276 GOLDEN GATE AVE

Tenderloin · San Francisco, CA · Parcel 0345008 · Last violation Mar 18, 2022 · Last complaint Oct 24, 2026

NeighborhoodTenderloin
Above-average violations for the neighborhood
More violations than 68% of buildings and more complaints than 90% of buildings in Tenderloin. Size-normalized against residential buildings in the neighborhood.
ViolationsComplaints
Activity TrendsLast 5 years
A steady level of activity over time
Last 2 yrs: 0 violations · 11 complaints
'22'26ViolationsComplaints
Severityⓘopen violations
1 open fire-safety violation
Active Notices of Violation issued by the Department of Building Inspection.
Severe1
Serious3
Minor1

What to watch forⓘ

  1. Tenants here have reported no heat or no hot water.
    details ▸

    California law requires heating facilities in good working order, and plumbing facilities in good working order including hot and cold running water. A rental unit that substantially lacks either may be legally uninhabitable, which is the standard the implied warranty of habitability sets for every residential tenancy in the state.

    Ask how heat and hot water are supplied and who pays for them. If either fails once you live here, put the request to the landlord in writing and keep a copy.

    • California Tenant Guide
    • San Francisco Housing Code §701
  2. Fire safety problems have been reported here.
    Worth checkingⓘ
    Walk the exit route from the unit to the street and check the stairs and hallways are clear of stored items, and that fire doors close properly.
    details ▸

    California law requires safe fire or emergency exits leading to a street or hallway, and requires stairs, hallways and exits to be kept litter free. Storage areas, garages and basements must be kept free of combustible materials. San Francisco's Housing Code separately treats inadequate exits and inadequate fire protection equipment as conditions that make a building substandard, which is the finding behind a notice of violation.

311 Housing Complaints
Total complaints since 2011
14
<1 per year avg.↑ Rising — no prior history
Complaint severity
Last 5 years
11
Severeⓘ3
Seriousⓘ6
Minorⓘ2
Dept. of Building Inspection Violations
Total violations since 1999
100
4 per year avg.— Not enough history to determine trend
Open violations
5
Severeⓘ1
Seriousⓘ3
Minorⓘ1

Top violation categories

5 yrsAll time
Exterior & windowsⓘ18 violations
Fire safetyⓘ15 violations
Walls, ceilings & cabinetsⓘ14 violations
Plumbingⓘ9 violations
Smoke detectorsⓘ5 violations
Ventilation & lightⓘ4 violations
Floors & stairsⓘ3 violations
Permits & unpermitted workⓘ2 violations
Gas shutoff & metersⓘ2 violations
Electricalⓘ2 violations
Cleanliness & refuseⓘ2 violations
Locks & securityⓘ1 violations
Peeling paintⓘ1 violations
Heat / hot waterⓘ1 violations
No specific condition stated21 violations
2 still open. See violation log below.

Top complaint types

5 yrsAll time
Hide violations (100) ↑See complaints (14) →

Violation log

95 DBI violations · Closed

AllOpenClosed
StatusFiledCategoryItemNOV Item Description
not activeMar 9, 2022building sectionthis notice includes violations for the areas noted.284 golden gate st. apt#18
See something wrong? File a complaint with SF 311
  • California Tenant Guide
  • San Francisco Housing Code §1001(m), (n)
  • Smoke detector problems have been reported here.
    Worth checkingⓘ
    Look for a smoke detector in each bedroom and in the common stairwell, and for a carbon monoxide detector if the unit has a gas stove, a gas heater or an attached garage.
    details ▸

    California law requires working smoke detectors in all bedrooms and other designated areas of a rental unit, and apartment complexes must also have them in common stairwells. Any unit with appliances that burn fossil fuels such as natural gas, propane or fuel oil, or with an attached garage, must also have working carbon monoxide detectors.

    • California Tenant Guide
  • Infestation Rodent Insect5 complaints
    Electrical Hazardous Condition2 complaints
    Electrical Non Hazard2 complaints
    Mold And Mildew1 complaints
    Clutter Hoarder Unit Interior Storage1 complaints
    Second Hand Smoke1 complaints
    Heat Lack Of Heat1 complaints
    Hot Water Lack Of Hot Water1 complaints
    not activeMar 9, 2022other sectionprovide heat to each occupied habitable sro room for 13 hrs between 5:00 a.m. and 11:00 a.m. and between 3:00 p.m. and 10:00 p.m. capable to maintaining a min. room temp. of 68 degrees f. (20 degrees c.). (701c hc)no heat source was found in unit during inspection. provide heat per the housing code minimium requirements.
    not activeMar 9, 2022other sectioninspector commentsnuisance (401(2) (1001(d) hc) it is the property owner's responsibility to be present or direct his/her representative to attend the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection time/date with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b)), if any dwellings, apartment units or guest rooms are to be accessed during the reinspection.
    not activeSep 12, 2014building sectionthis notice includes violations for the areas noted.this notice includes violations of the san francisco housing code. unless noted otherwise, all violations were observed on the date of inspection at 284 golden gate avenue.
    not activeSep 12, 2014building sectionrepair or replace the brick chimney and flue lining 1001g sfhcthe chimney behind the roof access penthouse has been compromised. there are partial courses of brick and sections of clay flue liner missing. repair or replace this chimney to support the mechanical systems below in an approved manner.
    not activeSep 12, 2014building sectionbuilding permit required (301 hc)you are required to obtain a building permit to correct this violation. when applying for a building permit, reference the complaint number from this notice of violation. the building inspector must perform periodic and final inspections and sign the job card before the housing division can abate this violation.
    not activeSep 12, 2014building sectionprovide weather proofing at roof (1001(h),703 hc)the roof access penthouse roofing material is re-directing water into the flue of the brick chimney. once the conditions of the chimney have been resolved a weather proof roofing condition shall be offered to correct this problem.
    not activeSep 12, 2014plumbing and electrical sectionmake necessary repairs to shower 1001f sfhcthe third floor shower has a crack through the fiberglass material causing a leak situation. repair, restore or replace the shower stall to provide a water tight finish with a sanitary, smooth, cleanable surface finish.
    not activeSep 12, 2014fire sectionremove egress obstruction 801, 1001(l) sfhcremove the television and trash cans from the third floor landing. the trash cans should be in an approved indoor trash area or open to blue sky.
    not activeSep 12, 2014plumbing and electrical sectionprovide a cover plate 1001e sfhcin unit 22 there is an open junction box for a light switch near the sink basin. provide an approved cover plate.
    not activeSep 12, 2014plumbing and electrical sectionrepair sink (1001f hc)in unit 24 there is an active leak at the sink faucet and in the p trap. find the source of each leak and repair as necessary.
    not activeSep 12, 2014plumbing and electrical sectionreplace broken glass window panes 1001h, 708 sfhcin unit 24, replace the broken glass panel in the window.
    not activeSep 12, 2014plumbing and electrical sectionrepair window sash frame 1001h, 708 sfhcin unit 24, repair the window sash frame. insure that the sash and frame provide smooth and easy operation and a weather tight condition with a working latch. window is to remain at any desired open position with the balance of a counter weight.
    not activeSep 12, 2014plumbing and electrical sectionreplace window sash cords 1001h, 708 sfhcreplace the missing/broken sash cords in unit 24.
    not activeSep 12, 2014plumbing and electrical sectionreplace the missing tile 1001b, d, j sfhcin the third floor toilet room there is a missing ceramic tile creating an insanitary condition that cannot be cleaned properly. replace the missing tile and finish as necessary.
    not activeSep 12, 2014plumbing and electrical sectionreplace window sash cords 1001h, 708 sfhcin the third floor toilet and tub room, replace the missing sash cords and counter balances. insure that the sash and frame provide smooth and easy operation and a weather tight condition with a working latch. window is to remain at any desired open position with the balance of a counter weight.
    not activeSep 12, 2014plumbing and electrical sectionrepair damaged walls 1001 b, d, h, 1301 sfhcin unit 25 under the window, the wall shall be properly plastered as necessary to close all gaps, cracks and holes. after repairing, these walls are to be primed and painted to a durable and cleanable surface.
    not activeSep 12, 2014plumbing and electrical sectionrepair damaged walls 1001 b, d, h, 1301 sfhcin unit 27 behind the door, the wall shall be properly plastered as necessary to close all gaps, cracks and holes. after repairing, these walls are to be primed and painted to a durable and cleanable surface.
    not activeSep 12, 2014sanitation sectionrepair damaged ceilings 1001 b ,d, h, 1301 sfhcin unit 27, the ceiling shall be properly plastered as necessary to close all gaps, cracks and holes. after repairing, these areas are to be primed and painted to a durable and cleanable surface.
    not activeSep 12, 2014sanitation sectionrepair the leaking faucet 1001f sfhcin unit 27 the hot water faucet has a steady stream with the faucet handle turned all the way off. repair or replace the faucet as necessary.
    not activeSep 12, 2014sanitation sectionrepair the leaking faucet 1001f sfhcin unit 17 the hot water supply line has a leak. repair or replace this supply line as necessary to fix the leak.
    not activeSep 12, 2014sanitation sectionprovide adequate lighting 504g sfhcin the south end of the hallway of the third floor near the fire escape, there is a missing light bulb. replace the light bulb to provide adequate lighting to this area.
    not activeSep 12, 2014sanitation sectionprovide adequate lighting 504g sfhcprovide a fixture at the landing between the second and third floor to provide adequate lighting to this area.
    not activeSep 12, 2014sanitation sectionremove the unsecured carpet 1001b, d, j sfhcthe loose area rugs at the top of the stairs create a trip hazard. remove the area rugs and provide a secured, durable and cleanable floor surface.
    not activeSep 12, 2014sanitation sectionrepair damaged ceilings 1001 b ,d, h, 1301 sfhcin unit 26, the ceiling shall be properly plastered as necessary to close all gaps, cracks and holes. after repairing, these areas are to be primed and painted to a durable and cleanable surface.
    not activeSep 12, 2014sanitation sectionrepair damaged walls 1001 b ,d, h, 1301 sfhcin unit 26, the walls around the p trap shall be properly plastered as necessary to close all gaps, cracks and holes. after repairing, this area is to be primed and painted to a durable and cleanable surface.
    not activeSep 12, 2014sanitation sectionreplace the broken weather stripping 1001d sfhcat the front door to guest room 26, replace the broken weather stripping.
    not activeSep 12, 2014sanitation sectionremove the egress obstruction 801, 1001l sfhcremove the hasps and pad lock on the guest room 20 entry door.
    not activeSep 12, 2014interior surfaces sectionrepair the damaged walls 1001 b, d, jin unit 19, the walls behind the door shall be properly plastered as necessary to close all gaps, cracks and holes. after repairing, this area is to be primed and painted to a durable and cleanable surface.
    not activeSep 12, 2014interior surfaces sectionreplace floor covering (1001b,j,o hc)in units 1, 2, 7, 8, 9, 17, 19, 26 and in the common hallway areas shrinkage of the wood flooring has created gaps which provide areas of potential harborage for vermin and creates an insanitary condition. this condition can not be cleaned properly. repair/restore or provide new flooring of the owner's choosing to create a smooth, durable and cleanable surface. acceptable alternatives include but are not limited to wood, tile, vct, linoleum or carpet.
    not activeSep 12, 2014interior surfaces sectionprovide adequate lighting 504g sfhcprovide a light bulb and insure the ceiling fixture works properly in unit 17.
    not activeSep 12, 2014interior surfaces sectionreplace window sash cords 1001h, 708 sfhcin unit 17, the bay of 3 windows requires sash cords in all locations.
    not activeSep 12, 2014interior surfaces sectionreplace broken window glass 1001h, 708 sfhcin the bay of 3 windows in unit 17, there are 2 panels of broken glass. replace the broken panels of glass.
    not activeSep 12, 2014interior surfaces sectionrepair the damaged ceiling 1001 b, d, jin unit 15, find and fix the source of the leak causing the ceiling to fall. the ceiling shall be properly plastered as necessary to close all gaps, cracks and holes. after repairing, this area is to be primed and painted to a durable and cleanable surface.
    not activeSep 12, 2014interior surfaces sectionremove egress obstruction 801, 1001l sfhcreduce/remove/relocate the storage of personal belongings behind the door in unit 15 to allow free and easy exiting.
    not activeSep 12, 2014interior surfaces sectionprovide adequate lighting 504g sfhcprovide a light bulb and insure the ceiling fixture works properly in unit 15.
    not activeSep 12, 2014interior surfaces sectionremove egress obstruction 801, 1001l sfhcreduce/remove/relocate the storage of personal belongings behind the door in unit 14 to allow free and easy exiting.
    not activeSep 12, 2014interior surfaces sectionprovide a working door knob 1001d, j sfhcprovide a working door knob to the guest room number 14.
    not activeSep 12, 2014security requirements sectionreplace broken glass panes 1001h, 708 sfhcreplace the broken glass panel in unit 9 window.
    not activeSep 12, 2014security requirements sectionreplace window sash cords 1001h sfhcin unit 9 replace the missing window sash cords.
    not activeSep 12, 2014security requirements sectionrepair damaged walls 1001b, d, j sfhcin unit 9 the wall shall be properly plastered as necessary to close the gaps, cracks and holes. after closing all gaps and holes, these walls are to be primed and painted to a durable and cleanable surface.
    not activeSep 12, 2014security requirements sectionrepair damaged ceilings 1001b, d, j sfhcin unit 9 the ceiling shall be properly plastered as necessary to close the gaps, cracks and holes. after closing all gaps and holes, these areas are to be primed and painted to a durable and cleanable surface.
    not activeSep 12, 2014security requirements sectionreplace window sash cords 1001h sfhcin unit 8 replace the missing window sash cords.
    not activeSep 12, 2014security requirements sectionrepair damaged ceilings 1001b, d, j sfhcin unit 8 the ceiling above the sink shall be properly plastered as necessary to close the gaps, cracks and holes. after closing all gaps and holes, these areas are to be primed and painted to a durable and cleanable surface.
    not activeSep 12, 2014security requirements sectionremove egress obstruction 801, 1001l sfhcreduce/remove/relocate the storage of personal belongings behind the door in unit 8 to allow free and easy exiting.
    not activeSep 12, 2014building sectionprovide carbon monoxide detectors detector 420 cbcprovide carbon monoxide detectors laid out per the san francisco building code section 420. there shall be one unit in each guest room within the immediate floor and each adjacent floor, above and below a gas burning appliance to include stoves, dryers, furnaces, water heaters and boilers.
    not activeSep 12, 2014security requirements sectionreplace window sash cords 1001h sfhcin unit 7 replace the missing window sash cords.
    not activeSep 12, 2014interior surfaces sectionreplace defective hot water faucet 1001f sfhcrepair/replace the hot water sink faucet in unit 7.
    not activeSep 12, 2014interior surfaces sectionrepair damaged walls 1001b, d, j sfhcin unit 7 the walls shall be properly plastered as necessary to close the gaps, cracks and holes. after closing all gaps and holes, these walls are to be primed and painted to a durable and cleanable surface.
    not activeSep 12, 2014interior surfaces sectionrepair damaged ceilings 1001b, d, j sfhcin unit 7 the ceiling shall be properly plastered as necessary to close the gaps, cracks and holes. after closing all gaps and holes, these areas are to be primed and painted to a durable and cleanable surface.
    not activeMar 9, 2022
    building section · this notice includes violations for the areas noted.
    284 golden gate st. apt#18
    not activeMar 9, 2022
    other section · provide heat to each occupied habitable sro room for 13 hrs between 5:00 a.m. and 11:00 a.m. and between 3:00 p.m. and 10:00 p.m. capable to maintaining a min. room temp. of 68 degrees f. (20 degrees c.). (701c hc)
    no heat source was found in unit during inspection. provide heat per the housing code minimium requirements.
    not activeMar 9, 2022
    other section · inspector comments
    nuisance (401(2) (1001(d) hc) it is the property owner's responsibility to be present or direct his/her representative to attend the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection time/date with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b)), if any dwellings, apartment units or guest rooms are to be accessed during the reinspection.
    not activeSep 12, 2014
    building section · this notice includes violations for the areas noted.
    this notice includes violations of the san francisco housing code. unless noted otherwise, all violations were observed on the date of inspection at 284 golden gate avenue.
    not activeSep 12, 2014
    building section · repair or replace the brick chimney and flue lining 1001g sfhc
    the chimney behind the roof access penthouse has been compromised. there are partial courses of brick and sections of clay flue liner missing. repair or replace this chimney to support the mechanical systems below in an approved manner.
    not activeSep 12, 2014
    building section · building permit required (301 hc)
    you are required to obtain a building permit to correct this violation. when applying for a building permit, reference the complaint number from this notice of violation. the building inspector must perform periodic and final inspections and sign the job card before the housing division can abate this violation.
    not activeSep 12, 2014
    building section · provide weather proofing at roof (1001(h),703 hc)
    the roof access penthouse roofing material is re-directing water into the flue of the brick chimney. once the conditions of the chimney have been resolved a weather proof roofing condition shall be offered to correct this problem.
    not activeSep 12, 2014
    plumbing and electrical section · make necessary repairs to shower 1001f sfhc
    the third floor shower has a crack through the fiberglass material causing a leak situation. repair, restore or replace the shower stall to provide a water tight finish with a sanitary, smooth, cleanable surface finish.
    not activeSep 12, 2014
    fire section · remove egress obstruction 801, 1001(l) sfhc
    remove the television and trash cans from the third floor landing. the trash cans should be in an approved indoor trash area or open to blue sky.
    not activeSep 12, 2014
    plumbing and electrical section · provide a cover plate 1001e sfhc
    in unit 22 there is an open junction box for a light switch near the sink basin. provide an approved cover plate.
    not activeSep 12, 2014
    plumbing and electrical section · repair sink (1001f hc)
    in unit 24 there is an active leak at the sink faucet and in the p trap. find the source of each leak and repair as necessary.
    not activeSep 12, 2014
    plumbing and electrical section · replace broken glass window panes 1001h, 708 sfhc
    in unit 24, replace the broken glass panel in the window.
    not activeSep 12, 2014
    plumbing and electrical section · repair window sash frame 1001h, 708 sfhc
    in unit 24, repair the window sash frame. insure that the sash and frame provide smooth and easy operation and a weather tight condition with a working latch. window is to remain at any desired open position with the balance of a counter weight.
    not activeSep 12, 2014
    plumbing and electrical section · replace window sash cords 1001h, 708 sfhc
    replace the missing/broken sash cords in unit 24.
    not activeSep 12, 2014
    plumbing and electrical section · replace the missing tile 1001b, d, j sfhc
    in the third floor toilet room there is a missing ceramic tile creating an insanitary condition that cannot be cleaned properly. replace the missing tile and finish as necessary.
    not activeSep 12, 2014
    plumbing and electrical section · replace window sash cords 1001h, 708 sfhc
    in the third floor toilet and tub room, replace the missing sash cords and counter balances. insure that the sash and frame provide smooth and easy operation and a weather tight condition with a working latch. window is to remain at any desired open position with the balance of a counter weight.
    not activeSep 12, 2014
    plumbing and electrical section · repair damaged walls 1001 b, d, h, 1301 sfhc
    in unit 25 under the window, the wall shall be properly plastered as necessary to close all gaps, cracks and holes. after repairing, these walls are to be primed and painted to a durable and cleanable surface.
    not activeSep 12, 2014
    plumbing and electrical section · repair damaged walls 1001 b, d, h, 1301 sfhc
    in unit 27 behind the door, the wall shall be properly plastered as necessary to close all gaps, cracks and holes. after repairing, these walls are to be primed and painted to a durable and cleanable surface.
    not activeSep 12, 2014
    sanitation section · repair damaged ceilings 1001 b ,d, h, 1301 sfhc
    in unit 27, the ceiling shall be properly plastered as necessary to close all gaps, cracks and holes. after repairing, these areas are to be primed and painted to a durable and cleanable surface.
    not activeSep 12, 2014
    sanitation section · repair the leaking faucet 1001f sfhc
    in unit 27 the hot water faucet has a steady stream with the faucet handle turned all the way off. repair or replace the faucet as necessary.
    not activeSep 12, 2014
    sanitation section · repair the leaking faucet 1001f sfhc
    in unit 17 the hot water supply line has a leak. repair or replace this supply line as necessary to fix the leak.
    not activeSep 12, 2014
    sanitation section · provide adequate lighting 504g sfhc
    in the south end of the hallway of the third floor near the fire escape, there is a missing light bulb. replace the light bulb to provide adequate lighting to this area.
    not activeSep 12, 2014
    sanitation section · provide adequate lighting 504g sfhc
    provide a fixture at the landing between the second and third floor to provide adequate lighting to this area.
    not activeSep 12, 2014
    sanitation section · remove the unsecured carpet 1001b, d, j sfhc
    the loose area rugs at the top of the stairs create a trip hazard. remove the area rugs and provide a secured, durable and cleanable floor surface.
    not activeSep 12, 2014
    sanitation section · repair damaged ceilings 1001 b ,d, h, 1301 sfhc
    in unit 26, the ceiling shall be properly plastered as necessary to close all gaps, cracks and holes. after repairing, these areas are to be primed and painted to a durable and cleanable surface.
    not activeSep 12, 2014
    sanitation section · repair damaged walls 1001 b ,d, h, 1301 sfhc
    in unit 26, the walls around the p trap shall be properly plastered as necessary to close all gaps, cracks and holes. after repairing, this area is to be primed and painted to a durable and cleanable surface.
    not activeSep 12, 2014
    sanitation section · replace the broken weather stripping 1001d sfhc
    at the front door to guest room 26, replace the broken weather stripping.
    not activeSep 12, 2014
    sanitation section · remove the egress obstruction 801, 1001l sfhc
    remove the hasps and pad lock on the guest room 20 entry door.
    not activeSep 12, 2014
    interior surfaces section · repair the damaged walls 1001 b, d, j
    in unit 19, the walls behind the door shall be properly plastered as necessary to close all gaps, cracks and holes. after repairing, this area is to be primed and painted to a durable and cleanable surface.
    not activeSep 12, 2014
    interior surfaces section · replace floor covering (1001b,j,o hc)
    in units 1, 2, 7, 8, 9, 17, 19, 26 and in the common hallway areas shrinkage of the wood flooring has created gaps which provide areas of potential harborage for vermin and creates an insanitary condition. this condition can not be cleaned properly. repair/restore or provide new flooring of the owner's choosing to create a smooth, durable and cleanable surface. acceptable alternatives include but are not limited to wood, tile, vct, linoleum or carpet.
    not activeSep 12, 2014
    interior surfaces section · provide adequate lighting 504g sfhc
    provide a light bulb and insure the ceiling fixture works properly in unit 17.
    not activeSep 12, 2014
    interior surfaces section · replace window sash cords 1001h, 708 sfhc
    in unit 17, the bay of 3 windows requires sash cords in all locations.
    not activeSep 12, 2014
    interior surfaces section · replace broken window glass 1001h, 708 sfhc
    in the bay of 3 windows in unit 17, there are 2 panels of broken glass. replace the broken panels of glass.
    not activeSep 12, 2014
    interior surfaces section · repair the damaged ceiling 1001 b, d, j
    in unit 15, find and fix the source of the leak causing the ceiling to fall. the ceiling shall be properly plastered as necessary to close all gaps, cracks and holes. after repairing, this area is to be primed and painted to a durable and cleanable surface.
    not activeSep 12, 2014
    interior surfaces section · remove egress obstruction 801, 1001l sfhc
    reduce/remove/relocate the storage of personal belongings behind the door in unit 15 to allow free and easy exiting.
    not activeSep 12, 2014
    interior surfaces section · provide adequate lighting 504g sfhc
    provide a light bulb and insure the ceiling fixture works properly in unit 15.
    not activeSep 12, 2014
    interior surfaces section · remove egress obstruction 801, 1001l sfhc
    reduce/remove/relocate the storage of personal belongings behind the door in unit 14 to allow free and easy exiting.
    not activeSep 12, 2014
    interior surfaces section · provide a working door knob 1001d, j sfhc
    provide a working door knob to the guest room number 14.
    not activeSep 12, 2014
    security requirements section · replace broken glass panes 1001h, 708 sfhc
    replace the broken glass panel in unit 9 window.
    not activeSep 12, 2014
    security requirements section · replace window sash cords 1001h sfhc
    in unit 9 replace the missing window sash cords.
    not activeSep 12, 2014
    security requirements section · repair damaged walls 1001b, d, j sfhc
    in unit 9 the wall shall be properly plastered as necessary to close the gaps, cracks and holes. after closing all gaps and holes, these walls are to be primed and painted to a durable and cleanable surface.
    not activeSep 12, 2014
    security requirements section · repair damaged ceilings 1001b, d, j sfhc
    in unit 9 the ceiling shall be properly plastered as necessary to close the gaps, cracks and holes. after closing all gaps and holes, these areas are to be primed and painted to a durable and cleanable surface.
    not activeSep 12, 2014
    security requirements section · replace window sash cords 1001h sfhc
    in unit 8 replace the missing window sash cords.
    not activeSep 12, 2014
    security requirements section · repair damaged ceilings 1001b, d, j sfhc
    in unit 8 the ceiling above the sink shall be properly plastered as necessary to close the gaps, cracks and holes. after closing all gaps and holes, these areas are to be primed and painted to a durable and cleanable surface.
    not activeSep 12, 2014
    security requirements section · remove egress obstruction 801, 1001l sfhc
    reduce/remove/relocate the storage of personal belongings behind the door in unit 8 to allow free and easy exiting.
    not activeSep 12, 2014
    building section · provide carbon monoxide detectors detector 420 cbc
    provide carbon monoxide detectors laid out per the san francisco building code section 420. there shall be one unit in each guest room within the immediate floor and each adjacent floor, above and below a gas burning appliance to include stoves, dryers, furnaces, water heaters and boilers.
    not activeSep 12, 2014
    security requirements section · replace window sash cords 1001h sfhc
    in unit 7 replace the missing window sash cords.
    not activeSep 12, 2014
    interior surfaces section · replace defective hot water faucet 1001f sfhc
    repair/replace the hot water sink faucet in unit 7.
    not activeSep 12, 2014
    interior surfaces section · repair damaged walls 1001b, d, j sfhc
    in unit 7 the walls shall be properly plastered as necessary to close the gaps, cracks and holes. after closing all gaps and holes, these walls are to be primed and painted to a durable and cleanable surface.
    not activeSep 12, 2014
    interior surfaces section · repair damaged ceilings 1001b, d, j sfhc
    in unit 7 the ceiling shall be properly plastered as necessary to close the gaps, cracks and holes. after closing all gaps and holes, these areas are to be primed and painted to a durable and cleanable surface.