stoop
MAP
LeaderboardAbout
Building SafetyHousing Conditions

1077 CASTLETON AVENUE

Staten Island · ZIP 10310 · BIN 5095819 · West New Brighton-Silver Lake-Grymes Hill · Last violation Sep 16, 2026 · Last complaint Nov 14, 2026

NeighborhoodWest New Brighton-Silver Lake-Grymes Hill
More violations than 86% of nearby buildings
More violations than 86% of buildings and more complaints than 81% of buildings in West New Brighton-Silver Lake-Grymes Hill. Size-normalized against residential buildings in the neighborhood for issues in the last 10 years.
ViolationsComplaints
Activity TrendsLast 5 years
More activity recently than in past years
Last 2 yrs: 98 violations · 49 complaints
'24'26ViolationsComplaints
▼ View all activity over time
Severityⓘopen violations
1 hazardous (Class B) violation still open
Class B violations are hazardous conditions. Landlords must correct them within 30 days.
Class Cimmediately hazardous0Class Bhazardous1

What to watch forⓘ

  1. Heat or hot water problems reported in the last five years.
    Worth checking · AI-assistedⓘ
    Turn on hot water at the kitchen sink and bathroom sink and feel the water temperature after running for one minute.
    details ▸

    Heat is required October 1 through May 31: at least 68°F from 6am to 10pm when it is below 55°F outside, and 62°F overnight whatever the temperature outside. Hot water must be at least 120°F, 24 hours a day, all year.

    If your apartment is colder than that, file a complaint with 311 and keep the service request number so you can track it. Never use a gas oven or range for heat, which can produce dangerous levels of carbon monoxide.

    • ABCs of Housing
Housing Preservation & Development Violations
Total violations since 2024
103
34 per year avg.↑ Up 3167% in the last 2 years (98 vs 3 prior 2 yrs)
Open violations
1
Class C (immed. haz.)ⓘ0
Class B (hazardous)ⓘ1
Rent-impairingⓘ0
Housing Preservation & Development Complaints
Total complaints since 2024
54
18 per year avg.↑ Up 880% in the last 2 years (49 vs 5 prior 2 yrs)
Complaint Resolution
No access20%Violation issued15%No violation33%Phone resolved30%Other2%(54)
Urgency breakdown
Last 12 mo.

Top violation categories

5 yrsAll time
Posting/Signageⓘ22 violations
Egressⓘ20 violations
Maintenanceⓘ14 violations
Heat And Hot Waterⓘ9 violations
Water Supplyⓘ8 violations
Paintingⓘ6 violations
Carbon Monoxide Detecting Devicesⓘ6 violations
Annual Property Registrationⓘ5 violations
Top complaint groupsⓘ
5 yrsAll time
Heat / hot waterⓘ32 complaints
Water & plumbingⓘ13 complaints
Electricalⓘ4 complaints
Bldg maintenanceⓘ3 complaints
Hide violations ↑See complaints →

Violation log

23 violations · Class B

All classesClass AClass BClass CClass IAllOpenClosed
ClassStatusApt
See something wrong? File a complaint with 311
Open violation ages
▪ 3–12 months100% (1)
Prior 4 yr.
Immed. Emergency8%10%
Emergency67%80%
Non-Emergency25%10%
(24)
(30)
Issued
Description
Class BClosed—Sep 16, 2026REFIT DOORS ETC. · EGRESS§ 27-2005 HMC: REFIT THE FIRE DOOR AT WEST AT PUBLIC HALL, 1st STORY
Class BClosed—Jul 27, 2026REFIT DOORS ETC. · EGRESS§ 27-2005 HMC: REFIT DOOR LEADING TO FIRE STAIRS AT WEST AT PUBLIC HALL, 1st STORY
Class BClosed2AJul 21, 2026REPAIR LEAKY FAUCETS · WATER SUPPLY§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 2A, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BClosed2AJul 7, 2026REMOVE BARS OR GATES FROM FIRE ESCAPE WINDOW · EGRESS§ 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BClosed—Jul 6, 2026REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CONCRETE FLOOR OF 1ST LANDING FROM BOTTOM UP AT STAIR ''A'' AT PUBLIC HALL STAIRS, 1st STORY
Class BClosed—Apr 6, 2026ADJUST DOOR TO PREVENT GAP - FIRE CODE/EGRESS · EGRESS28 RCNY § 25-171; & 67 (7)(B) MDL; NYC FIRE CODE § 703.1.3; NYC FIRE CODE § 703.2: ADJUST DOOR TO PREVENT GAPS BETWEEN THE TOP AND SIDE EDGES OF DOOR AND DOOR JAMB EXCEEDING THE MAXIMUM ALLOWABLE CLEARANCE OF 1/8 OF AN INCH AND MAXIMUM ALLOWABLE CLEARANCE OF 3/4 OF AN INCH BETWEEN THE DOOR BOTTOM AND SILL AT COMPACTOR CLOSET AT WEST AT PUBLIC HALL, 2nd STORY
Class BClosed—Apr 6, 2026REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT ALL WALLS AND CEILING AT COMPACTOR CLOSET AT WEST AT PUBLIC HALL, 2nd STORY
Class BClosed2AMar 30, 2026REPAIR LEAKY FAUCETS · WATER SUPPLY§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 2A, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BClosedAPT2DFeb 23, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT APT2D, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BClosedAPT2DFeb 23, 2026REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK ABOVE CEILING IN THE BATHROOM LOCATED AT APT APT2D, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BOpenAPT2DFeb 23, 2026TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10 SQ FT AT EAST WALL IN THE BATHROOM LOCATED AT APT APT2D, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BClosed2DFeb 18, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BClosed—Nov 18, 2025REMOVE ACCUMULATION OR RUBBISH · CLEANING§ 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE FRONT YARD
Class BClosed3GJun 27, 2025REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosed3GJun 27, 2025REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN THE PRIVATE HALLWAY LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosed3GJun 27, 2025PROVIDE SUPPLY OF ELECTRICTY TO FIXTURES · ARTIFICIAL LIGHTING§ 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosed3GJun 27, 2025REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL IN THE PRIVATE HALLWAY LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosed4HMay 20, 2025REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND CEILING IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 4H, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BClosed4HMay 20, 2025REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 4H, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BClosed—Apr 21, 2025REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT PLASTER AT CEILING AT PUBLIC HALL, 1st STORY
Class BClosed—Apr 21, 2025REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT PLASTER AT CEILING AT PUBLIC HALL, 8th STORY
Class BClosed7AApr 7, 2025REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 7A, 7th STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BClosed7AApr 7, 2025REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 7A, 7th STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BClosed
Sep 16, 2026
REFIT DOORS ETC. · EGRESS
§ 27-2005 HMC: REFIT THE FIRE DOOR AT WEST AT PUBLIC HALL, 1st STORY
Class BClosed
Jul 27, 2026
REFIT DOORS ETC. · EGRESS
§ 27-2005 HMC: REFIT DOOR LEADING TO FIRE STAIRS AT WEST AT PUBLIC HALL, 1st STORY
Class BClosed
Jul 21, 2026Apt 2A
REPAIR LEAKY FAUCETS · WATER SUPPLY
§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 2A, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BClosed
Jul 7, 2026Apt 2A
REMOVE BARS OR GATES FROM FIRE ESCAPE WINDOW · EGRESS
§ 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BClosed
Jul 6, 2026
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CONCRETE FLOOR OF 1ST LANDING FROM BOTTOM UP AT STAIR ''A'' AT PUBLIC HALL STAIRS, 1st STORY
Class BClosed
Apr 6, 2026
ADJUST DOOR TO PREVENT GAP - FIRE CODE/EGRESS · EGRESS
28 RCNY § 25-171; & 67 (7)(B) MDL; NYC FIRE CODE § 703.1.3; NYC FIRE CODE § 703.2: ADJUST DOOR TO PREVENT GAPS BETWEEN THE TOP AND SIDE EDGES OF DOOR AND DOOR JAMB EXCEEDING THE MAXIMUM ALLOWABLE CLEARANCE OF 1/8 OF AN INCH AND MAXIMUM ALLOWABLE CLEARANCE OF 3/4 OF AN INCH BETWEEN THE DOOR BOTTOM AND SILL AT COMPACTOR CLOSET AT WEST AT PUBLIC HALL, 2nd STORY
Class BClosed
Apr 6, 2026
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT ALL WALLS AND CEILING AT COMPACTOR CLOSET AT WEST AT PUBLIC HALL, 2nd STORY
Class BClosed
Mar 30, 2026Apt 2A
REPAIR LEAKY FAUCETS · WATER SUPPLY
§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 2A, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BClosed
Feb 23, 2026Apt APT2D
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT APT2D, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BClosed
Feb 23, 2026Apt APT2D
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK ABOVE CEILING IN THE BATHROOM LOCATED AT APT APT2D, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BOpen
Feb 23, 2026Apt APT2D
TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10 SQ FT AT EAST WALL IN THE BATHROOM LOCATED AT APT APT2D, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BClosed
Feb 18, 2026Apt 2D
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BClosed
Nov 18, 2025
REMOVE ACCUMULATION OR RUBBISH · CLEANING
§ 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE FRONT YARD
Class BClosed
Jun 27, 2025Apt 3G
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosed
Jun 27, 2025Apt 3G
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN THE PRIVATE HALLWAY LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosed
Jun 27, 2025Apt 3G
PROVIDE SUPPLY OF ELECTRICTY TO FIXTURES · ARTIFICIAL LIGHTING
§ 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosed
Jun 27, 2025Apt 3G
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL IN THE PRIVATE HALLWAY LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosed
May 20, 2025Apt 4H
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND CEILING IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 4H, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BClosed
May 20, 2025Apt 4H
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 4H, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BClosed
Apr 21, 2025
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT PLASTER AT CEILING AT PUBLIC HALL, 1st STORY
Class BClosed
Apr 21, 2025
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT PLASTER AT CEILING AT PUBLIC HALL, 8th STORY
Class BClosed
Apr 7, 2025Apt 7A
REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 7A, 7th STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BClosed
Apr 7, 2025Apt 7A
REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 7A, 7th STORY, 2nd APARTMENT FROM SOUTH AT WEST