17 SLAIGHT STREET

Staten Island · ZIP 10302 · BIN 5129634 · Port Richmond · Last violation Sep 8, 2026 · Last complaint Sep 29, 2026

NeighborhoodPort Richmond
More violations than 86% of nearby buildings
More violations than 86% of buildings and more complaints than 89% of buildings in Port Richmond. Size-normalized against residential buildings in the neighborhood for issues in the last 10 years.
ViolationsComplaints
Activity TrendsLast 5 years
A steady level of activity over time
Last 2 yrs: 46 violations · 54 complaints
'21'26ViolationsComplaints
▼ View all activity over time
Severityⓘopen violations
9 immediately hazardous (Class C) violations still open
Class C violations include lead paint, mold, pest infestations, heat/hot water failure, and structural hazards — the most serious category.
Class Cimmediately hazardous9Class Bhazardous12

What to watch forⓘ

  1. Hazardous violations are open, including fire safety, mold and pests, and heat and hot water.
    Worth checking · AI-assistedⓘ
    Look for blocked doorways, cluttered hallways, or damage to stair railings and fire escape access from windows. Look for droppings, gnaw marks, or live insects in cabinets, under sinks, and along baseboards. Turn on the heat and hot water and feel whether both reach full temperature within a few minutes.
    details ▸

    Deadlines vary by condition: immediate for heat and hot water, 14 days for self-closing doors, 21 days for lead paint, window guards, mold, and mice, cockroaches or rats, and 24 hours for everything else. They run from the date the owner is served, and mark when civil penalties can be sought in Housing Court. They are not a promise the condition is fixed by then. If the owner does not fix it, HPD can send its own contractor and bill them.

    • —Safety & fire — Blocked, unsafe, or inaccessible exits, hallways, stairs, or fire escape routes.
    • —Mold & pests — Rodent, cockroach, bedbug, or other pest infestation and extermination related issues.
Housing Preservation & Development Violations
Total violations since 2009
195
11 per year avg.↑ Up 207% in the last 2 years (46 vs 15 prior 2 yrs)
Open violations
33
Class C (immed. haz.)ⓘ9
Class B (hazardous)ⓘ12
Rent-impairingⓘ2
Housing Preservation & Development Complaints
Total complaints since 2004
206
9 per year avg.↑ Up 184% in the last 2 years (54 vs 19 prior 2 yrs)
Complaint Resolution
No access29%Violation issued32%No violation30%Phone resolved10%Other0%(206)
Urgency breakdown
Last 12 mo.

Top violation categories

5 yrsAll time
Maintenanceⓘ21 violations
Egressⓘ10 violations
Extermination & Rodent Eradicationⓘ8 violations
Water Supplyⓘ8 violations
Heat And Hot Waterⓘ7 violations
Paintingⓘ6 violations
Cleaningⓘ5 violations
Sewers And Drainageⓘ3 violations
Top complaint groupsⓘ
5 yrsAll time
Bldg maintenanceⓘ23 complaints
Water & plumbingⓘ15 complaints
Mold & pestsⓘ13 complaints
Heat / hot waterⓘ12 complaints
Safety & fireⓘ5 complaints
Appliancesⓘ5 complaints
Electricalⓘ3 complaints
See violations →Hide complaints ↑

Complaint log

206 complaints

All categoriesPAINT/PLASTERPLUMBINGHEAT/HOT WATERUNSANITARY CONDITIONDOOR/WINDOWAllOpenClosed
Type
See something wrong? File a complaint with 311
—
Heat / hot water — Lack of heat, hot water, or heating system related issues affecting tenants.

The violation list below shows which conditions are open and when each was cited. If one in your own apartment is still unaddressed, call 311.

  • ABCs of Housing
  • NYC HPD, Penalties and Fees
Open violation ages
▪ < 30 days9% (3)
▪ 30–90 days45% (15)
▪ 3–12 months15% (5)
▪ 1–3 years3% (1)
▪ 3+ years27% (9)
Prior 4 yr.
Immed. Emergency0%2%
Emergency52%53%
Non-Emergency48%45%
(25)
(66)
Status
Apt
Received
Category
EmergencyClosed6BSep 29, 2026UNSANITARY CONDITION · MOLDHPD conducted an inspection of this complaint. The conditions observed by the inspector did not violate the housing laws enforced by HPD. The complaint has been closed.
EmergencyClosed6BSep 29, 2026DOOR/WINDOW · DOORHPD inspected this condition so the complaint has been closed. Violations were issued. The law provides the property owner time to correct the condition(s). Violation descriptions and the dates for the property owner to correct any violations are available at HPDONLINE. If the owner has not corrected the condition by the date provided, you may wish to bring a case in housing court seeking the correction of these conditions.To find out more about how to start a housing court case, visit HPD's webpage on Housing Court (https://www.nyc.gov/site/hpd/services-and-information/housing-court.page).
EmergencyClosed6BSep 29, 2026GENERAL · CABINETHPD inspected this condition so the complaint has been closed. Violations were issued. The law provides the property owner time to correct the condition(s). Violation descriptions and the dates for the property owner to correct any violations are available at HPDONLINE. If the owner has not corrected the condition by the date provided, you may wish to bring a case in housing court seeking the correction of these conditions.To find out more about how to start a housing court case, visit HPD's webpage on Housing Court (https://www.nyc.gov/site/hpd/services-and-information/housing-court.page).
EmergencyClosed12ASep 26, 2026PLUMBING · TOILETAn HPD Inspector was not able to gain access to inspect this complaint sometime within the last 10 days. If the conditions still exist and an inspection is required, please contact HPD with your complaint number to schedule an appointment at
EmergencyClosed6BSep 3, 2026UNSANITARY CONDITION · MOLDHPD conducted an inspection of this complaint. The conditions observed by the inspector did not violate the housing laws enforced by HPD. The complaint has been closed.
Non-emergencyClosed6BSep 3, 2026FLOORING/STAIRS · FLOORHPD conducted an inspection of this complaint. The conditions observed by the inspector did not violate the housing laws enforced by HPD. The complaint has been closed.
Non-emergencyClosed6BSep 3, 2026GENERAL · CABINETHPD inspected this condition so the complaint has been closed. Violations were issued. The law provides the property owner time to correct the condition(s). Violation descriptions and the dates for the property owner to correct any violations are available at HPDONLINE. If the owner has not corrected the condition by the date provided, you may wish to bring a case in housing court seeking the correction of these conditions.To find out more about how to start a housing court case, visit HPD's webpage on Housing Court (https://www.nyc.gov/site/hpd/services-and-information/housing-court.page).
EmergencyClosed6BSep 3, 2026GENERAL · CABINETThe Department of Housing Preservation and Development inspected the following conditions. Violations were previously issued for these conditions. Information about specific violations is available at www.nyc.gov/hpd.
EmergencyClosed2BAug 18, 2026WATER LEAK · HEAVY FLOWHPD inspected this condition so the complaint has been closed. Violations were issued. The law provides the property owner time to correct the condition(s). Violation descriptions and the dates for the property owner to correct any violations are available at HPDONLINE. If the owner has not corrected the condition by the date provided, you may wish to bring a case in housing court seeking the correction of these conditions.To find out more about how to start a housing court case, visit HPD's webpage on Housing Court (https://www.nyc.gov/site/hpd/services-and-information/housing-court.page).
Non-emergencyClosed2BAug 18, 2026PAINT/PLASTER · WALLHPD inspected this condition so the complaint has been closed. Violations were issued. The law provides the property owner time to correct the condition(s). Violation descriptions and the dates for the property owner to correct any violations are available at HPDONLINE. If the owner has not corrected the condition by the date provided, you may wish to bring a case in housing court seeking the correction of these conditions.To find out more about how to start a housing court case, visit HPD's webpage on Housing Court (https://www.nyc.gov/site/hpd/services-and-information/housing-court.page).
Non-emergencyClosed2BAug 18, 2026UNSANITARY CONDITION · PESTSHPD inspected this condition so the complaint has been closed. Violations were issued. The law provides the property owner time to correct the condition(s). Violation descriptions and the dates for the property owner to correct any violations are available at HPDONLINE. If the owner has not corrected the condition by the date provided, you may wish to bring a case in housing court seeking the correction of these conditions.To find out more about how to start a housing court case, visit HPD's webpage on Housing Court (https://www.nyc.gov/site/hpd/services-and-information/housing-court.page).
Non-emergencyClosed2BAug 18, 2026UNSANITARY CONDITION · PESTSHPD inspected this condition so the complaint has been closed. Violations were issued. The law provides the property owner time to correct the condition(s). Violation descriptions and the dates for the property owner to correct any violations are available at HPDONLINE. If the owner has not corrected the condition by the date provided, you may wish to bring a case in housing court seeking the correction of these conditions.To find out more about how to start a housing court case, visit HPD's webpage on Housing Court (https://www.nyc.gov/site/hpd/services-and-information/housing-court.page).
EmergencyClosed11AAug 7, 2026PLUMBING · WATER SUPPLYHPD conducted an inspection of this complaint. The conditions observed by the inspector did not violate the housing laws enforced by HPD. The complaint has been closed.
EmergencyClosed6BAug 4, 2026DOOR/WINDOW · DOORAn HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
EmergencyClosed6BAug 4, 2026GENERAL · CABINETAn HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
Non-emergencyClosed6BAug 4, 2026PLUMBING · BASIN/SINKAn HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
Non-emergencyClosed6BAug 4, 2026PAINT/PLASTER · WALLAn HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
Non-emergencyClosed2BJul 29, 2026PAINT/PLASTER · WALLHPD attempted to conduct an inspection in response to this complaint, but was unable to complete the inspection. Please submit a new service request with 311 if the condition still exists. For more information on the reason why HPD was unable to inspect, contact HPD at the Tenant Information Messaging Service at 212-863-4951.
Non-emergencyClosed2BJul 29, 2026WATER LEAK · SLOW LEAKHPD attempted to conduct an inspection in response to this complaint, but was unable to complete the inspection. Please submit a new service request with 311 if the condition still exists. For more information on the reason why HPD was unable to inspect, contact HPD at the Tenant Information Messaging Service at 212-863-4951.
Non-emergencyClosed2BJul 29, 2026PAINT/PLASTER · CEILINGHPD attempted to conduct an inspection in response to this complaint, but was unable to complete the inspection. Please submit a new service request with 311 if the condition still exists. For more information on the reason why HPD was unable to inspect, contact HPD at the Tenant Information Messaging Service at 212-863-4951.
Non-emergencyClosed2BJul 29, 2026UNSANITARY CONDITION · PESTSHPD attempted to conduct an inspection in response to this complaint, but was unable to complete the inspection. Please submit a new service request with 311 if the condition still exists. For more information on the reason why HPD was unable to inspect, contact HPD at the Tenant Information Messaging Service at 212-863-4951.
Non-emergencyClosed2BJul 29, 2026UNSANITARY CONDITION · PESTSHPD attempted to conduct an inspection in response to this complaint, but was unable to complete the inspection. Please submit a new service request with 311 if the condition still exists. For more information on the reason why HPD was unable to inspect, contact HPD at the Tenant Information Messaging Service at 212-863-4951.
EmergencyClosed2BJun 10, 2026WATER LEAK · HEAVY FLOWHPD inspected this condition so the complaint has been closed. Violations were issued. The law provides the property owner time to correct the condition(s). Violation descriptions and the dates for the property owner to correct any violations are available at HPDONLINE. If the owner has not corrected the condition by the date provided, you may wish to bring a case in housing court seeking the correction of these conditions.To find out more about how to start a housing court case, visit HPD's webpage on Housing Court (https://www.nyc.gov/site/hpd/services-and-information/housing-court.page).
EmergencyClosed6BJan 11, 2026HEAT/HOT WATER · APARTMENT ONLYThe Department of Housing Preservation and Development was not able to gain access to your apartment or others in the building to inspect for a lack of heat or hot water. The complaint has been closed. If the condition still exists, please file a new complaint.
EmergencyClosed10AJan 4, 2026HEAT/HOT WATER · APARTMENT ONLYHPD inspected this condition so the complaint has been closed. Violations were issued. The law provides the property owner time to correct the condition(s). Violation descriptions and the dates for the property owner to correct any violations are available at HPDONLINE. If the owner has not corrected the condition by the date provided, you may wish to bring a case in housing court seeking the correction of these conditions.To find out more about how to start a housing court case, visit HPD's webpage on Housing Court (https://www.nyc.gov/site/hpd/services-and-information/housing-court.page).
EmergencyClosed6BSep 9, 2025HEAT/HOT WATER · ENTIRE BUILDINGThe Department of Housing Preservation and Development was not able to gain access to your apartment or others in the building to inspect for a lack of heat or hot water. The complaint has been closed. If the condition still exists, please file a new complaint.
EmergencyClosed6BSep 4, 2025HEAT/HOT WATER · APARTMENT ONLYHPD inspected this condition so the complaint has been closed. Violations were issued. The law provides the property owner time to correct the condition(s). Violation descriptions and the dates for the property owner to correct any violations are available at HPDONLINE. If the owner has not corrected the condition by the date provided, you may wish to bring a case in housing court seeking the correction of these conditions.To find out more about how to start a housing court case, visit HPD's webpage on Housing Court (https://www.nyc.gov/site/hpd/services-and-information/housing-court.page).
EmergencyClosed6BSep 2, 2025HEAT/HOT WATER · APARTMENT ONLYThe Department of Housing Preservation and Development was not able to gain access to your apartment or others in the building to inspect for a lack of heat or hot water. The complaint has been closed. If the condition still exists, please file a new complaint.
Non-emergencyClosed6BFeb 19, 2025GENERAL · CABINETAn HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
EmergencyClosed6BFeb 19, 2025GENERAL · CABINETAn HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
Non-emergencyClosed6BFeb 19, 2025PLUMBING · TOILETAn HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
Non-emergencyClosed6BFeb 19, 2025GENERAL · VENTILATION SYSTEMAn HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
Non-emergencyClosed6BJan 9, 2025DOOR/WINDOW · DOOR FRAMEAn HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
EmergencyClosed6BJan 9, 2025DOOR/WINDOW · WINDOW FRAMEAn HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
EmergencyClosed6BJan 9, 2025GENERAL · CABINETAn HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
Non-emergencyClosed6BJan 9, 2025PLUMBING · TOILETAn HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
EmergencyClosed6BJan 9, 2025FLOORING/STAIRS · FLOORAn HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
Non-emergencyClosed6BJan 9, 2025PLUMBING · BASIN/SINKAn HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
EmergencyClosed6BJan 9, 2025DOOR/WINDOW · DOORAn HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
Non-emergencyClosed6BJan 9, 2025PAINT/PLASTER · WALLAn HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
EmergencyClosed8ADec 23, 2024HEAT/HOT WATER · ENTIRE BUILDINGHPD inspected this condition so the complaint has been closed. Violations were issued. The law provides the property owner time to correct the condition(s). Violation descriptions and the dates for the property owner to correct any violations are available at HPDONLINE. If the owner has not corrected the condition by the date provided, you may wish to bring a case in housing court seeking the correction of these conditions.To find out more about how to start a housing court case, visit HPD's webpage on Housing Court (https://www.nyc.gov/site/hpd/services-and-information/housing-court.page).
EmergencyClosed6BDec 20, 2024GENERAL · CABINETAn HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
Non-emergencyClosed6BDec 20, 2024PAINT/PLASTER · DOOR/FRAMEAn HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
Non-emergencyClosed6BDec 20, 2024PAINT/PLASTER · WALLAn HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
Non-emergencyClosed6BDec 20, 2024PLUMBING · TOILETAn HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
Non-emergencyClosed2BDec 11, 2024APPLIANCE · REFRIGERATORHPD inspected this condition so the complaint has been closed. Violations were issued. The law provides the property owner time to correct the condition(s). Violation descriptions and the dates for the property owner to correct any violations are available at HPDONLINE. If the owner has not corrected the condition by the date provided, you may wish to bring a case in housing court seeking the correction of these conditions.To find out more about how to start a housing court case, visit HPD's webpage on Housing Court (https://www.nyc.gov/site/hpd/services-and-information/housing-court.page).
EmergencyClosed2BDec 11, 2024PLUMBING · TOILETHPD conducted an inspection of this complaint. The conditions observed by the inspector did not violate the housing laws enforced by HPD. The complaint has been closed.
Non-emergencyClosed2BDec 11, 2024GENERAL · CABINETHPD conducted an inspection of this complaint. The conditions observed by the inspector did not violate the housing laws enforced by HPD. The complaint has been closed.
EmergencyClosed2BDec 11, 2024PLUMBING · BATHTUB/SHOWERHPD conducted an inspection of this complaint. The conditions observed by the inspector did not violate the housing laws enforced by HPD. The complaint has been closed.
Non-emergencyClosed2BDec 11, 2024FLOORING/STAIRS · FLOORHPD inspected this condition so the complaint has been closed. Violations were issued. The law provides the property owner time to correct the condition(s). Violation descriptions and the dates for the property owner to correct any violations are available at HPDONLINE. If the owner has not corrected the condition by the date provided, you may wish to bring a case in housing court seeking the correction of these conditions.To find out more about how to start a housing court case, visit HPD's webpage on Housing Court (https://www.nyc.gov/site/hpd/services-and-information/housing-court.page).
EmergencyClosed
Sep 29, 2026Apt 6B
UNSANITARY CONDITION · MOLD
HPD conducted an inspection of this complaint. The conditions observed by the inspector did not violate the housing laws enforced by HPD. The complaint has been closed.
EmergencyClosed
Sep 29, 2026Apt 6B
DOOR/WINDOW · DOOR
HPD inspected this condition so the complaint has been closed. Violations were issued. The law provides the property owner time to correct the condition(s). Violation descriptions and the dates for the property owner to correct any violations are available at HPDONLINE. If the owner has not corrected the condition by the date provided, you may wish to bring a case in housing court seeking the correction of these conditions.To find out more about how to start a housing court case, visit HPD's webpage on Housing Court (https://www.nyc.gov/site/hpd/services-and-information/housing-court.page).
EmergencyClosed
Sep 29, 2026Apt 6B
GENERAL · CABINET
HPD inspected this condition so the complaint has been closed. Violations were issued. The law provides the property owner time to correct the condition(s). Violation descriptions and the dates for the property owner to correct any violations are available at HPDONLINE. If the owner has not corrected the condition by the date provided, you may wish to bring a case in housing court seeking the correction of these conditions.To find out more about how to start a housing court case, visit HPD's webpage on Housing Court (https://www.nyc.gov/site/hpd/services-and-information/housing-court.page).
EmergencyClosed
Sep 26, 2026Apt 12A
PLUMBING · TOILET
An HPD Inspector was not able to gain access to inspect this complaint sometime within the last 10 days. If the conditions still exist and an inspection is required, please contact HPD with your complaint number to schedule an appointment at
EmergencyClosed
Sep 3, 2026Apt 6B
UNSANITARY CONDITION · MOLD
HPD conducted an inspection of this complaint. The conditions observed by the inspector did not violate the housing laws enforced by HPD. The complaint has been closed.
Non-emergencyClosed
Sep 3, 2026Apt 6B
FLOORING/STAIRS · FLOOR
HPD conducted an inspection of this complaint. The conditions observed by the inspector did not violate the housing laws enforced by HPD. The complaint has been closed.
Non-emergencyClosed
Sep 3, 2026Apt 6B
GENERAL · CABINET
HPD inspected this condition so the complaint has been closed. Violations were issued. The law provides the property owner time to correct the condition(s). Violation descriptions and the dates for the property owner to correct any violations are available at HPDONLINE. If the owner has not corrected the condition by the date provided, you may wish to bring a case in housing court seeking the correction of these conditions.To find out more about how to start a housing court case, visit HPD's webpage on Housing Court (https://www.nyc.gov/site/hpd/services-and-information/housing-court.page).
EmergencyClosed
Sep 3, 2026Apt 6B
GENERAL · CABINET
The Department of Housing Preservation and Development inspected the following conditions. Violations were previously issued for these conditions. Information about specific violations is available at www.nyc.gov/hpd.
EmergencyClosed
Aug 18, 2026Apt 2B
WATER LEAK · HEAVY FLOW
HPD inspected this condition so the complaint has been closed. Violations were issued. The law provides the property owner time to correct the condition(s). Violation descriptions and the dates for the property owner to correct any violations are available at HPDONLINE. If the owner has not corrected the condition by the date provided, you may wish to bring a case in housing court seeking the correction of these conditions.To find out more about how to start a housing court case, visit HPD's webpage on Housing Court (https://www.nyc.gov/site/hpd/services-and-information/housing-court.page).
Non-emergencyClosed
Aug 18, 2026Apt 2B
PAINT/PLASTER · WALL
HPD inspected this condition so the complaint has been closed. Violations were issued. The law provides the property owner time to correct the condition(s). Violation descriptions and the dates for the property owner to correct any violations are available at HPDONLINE. If the owner has not corrected the condition by the date provided, you may wish to bring a case in housing court seeking the correction of these conditions.To find out more about how to start a housing court case, visit HPD's webpage on Housing Court (https://www.nyc.gov/site/hpd/services-and-information/housing-court.page).
Non-emergencyClosed
Aug 18, 2026Apt 2B
UNSANITARY CONDITION · PESTS
HPD inspected this condition so the complaint has been closed. Violations were issued. The law provides the property owner time to correct the condition(s). Violation descriptions and the dates for the property owner to correct any violations are available at HPDONLINE. If the owner has not corrected the condition by the date provided, you may wish to bring a case in housing court seeking the correction of these conditions.To find out more about how to start a housing court case, visit HPD's webpage on Housing Court (https://www.nyc.gov/site/hpd/services-and-information/housing-court.page).
Non-emergencyClosed
Aug 18, 2026Apt 2B
UNSANITARY CONDITION · PESTS
HPD inspected this condition so the complaint has been closed. Violations were issued. The law provides the property owner time to correct the condition(s). Violation descriptions and the dates for the property owner to correct any violations are available at HPDONLINE. If the owner has not corrected the condition by the date provided, you may wish to bring a case in housing court seeking the correction of these conditions.To find out more about how to start a housing court case, visit HPD's webpage on Housing Court (https://www.nyc.gov/site/hpd/services-and-information/housing-court.page).
EmergencyClosed
Aug 7, 2026Apt 11A
PLUMBING · WATER SUPPLY
HPD conducted an inspection of this complaint. The conditions observed by the inspector did not violate the housing laws enforced by HPD. The complaint has been closed.
EmergencyClosed
Aug 4, 2026Apt 6B
DOOR/WINDOW · DOOR
An HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
EmergencyClosed
Aug 4, 2026Apt 6B
GENERAL · CABINET
An HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
Non-emergencyClosed
Aug 4, 2026Apt 6B
PLUMBING · BASIN/SINK
An HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
Non-emergencyClosed
Aug 4, 2026Apt 6B
PAINT/PLASTER · WALL
An HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
Non-emergencyClosed
Jul 29, 2026Apt 2B
PAINT/PLASTER · WALL
HPD attempted to conduct an inspection in response to this complaint, but was unable to complete the inspection. Please submit a new service request with 311 if the condition still exists. For more information on the reason why HPD was unable to inspect, contact HPD at the Tenant Information Messaging Service at 212-863-4951.
Non-emergencyClosed
Jul 29, 2026Apt 2B
WATER LEAK · SLOW LEAK
HPD attempted to conduct an inspection in response to this complaint, but was unable to complete the inspection. Please submit a new service request with 311 if the condition still exists. For more information on the reason why HPD was unable to inspect, contact HPD at the Tenant Information Messaging Service at 212-863-4951.
Non-emergencyClosed
Jul 29, 2026Apt 2B
PAINT/PLASTER · CEILING
HPD attempted to conduct an inspection in response to this complaint, but was unable to complete the inspection. Please submit a new service request with 311 if the condition still exists. For more information on the reason why HPD was unable to inspect, contact HPD at the Tenant Information Messaging Service at 212-863-4951.
Non-emergencyClosed
Jul 29, 2026Apt 2B
UNSANITARY CONDITION · PESTS
HPD attempted to conduct an inspection in response to this complaint, but was unable to complete the inspection. Please submit a new service request with 311 if the condition still exists. For more information on the reason why HPD was unable to inspect, contact HPD at the Tenant Information Messaging Service at 212-863-4951.
Non-emergencyClosed
Jul 29, 2026Apt 2B
UNSANITARY CONDITION · PESTS
HPD attempted to conduct an inspection in response to this complaint, but was unable to complete the inspection. Please submit a new service request with 311 if the condition still exists. For more information on the reason why HPD was unable to inspect, contact HPD at the Tenant Information Messaging Service at 212-863-4951.
EmergencyClosed
Jun 10, 2026Apt 2B
WATER LEAK · HEAVY FLOW
HPD inspected this condition so the complaint has been closed. Violations were issued. The law provides the property owner time to correct the condition(s). Violation descriptions and the dates for the property owner to correct any violations are available at HPDONLINE. If the owner has not corrected the condition by the date provided, you may wish to bring a case in housing court seeking the correction of these conditions.To find out more about how to start a housing court case, visit HPD's webpage on Housing Court (https://www.nyc.gov/site/hpd/services-and-information/housing-court.page).
EmergencyClosed
Jan 11, 2026Apt 6B
HEAT/HOT WATER · APARTMENT ONLY
The Department of Housing Preservation and Development was not able to gain access to your apartment or others in the building to inspect for a lack of heat or hot water. The complaint has been closed. If the condition still exists, please file a new complaint.
EmergencyClosed
Jan 4, 2026Apt 10A
HEAT/HOT WATER · APARTMENT ONLY
HPD inspected this condition so the complaint has been closed. Violations were issued. The law provides the property owner time to correct the condition(s). Violation descriptions and the dates for the property owner to correct any violations are available at HPDONLINE. If the owner has not corrected the condition by the date provided, you may wish to bring a case in housing court seeking the correction of these conditions.To find out more about how to start a housing court case, visit HPD's webpage on Housing Court (https://www.nyc.gov/site/hpd/services-and-information/housing-court.page).
EmergencyClosed
Sep 9, 2025Apt 6B
HEAT/HOT WATER · ENTIRE BUILDING
The Department of Housing Preservation and Development was not able to gain access to your apartment or others in the building to inspect for a lack of heat or hot water. The complaint has been closed. If the condition still exists, please file a new complaint.
EmergencyClosed
Sep 4, 2025Apt 6B
HEAT/HOT WATER · APARTMENT ONLY
HPD inspected this condition so the complaint has been closed. Violations were issued. The law provides the property owner time to correct the condition(s). Violation descriptions and the dates for the property owner to correct any violations are available at HPDONLINE. If the owner has not corrected the condition by the date provided, you may wish to bring a case in housing court seeking the correction of these conditions.To find out more about how to start a housing court case, visit HPD's webpage on Housing Court (https://www.nyc.gov/site/hpd/services-and-information/housing-court.page).
EmergencyClosed
Sep 2, 2025Apt 6B
HEAT/HOT WATER · APARTMENT ONLY
The Department of Housing Preservation and Development was not able to gain access to your apartment or others in the building to inspect for a lack of heat or hot water. The complaint has been closed. If the condition still exists, please file a new complaint.
Non-emergencyClosed
Feb 19, 2025Apt 6B
GENERAL · CABINET
An HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
EmergencyClosed
Feb 19, 2025Apt 6B
GENERAL · CABINET
An HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
Non-emergencyClosed
Feb 19, 2025Apt 6B
PLUMBING · TOILET
An HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
Non-emergencyClosed
Feb 19, 2025Apt 6B
GENERAL · VENTILATION SYSTEM
An HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
Non-emergencyClosed
Jan 9, 2025Apt 6B
DOOR/WINDOW · DOOR FRAME
An HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
EmergencyClosed
Jan 9, 2025Apt 6B
DOOR/WINDOW · WINDOW FRAME
An HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
EmergencyClosed
Jan 9, 2025Apt 6B
GENERAL · CABINET
An HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
Non-emergencyClosed
Jan 9, 2025Apt 6B
PLUMBING · TOILET
An HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
EmergencyClosed
Jan 9, 2025Apt 6B
FLOORING/STAIRS · FLOOR
An HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
Non-emergencyClosed
Jan 9, 2025Apt 6B
PLUMBING · BASIN/SINK
An HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
EmergencyClosed
Jan 9, 2025Apt 6B
DOOR/WINDOW · DOOR
An HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
Non-emergencyClosed
Jan 9, 2025Apt 6B
PAINT/PLASTER · WALL
An HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
EmergencyClosed
Dec 23, 2024Apt 8A
HEAT/HOT WATER · ENTIRE BUILDING
HPD inspected this condition so the complaint has been closed. Violations were issued. The law provides the property owner time to correct the condition(s). Violation descriptions and the dates for the property owner to correct any violations are available at HPDONLINE. If the owner has not corrected the condition by the date provided, you may wish to bring a case in housing court seeking the correction of these conditions.To find out more about how to start a housing court case, visit HPD's webpage on Housing Court (https://www.nyc.gov/site/hpd/services-and-information/housing-court.page).
EmergencyClosed
Dec 20, 2024Apt 6B
GENERAL · CABINET
An HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
Non-emergencyClosed
Dec 20, 2024Apt 6B
PAINT/PLASTER · DOOR/FRAME
An HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
Non-emergencyClosed
Dec 20, 2024Apt 6B
PAINT/PLASTER · WALL
An HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
Non-emergencyClosed
Dec 20, 2024Apt 6B
PLUMBING · TOILET
An HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
Non-emergencyClosed
Dec 11, 2024Apt 2B
APPLIANCE · REFRIGERATOR
HPD inspected this condition so the complaint has been closed. Violations were issued. The law provides the property owner time to correct the condition(s). Violation descriptions and the dates for the property owner to correct any violations are available at HPDONLINE. If the owner has not corrected the condition by the date provided, you may wish to bring a case in housing court seeking the correction of these conditions.To find out more about how to start a housing court case, visit HPD's webpage on Housing Court (https://www.nyc.gov/site/hpd/services-and-information/housing-court.page).
EmergencyClosed
Dec 11, 2024Apt 2B
PLUMBING · TOILET
HPD conducted an inspection of this complaint. The conditions observed by the inspector did not violate the housing laws enforced by HPD. The complaint has been closed.
Non-emergencyClosed
Dec 11, 2024Apt 2B
GENERAL · CABINET
HPD conducted an inspection of this complaint. The conditions observed by the inspector did not violate the housing laws enforced by HPD. The complaint has been closed.
EmergencyClosed
Dec 11, 2024Apt 2B
PLUMBING · BATHTUB/SHOWER
HPD conducted an inspection of this complaint. The conditions observed by the inspector did not violate the housing laws enforced by HPD. The complaint has been closed.
Non-emergencyClosed
Dec 11, 2024Apt 2B
FLOORING/STAIRS · FLOOR
HPD inspected this condition so the complaint has been closed. Violations were issued. The law provides the property owner time to correct the condition(s). Violation descriptions and the dates for the property owner to correct any violations are available at HPDONLINE. If the owner has not corrected the condition by the date provided, you may wish to bring a case in housing court seeking the correction of these conditions.To find out more about how to start a housing court case, visit HPD's webpage on Housing Court (https://www.nyc.gov/site/hpd/services-and-information/housing-court.page).