not activeAug 27, 2015
interior surfaces section · prevent migration 3425.4.3 sfbc
once containment barriers and ground protection are in place, establish a restricted work area using 6 millimeter visquene providing full containment to prevent the migration of work debris outside the work area. all windows, doors and vents within 10 feet of work area must be covered and sealed. debris shall be double bagged and duct taped and disposed of in an approved manner. lead debris is a toxic hazard and must be disposed of as such.
not activeAug 27, 2015
interior surfaces section · interior work clean up standards 3425.4.4.2 sfbc
at the completion of work, remove all visible work debris from the regulated area. such efforts shall include but not be limited to hepa vacuum cleaning and wet clean with detergent any exposed interior horizontal surfaces in the regulated areas. at the conclusion of this cleaning, you are required to provide certification from a qualified lead testing laboratory to show that all lead based debris has been removed.
not activeAug 27, 2015
building section · violation of work practices 3426.3
the entire common area of this facility from the basement to the fifth floor is under construction generating work debris. this debris has accumulated and samples were collected from a number of the following locations: picture rails, chair rails, baseboards, mailboxes, hallway carpets, door stiles, door knobs, crash bars, staircase handrails, light fixtures, fire extinguisher boxes, window sills, window sash frames, fire sprinklers, fire sprinkler pipe lines and fire alarm pull handles. this structure is a pre-1979 structure and so this debris is presumed to be lead. provide certification from a qualified lead testing laboratory to show the debris has no lead base.
not activeAug 27, 2015
other section · inspector comments
note: in addition to the regulation established by the city and county of san francisco, work that disturbs lead based paint is also regulated by the epa, the state of california health department, calosha, and the contractors state license board. please be advised to comply with all regulations governing the disturbance of lead based paint. use only approved methods and lead abatement certified contractors for the balance of this work handling lead based paint, dust and debris. it is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection.
not activeOct 17, 2014
DBI code violation
1.) A building you owned on September 15, 2013 was noticed as part of the mandatory Soft Story Retrofit Program. This completed form must be submitted to the Department of Building Inspection By September 15, 2014. You have not returned the form. This building is in violation of the requirements of the San Francisco Building Code regarding earthquake safety. The owner of this building has not complied with the mandatory Soft Story Retrofit Program as required by S.F.B.C. Chapter 34B (SFBC 3405B.6.1). 2.) Monthly Violation Monitoring Fee (SFBC 102A.2.4, Table 1A-K). 3.) Do not remove the posted "Earthquake Warning" Placard.
not activeOct 10, 2014
DBI code violation
1.) A building you owned on September 15, 2013 was noticed as part of the mandatory Soft Story Retrofit Program. This completed form must be submitted to the Department of Building Inspection By September 15, 2014. You have not returned the form. This building is in violation of the requirements of the San Francisco Building Code regarding earthquake safety. The owner of this building has not complied with the mandatory Soft Story Retrofit Program as required by S.F.B.C. Chapter 34B (SFBC 3405B.6.1). 2.) Monthly Violation Monitoring Fee (SFBC 102A.2.4, Table 1A-K). 3.) Do not remove the posted "Earthquake Warning" Placard.
not activeJun 27, 2014
fire section · this notice includes violations for the areas noted.
this notice includes violations of the san francisco housing code. unless otherwise noted all violations were observed on the date of inspection at 825 post street, in the common areas outside.
not activeJun 27, 2014
fire section · replace missing fire escape drop ladders 908, 1001d sfhc
replace the missing drop ladders on the south east and south west corners of the building. the replacement ladders currently in use are an unapproved method of egress that was installed without the benefit of a permit.
not activeJun 27, 2014
fire section · provide building permits 301 sfhc
you are required to obtain a building permit to correct this violation. when applying for a building permit, reference the complaint number from this notice of violation. secure signature and approval from the fire department for these permits. the building inspector must perform final inspection and sign the job card before the housing division can abate this violation.
not activeJun 27, 2014
other section · inspector comments
it is the property owner's responsibility to be present or direct his/ her representative to attend, the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/ or to provide access to all areas cited within this notice. provide all tenants with notification as required by california civil code section 1954 san francisco housing code section 303 (b), if any dwelling, apartment units or guest rooms are to be accessed during the re-inspection.
not activeApr 10, 2014
building section · this notice includes violations for the areas noted.
this notice includes violations of the san francisco housing code. unless otherwise noted all violations were observed on the date of inspection at 825 post street, in the common areas and outside.
not activeApr 10, 2014
fire section · repair the fire escape 908 hc
replace the drop ladders on the south east and south west corners of the building. at the time of inspection they were missing.
not activeApr 10, 2014
fire section · remove egress obstruction (801,1001(l) hc)
remove the window hardware that restricts the fire escape windows from opening on all levels.
not activeApr 10, 2014
other section · inspector comments
it is the property owner's responsibility to be present or direct his/ her representative to attend, the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/ or to provide access to all areas cited within this notice. provide all tenants with notification as required by california civil code section 1954 san francisco housing code section 303 (b), if any dwelling, apartment units or guest rooms are to be accessed during the re-inspection.
not activeOct 12, 2010
building section · this notice includes violations for the areas noted.
all common areas of 825 post street.
not activeOct 12, 2010
fire section · remove dead tree ( 1001 (d))
remove dead tree in courtyard next to adjacent property at 625 leavneworth street.
not activeOct 12, 2010
other section · inspector comments
inspector comments regarding "follow up" reinspection: i have scheduled a reinspection of your building on wednesday, 17-november-2010 at 3:00 pm. reinspection of premise to include all areas referenced above. please contact inspector galvis to confirm appointment at 415-558-6513. it is the property owners responsibility to be present or direct his/her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector. on scheduled reinspection day, provide the inspector with a full access to all common and public areas per attached checklist. your cooperation is appreciated.
not activeFeb 17, 2010
building section · this notice includes violations for the areas noted.
825 post street apartment# 108.
not activeFeb 17, 2010
building section · repair window glazing seal (1001(h),(j),& 708 hc)
in bedroom window at the east side of room left side. also provide weatherstripping.
not activeFeb 17, 2010
interior surfaces section · repair floor covering (1001b,j,o hc)
repair warped floor in hallway in front of bathroom doorway.
not activeFeb 17, 2010
interior surfaces section · paint window frame (1001b,1301 hc)
painting required at window frames in bedroom south side of room. also painting required at door to bedroom. comments regarding possible lead based paint "disturbing lead based paint can be extremely dangerous to dwelling occupants and visitors, particularly to young children, pregnant women, pets, and to people performing work on the premises. for interior or exterior paint removal : always wet the surface, contain and properly dispose of leaded paint. if you are unsure whether the paint is leaded, you should test it prior to performing any work. if the paint is found to contain lead, you should consult with an expert about appropriate procedures. proper containment and 3-day notification is required for exterior jobs of more than 10 square feet. (sec.3604, sfbc) informational packets are available at (415) 558-6088. you can contact the san francisco childhood lead poisoning prevention program at: (415) 554-8930 for free advice. if you cause lead dust to be created, you could be liable for any illness caused by the dust. ordinance #446-97."
not activeFeb 17, 2010
security requirements section · provide minimum 135 degree viewer for entry doors of following units (max mounting ht of 58") (706 hc)
at front door.
not activeFeb 17, 2010
security requirements section · provide manual release mechanism 801 (c) hc
security bars located at windows.
not activeFeb 17, 2010
other section · inspector comments
inspector comments regarding "follow up" reinspection: i have scheduled a reinspection of your building on thursday, 25-february-2010 at 1:30 pm. reinspection of premise to include all areas referenced above. please contact inspector galvis to confirm appointment at 415-558-6513. it is the property owners responsibility to be present or direct his/her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector. on scheduled reinspection day, provide the inspector with a full access to all common and public areas per attached checklist. your cooperation is appreciated.
not activeSep 28, 2009
Heating equipment
No permit to operate the boiler. CMC 1023
not activeApr 7, 2009
building section · this notice includes violations for the areas noted.
all common areas of 825 post street.
not activeApr 7, 2009
interior surfaces section · repair elevator in order to comply with section 703 hc
not activeApr 7, 2009
other section · inspector comments
i have scheduled a reinspection of your building on thursday, 16-april-2009 at 9:00 am. reinspection of premise to include all areas referenced above. please contact inspector galvis to confirm appointment at 415-558-6513. it is the property owner¿s responsibility to be present or direct his/her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector. on scheduled reinspection day, provide the inspector with a full access to all common and public areas per attached checklist. your cooperation is appreciated.
not activeJan 25, 2008
building section · weatherstrip side , bottom of
entry door in order to prevent air infiltration , construction dust and debries to enter unit #216. sec. 1001hc.
not activeJan 25, 2008
building section · keep and maintain common areas
1) hallway, stairways dust free. 2) clean premises after each work day. sec. 1306hc.
not activeOct 5, 2007
building section · repair inoperative elevator unit.
hire the services of a qualified elevator contractor to restore elevator operation. sec. 1002(b).713.h.c.
not activeMay 22, 2007
DBI code violation
Open gas lines in Unit #314 and 315. SFPC Chapter 12.
not activeJan 5, 2005
building section · this notice includes violations for the areas noted.
825 post street #412 and common areas.
not activeJan 5, 2005
fire section · provide manual release at doors (801 hc)
door to leavenworth street. remove any existing double cylinder locking devices that requires a key for exiting and replace with a single cylinder (dead-latch) lock. all means of egress doors, including security gates, must be equipped with an approved manual release mechanism that shall be operable from the inside without the use of a key, tool or any special knowledge or effort
not activeJan 5, 2005
fire section · provide manual release at sleeping room security bars or remove to provide emergency egress to at least one window (706b (7)(i))
the building and housing codes requires that all sleeping rooms (with window security bars) to have a manual release at least to one window for and emergency egress (fire escape). it is the property owner's responsibility to verify that no room with a fixed security bars is being used for a sleeping purposes. test manual releases on window security bars on a regular basis including window hardware. test and verify that all windows and doors leading to the emergency fire escape are operational and unobstructed. advise occupants not to block the path of emergency exits on the inside particularly in sleeping rooms.
not activeJan 5, 2005
fire section · maintain fire escape drop ladders in good working condition (sec 908 hc)
note: property manager, owner or the owner's agent needs to provide a proof of the workability of the fire escape ladders. non-working fire escape drop ladder is a life safety hazard and must be corrected immediately. provide a written report from a qualified service company or contractor stating that all parts and cables have been tested and are functional or contact the housing inspector (within 30 days) to witness lowering the ladder in person. test and verify that all windows or doors leading to emergency fire escape are operational and unobstructed. advise occupants not to block the path of emergency exits on the inside. **reminder**all manufacturers recommend that the fire escape drop ladder be maintained and serviced annually, particularly the cable and all moving parts. lubricate and drop the ladder at least once a year.
not activeJan 5, 2005
plumbing and electrical section · repair lights (1001e hc)
properly install kitchen and bathroom ceiling lights and provide light covers in #412. repair/properly install hallway light near #109.
not activeJan 5, 2005
other section · post current elevator permit (1001(l), 713 hc)
on elevator.
not activeJan 5, 2005
plumbing and electrical section · repair sink (1001f hc)
repair #412's kitchen faucet. resurface #412's kitchen and bathroom sinks.
not activeJan 5, 2005
plumbing and electrical section · other plumbing violations
hot water at #412's bathroom faucet had a dark coloration, please check and repair as necessary.
not activeJan 5, 2005
interior surfaces section · repair floor covering (1001b,j,o hc)
common hallways and stairways -tripping hazard.
not activeJan 5, 2005
interior surfaces section · repair damaged walls (1001b,h,o hc)
#412's closet.
not activeJan 5, 2005
interior surfaces section · disturbing lead based paint can be extremely dangerous to dwelling occupants and visitors, particularly to young children, pregnant women, pets, and to people performing work on the premises. for interior or exterior paint removal : always wet the surface, contain and properly dispose of leaded paint. if you are unsure whether the paint is leaded, you should test it prior to performing any work. if the paint is found to contain lead, you should consult with an expert about appropriate procedures. proper containment and 3-day notification is required for exterior jobs of more than 10 sq.ft. (sec.3604, sfbc) informational packets are available at (415) 558-6088. you can contact the san francisco childhood lead poisoning prevention program at: (415) 554-8930 for free advice. if you cause lead dust to be created, you could be liable for any illness caused by the dust. ordinance #446-97.
not activeJan 5, 2005
interior surfaces section · paint walls (1001b,1301 hc)
after repairs are done.
not activeJan 5, 2005
sanitation section · clean (1306 hc)
#412's walls and ceilings.
not activeJan 5, 2005
smoke detection section · repair smoke detector (908 911 hc)
#412's and where required. replace missing smoke detector at common hallway near fire escape located in the vecinity of #416. live wires were exposed at time of inspection.
not activeJan 5, 2005
interior surfaces section · other interior violations
adjust #412's closet door and entry door to close easily.
not activeJan 5, 2005
building section · repair stairs (1001(b)(13)hc)
repair damaged step on stair to roof.
not activeJan 5, 2005
fire section · provide smoke enclosure door closer (807,707 hc)
at garbage room doors and roof doors (to self-close and latch).
not activeJan 5, 2005
interior surfaces section · repair damaged ceilings (1001b,h,o hc)
repair missing ceiling pannels at laundry room. repair damaged ceilings at leavenworth st "lobby".