stoop
MAP
LeaderboardAbout

281 TURK ST

Tenderloin · San Francisco, CA · Parcel 0344006B · Last violation Jul 7, 2026 · Last complaint Jul 29, 2026

NeighborhoodTenderloin
More violations than 98% of nearby buildings
More violations than 98% of buildings and more complaints than 97% of buildings in Tenderloin. Size-normalized against residential buildings in the neighborhood.
ViolationsComplaints
Activity TrendsLast 5 years
A steady level of activity over time
Last 2 yrs: 5 violations · 13 complaints
'22'26ViolationsComplaints
Severityⓘopen violations
5 open DBI violations
Active Notices of Violation issued by the Department of Building Inspection.
Severe1
Serious2
Minor2

What to watch forⓘ

  1. Tenants here have reported no heat or no hot water.
    details ▸

    California law requires heating facilities in good working order, and plumbing facilities in good working order including hot and cold running water. A rental unit that substantially lacks either may be legally uninhabitable, which is the standard the implied warranty of habitability sets for every residential tenancy in the state.

    Ask how heat and hot water are supplied and who pays for them. If either fails once you live here, put the request to the landlord in writing and keep a copy.

    • California Tenant Guide
    • San Francisco Housing Code §701
  2. Fire safety problems have been reported here.
    Worth checkingⓘ
    Walk the exit route from the unit to the street and check the stairs and hallways are clear of stored items, and that fire doors close properly.
    details ▸

    California law requires safe fire or emergency exits leading to a street or hallway, and requires stairs, hallways and exits to be kept litter free. Storage areas, garages and basements must be kept free of combustible materials. San Francisco's Housing Code separately treats inadequate exits and inadequate fire protection equipment as conditions that make a building substandard, which is the finding behind a notice of violation.

311 Housing Complaints
Total complaints since 2022
17
3 per year avg.↑ Up 333% in the last 2 years (13 vs 3 prior 2 yrs)
Complaint severity
Last 5 years
17
Severeⓘ7
Seriousⓘ8
Minorⓘ2
Dept. of Building Inspection Violations
Total violations since 1997
98
3 per year avg.↓ Down 69% in the last 2 years (5 vs 16 prior 2 yrs)
Open violations
5
Severeⓘ1
Seriousⓘ2
Minorⓘ2

Top violation categories

5 yrsAll time
Exterior & windowsⓘ3 violations
Heating equipmentⓘ3 violations
Smoke detectorsⓘ2 violations
Fire safetyⓘ2 violations
Heat / hot waterⓘ2 violations
Walls, ceilings & cabinetsⓘ2 violations
Cleanliness & refuseⓘ1 violations
Moldⓘ1 violations
No specific condition stated9 violations
2 still open. See violation log below.

Top complaint types

5 yrsAll time
Heat Lack Of Heat4 complaints
Mold And Mildew3 complaints
Infestation Rodent Insect2 complaints
Plumbing Broken Leaking2 complaints
Hot Water Lack Of Hot Water2 complaints
Security Inadequately Secured Perimeter1 complaints
Garbage Receptacles1 complaints
General Maintenance Not In List Above1 complaints
Fire Alarm System1 complaints
Hide violations (98) ↑See complaints (17) →

Violation log

98 DBI violations

AllOpenClosed
StatusFiledCategoryItemNOV Item Description
not activeMay 19, 2017building sectionrepair window glazing seal (1001(h),(j),& 708 hc)replace all broken or cracked window glass including: 1) one pane of glass at the bay window located on the right.
See something wrong? File a complaint with SF 311
  • California Tenant Guide
  • San Francisco Housing Code §1001(m), (n)
  • Tenants here have reported mold.
    Worth checkingⓘ
    Look for dark spots on walls, floors and ceilings, and for dry or wet spots, flaking or bubbling, or a damp or moldy smell, especially in bathrooms and closets.
    details ▸

    San Francisco's Health Code treats visible or otherwise demonstrable mold or mildew in a residential building as a public health nuisance in its own right. Under state law, mold that the landlord has notice of and that affects livability or health can also breach the implied warranty of habitability.

    • California Tenant Guide
    • San Francisco Health Code §581(b)(6)
  • not activeMay 19, 2017plumbing and electrical sectionrepair electrical outlet (1001e hc)repair or replace the loose, defective electrical outlet located at the kitchen sink counter top.
    not activeMay 19, 2017plumbing and electrical sectionrepair lightswitch (1001e hc)repair or replace the defective pull chain ceiling light fixture located in the closet. an electrical permit is required if replacing with a switched light fixture. provide a copy of all completed permits to the housing inspector at the time of re-inspection.
    not activeMay 19, 2017other sectioninspector commentsit is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection. important note: due to the violations noted, this property is defined as a nuisance per sec. 1001-d of the sfhc. please review the attached "notice of violation warnings" for information regarding failure to comply with this notice.
    not activeJul 27, 2016building sectionthis notice includes violations for the areas noted.this notice includes violations of the san francisco housing code. unless noted otherwise, all violations were observed on the date of inspection at 281 turk street, in the common areas.
    not activeJul 27, 2016building sectionprovide 604 affidavit for all exterior appendages 604, 908 sfhcprovide a signed and completed 604 affidavit from a licensed professional to certify the functionality of your fire escapes and all other exterior appendages. provide completed form at inspection or return by mail to: department of building inspection housing division, c. grady 1660 mission street, 6th floor san francisco, ca 94102
    not activeJul 27, 2016building sectionprovide carbon monoxide detectors 420 cbc provide smoke detectors 908, 911 sfhc, 907.2.11 sfbcprovide carbon monoxide detectors laid out per the san francisco building code section 420. there shall be one unit in each guest room within the immediate floor and each adjacent floor, above and below a gas burning appliance to include stoves, dryers, furnaces, water heaters and boilers. install smoke detectors as required by the san francisco building code. a self-certification form has been included for your convenience. provide completed form at inspection or return by mail to: department of building inspection housing division, c. grady 1660 mission street, 6th floor san francisco, ca 94102
    not activeJul 27, 2016building sectionrepair the smoke enclosure door 707, 807 sfhcthe smoke enclosure door on the second floor of the rear exit stair has torn away from the jamb. the leading edge is dragging on the the striker side jamb and the bottom of the door is dragging on the threshold. repair the door to provide smooth and easy operation with a self closing and self latching close.
    not activeJul 27, 2016plumbing and electrical sectionelectrical permits are required article 89.108.4.1 cec, 301 sfhcthe auxillary light, service light fixture, oversized juntion box and conduit at the rear stair at the third floor entry door is work requiring a permit. permit research shows no permits are in place. you are required to obtain an electrical permit to correct this violation. when applying for an electrical permit, reference the complaint number from this notice of violation. the electrical inspector must perform periodic and final inspections and sign the job card before the housing division can abate this violation. present the signed job card indicating that work is complete to the housing inspector on the date of re-inspection.
    not activeJul 27, 2016other sectioninspector commentsimportant note: due to the nature of this violation, this property has been defined as a nuisance per section 1001-d of the san francisco housing code. it is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection.
    not activeNov 8, 2013building sectionthis notice includes violations for the areas noted.285 turk street apartment #202
    not activeNov 8, 2013smoke detection sectionreplace smoke detector (908, 911 hc)in main room in apartment #202
    not activeNov 8, 2013plumbing and electrical sectionrepair light (1001e hc)replace missing light cover in kitchen in apartment #202
    not activeNov 8, 2013sanitation sectioneliminate bedbug infestation (1001b, 1306 hc)you are required to follow the guidlines pursuant article 11, section 581 of san francisco health code. pco report must be presented at time of reinspection, no exceptions.
    not activeNov 8, 2013other sectioninspector commentsinspector comments regarding "follow up" reinspection: i have scheduled a reinspection of your building on monday, 23-december-2013 at 1:30 pm. reinspection of premise to include all areas referenced above. please contact inspector galvis to confirm appointment at 415-558-6513. it is the property owners responsibility to be present or direct his/her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector. on scheduled reinspection day, provide the inspector with a full access to all common and public areas per attached checklist. your cooperation is appreciated.
    not activeApr 26, 2013Heating equipment—No permit to operate the boiler. serial no G0038247, CMC 1022
    not activeNov 3, 2010Heating equipment—OPERATE THE BOILER SN# G0038247. CMC 1022.0
    not activeNov 3, 2010Heating equipment—No permit to operate the boiler. CMC 1023
    not activeJun 20, 2008other sectioninspectionsit is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to those areas not accessed during the initial inspection and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to reschedule with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303 (b) if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection.
    not activeJun 20, 2008building sectionprovide boiler or pressure vessel operating permit. sfmc 1024.0.permit to operate shall be displayed in a conspicuous place adjacent to the boiler or vessel. apply to sf dbi plumbing inspection division.
    not activeJun 20, 2008building sectionprovide means of egress identification (exit signs) at door opening into exit stairs leaving basement and leading to lobby. sfbc 1003.2.8—
    not activeJun 20, 2008building sectionprovide fire sprinkler protection at all basement storage areas. sfhc 904.—
    not activeMay 22, 2008other sectioninspectionsit is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to those areas not accessed during the initial inspection and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to reschedule with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303 (b) if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection.
    not activeMay 22, 2008building sectionprovide for the fire escape(s) a written report from a qualified service contractor/company stating that all components have been tested and are functional as required or demonstrate proper function of fire escape ladder. sfhc 908.—
    not activeMay 22, 2008building sectionprovide access for roof inspection. sfhc 303(a).health and safety inspections will be made on a periodic basis as determined by the director of the department of building inspection.
    not activeMay 22, 2008building sectionprovide access for utilities shutoff inspections. sfhc 303(a).health and safety inspections will be made on a periodic basis as determined by the director of the department of building inspection.
    not activeMay 22, 2008building sectionremove all items obstructing egress at the secondary means of egress. sfhc 801.—
    not activeMay 22, 2008building sectionprovide door closing device at exterior door/gate. sfhc 706 (b)(1), 706 (b)(4).exterior doors/gates shall be self closing, tight fitting, burglar resistant, continuously locked but openable from inside without special effort, knowledge, or key.
    not activeNov 10, 2005building sectionpainting required at hallway and kitchen walls and ceiling surfaces.(1001, 1301 hc)remove,contain and properly dispose of peeling paint and plaster in the entry hallway and kitchen areas of apt #204.
    not activeNov 10, 2005interior surfaces sectiondisturbing lead based paint can be extremely dangerous to dwelling occupants and visitors, particularly to young children, pregnant women, pets, and to people performing work on the premises. for interior or exterior paint removal : always wet the surface, contain and properly dispose of leaded paint. if you are unsure whether the paint is leaded, you should test it prior to performing any work. if the paint is found to contain lead, you should consult with an expert about appropriate procedures. proper containment and 3-day notification is required for exterior jobs of more than 10 sq.ft. (sec.3604, sfbc) informational packets are available at (415) 558-6088. you can contact the san francisco childhood lead poisoning prevention program at: (415) 554-8930 for free advice. if you cause lead dust to be created, you could be liable for any illness caused by the dust. ordinance #446-97.—
    not activeNov 10, 2005building sectionrepair plumbing,unstop bathroom sink in apt #204.1001hc.stoped up bathroom lavatory,creating a potential overflow.
    not activeNov 10, 2005building sectionreglaze chiped,peeling bath tub in apt #204. 1001hc.previously refaced bath tub is in need to be cleaned and reglazed .
    not activeSep 20, 2005building sectionreplace floor covering (1001b,j,o hc)1)repair/replace buckling floor surfaces in the hallway area . 2)replace bed bug infested ripped carpeting,throughout the premises.1001hc.
    not activeSep 20, 2005building sectionpainting required at walls and ceiling surfaces in apt #208.(1001, 1301 hc)1)remove,contain and properly dispose of peeling paint along studio walls and ceilings in apt #208.1001hc. 2)replaster and paint premises throughout,including kitchen and bathroom areas.1001hc./1301hc.
    not activeSep 20, 2005building sectionreplace kitchen floor covering under the refrigirator. (1001b,j,o hc)replace worn,damaged kitchen floor covering under th unit,in apt #208.
    not activeSep 20, 2005building sectionleaking refrigirator.repair,service,replace leaking refrigirator unit.1001hc.
    not activeSep 20, 2005building sectiondefective splash back behind kitchen counter top.1001hc.properly secure,caulk and repair splash back behind kitchen counter top.1001hc.
    not activeSep 20, 2005building sectionpest and bed bug infestation throughout the premises.(tenant has multiple bites on her body.)provide licensed pest control measures until bed bug infestation is under control.1001hc.
    not activeJan 20, 2004building sectionwater heaters in need to be secured.1)properly strap and secure water heaters. 2)install a run off to water heater unit.1001hc.
    not activeJan 20, 2004building sectiondefective handrail to rear stairs on 6th floor.repair defective 6th floor handrail.1001hc.
    not activeJan 20, 2004building sectionlack of sprinklers coverage to garbage storage area.install requiered sprinkler heads over garbage storage area.(plumbing sprinkler required.)1001hc.
    not activeJan 20, 2004building sectionegress obstruction at rear secondary stairs.remove boxes,bags, at rear secondary stairs,constituting an egress obstruction.801hc.
    not activeDec 1, 2000building sectionleaking skylight over laundry room area.repair leaking skylight over laundry room.1001hc.
    not activeDec 1, 2000building sectionlack of sprinkle coverage over garbage storage area.install sprinkle coverage over garbage cans on each landing. (plumbing permit requiered.)1001hc.
    not activeMay 1, 2000building sectiondebries in the lightwell/garbage storage areaclean and desinfect lightwell /garbage storage area.1306hc.
    not activeAug 25, 1997other sectionpost enclosed gas meter instructional diagram in a public area. (712 hc)at gas meters.
    not activeAug 25, 1997other sectionprovide shutoff tool for gas utility shutoff (712 hc)at gas meters.
    not activeAug 25, 1997other sectioninspector commentsperform work within 15 days, no reinspection required. return enclosed affadavit when when work is completed within specified period.
    not activeMay 19, 2017
    building section · repair window glazing seal (1001(h),(j),& 708 hc)
    replace all broken or cracked window glass including: 1) one pane of glass at the bay window located on the right.
    not activeMay 19, 2017
    plumbing and electrical section · repair electrical outlet (1001e hc)
    repair or replace the loose, defective electrical outlet located at the kitchen sink counter top.
    not activeMay 19, 2017
    plumbing and electrical section · repair lightswitch (1001e hc)
    repair or replace the defective pull chain ceiling light fixture located in the closet. an electrical permit is required if replacing with a switched light fixture. provide a copy of all completed permits to the housing inspector at the time of re-inspection.
    not activeMay 19, 2017
    other section · inspector comments
    it is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection. important note: due to the violations noted, this property is defined as a nuisance per sec. 1001-d of the sfhc. please review the attached "notice of violation warnings" for information regarding failure to comply with this notice.
    not activeJul 27, 2016
    building section · this notice includes violations for the areas noted.
    this notice includes violations of the san francisco housing code. unless noted otherwise, all violations were observed on the date of inspection at 281 turk street, in the common areas.
    not activeJul 27, 2016
    building section · provide 604 affidavit for all exterior appendages 604, 908 sfhc
    provide a signed and completed 604 affidavit from a licensed professional to certify the functionality of your fire escapes and all other exterior appendages. provide completed form at inspection or return by mail to: department of building inspection housing division, c. grady 1660 mission street, 6th floor san francisco, ca 94102
    not activeJul 27, 2016
    building section · provide carbon monoxide detectors 420 cbc provide smoke detectors 908, 911 sfhc, 907.2.11 sfbc
    provide carbon monoxide detectors laid out per the san francisco building code section 420. there shall be one unit in each guest room within the immediate floor and each adjacent floor, above and below a gas burning appliance to include stoves, dryers, furnaces, water heaters and boilers. install smoke detectors as required by the san francisco building code. a self-certification form has been included for your convenience. provide completed form at inspection or return by mail to: department of building inspection housing division, c. grady 1660 mission street, 6th floor san francisco, ca 94102
    not activeJul 27, 2016
    building section · repair the smoke enclosure door 707, 807 sfhc
    the smoke enclosure door on the second floor of the rear exit stair has torn away from the jamb. the leading edge is dragging on the the striker side jamb and the bottom of the door is dragging on the threshold. repair the door to provide smooth and easy operation with a self closing and self latching close.
    not activeJul 27, 2016
    plumbing and electrical section · electrical permits are required article 89.108.4.1 cec, 301 sfhc
    the auxillary light, service light fixture, oversized juntion box and conduit at the rear stair at the third floor entry door is work requiring a permit. permit research shows no permits are in place. you are required to obtain an electrical permit to correct this violation. when applying for an electrical permit, reference the complaint number from this notice of violation. the electrical inspector must perform periodic and final inspections and sign the job card before the housing division can abate this violation. present the signed job card indicating that work is complete to the housing inspector on the date of re-inspection.
    not activeJul 27, 2016
    other section · inspector comments
    important note: due to the nature of this violation, this property has been defined as a nuisance per section 1001-d of the san francisco housing code. it is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection.
    not activeNov 8, 2013
    building section · this notice includes violations for the areas noted.
    285 turk street apartment #202
    not activeNov 8, 2013
    smoke detection section · replace smoke detector (908, 911 hc)
    in main room in apartment #202
    not activeNov 8, 2013
    plumbing and electrical section · repair light (1001e hc)
    replace missing light cover in kitchen in apartment #202
    not activeNov 8, 2013
    sanitation section · eliminate bedbug infestation (1001b, 1306 hc)
    you are required to follow the guidlines pursuant article 11, section 581 of san francisco health code. pco report must be presented at time of reinspection, no exceptions.
    not activeNov 8, 2013
    other section · inspector comments
    inspector comments regarding "follow up" reinspection: i have scheduled a reinspection of your building on monday, 23-december-2013 at 1:30 pm. reinspection of premise to include all areas referenced above. please contact inspector galvis to confirm appointment at 415-558-6513. it is the property owners responsibility to be present or direct his/her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector. on scheduled reinspection day, provide the inspector with a full access to all common and public areas per attached checklist. your cooperation is appreciated.
    not activeApr 26, 2013
    Heating equipment
    No permit to operate the boiler. serial no G0038247, CMC 1022
    not activeNov 3, 2010
    Heating equipment
    OPERATE THE BOILER SN# G0038247. CMC 1022.0
    not activeNov 3, 2010
    Heating equipment
    No permit to operate the boiler. CMC 1023
    not activeJun 20, 2008
    other section · inspections
    it is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to those areas not accessed during the initial inspection and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to reschedule with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303 (b) if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection.
    not activeJun 20, 2008
    building section · provide boiler or pressure vessel operating permit. sfmc 1024.0.
    permit to operate shall be displayed in a conspicuous place adjacent to the boiler or vessel. apply to sf dbi plumbing inspection division.
    not activeJun 20, 2008
    building section · provide means of egress identification (exit signs) at door opening into exit stairs leaving basement and leading to lobby. sfbc 1003.2.8
    not activeJun 20, 2008
    building section · provide fire sprinkler protection at all basement storage areas. sfhc 904.
    not activeMay 22, 2008
    other section · inspections
    it is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to those areas not accessed during the initial inspection and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to reschedule with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303 (b) if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection.
    not activeMay 22, 2008
    building section · provide for the fire escape(s) a written report from a qualified service contractor/company stating that all components have been tested and are functional as required or demonstrate proper function of fire escape ladder. sfhc 908.
    not activeMay 22, 2008
    building section · provide access for roof inspection. sfhc 303(a).
    health and safety inspections will be made on a periodic basis as determined by the director of the department of building inspection.
    not activeMay 22, 2008
    building section · provide access for utilities shutoff inspections. sfhc 303(a).
    health and safety inspections will be made on a periodic basis as determined by the director of the department of building inspection.
    not activeMay 22, 2008
    building section · remove all items obstructing egress at the secondary means of egress. sfhc 801.
    not activeMay 22, 2008
    building section · provide door closing device at exterior door/gate. sfhc 706 (b)(1), 706 (b)(4).
    exterior doors/gates shall be self closing, tight fitting, burglar resistant, continuously locked but openable from inside without special effort, knowledge, or key.
    not activeNov 10, 2005
    building section · painting required at hallway and kitchen walls and ceiling surfaces.(1001, 1301 hc)
    remove,contain and properly dispose of peeling paint and plaster in the entry hallway and kitchen areas of apt #204.
    not activeNov 10, 2005
    interior surfaces section · disturbing lead based paint can be extremely dangerous to dwelling occupants and visitors, particularly to young children, pregnant women, pets, and to people performing work on the premises. for interior or exterior paint removal : always wet the surface, contain and properly dispose of leaded paint. if you are unsure whether the paint is leaded, you should test it prior to performing any work. if the paint is found to contain lead, you should consult with an expert about appropriate procedures. proper containment and 3-day notification is required for exterior jobs of more than 10 sq.ft. (sec.3604, sfbc) informational packets are available at (415) 558-6088. you can contact the san francisco childhood lead poisoning prevention program at: (415) 554-8930 for free advice. if you cause lead dust to be created, you could be liable for any illness caused by the dust. ordinance #446-97.
    not activeNov 10, 2005
    building section · repair plumbing,unstop bathroom sink in apt #204.1001hc.
    stoped up bathroom lavatory,creating a potential overflow.
    not activeNov 10, 2005
    building section · reglaze chiped,peeling bath tub in apt #204. 1001hc.
    previously refaced bath tub is in need to be cleaned and reglazed .
    not activeSep 20, 2005
    building section · replace floor covering (1001b,j,o hc)
    1)repair/replace buckling floor surfaces in the hallway area . 2)replace bed bug infested ripped carpeting,throughout the premises.1001hc.
    not activeSep 20, 2005
    building section · painting required at walls and ceiling surfaces in apt #208.(1001, 1301 hc)
    1)remove,contain and properly dispose of peeling paint along studio walls and ceilings in apt #208.1001hc. 2)replaster and paint premises throughout,including kitchen and bathroom areas.1001hc./1301hc.
    not activeSep 20, 2005
    building section · replace kitchen floor covering under the refrigirator. (1001b,j,o hc)
    replace worn,damaged kitchen floor covering under th unit,in apt #208.
    not activeSep 20, 2005
    building section · leaking refrigirator.
    repair,service,replace leaking refrigirator unit.1001hc.
    not activeSep 20, 2005
    building section · defective splash back behind kitchen counter top.1001hc.
    properly secure,caulk and repair splash back behind kitchen counter top.1001hc.
    not activeSep 20, 2005
    building section · pest and bed bug infestation throughout the premises.(tenant has multiple bites on her body.)
    provide licensed pest control measures until bed bug infestation is under control.1001hc.
    not activeJan 20, 2004
    building section · water heaters in need to be secured.
    1)properly strap and secure water heaters. 2)install a run off to water heater unit.1001hc.
    not activeJan 20, 2004
    building section · defective handrail to rear stairs on 6th floor.
    repair defective 6th floor handrail.1001hc.
    not activeJan 20, 2004
    building section · lack of sprinklers coverage to garbage storage area.
    install requiered sprinkler heads over garbage storage area.(plumbing sprinkler required.)1001hc.
    not activeJan 20, 2004
    building section · egress obstruction at rear secondary stairs.
    remove boxes,bags, at rear secondary stairs,constituting an egress obstruction.801hc.
    not activeDec 1, 2000
    building section · leaking skylight over laundry room area.
    repair leaking skylight over laundry room.1001hc.
    not activeDec 1, 2000
    building section · lack of sprinkle coverage over garbage storage area.
    install sprinkle coverage over garbage cans on each landing. (plumbing permit requiered.)1001hc.
    not activeMay 1, 2000
    building section · debries in the lightwell/garbage storage area
    clean and desinfect lightwell /garbage storage area.1306hc.
    not activeAug 25, 1997
    other section · post enclosed gas meter instructional diagram in a public area. (712 hc)
    at gas meters.
    not activeAug 25, 1997
    other section · provide shutoff tool for gas utility shutoff (712 hc)
    at gas meters.
    not activeAug 25, 1997
    other section · inspector comments
    perform work within 15 days, no reinspection required. return enclosed affadavit when when work is completed within specified period.
    Page 2 of 2
    ← Prev