften it, then scraping it off with a putty knife, making it messy. removal shall require an asbestos remediation company. if this method is chosen, provide invoicing
not activeJan 15, 2025
building section · this notice includes violations for the areas noted.
this notice includes violations of the san francisco housing code. unless noted otherwise, all violations were observed on the date of inspection at 2055 sacramento street, unit 602, san francisco, ca.
not activeJan 15, 2025
building section · eliminate mold/mildew in shower surround 1001b11, d, 1002d, 1301, 1306 sfhc, 1210.2.4 sfbc
the waterproof joint between the tub and the tiled wall surface above is contaminated with mold trapped behind it. remove the contaminated material and replace it to provide a water proof joint between the tub and the tile wall surface area.
not activeJan 15, 2025
building section · repair or replace the wasteoverflow valve 1001 f sfhc
there are 2 exploratory holes cut in the north and south sides of the bath tub in the adjacent rooms' closets. the north side reveals a large rusted area in the northeast corner of the bathtub. the south side reveals a leak when the supply line to the shower is turned on. it appears to trickle down the waste overflow and drip off at the drain to the concrete deck below. find and fix the source of the leak.
not activeJan 15, 2025
building section · replace the carpet 1001b13, d, 1306 sfhc
due to the leak from the bathtub, the carpet in the closet to the north has outlasted its serviceable life time. the weave is matted and worn. shampooing and stretching will not provide additional wear. the carpet tack strips are rotted from water damage. replace the flooring in the closet.
not activeJan 15, 2025
other section · inspector comments
important note: due to the nature of this violation, this property has been defined as a nuisance per section 1001-d of the san francisco housing code. it is the property owner¿s responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection
not activeDec 17, 2024
building section · this notice includes violations for the areas noted.
2055 sacramento street, unit 1007, san francisco, ca.
not activeDec 17, 2024
building section · provide engineering services 1001c4, d sfhc
the concrete walls around the windows of unit 1007 show signs of spalling and fatigue. the interior elevations of these same walls have water damage. there have been dozens of complaints of the same nature going back to 2014 for water intrusion and mold. secure the services of a civil/structural engineer to provide structural analysis and repair of these walls in this and any other similar areas. a performance based corrective report shall be included in the building permit application package for the repair of these walls.
not activeDec 17, 2024
building section · provide building permits 106a.1 sfbc, 301 sfhc
you are required to obtain a building permit to correct this violation. when applying for a building permit, reference the complaint number from this notice of violation. attach 2 copies of the engineering report along with 2 sets of architectural drawings (if applicable) for the reconstruction of this area. the building inspector must perform periodic and final inspections and sign the job card before the housing division can abate this violation. present the signed job card indicating that work is complete to the housing inspector on the date of re-inspection.
not activeDec 17, 2024
building section · repair the concrete walls 1001c4, d sfhc
repair the concrete walls as described by the engineering report.
not activeDec 17, 2024
building section · provide weather protection 703, 1001d, h3 sfhc
once the concrete repairs have been completed, weather proofing is necessary. repair the walls, prep, seal, prime and paint the surfaces of the outside face of the building as necessary. *** sidewalk permits are necessary for scaffold used at the front facade.
not activeDec 17, 2024
building section · repair weather proofing of windows 1001d, h, 703 sfhc
in unit 1007, the windows weep holes cannot keep up with the rain water drainage as intended. there is a large crack in the sill that overflows with water in the rain and empties onto the floor. repair or replace the windows to provide proper drainage. repair the crack at the sill in an approved manner.
not activeDec 17, 2024
other section · inspector comments
important note: due to the nature of this violation, this property has been defined as a nuisance per section 1001-d of the san francisco housing code. it is the property owner¿s responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection.
not activeMar 5, 2024
building section · this notice includes violations for the areas noted.
this notice includes violations of the san francisco housing code. unless noted otherwise, all violations were observed on the date of inspection at 2055 sacramento street, unit 809, san francisco, ca.
not activeMar 5, 2024
building section · locate source of water intrusion and repair 703, 1001f sfhc
water is entering the back wall of the walk-in closet. the closet has new carpet that is wet at the base of the back wall. the tenants state this is due to a failed repair. provide a mechanical system to dry the carpets and floor diaphragm. find and fix the source of the leak.
not activeMar 5, 2024
other section · inspector comments
important note: due to the nature of this violation, this property has been defined as a nuisance per section 1001-d of the san francisco housing code. it is the property owner¿s responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection.
not activeSep 26, 2022
building section · this notice includes violations for the areas noted.
this notice includes violations of the san francisco housing code. unless noted otherwise, all violations were observed on the date of inspection at 2055 sacramento street, unit 1006.
not activeSep 26, 2022
building section · provide engineering services 1001c4, d sfhc
the concrete walls around the windows of unit 1006 show signs of spalling and fatigue. the interior elevations of these same walls have water damage. there have been dozens of complaints of the same nature going back to 2014 for water intrusion and mold. secure the services of a civil/structural engineer to provide structural analysis and repair of these walls in this and any other similar areas. a performance based corrective report shall be included in the building permit application package for the repair of these walls.
not activeSep 26, 2022
building section · provide building permits 106a.1 sfbc, 301 sfhc
you are required to obtain a building permit to correct this violation. when applying for a building permit, reference the complaint number from this notice of violation. attach 2 copies of the engineering report along with 2 sets of architectural drawings (if applicable) for the reconstruction of this area. the building inspector must perform periodic and final inspections and sign the job card before the housing division can abate this violation. present the signed job card indicating that work is complete to the housing inspector on the date of re-inspection.
not activeSep 26, 2022
building section · repair the concrete walls 1001c4, d sfhc
repair the concrete walls as described by the engineering report.
not activeSep 26, 2022
building section · provide weather protection 703, 1001d, h3 sfhc
once the concrete repairs have been completed, weather proofing is necessary. repair the walls, prep, seal, prime and paint the surfaces of the outside face of the building as necessary. *** sidewalk permits are necessary for scaffold used at the front facade.
not activeSep 26, 2022
building section · repair weather proofing of windows 1001d, h, 703 sfhc
in unit 1006, the windows weep holes cannot keep up with the rain water drainage as intended. there is a large crack in the sill that overflows with water in the rain and empties onto the floor. repair or replace the windows to provide proper drainage. repair the crack at the sill in an approved manner.
not activeSep 26, 2022
other section · inspector comments
important note: due to the nature of this violation, this property has been defined as a nuisance per section 1001-d of the san francisco housing code. it is the property owner¿s responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection.
not activeMar 7, 2019
building section · this notice includes violations for the areas noted.
2055 sacramento street #803
not activeMar 7, 2019
interior surfaces section · repair damaged ceilings and repaint(1001b,h,o hc)
repair damaged ceiling and repaint above the window in the bedroom at the entrance door side. note: some materials may contain asbestos. follow procedures set forth by the department of public health when there is a possibility that asbestos may be present.
not activeMar 7, 2019
other section · inspector comments
due to the violations noted, this constitutes a nuisance per the san francisco housing code section 1001(d) it is the property owner's responsibility to be present or direct his/her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the reinspection.
not activeJan 11, 2017
building section · this notice includes violations for the areas noted.
2055 sacramento street unit #1008
not activeJan 11, 2017
interior surfaces section · locate source of leakage at window area and repair (703, 1001f hc)
locate source of leakage at both window areas and repair.
not activeJan 11, 2017
interior surfaces section · repair damaged walls (1001b,h,o hc)
after leakage is repaired, repair and paint damaged wall areas where leakage has occured(at edges below window). -reattach loose baseboards.
not activeJan 11, 2017
interior surfaces section · paint walls and window ledges (1001b,1301 hc)
paint walls and window ledges at both windows, below windows and baseboards where paint is chipping and/or peeling.
not activeJan 11, 2017
interior surfaces section · disturbing lead based paint can be extremely dangerous to dwelling occupants and visitors, particularly to young children, pregnant women, pets, and to people performing work on the premises. for interior or exterior paint removal : always wet the surface, contain and properly dispose of leaded paint. if you are unsure whether the paint is leaded, you should test it prior to performing any work. if the paint is found to contain lead, you should consult with an expert about appropriate procedures. proper containment and 3-day notification is required for exterior jobs of more than 10 sq.ft. (sec.3423, sfbc) informational packets are available at (415) 558-6088. you can contact the san francisco childhood lead poisoning prevention program at: (415) 252-3800 for free advice. if you cause lead dust to be created, you could be liable for any illness caused by the dust. ordinance #446-97.
lead warning.
not activeJan 11, 2017
interior surfaces section · eliminate mold/mildew on walls (1301,1001b(13),1306 hc)
eliminate mold/mildew on the window frame bases, window ledges,walls below window and where carpet has become wet from leakage.
not activeJan 11, 2017
sanitation section · clean or sanitize (1306 hc)
thoroughly clean and dry carpet area that has become wet from leakage.
not activeJan 11, 2017
other section · inspector comments
due to the violations noted, this constitutes a nuisance per the san francisco housing code section 1001(d) it is the property owner's responsibility to be present or direct his/her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the reinspection.
not activeJun 30, 2015
building section · this notice includes violations for the areas noted.
2055 sacramento street unit #904
not activeJun 30, 2015
interior surfaces section · repair weather stripping. (1001 hc)
repair/replace deteriorated weather stripping at the entrance door.
not activeJun 30, 2015
interior surfaces section · repair damaged walls (1001b,h,o hc)
repair damaged wall in the bedroom at the base behind the door. also secure base board.