stoop
MAP
LeaderboardAbout
Building SafetyHousing Conditions

55 HOLLAND AVENUE

Staten Island · ZIP 10303 · BIN 5112687 · Mariner's Harbor-Arlington-Graniteville · Last violation Aug 11, 2026 · Last complaint Jun 19, 2026

NeighborhoodMariner's Harbor-Arlington-Graniteville
More violations than 97% of nearby buildings
More violations than 97% of buildings and more complaints than 94% of buildings in Mariner's Harbor-Arlington-Graniteville. Size-normalized against residential buildings in the neighborhood for issues in the last 10 years.
ViolationsComplaints
Activity TrendsLast 5 years
A steady level of activity over time
Last 2 yrs: 464 violations · 186 complaints
'21'26ViolationsComplaints
▼ View all activity over time
Severityⓘopen violations
39 immediately hazardous (Class C) violations still open
Class C violations include lead paint, mold, pest infestations, heat/hot water failure, and structural hazards — the most serious category.
Class Cimmediately hazardous39Class Bhazardous20

What to watch forⓘ

  1. Hazardous violations are open, including mold and pests, and fire safety.
    Worth checking · AI-assistedⓘ
    Look for droppings, live insects, or damage to walls, cabinets, and baseboards in the kitchen, bathroom, and under sinks. Check that apartment entry doors, stairwell doors, and fire escape access are all unlocked and open freely without obstruction.
    details ▸

    Deadlines vary by condition: immediate for heat and hot water, 14 days for self-closing doors, 21 days for lead paint, window guards, mold, and mice, cockroaches or rats, and 24 hours for everything else. They run from the date the owner is served, and mark when civil penalties can be sought in Housing Court. They are not a promise the condition is fixed by then. If the owner does not fix it, HPD can send its own contractor and bill them.

    • —Mold & pests — Rodent, cockroach, bedbug, or other pest infestation and extermination related issues.
    • —Safety & fire — Blocked, unsafe, or inaccessible exits, hallways, stairs, or fire escape routes.

    The violation list below shows which conditions are open and when each was cited. If one in your own apartment is still unaddressed, call 311.

Housing Preservation & Development Violations
Total violations since 1988
2,259
58 per year avg.↑ Up 12% in the last 2 years (464 vs 415 prior 2 yrs)
Open violations
68
Class C (immed. haz.)ⓘ39
Class B (hazardous)ⓘ20
Rent-impairingⓘ1
Housing Preservation & Development Complaints
Total complaints since 2003
2,029
85 per year avg.→ Stable in the last 2 years
Complaint Resolution
No access13%Violation issued25%No violation36%Phone resolved26%Other0%(2,029)
Urgency breakdown
Last 12 mo.

Top violation categories

5 yrsAll time
Maintenanceⓘ367 violations
Egressⓘ150 violations
Water Supplyⓘ85 violations
Paintingⓘ79 violations
Extermination & Rodent Eradicationⓘ60 violations
Carbon Monoxide Detecting Devicesⓘ59 violations
Smoke Detecting Devicesⓘ55 violations
Cleaningⓘ52 violations
Top complaint groupsⓘ
5 yrsAll time
Heat / hot waterⓘ151 complaints
Water & plumbingⓘ99 complaints
Bldg maintenanceⓘ85 complaints
Mold & pestsⓘ55 complaints
Appliancesⓘ20 complaints
Electricalⓘ15 complaints
Safety & fireⓘ6 complaints
Hide violations ↑See complaints →

Violation log

2,191 violations · Close

All classesClass AClass BClass CClass IAllOpenClosed
ClassStatusApt
See something wrong? File a complaint with 311
  • NYC HPD, ABCs of Housing 2024 (Tenants' Guide) — violation classes
  • NYC HPD, Penalties and Fees — correction deadlines
  • Heat or hot water problems reported in the last five years.
    Worth checking · AI-assistedⓘ
    Turn on hot water at the kitchen sink and bathroom sink and feel the water temperature after running for one minute.
    details ▸

    Heat is required October 1 through May 31: at least 68°F from 6am to 10pm when it is below 55°F outside, and 62°F overnight whatever the temperature outside. Hot water must be at least 120°F, 24 hours a day, all year.

    If your apartment is colder than that, file a complaint with 311 and keep the service request number so you can track it. Never use a gas oven or range for heat, which can produce dangerous levels of carbon monoxide.

    • NYC HPD, ABCs of Housing 2024 (Tenants' Guide)
  • Detector violations on record.
    Worth checking · AI-assistedⓘ
    Locate smoke detectors on the ceiling near bedrooms and in hallways, and ask the broker whether carbon monoxide detectors are present in the unit.
    details ▸

    Responsibility is split: the owner provides, installs, and replaces the detectors, while the tenant tests them monthly and replaces the batteries. An open violation means the owner has not yet certified to HPD that the condition was fixed, so a device may still be missing or dead at move-in. A tenant reimburses the owner for a newly installed device, $25 for a smoke or carbon monoxide detector and $50 for a combined unit, and is responsible for replacing one that goes missing or is damaged during the tenancy.

    On a viewing, look for a smoke alarm within fifteen feet of the door of each room used for sleeping, on the ceiling or just below it on the wall, and a carbon monoxide alarm at any height, including one plugged into a hallway outlet. Press the test button, and check that none have been painted over. A chirping alarm usually means a low battery, which is the tenant's to replace, but detectors also sound a separate end-of-life alarm when the device itself has to be replaced by the owner.

    • NYC HPD, ABCs of Housing 2024 (Tenants' Guide) — the requirement
    • NYC HPD, Smoke, Carbon Monoxide, and Natural Gas Detectors — responsibilities, placement, and reimbursement
  • Open violation ages
    ▪ < 30 days9% (6)
    ▪ 30–90 days26% (18)
    ▪ 3–12 months53% (36)
    ▪ 1–3 years7% (5)
    ▪ 3+ years4% (3)
    Prior 4 yr.
    Immed. Emergency9%2%
    Emergency74%66%
    Non-Emergency17%32%
    (90)
    (392)
    Issued
    Description
    Class CClosed3HJun 10, 2024LEAD-BASED PAINT HAZARD- POSITIVE · LEAD-BASED PAINT§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st RADIATOR FROM NORTH AT EAST WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 3H, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH
    Class AClosed3HJun 10, 2024PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE BATHROOM , THE 1st ROOM FROM NORTH AT EAST, THE KITCHEN LOCATED AT APT 3H, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH
    Class CClosedRENT IMPAIRINGLOJun 6, 2024REMOVE OBSTUCTION FROM WATER CLOSET · SEWERS AND DRAINAGE§ 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS FROM WATER CLOSET IN THE 1st BATHROOM FROM EAST LOCATED AT APT LO, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class AClosed5BJun 6, 2024REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 5B, 5th STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed5EJun 6, 2024REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD CABINET DOOR AT NORTH WALL IN THE KITCHEN LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosed5EJun 6, 2024REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE RUBBER GASKET AT REFRIGERATOR DOOR IN THE KITCHEN LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosed5DJun 6, 2024REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 5D, 5th STORY, 5th APARTMENT FROM EAST AT SOUTH
    Class BClosed3MJun 6, 2024REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3M, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosed3LJun 6, 2024REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND SOUTH WALL IN THE BATHROOM LOCATED AT APT 3L, 3rd STORY, 5th APARTMENT FROM WEST AT NORTH
    Class BClosed3LJun 6, 2024REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 3L, 3rd STORY, 5th APARTMENT FROM WEST AT NORTH
    Class BClosed3MJun 6, 2024TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... (APPROX. 12 SQ. FEET) AT CEILING IN THE BATHROOM LOCATED AT APT 3M, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosed3MJun 6, 2024REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3M, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosed4BJun 6, 2024REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 4B, 4th STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed3KJun 6, 2024REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOCK AND ASSEMBLY AT DOOR IN THE ENTRANCE LOCATED AT APT 3K, 3rd STORY, 4th APARTMENT FROM WEST AT NORTH
    Class BClosed3MJun 6, 2024REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING IN THE KITCHEN LOCATED AT APT 3M, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosed3LJun 6, 2024REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND EAST WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 3L, 3rd STORY, 5th APARTMENT FROM WEST AT NORTH
    Class BClosed3LJun 6, 2024REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 3L, 3rd STORY, 5th APARTMENT FROM WEST AT NORTH
    Class AClosed3LJun 6, 2024REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE CLOSET DOOR AT SOUTH WALL IN THE 3rd ROOM FROM EAST AT NORTH LOCATED AT APT 3L, 3rd STORY, 5th APARTMENT FROM WEST AT NORTH
    Class BClosed3LJun 6, 2024REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE REFRIGRATOR DOOR GASKET IN THE KITCHEN LOCATED AT APT 3L, 3rd STORY, 5th APARTMENT FROM WEST AT NORTH
    Class BClosedRENT IMPAIRINGLOJun 6, 2024REMOVE OBSTRUCTIONS · SEWERS AND DRAINAGE§ 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTELINE AT BATHTUB IN THE 1st BATHROOM FROM EAST LOCATED AT APT LO, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosed4AJun 6, 2024REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND NORTH WALL IN THE BATHROOM LOCATED AT APT 4A, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH
    Class AClosed3HJun 6, 2024REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE CLOSET DOOR AT WEST WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 3H, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH
    Class AClosed3MJun 6, 2024PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS, CEILING AND TRIMS IN THE ENTIRE APARTMENT LOCATED AT APT 3M, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosed4AJun 6, 2024REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 4A, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH
    Class BClosed9HJun 6, 2024REFIT DOORS ETC. · EGRESS§ 27-2005 HMC: REFIT DOOR LEADING TO BALCONY IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 9H, 9th STORY, 2nd APARTMENT FROM WEST AT NORTH
    Class BClosed5AJun 6, 2024REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE INTERCOM PANEL AT EAST WALL IN THE PRIVATE HALLWAY LOCATED AT APT 5A, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH
    Class AClosed4EJun 6, 2024REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 4E, 4th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BClosed5BJun 6, 2024REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 5B, 5th STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed5EJun 6, 2024REFIT DOORS ETC. · EGRESS§ 27-2005 HMC: REFIT DOOR IN THE ENTRANCE LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class AClosed5DJun 6, 2024REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 5D, 5th STORY, 5th APARTMENT FROM EAST AT SOUTH
    Class AClosed4EJun 6, 2024REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 4E, 4th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BClosed5BJun 6, 2024REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 5B, 5th STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed4BJun 6, 2024REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND SOUTH WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 4B, 4th STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class AClosed9HJun 6, 2024REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ENTRANCE DOOR IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 9H, 9th STORY, 2nd APARTMENT FROM WEST AT NORTH
    Class BClosedRENT IMPAIRING3KJun 6, 2024REMOVE ILLEGAL FASTENING · EGRESS§ 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING SLIDE BOLT INSTALLED AT INTERIOR SIDE OF DOOR, CAPABLE OF BEING PAD-LOCKED IN THE ENTRANCE LOCATED AT APT 3K, 3rd STORY, 4th APARTMENT FROM WEST AT NORTH
    Class BClosed10JJun 5, 2024REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND EAST WALL IN THE BATHROOM LOCATED AT APT 10J, 10th STORY, 3rd APARTMENT FROM WEST AT NORTH
    Class BClosed12HJun 5, 2024REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING, AND THE NORTH AND WEST WALLS IN THE 1st ROOM FROM NORTH LOCATED AT APT 12H, 12th STORY, 2nd APARTMENT FROM EAST AT SOUTH
    Class BClosed12EJun 5, 2024REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND SOUTH WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 12E, 12th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosedRENT IMPAIRING10HJun 5, 2024REMOVE OBSTRUCTIONS · SEWERS AND DRAINAGE§ 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTELINE AT BATHTUB IN THE BATHROOM LOCATED AT APT 10H, 10th STORY, 2nd APARTMENT FROM WEST AT NORTH
    Class BClosed12EJun 5, 2024REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 12E, 12th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosed10JJun 5, 2024REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE EAST WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 10J, 10th STORY, 3rd APARTMENT FROM WEST AT NORTH
    Class BClosed12HJun 5, 2024REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 12H, 12th STORY, 2nd APARTMENT FROM EAST AT SOUTH
    Class BClosed12BJun 5, 2024REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 12B, 12th STORY, 3rd APARTMENT FROM WEST AT NORTH
    Class AClosed7LJun 4, 2024REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PLASTIC BASEBOARD MOULDING AT NORTH WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 7L, 7th STORY, 5th APARTMENT FROM WEST AT NORTH
    Class AClosed8HJun 4, 2024REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE EAST WALL IN THE FOYER LOCATED AT APT 8H, 8th STORY, 2nd APARTMENT FROM WEST AT NORTH
    Class AClosed7EJun 4, 2024REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 7E, 7th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class AClosed7EJun 4, 2024REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 7E, 7th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class AClosed8HJun 4, 2024REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING AROUND BATHTUB IN THE BATHROOM LOCATED AT APT 8H, 8th STORY, 2nd APARTMENT FROM WEST AT NORTH
    Class CClosed7EJun 4, 2024MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ''HINGES'' IN THE ENTRANCE LOCATED AT APT 7E, 7th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BClosedRENT IMPAIRING6LJun 4, 2024REMOVE OBSTRUCTIONS · SEWERS AND DRAINAGE§ 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN DRAIN PIPE AT BATHTUB IN THE BATHROOM LOCATED AT APT 6L, 6th STORY, 5th APARTMENT FROM WEST AT NORTH
    Class CClosed
    Jun 10, 2024Apt 3H
    LEAD-BASED PAINT HAZARD- POSITIVE · LEAD-BASED PAINT
    § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st RADIATOR FROM NORTH AT EAST WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 3H, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH
    Class AClosed
    Jun 10, 2024Apt 3H
    PAINT · PAINTING
    § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE BATHROOM , THE 1st ROOM FROM NORTH AT EAST, THE KITCHEN LOCATED AT APT 3H, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH
    Class CClosedRENT IMPAIRING
    Jun 6, 2024Apt LO
    REMOVE OBSTUCTION FROM WATER CLOSET · SEWERS AND DRAINAGE
    § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS FROM WATER CLOSET IN THE 1st BATHROOM FROM EAST LOCATED AT APT LO, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class AClosed
    Jun 6, 2024Apt 5B
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 5B, 5th STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Jun 6, 2024Apt 5E
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD CABINET DOOR AT NORTH WALL IN THE KITCHEN LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Jun 6, 2024Apt 5E
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE RUBBER GASKET AT REFRIGERATOR DOOR IN THE KITCHEN LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Jun 6, 2024Apt 5D
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 5D, 5th STORY, 5th APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Jun 6, 2024Apt 3M
    REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
    § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3M, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Jun 6, 2024Apt 3L
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND SOUTH WALL IN THE BATHROOM LOCATED AT APT 3L, 3rd STORY, 5th APARTMENT FROM WEST AT NORTH
    Class BClosed
    Jun 6, 2024Apt 3L
    REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
    § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 3L, 3rd STORY, 5th APARTMENT FROM WEST AT NORTH
    Class BClosed
    Jun 6, 2024Apt 3M
    TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
    § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... (APPROX. 12 SQ. FEET) AT CEILING IN THE BATHROOM LOCATED AT APT 3M, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Jun 6, 2024Apt 3M
    REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
    § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3M, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Jun 6, 2024Apt 4B
    REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
    § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 4B, 4th STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Jun 6, 2024Apt 3K
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOCK AND ASSEMBLY AT DOOR IN THE ENTRANCE LOCATED AT APT 3K, 3rd STORY, 4th APARTMENT FROM WEST AT NORTH
    Class BClosed
    Jun 6, 2024Apt 3M
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING IN THE KITCHEN LOCATED AT APT 3M, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Jun 6, 2024Apt 3L
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND EAST WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 3L, 3rd STORY, 5th APARTMENT FROM WEST AT NORTH
    Class BClosed
    Jun 6, 2024Apt 3L
    REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
    § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 3L, 3rd STORY, 5th APARTMENT FROM WEST AT NORTH
    Class AClosed
    Jun 6, 2024Apt 3L
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE CLOSET DOOR AT SOUTH WALL IN THE 3rd ROOM FROM EAST AT NORTH LOCATED AT APT 3L, 3rd STORY, 5th APARTMENT FROM WEST AT NORTH
    Class BClosed
    Jun 6, 2024Apt 3L
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE REFRIGRATOR DOOR GASKET IN THE KITCHEN LOCATED AT APT 3L, 3rd STORY, 5th APARTMENT FROM WEST AT NORTH
    Class BClosedRENT IMPAIRING
    Jun 6, 2024Apt LO
    REMOVE OBSTRUCTIONS · SEWERS AND DRAINAGE
    § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTELINE AT BATHTUB IN THE 1st BATHROOM FROM EAST LOCATED AT APT LO, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Jun 6, 2024Apt 4A
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND NORTH WALL IN THE BATHROOM LOCATED AT APT 4A, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH
    Class AClosed
    Jun 6, 2024Apt 3H
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE CLOSET DOOR AT WEST WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 3H, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH
    Class AClosed
    Jun 6, 2024Apt 3M
    PAINT · PAINTING
    § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS, CEILING AND TRIMS IN THE ENTIRE APARTMENT LOCATED AT APT 3M, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Jun 6, 2024Apt 4A
    REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
    § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 4A, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Jun 6, 2024Apt 9H
    REFIT DOORS ETC. · EGRESS
    § 27-2005 HMC: REFIT DOOR LEADING TO BALCONY IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 9H, 9th STORY, 2nd APARTMENT FROM WEST AT NORTH
    Class BClosed
    Jun 6, 2024Apt 5A
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE INTERCOM PANEL AT EAST WALL IN THE PRIVATE HALLWAY LOCATED AT APT 5A, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH
    Class AClosed
    Jun 6, 2024Apt 4E
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 4E, 4th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BClosed
    Jun 6, 2024Apt 5B
    REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
    § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 5B, 5th STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Jun 6, 2024Apt 5E
    REFIT DOORS ETC. · EGRESS
    § 27-2005 HMC: REFIT DOOR IN THE ENTRANCE LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class AClosed
    Jun 6, 2024Apt 5D
    REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
    § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 5D, 5th STORY, 5th APARTMENT FROM EAST AT SOUTH
    Class AClosed
    Jun 6, 2024Apt 4E
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 4E, 4th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BClosed
    Jun 6, 2024Apt 5B
    REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
    § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 5B, 5th STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Jun 6, 2024Apt 4B
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND SOUTH WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 4B, 4th STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class AClosed
    Jun 6, 2024Apt 9H
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ENTRANCE DOOR IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 9H, 9th STORY, 2nd APARTMENT FROM WEST AT NORTH
    Class BClosedRENT IMPAIRING
    Jun 6, 2024Apt 3K
    REMOVE ILLEGAL FASTENING · EGRESS
    § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING SLIDE BOLT INSTALLED AT INTERIOR SIDE OF DOOR, CAPABLE OF BEING PAD-LOCKED IN THE ENTRANCE LOCATED AT APT 3K, 3rd STORY, 4th APARTMENT FROM WEST AT NORTH
    Class BClosed
    Jun 5, 2024Apt 10J
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND EAST WALL IN THE BATHROOM LOCATED AT APT 10J, 10th STORY, 3rd APARTMENT FROM WEST AT NORTH
    Class BClosed
    Jun 5, 2024Apt 12H
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING, AND THE NORTH AND WEST WALLS IN THE 1st ROOM FROM NORTH LOCATED AT APT 12H, 12th STORY, 2nd APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Jun 5, 2024Apt 12E
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND SOUTH WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 12E, 12th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosedRENT IMPAIRING
    Jun 5, 2024Apt 10H
    REMOVE OBSTRUCTIONS · SEWERS AND DRAINAGE
    § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTELINE AT BATHTUB IN THE BATHROOM LOCATED AT APT 10H, 10th STORY, 2nd APARTMENT FROM WEST AT NORTH
    Class BClosed
    Jun 5, 2024Apt 12E
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 12E, 12th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Jun 5, 2024Apt 10J
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE EAST WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 10J, 10th STORY, 3rd APARTMENT FROM WEST AT NORTH
    Class BClosed
    Jun 5, 2024Apt 12H
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 12H, 12th STORY, 2nd APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Jun 5, 2024Apt 12B
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 12B, 12th STORY, 3rd APARTMENT FROM WEST AT NORTH
    Class AClosed
    Jun 4, 2024Apt 7L
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PLASTIC BASEBOARD MOULDING AT NORTH WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 7L, 7th STORY, 5th APARTMENT FROM WEST AT NORTH
    Class AClosed
    Jun 4, 2024Apt 8H
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE EAST WALL IN THE FOYER LOCATED AT APT 8H, 8th STORY, 2nd APARTMENT FROM WEST AT NORTH
    Class AClosed
    Jun 4, 2024Apt 7E
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 7E, 7th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class AClosed
    Jun 4, 2024Apt 7E
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 7E, 7th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class AClosed
    Jun 4, 2024Apt 8H
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING AROUND BATHTUB IN THE BATHROOM LOCATED AT APT 8H, 8th STORY, 2nd APARTMENT FROM WEST AT NORTH
    Class CClosed
    Jun 4, 2024Apt 7E
    MAKE DOORS SELF-CLOSING · EGRESS
    § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ''HINGES'' IN THE ENTRANCE LOCATED AT APT 7E, 7th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BClosedRENT IMPAIRING
    Jun 4, 2024Apt 6L
    REMOVE OBSTRUCTIONS · SEWERS AND DRAINAGE
    § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN DRAIN PIPE AT BATHTUB IN THE BATHROOM LOCATED AT APT 6L, 6th STORY, 5th APARTMENT FROM WEST AT NORTH
    Page 10 of 44
    ← PrevNext →