stoop
MAP
LeaderboardAbout

472 ELLIS ST

Tenderloin · San Francisco, CA · Parcel 0323015 · Last violation Jul 25, 2025 · Last complaint Aug 12, 2026

NeighborhoodTenderloin
Around average violations for the neighborhood
More violations than 60% of buildings and more complaints than 70% of buildings in Tenderloin. Size-normalized against residential buildings in the neighborhood.
ViolationsComplaints
Activity TrendsLast 5 years
A steady level of activity over time
Last 2 yrs: 6 violations · 12 complaints
'21'26ViolationsComplaints
Severityⓘopen violations
All DBI violations have been resolved
Notices of Violation issued by the Department of Building Inspection, by current status.
Severe0
Serious0
Minor0

What to watch forⓘ

  1. Fire safety problems have been reported here.
    Worth checkingⓘ
    Walk the exit route from the unit to the street and check the stairs and hallways are clear of stored items, and that fire doors close properly.
    details ▸

    California law requires safe fire or emergency exits leading to a street or hallway, and requires stairs, hallways and exits to be kept litter free. Storage areas, garages and basements must be kept free of combustible materials. San Francisco's Housing Code separately treats inadequate exits and inadequate fire protection equipment as conditions that make a building substandard, which is the finding behind a notice of violation.

    • California Tenant Guide
    • San Francisco Housing Code §1001(m), (n)
  2. Tenants here have reported no heat or no hot water.
    details ▸

    California law requires heating facilities in good working order, and plumbing facilities in good working order including hot and cold running water. A rental unit that substantially lacks either may be legally uninhabitable, which is the standard the implied warranty of habitability sets for every residential tenancy in the state.

311 Housing Complaints
Total complaints since 2010
74
4 per year avg.↓ Down 25% in the last 2 years (12 vs 16 prior 2 yrs)
Complaint severity
Last 5 years
32
Severeⓘ3
Seriousⓘ20
Minorⓘ9
Dept. of Building Inspection Violations
Total violations since 1997
170
6 per year avg.↓ Down 57% in the last 2 years (6 vs 14 prior 2 yrs)
Open violations
0
No open DBI violations on record.

Top violation categories

5 yrsAll time
Fire safetyⓘ25 violations
Plumbingⓘ16 violations
Walls, ceilings & cabinetsⓘ9 violations
Heating equipmentⓘ9 violations
Peeling paintⓘ8 violations
Exterior & windowsⓘ6 violations
Cleanliness & refuseⓘ6 violations
Electricalⓘ6 violations
Smoke detectorsⓘ5 violations
Pestsⓘ5 violations
Heat / hot waterⓘ3 violations
Floors & stairsⓘ3 violations
Locks & securityⓘ2 violations
Gas shutoff & metersⓘ2 violations
Moldⓘ1 violations
No specific condition stated64 violations
See violation log below.

Top complaint types

5 yrsAll time
Hide violations (170) ↑See complaints (74) →

Violation log

170 DBI violations

AllOpenClosed
StatusFiledCategoryItemNOV Item Description
not activeJun 7, 2006security requirements sectionrepair the guest room entry door (1001 b hc).repair the damaged door, frame, and casing to the guest room entry door of #432.
See something wrong? File a complaint with SF 311

Ask how heat and hot water are supplied and who pays for them. If either fails once you live here, put the request to the landlord in writing and keep a copy.

  • California Tenant Guide
  • San Francisco Housing Code §701
  • Tenants here have reported mold.
    Worth checkingⓘ
    Look for dark spots on walls, floors and ceilings, and for dry or wet spots, flaking or bubbling, or a damp or moldy smell, especially in bathrooms and closets.
    details ▸

    San Francisco's Health Code treats visible or otherwise demonstrable mold or mildew in a residential building as a public health nuisance in its own right. Under state law, mold that the landlord has notice of and that affects livability or health can also breach the implied warranty of habitability.

    • California Tenant Guide
    • San Francisco Health Code §581(b)(6)
  • Infestation Rodent Insect19 complaints
    Mold And Mildew11 complaints
    Elevators Everthing Else10 complaints
    Infestation Bed Bugs9 complaints
    Inadequately Maintained Building Exterior5 complaints
    General Maintenance Not In List Above3 complaints
    Plumbing Broken Leaking2 complaints
    Heat Lack Of Heat2 complaints
    Fire Hazard2 complaints
    Smoke Detectors Missing Broken Common Areas1 complaints
    Deck Stairs Handrails1 complaints
    Ventilation Inadequate Or None1 complaints
    Doors Windows Broken Defective1 complaints
    Electrical Non Hazard1 complaints
    Elevators No Working Elevator 7 Or More Stories1 complaints
    Fire Alarm System1 complaints
    Hot Water Lack Of Hot Water1 complaints
    Kitchen Community1 complaints
    Paint Peeling1 complaints
    Security Inadequately Secured Perimeter1 complaints
    not activeJun 7, 2006other sectioninspector commentsit is the property owner's responsibility to be present or direct his/her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the reinspection.
    not activeJun 1, 2006other sectionprovide heat to each occupied habitable room for 13 hrs between 5:00 a.m. and 11:00 a.m. and between 3:00 p.m. and 10:00 p.m. capable to maintaining a min. room temp. of 68 degrees f. (20 degrees c.). (701c hc)there is no heat source in #356. install a radiator.
    not activeJun 1, 2006plumbing and electrical sectionrepair sink (1001f hc)repair the leaking sink drain in #356.
    not activeJun 1, 2006other sectioninspector commentsit is the property owner's responsibility to be present or direct his/her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the reinspection.
    not activeFeb 17, 2006fire sectionrepair fire proofing with approved materials (hc 1001(m), 809)there are holes in the boiler room ceiling. repair the damaged fire resistent surfaces to basement boiler room ceiling. repairs can be made with 5/8" type x drywall, 26 guage sheet metal, cement board, or equivalent. edges must be fire taped or sealed.
    not activeFeb 17, 2006fire sectionpermanently remove combustible storage or provide automatic fire sprinklers. (904, 1001(i) hc)there are combustables stored in non-sprinklered areas, including the area outside the boiler room as well as the combustable items stored in the rear yard by the commercial tenant. remove the stored items or install fire sprinklers. if installing sprinklers, provide a copy of the finaled building/plumbing permit for this work.
    not activeFeb 17, 2006building sectionrepair window latches or hardware (1001(b)hc)repair the following non-functioning windows: fire escape window near #260- broken latch;
    not activeFeb 17, 2006building sectionrepair window sash frame (1001(h),708 hc)repair the following non-functioning windows: front kitchen, second floor-fire escape window plus others won't open; fire escape window near #302, broken sash and sill; fire escape window near third floor front kitchen, won't open or latch; toilet/shower room near #304, sash is falling out; front kitchen, fourth floor fire escape window won't open or latch; toilet room window near #426;
    not activeFeb 17, 2006building sectionrepair window sash cords (1001(h) hc)replace the sash cords for the following windows: window in the first floor kitchen.
    not activeFeb 17, 2006plumbing and electrical sectionrepair toilet (1001f hc)repair the loose toilet tank in the toilet room near #448.
    not activeFeb 17, 2006plumbing and electrical sectionrepair sink (1001f hc)repair the loose faucet and sink in the rear kitchen of the third floor.
    not activeFeb 17, 2006fire sectionremove egress obstruction at (801,1001(l) hc)remove the wire hanging on the fire escape near #332.
    not activeFeb 17, 2006smoke detection sectionrepair central alarm system (908, 909 hc)the alarm panel trouble light was on at the time of inspection. have the panel serviced.
    not activeFeb 17, 2006plumbing and electrical sectionrepair the electric range burners (1001a 13 hc)repair the range burner elements in the following locations: second floor front kitchen- missing burners;
    not activeFeb 17, 2006plumbing and electrical sectionrepair the range hood fans (1001 a 13 hc)repair the range hoods in the following locations: third floor rear kitchen- missing cover, exposed fan blades, - non-functioning fan; fourth floor front kitchen- one non-functioning fan; fourth floor rear kitchen- one non-functiong fan;
    not activeFeb 17, 2006plumbing and electrical sectionremove cord wiring (1001-e hc)remove the exposed electrical wiring on the north wall of the front kitchen on the fourth floor and the rear kitchen of the third floor.
    not activeFeb 17, 2006plumbing and electrical sectionmissing appliance knobsreplace the missing knobs to the appliances in the front kitchen on the fourth floor.
    not activeFeb 17, 2006other sectionremove all hasps and eyelets from the exterior of guest room doors ( 706 (a ii) hc)remove all hasps and eyelets from the exterior of the guest room doors including the door to #500.
    not activeFeb 17, 2006building sectionrepair window glazing seal (1001(h),(j),& 708 hc)repair the broken skylight in the main light well as well as the broken skylight in the secondary light well.
    not activeFeb 17, 2006fire sectionrepair smoke enclosure door closer (807,707 hc)repair the door closers for the garbage room near #304 and the toilet room near #323.
    not activeFeb 17, 2006plumbing and electrical sectionrepair lightswitch (1001e hc)repair the loose light switch in the shower room near #242.
    not activeFeb 17, 2006other sectionit is the property owner's responsibility to be present or direct his/her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the reinspection.—
    not activeFeb 2, 2006security requirements sectionreplace damged entry door (706 hc).the latch side stile of the rear entry door near #232 has been broken, repaired, and broken many times. replace or repair the damaged door.
    not activeFeb 2, 2006security requirements sectionprovide single cylinder deadbolt locks with a minimum 1" throw for entry doors of the following units. (706 hc)the rear entry door is missing its deadbolt. install a new deadbolt.
    not activeFeb 2, 2006security requirements sectionrepair the entry alarm (706 hc)the entry alarm on the rear entry door isn't working. make the repairs needed to make it operable.
    not activeFeb 2, 2006security requirements sectionprovide self-closing devices at exterior doors (706 hc)the security gate for the rear entry door near #232 is lacking a door closer. provide and install a closer.
    not activeFeb 2, 2006security requirements sectionprovide self-closing devices for garbage room doors (707 (5) hc)the basement garbage room door is lacking a closer. provide and install a door closer.
    not activeFeb 2, 2006sanitation sectionkeep garbage receptacles covered (1304 hc)the stored garbage cans are not covered. all receptacles must be covered with a tight fitting lid.
    not activeFeb 2, 2006fire sectionpermanently remove combustible storage or provide automatic fire sprinklers. (904, 1001(i) hc)there are garbage cans and mattresses stored outside the garbage room in an unsprinklered area. ove these items to an area open to the sky or have the area sprinklered. if adding sprinkleres provide a copy of the finaled building/plumbing permit.
    not activeFeb 2, 2006fire sectionmake the garbage chutes operable. (1001(b 15)hc)at the time of inspection the garbage chutes were shutdown for repairs. make the necessary repairs and return the garbage chutes to operability.
    not activeFeb 2, 2006interior surfaces sectionpaint ceilings (1001b,1301 hc)paint the damaged surfaces near #117.
    not activeFeb 2, 2006interior surfaces sectionpaint walls (1001b,1301 hc)paint the damaged surfaces near #117.
    not activeFeb 2, 2006other sectionit is the property owner's responsibility to be present or direct his/her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the reinspection.—
    not activeDec 29, 2005security requirements sectionprovide a functioning door knob at exterior doors (706 hc)repair the broken door knob to unit #252. repair should be done within 24 hours.
    not activeDec 29, 2005security requirements sectionprovide ventilation for habitable rooms (504(c), 1001(b)(7),(8) hc)provide an operable ventilation system to the toilet room near #255 and the bath near #202 as well as all other bath and toilet rooms lacking an operable window.
    not activeDec 29, 2005interior surfaces sectionrepair damaged ceilings (1001b,h,o hc)repair the damaged ceiling in the shower room near #248. locate and repair the source of water creating the damage.
    not activeDec 29, 2005interior surfaces sectionpaint ceilings (1001b,1301 hc)paint the repaired ceiling in the shower room near unit #248.
    not activeDec 29, 2005security requirements sectionprovide deadlatch locks with min 1/2" throw at exit doors (706 hc)provide a latch to the entry door of the shower room near unit #248.
    not activeDec 29, 2005interior surfaces sectionrepair damaged walls (1001b,h,o hc)repair the hole in the wall under the sink in the rear community kitchen on the second floor.
    not activeDec 29, 2005plumbing and electrical sectionrepair sink (1001(a4) hc)one sink in the rear community kitchen on the second floor lacks hot water. provide hot water.
    not activeDec 29, 2005plumbing and electrical sectionrepair electric range burners (1001a 13 hc)both range tops in the rear community kitchen of the second floor have inoperable burners. repair/replace the inoperable burners.
    not activeDec 29, 2005other sectionit is the property owner's responsibility to be present or direct his/her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the reinspection.—
    not activeJul 26, 2005building section1)determine cause ,repair and eliminate rusty stains surfacing in tub enclosure and on bathroom wall surfaces in gr#449. 2)remove,contain and properly dispose of flaking bathroom paint. 3)replaster and paint damaged walls and ceiling surfaces in gr#449.1001hc./1301hc.bathroom wall surfaces in gr#449 are peeling paint and plaster in gr#449.
    not activeJul 26, 2005building sectionrepair /replace leaking supply to tub faucet.water is leaking under tub faucet onto bathroom floor.
    not activeJul 26, 2005building sectionrepair/adjust malfunctioning ball cock,to toilet flushing mechanism in gr#449.1001hc.toilet unit does not fill up after two consecutive flushes.
    not activeJul 26, 2005building sectionreplace defective top locking device to entry door gr#449.1001hc./706hc.malfunctioning entry door lock ,constituting lack of security.
    not activeJun 24, 2005building section1)clear stoped up hand wash basin in gr#232.1001hc. 2)extract excessive water from carpeting under,side of sink.1001hc.stoped up sink,water is overflowing soaking guestroom carpeting.
    not activeJun 20, 2005building sectionclean ,shampoo and sanitize stairway carpeting.1306hc.carpeting along rear stairs are in need to be cleaned and shampood.1306hc.
    not activeFeb 7, 2005building sectionclean and sanitize: 1)shower room accross gr #442,#341#243. 2)replace rusty curtain rod in tub room accross gr#341. 3)paint walls and ceiling surfaces in second floor toilet room.1301hc./1001hc.public bathrooms in need of further routine maintanance.
    not activeJun 7, 2006
    security requirements section · repair the guest room entry door (1001 b hc).
    repair the damaged door, frame, and casing to the guest room entry door of #432.
    not activeJun 7, 2006
    other section · inspector comments
    it is the property owner's responsibility to be present or direct his/her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the reinspection.
    not activeJun 1, 2006
    other section · provide heat to each occupied habitable room for 13 hrs between 5:00 a.m. and 11:00 a.m. and between 3:00 p.m. and 10:00 p.m. capable to maintaining a min. room temp. of 68 degrees f. (20 degrees c.). (701c hc)
    there is no heat source in #356. install a radiator.
    not activeJun 1, 2006
    plumbing and electrical section · repair sink (1001f hc)
    repair the leaking sink drain in #356.
    not activeJun 1, 2006
    other section · inspector comments
    it is the property owner's responsibility to be present or direct his/her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the reinspection.
    not activeFeb 17, 2006
    fire section · repair fire proofing with approved materials (hc 1001(m), 809)
    there are holes in the boiler room ceiling. repair the damaged fire resistent surfaces to basement boiler room ceiling. repairs can be made with 5/8" type x drywall, 26 guage sheet metal, cement board, or equivalent. edges must be fire taped or sealed.
    not activeFeb 17, 2006
    fire section · permanently remove combustible storage or provide automatic fire sprinklers. (904, 1001(i) hc)
    there are combustables stored in non-sprinklered areas, including the area outside the boiler room as well as the combustable items stored in the rear yard by the commercial tenant. remove the stored items or install fire sprinklers. if installing sprinklers, provide a copy of the finaled building/plumbing permit for this work.
    not activeFeb 17, 2006
    building section · repair window latches or hardware (1001(b)hc)
    repair the following non-functioning windows: fire escape window near #260- broken latch;
    not activeFeb 17, 2006
    building section · repair window sash frame (1001(h),708 hc)
    repair the following non-functioning windows: front kitchen, second floor-fire escape window plus others won't open; fire escape window near #302, broken sash and sill; fire escape window near third floor front kitchen, won't open or latch; toilet/shower room near #304, sash is falling out; front kitchen, fourth floor fire escape window won't open or latch; toilet room window near #426;
    not activeFeb 17, 2006
    building section · repair window sash cords (1001(h) hc)
    replace the sash cords for the following windows: window in the first floor kitchen.
    not activeFeb 17, 2006
    plumbing and electrical section · repair toilet (1001f hc)
    repair the loose toilet tank in the toilet room near #448.
    not activeFeb 17, 2006
    plumbing and electrical section · repair sink (1001f hc)
    repair the loose faucet and sink in the rear kitchen of the third floor.
    not activeFeb 17, 2006
    fire section · remove egress obstruction at (801,1001(l) hc)
    remove the wire hanging on the fire escape near #332.
    not activeFeb 17, 2006
    smoke detection section · repair central alarm system (908, 909 hc)
    the alarm panel trouble light was on at the time of inspection. have the panel serviced.
    not activeFeb 17, 2006
    plumbing and electrical section · repair the electric range burners (1001a 13 hc)
    repair the range burner elements in the following locations: second floor front kitchen- missing burners;
    not activeFeb 17, 2006
    plumbing and electrical section · repair the range hood fans (1001 a 13 hc)
    repair the range hoods in the following locations: third floor rear kitchen- missing cover, exposed fan blades, - non-functioning fan; fourth floor front kitchen- one non-functioning fan; fourth floor rear kitchen- one non-functiong fan;
    not activeFeb 17, 2006
    plumbing and electrical section · remove cord wiring (1001-e hc)
    remove the exposed electrical wiring on the north wall of the front kitchen on the fourth floor and the rear kitchen of the third floor.
    not activeFeb 17, 2006
    plumbing and electrical section · missing appliance knobs
    replace the missing knobs to the appliances in the front kitchen on the fourth floor.
    not activeFeb 17, 2006
    other section · remove all hasps and eyelets from the exterior of guest room doors ( 706 (a ii) hc)
    remove all hasps and eyelets from the exterior of the guest room doors including the door to #500.
    not activeFeb 17, 2006
    building section · repair window glazing seal (1001(h),(j),& 708 hc)
    repair the broken skylight in the main light well as well as the broken skylight in the secondary light well.
    not activeFeb 17, 2006
    fire section · repair smoke enclosure door closer (807,707 hc)
    repair the door closers for the garbage room near #304 and the toilet room near #323.
    not activeFeb 17, 2006
    plumbing and electrical section · repair lightswitch (1001e hc)
    repair the loose light switch in the shower room near #242.
    not activeFeb 17, 2006
    other section · it is the property owner's responsibility to be present or direct his/her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the reinspection.
    not activeFeb 2, 2006
    security requirements section · replace damged entry door (706 hc).
    the latch side stile of the rear entry door near #232 has been broken, repaired, and broken many times. replace or repair the damaged door.
    not activeFeb 2, 2006
    security requirements section · provide single cylinder deadbolt locks with a minimum 1" throw for entry doors of the following units. (706 hc)
    the rear entry door is missing its deadbolt. install a new deadbolt.
    not activeFeb 2, 2006
    security requirements section · repair the entry alarm (706 hc)
    the entry alarm on the rear entry door isn't working. make the repairs needed to make it operable.
    not activeFeb 2, 2006
    security requirements section · provide self-closing devices at exterior doors (706 hc)
    the security gate for the rear entry door near #232 is lacking a door closer. provide and install a closer.
    not activeFeb 2, 2006
    security requirements section · provide self-closing devices for garbage room doors (707 (5) hc)
    the basement garbage room door is lacking a closer. provide and install a door closer.
    not activeFeb 2, 2006
    sanitation section · keep garbage receptacles covered (1304 hc)
    the stored garbage cans are not covered. all receptacles must be covered with a tight fitting lid.
    not activeFeb 2, 2006
    fire section · permanently remove combustible storage or provide automatic fire sprinklers. (904, 1001(i) hc)
    there are garbage cans and mattresses stored outside the garbage room in an unsprinklered area. ove these items to an area open to the sky or have the area sprinklered. if adding sprinkleres provide a copy of the finaled building/plumbing permit.
    not activeFeb 2, 2006
    fire section · make the garbage chutes operable. (1001(b 15)hc)
    at the time of inspection the garbage chutes were shutdown for repairs. make the necessary repairs and return the garbage chutes to operability.
    not activeFeb 2, 2006
    interior surfaces section · paint ceilings (1001b,1301 hc)
    paint the damaged surfaces near #117.
    not activeFeb 2, 2006
    interior surfaces section · paint walls (1001b,1301 hc)
    paint the damaged surfaces near #117.
    not activeFeb 2, 2006
    other section · it is the property owner's responsibility to be present or direct his/her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the reinspection.
    not activeDec 29, 2005
    security requirements section · provide a functioning door knob at exterior doors (706 hc)
    repair the broken door knob to unit #252. repair should be done within 24 hours.
    not activeDec 29, 2005
    security requirements section · provide ventilation for habitable rooms (504(c), 1001(b)(7),(8) hc)
    provide an operable ventilation system to the toilet room near #255 and the bath near #202 as well as all other bath and toilet rooms lacking an operable window.
    not activeDec 29, 2005
    interior surfaces section · repair damaged ceilings (1001b,h,o hc)
    repair the damaged ceiling in the shower room near #248. locate and repair the source of water creating the damage.
    not activeDec 29, 2005
    interior surfaces section · paint ceilings (1001b,1301 hc)
    paint the repaired ceiling in the shower room near unit #248.
    not activeDec 29, 2005
    security requirements section · provide deadlatch locks with min 1/2" throw at exit doors (706 hc)
    provide a latch to the entry door of the shower room near unit #248.
    not activeDec 29, 2005
    interior surfaces section · repair damaged walls (1001b,h,o hc)
    repair the hole in the wall under the sink in the rear community kitchen on the second floor.
    not activeDec 29, 2005
    plumbing and electrical section · repair sink (1001(a4) hc)
    one sink in the rear community kitchen on the second floor lacks hot water. provide hot water.
    not activeDec 29, 2005
    plumbing and electrical section · repair electric range burners (1001a 13 hc)
    both range tops in the rear community kitchen of the second floor have inoperable burners. repair/replace the inoperable burners.
    not activeDec 29, 2005
    other section · it is the property owner's responsibility to be present or direct his/her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the reinspection.
    not activeJul 26, 2005
    building section · 1)determine cause ,repair and eliminate rusty stains surfacing in tub enclosure and on bathroom wall surfaces in gr#449. 2)remove,contain and properly dispose of flaking bathroom paint. 3)replaster and paint damaged walls and ceiling surfaces in gr#449.1001hc./1301hc.
    bathroom wall surfaces in gr#449 are peeling paint and plaster in gr#449.
    not activeJul 26, 2005
    building section · repair /replace leaking supply to tub faucet.
    water is leaking under tub faucet onto bathroom floor.
    not activeJul 26, 2005
    building section · repair/adjust malfunctioning ball cock,to toilet flushing mechanism in gr#449.1001hc.
    toilet unit does not fill up after two consecutive flushes.
    not activeJul 26, 2005
    building section · replace defective top locking device to entry door gr#449.1001hc./706hc.
    malfunctioning entry door lock ,constituting lack of security.
    not activeJun 24, 2005
    building section · 1)clear stoped up hand wash basin in gr#232.1001hc. 2)extract excessive water from carpeting under,side of sink.1001hc.
    stoped up sink,water is overflowing soaking guestroom carpeting.
    not activeJun 20, 2005
    building section · clean ,shampoo and sanitize stairway carpeting.1306hc.
    carpeting along rear stairs are in need to be cleaned and shampood.1306hc.
    not activeFeb 7, 2005
    building section · clean and sanitize: 1)shower room accross gr #442,#341#243. 2)replace rusty curtain rod in tub room accross gr#341. 3)paint walls and ceiling surfaces in second floor toilet room.1301hc./1001hc.
    public bathrooms in need of further routine maintanance.
    Page 3 of 4