317 LEAVENWORTH ST

Tenderloin · San Francisco, CA · Parcel 0334005 · Last violation Oct 28, 2026 · Last complaint Nov 15, 2026

NeighborhoodTenderloin
More violations than 84% of nearby buildings
More violations than 84% of buildings and more complaints than 92% of buildings in Tenderloin. Size-normalized against residential buildings in the neighborhood.
ViolationsComplaints
Activity TrendsLast 5 years
A steady level of activity over time
Last 2 yrs: 16 violations · 20 complaints
'21'26ViolationsComplaints
Severityⓘopen violations
1 open fire-safety violation
Active Notices of Violation issued by the Department of Building Inspection.
Severe1
Serious10
Minor5

What to watch forⓘ

  1. Tenants here have reported no heat or no hot water.
    details ▸

    California law requires heating facilities in good working order, and plumbing facilities in good working order including hot and cold running water. A rental unit that substantially lacks either may be legally uninhabitable, which is the standard the implied warranty of habitability sets for every residential tenancy in the state.

    Ask how heat and hot water are supplied and who pays for them. If either fails once you live here, put the request to the landlord in writing and keep a copy.

    • California Tenant Guide
    • San Francisco Housing Code §701
  2. Fire safety problems have been reported here.
    Worth checkingⓘ
    Walk the exit route from the unit to the street and check the stairs and hallways are clear of stored items, and that fire doors close properly.
    details ▸

    California law requires safe fire or emergency exits leading to a street or hallway, and requires stairs, hallways and exits to be kept litter free. Storage areas, garages and basements must be kept free of combustible materials. San Francisco's Housing Code separately treats inadequate exits and inadequate fire protection equipment as conditions that make a building substandard, which is the finding behind a notice of violation.

311 Housing Complaints
Total complaints since 2010
89
5 per year avg.→ Stable in the last 2 years
Complaint severity
Last 5 years
39
Severeⓘ8
Seriousⓘ20
Minorⓘ11
Dept. of Building Inspection Violations
Total violations since 2000
123
5 per year avg.↑ Up 300% in the last 2 years (16 vs 4 prior 2 yrs)
Open violations
16
Severeⓘ1
Seriousⓘ10
Minorⓘ5

Top violation categories

5 yrsAll time
Electricalⓘ3 violations
Fire safetyⓘ2 violations
Peeling paintⓘ1 violations
Pestsⓘ1 violations
Plumbingⓘ1 violations
Locks & securityⓘ1 violations
Smoke detectorsⓘ1 violations
Exterior & windowsⓘ1 violations
Heat / hot waterⓘ1 violations
Walls, ceilings & cabinetsⓘ1 violations
No specific condition stated7 violations
5 still open. See violation log below.

Top complaint types

5 yrsAll time
Infestation Rodent Insect13 complaints
Heat Lack Of Heat6 complaints
Electrical Non Hazard3 complaints
General Maintenance Not In List Above3 complaints
Clutter Hoarder Unit Interior Storage3 complaints
Doors Windows Broken Defective3 complaints
Elevators Everthing Else2 complaints
Paint Peeling1 complaints
Fire Hazard1 complaints
Garbage Receptacles1 complaints
Infestation Bed Bugs1 complaints
Mold And Mildew1 complaints
Blocked Exit Common Areas1 complaints
Hide violations (123) ↑See complaints (89) →

Violation log

123 DBI violations

AllOpenClosed
StatusFiledCategoryItemNOV Item Description
not activeOct 28, 2014building sectionprevent migration 3425.4.3 sfbconce containment barriers and ground protection are in place, establish a restricted work area using 6 millimeter visquene providing full containment to prevent the migration of work debris outside the work area. all windows, doors and vents within 10 feet of work area must be covered and sealed. debris shall be double bagged and duct taped and disposed of in an approved manner. lead debris is a toxic hazard and must be disposed of as such.
See something wrong? File a complaint with SF 311
  • California Tenant Guide
  • San Francisco Housing Code §1001(m), (n)
  • Smoke detector problems have been reported here.
    Worth checkingⓘ
    Look for a smoke detector in each bedroom and in the common stairwell, and for a carbon monoxide detector if the unit has a gas stove, a gas heater or an attached garage.
    details ▸

    California law requires working smoke detectors in all bedrooms and other designated areas of a rental unit, and apartment complexes must also have them in common stairwells. Any unit with appliances that burn fossil fuels such as natural gas, propane or fuel oil, or with an attached garage, must also have working carbon monoxide detectors.

    • California Tenant Guide
  • not activeOct 28, 2014building sectioninterior work clean up standards 3425.4.4.2 sfbcat the completion of work, remove all visible work debris from the regulated area. such efforts shall include but not be limited to hepa vacuum cleaning and wet clean with detergent any exposed interior horizontal surfaces in the regulated areas.
    not activeOct 28, 2014other sectioninspector commentsnote: in addition to the regulation established by the city and county of san francisco, work that disturbs lead based paint is also regulated by the epa, the state of california health department, calosha, and the contractors state license board. fines are in excess of $37,500 per violation. please be advised to comply with all regulations governing the disturbance of lead based paint. use only approved methods and lead abatement certified contractors for the balance of this work handling lead based paint, dust and debris. it is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection.
    not activeNov 8, 2013building sectionthis notice includes violations for the areas noted.unless otherwise noted, all violation were witnessed at the verona hotel, 317 leavenworth street, in the basement.
    not activeNov 8, 2013building sectionreplace the damaged ceilings (1001 b, d hc)remove the marked areas of ceiling that have sewage stains to include all damage, miscellaneous patches of drywall and contaminated plaster. the replacement of this surface involves a fire rated assembly that shall be replaced by a licensed contractor and inspected by a building inspector through the department of building inspection's permit process.
    not activeNov 8, 2013building sectionsanitation (1306 hc)all concrete and brick walls and floor areas involved in the basement shall be cleaned, sanitized from the filth and raw sewage evident from deferred maintenance and faulty piping.
    not activeNov 8, 2013building sectionbuilding permit required (301 hc)you are required to obtain a building permit to correct this violation. apply for a building permit along with a copy of this notice of violation and reference the complaint number. the building inspector must perform periodic and final inspections and sign the job card, before the housing inspector can abate this violation. present the signed job card indicating that work is complete to the housing inspector on the re-inspection day.
    not activeNov 8, 2013plumbing and electrical sectionrepair leaking pipes (1001 f, hc)the two sections of 3" soil line that penetrate the ceiling in the south east corner of the building where eddy street meets leavenworth are fatigued. the lead and oakum sections are draining onto the floor. the clean out has a temporary cap. all sections of 3" and 4" lines of lead and oakum construction shall be replaced in an approved manner with permits.
    not activeNov 8, 2013plumbing and electrical sectionremove leaking pipe (1001 f, hc)also in this same room, locate the source of the leak in the 8" abandon line penetrating the ceiling. correct the problem and remove the remaining portion of abandon pipe to elimnate future problems.
    not activeNov 8, 2013plumbing and electrical sectionrepair deteriorated drainage pipes(1001f hc)moving from this main room one room north and one room west, repair the 2" copper p trap leaking from above.
    not activeNov 8, 2013plumbing and electrical sectionrepair deteriorated drainage pipes (1001f hc)cap the open end or remove the remaining section of second abandon 8" line.
    not activeNov 8, 2013plumbing and electrical sectionprovide plumbing permit (103.1.1 pc)you are required to obtain a building permit to correct this violation. apply for a building permit along with a copy of this notice of violation and reference the complaint number. the building inspector must perform periodic and final inspections and sign the job card, before the housing inspector can abate this violation. present the signed job card indicating that work is complete to the housing inspector on the re-inspection day.
    not activeNov 8, 2013plumbing and electrical sectionprovide electrical permit (90.25 ec)you are required to obtain an electrical permit to correct this violation. apply for a electrical permit along with a copy of this notice of violation and reference the complaint number. the electrical inspector must perform periodic and final inspections and sign the job card, before the housing inspector can abate this violation. present the signed job card indicating that work is complete to the housing inspector on the re-inspection day.
    not activeNov 8, 2013plumbing and electrical sectionrepair electrical outlet (1001e hc)there are a number of junction boxes in the basenment that have been tampered with since their last electrical inspection. covers are off and wires are proud of their junction boxes. wiring is to be corrected. do not close up these boxes until they have been ionspected. secure permits which include for rough electrical inspection and final inspection to insure that wiring in these areas meets current electrical code.
    not activeNov 8, 2013building sectionreinforce floor framing (1001(3)hc)there is a framed opening that has been covered with a subfloor without the benefit of supporting framing below. once the contaminated drywall and plaster have been removed the entire floor diaphragm is to be reframed in an approved manner to sufficiently carry the imposed loads it will be subjected to in ordinary use.
    not activeNov 8, 2013other sectioninspector commentsit is the property owner's responsibility to be present or direct his/ her representative to attend, the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/ or to provide access to all areas cited within this notice. provide all tenants with notification as required by california civil code section 1954 san francisco housing code section 303 (b), if any dwelling, apartment units or guest rooms are to be accessed during the re-inspection. important note: due to the nature of this violation, this property has been defined as a nuisance per section 1001-d of the san francisco housing code. please review the attached "notice of violation warnings" for information regarding failure to comply with this notice. all open notices of violation will be re-inspected at this time.
    not activeNov 8, 2013sanitation sectioneliminate rodent infestation (1001b, 1306 hc)there is substantial evidence of rodents in the basement. perform rodent proofing as required. cover/seal all openings. due to the large gapping in the sidewalk access point it will be necessary to provide traps. provide regular pest control by an industry professional. provide a maintenance schedule at the time of re-inspection.
    not activeMar 18, 2003Heating equipment—NPTO (2) No current Permit to Operate one H.B. Smith steam boiler. No current Permit to Operate one A.O. Smith Burkay 400,000BTUs. CMC 1024 No backflow device on the boiler make-up. CPC 603.4.11
    not activeJun 20, 2000plumbing and electrical sectionrecharge all fire extinguishers (905, 1001(m) hc)—
    not activeJun 20, 2000fire sectionrecharge all fire extinguishers (905, 1001(m) hc)—
    not activeJun 20, 2000plumbing and electrical sectionwater heaterssecure water heaters with metal straps.
    not activeJun 20, 2000other sectionpost enclosed gas meter instructional diagram in a public area. (712 hc)—
    not activeJun 20, 2000other sectionprovide shutoff tool for gas utility shutoff (712 hc)—
    not activeOct 28, 2014
    building section · prevent migration 3425.4.3 sfbc
    once containment barriers and ground protection are in place, establish a restricted work area using 6 millimeter visquene providing full containment to prevent the migration of work debris outside the work area. all windows, doors and vents within 10 feet of work area must be covered and sealed. debris shall be double bagged and duct taped and disposed of in an approved manner. lead debris is a toxic hazard and must be disposed of as such.
    not activeOct 28, 2014
    building section · interior work clean up standards 3425.4.4.2 sfbc
    at the completion of work, remove all visible work debris from the regulated area. such efforts shall include but not be limited to hepa vacuum cleaning and wet clean with detergent any exposed interior horizontal surfaces in the regulated areas.
    not activeOct 28, 2014
    other section · inspector comments
    note: in addition to the regulation established by the city and county of san francisco, work that disturbs lead based paint is also regulated by the epa, the state of california health department, calosha, and the contractors state license board. fines are in excess of $37,500 per violation. please be advised to comply with all regulations governing the disturbance of lead based paint. use only approved methods and lead abatement certified contractors for the balance of this work handling lead based paint, dust and debris. it is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection.
    not activeNov 8, 2013
    building section · this notice includes violations for the areas noted.
    unless otherwise noted, all violation were witnessed at the verona hotel, 317 leavenworth street, in the basement.
    not activeNov 8, 2013
    building section · replace the damaged ceilings (1001 b, d hc)
    remove the marked areas of ceiling that have sewage stains to include all damage, miscellaneous patches of drywall and contaminated plaster. the replacement of this surface involves a fire rated assembly that shall be replaced by a licensed contractor and inspected by a building inspector through the department of building inspection's permit process.
    not activeNov 8, 2013
    building section · sanitation (1306 hc)
    all concrete and brick walls and floor areas involved in the basement shall be cleaned, sanitized from the filth and raw sewage evident from deferred maintenance and faulty piping.
    not activeNov 8, 2013
    building section · building permit required (301 hc)
    you are required to obtain a building permit to correct this violation. apply for a building permit along with a copy of this notice of violation and reference the complaint number. the building inspector must perform periodic and final inspections and sign the job card, before the housing inspector can abate this violation. present the signed job card indicating that work is complete to the housing inspector on the re-inspection day.
    not activeNov 8, 2013
    plumbing and electrical section · repair leaking pipes (1001 f, hc)
    the two sections of 3" soil line that penetrate the ceiling in the south east corner of the building where eddy street meets leavenworth are fatigued. the lead and oakum sections are draining onto the floor. the clean out has a temporary cap. all sections of 3" and 4" lines of lead and oakum construction shall be replaced in an approved manner with permits.
    not activeNov 8, 2013
    plumbing and electrical section · remove leaking pipe (1001 f, hc)
    also in this same room, locate the source of the leak in the 8" abandon line penetrating the ceiling. correct the problem and remove the remaining portion of abandon pipe to elimnate future problems.
    not activeNov 8, 2013
    plumbing and electrical section · repair deteriorated drainage pipes(1001f hc)
    moving from this main room one room north and one room west, repair the 2" copper p trap leaking from above.
    not activeNov 8, 2013
    plumbing and electrical section · repair deteriorated drainage pipes (1001f hc)
    cap the open end or remove the remaining section of second abandon 8" line.
    not activeNov 8, 2013
    plumbing and electrical section · provide plumbing permit (103.1.1 pc)
    you are required to obtain a building permit to correct this violation. apply for a building permit along with a copy of this notice of violation and reference the complaint number. the building inspector must perform periodic and final inspections and sign the job card, before the housing inspector can abate this violation. present the signed job card indicating that work is complete to the housing inspector on the re-inspection day.
    not activeNov 8, 2013
    plumbing and electrical section · provide electrical permit (90.25 ec)
    you are required to obtain an electrical permit to correct this violation. apply for a electrical permit along with a copy of this notice of violation and reference the complaint number. the electrical inspector must perform periodic and final inspections and sign the job card, before the housing inspector can abate this violation. present the signed job card indicating that work is complete to the housing inspector on the re-inspection day.
    not activeNov 8, 2013
    plumbing and electrical section · repair electrical outlet (1001e hc)
    there are a number of junction boxes in the basenment that have been tampered with since their last electrical inspection. covers are off and wires are proud of their junction boxes. wiring is to be corrected. do not close up these boxes until they have been ionspected. secure permits which include for rough electrical inspection and final inspection to insure that wiring in these areas meets current electrical code.
    not activeNov 8, 2013
    building section · reinforce floor framing (1001(3)hc)
    there is a framed opening that has been covered with a subfloor without the benefit of supporting framing below. once the contaminated drywall and plaster have been removed the entire floor diaphragm is to be reframed in an approved manner to sufficiently carry the imposed loads it will be subjected to in ordinary use.
    not activeNov 8, 2013
    other section · inspector comments
    it is the property owner's responsibility to be present or direct his/ her representative to attend, the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/ or to provide access to all areas cited within this notice. provide all tenants with notification as required by california civil code section 1954 san francisco housing code section 303 (b), if any dwelling, apartment units or guest rooms are to be accessed during the re-inspection. important note: due to the nature of this violation, this property has been defined as a nuisance per section 1001-d of the san francisco housing code. please review the attached "notice of violation warnings" for information regarding failure to comply with this notice. all open notices of violation will be re-inspected at this time.
    not activeNov 8, 2013
    sanitation section · eliminate rodent infestation (1001b, 1306 hc)
    there is substantial evidence of rodents in the basement. perform rodent proofing as required. cover/seal all openings. due to the large gapping in the sidewalk access point it will be necessary to provide traps. provide regular pest control by an industry professional. provide a maintenance schedule at the time of re-inspection.
    not activeMar 18, 2003
    Heating equipment
    NPTO (2) No current Permit to Operate one H.B. Smith steam boiler. No current Permit to Operate one A.O. Smith Burkay 400,000BTUs. CMC 1024 No backflow device on the boiler make-up. CPC 603.4.11
    not activeJun 20, 2000
    plumbing and electrical section · recharge all fire extinguishers (905, 1001(m) hc)
    not activeJun 20, 2000
    fire section · recharge all fire extinguishers (905, 1001(m) hc)
    not activeJun 20, 2000
    plumbing and electrical section · water heaters
    secure water heaters with metal straps.
    not activeJun 20, 2000
    other section · post enclosed gas meter instructional diagram in a public area. (712 hc)
    not activeJun 20, 2000
    other section · provide shutoff tool for gas utility shutoff (712 hc)
    Page 3 of 3