Class AOpen
Sep 11, 2025Apt C6
PAINT · PAINTING
§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING IN THE BATHROOM LOCATED AT APT C6, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH
Class AOpen
Sep 11, 2025Apt C6
PAINT · PAINTING
§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE EAST WALL, WAINSCOTTING AT NORTH WALL, CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT C6, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH
Class AOpen
Sep 11, 2025Apt C6
PAINT METAL · PAINTING
§ 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE 1st RADIATOR FROM WEST AT NORTH WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT C6, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH
Class COpen
Sep 11, 2025Apt C6
INSTALL/REPLACE/REPAIR WINDOW GUARDS (APT) · WINDOW GUARDS
§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 2, WG TO REPLACE = 0, WG TO REPAIR = 0 IN THE ENTIRE APARTMENT LOCATED AT APT C6, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH
Class AOpen
Sep 11, 2025Apt C6
PAINT · PAINTING
§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE PRIVATE HALLWAY , THE 1st ROOM FROM EAST LOCATED AT APT C6, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH
Class BOpen
Aug 11, 2025Apt D6
REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT D6, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH
Class BOpen
Aug 11, 2025Apt D6
REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT D6, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH
Class AOpen
Aug 11, 2025
PAINT · PAINTING
§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE EAST WALL AT BULKHEAD AT PUBLIC HALL STAIRS, 4th STORY
Class BOpen
Aug 11, 2025
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDED PLASTER AT EAST WALL AT BULKHEAD AT PUBLIC HALL STAIRS, 4th STORY
Class BOpen
Aug 11, 2025
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT EAST WALL AT BULKHEAD AT PUBLIC HALL STAIRS, 4th STORY
Class BOpen
Aug 4, 2025Apt D6
REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT D6, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH
Class BOpen
Aug 4, 2025Apt D6
REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT D6, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH
Class COpen
Aug 4, 2025
REPAIR · MAINTENANCE
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE HEAVY DUTY LOCK ON DOOR AT BUILDING ENTRANCE , 1st STORY
Class COpenRENT IMPAIRING
Aug 1, 2025
REMOVE RODENT · EXTERMINATION & RODENT ERADICATION
567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND ALL UNDERLYING CAUSES CREATING THE PEST INFESTATIONS, BY USING INTEGRATED PEST MANAGEMENT (IPM), ELIMINATE ALL BURROW ENTRY AND PASSAGEWAYS, PEST NESTS, HOLES, GAPS OR CRACKS IN WALLS, CEILINGS, FLOORS, FIXING LEAKS AND MANAGING GARBAGE IN PUBLIC AREAS. EVIDENCE FOUND AT THROUGHOUT AT CELLAR
Class BOpen
Aug 1, 2025
REPAIR/ABATE UNSAFE WIRES · ARTIFICIAL LIGHTING
§ 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRING AT SOUTH WALL YARD, 1st STORY
Class COpenRENT IMPAIRING
Aug 1, 2025Apt D4
INADEQUATE HOT WATER · HEAT AND HOT WATER
§ 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT D4, 4th STORY, 1st APARTMENT FROM WEST AT NORTH
Class COpen
Aug 1, 2025
PROVIDE ACCESS TO BOILER ROOM · HEAT AND HOT WATER
§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM
Class COpen
Jul 31, 2025Apt B1
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE KITCHEN LOCATED AT APT B1, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BOpen
Jul 31, 2025
PROVIDE LIGHT - Not Less that 60 Watt incadescent · ARTIFICIAL LIGHTING
§ 27-2039 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION AT ALL CEILING FIXTURES ALL STORIES AT PUBLIC HALL
Class BOpenRENT IMPAIRING
Jul 31, 2025Apt B1
REMOVE OBSTRUCTIONS · SEWERS AND DRAINAGE
§ 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN AT WASTE PIPE WASHBASIN IN THE BATHROOM LOCATED AT APT B1, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BOpen
Jul 31, 2025Apt B1
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND CEILING IN THE PRIVATE HALLWAY LOCATED AT APT B1, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BOpen
Jul 31, 2025Apt B1
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND CEILING IN THE FOYER LOCATED AT APT B1, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BOpen
Jul 31, 2025Apt B1
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND CEILING IN THE KITCHEN LOCATED AT APT B1, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BOpen
Jul 31, 2025Apt B1
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND CEILING IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT B1, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BOpen
Jul 31, 2025Apt B1
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND CEILING IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT B1, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BOpen
Jul 31, 2025Apt B1
REPAIR · MAINTENANCE
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SOLID WOOD STOOL AT 1ST WINDOW FROM EAST IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT B1, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BOpen
Jul 31, 2025Apt B1
REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT B1, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BOpen
Jul 31, 2025Apt B1
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND CEILING IN THE BATHROOM LOCATED AT APT B1, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST
Class COpen
Jul 30, 2025
ABATE THE NUISANCE · MAINTENANCE
§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF GLASS AT BOTTOM LITE OF WINDOW CREATING CUT HAZARD AT PUBLIC HALL STAIRS, 2nd STORY
Class COpen
Jul 30, 2025
REPLACE · MAINTENANCE
§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING MORTISE LOCK AT BUILDING ENTRANCE DOOR , 1st STORY
Class COpenRENT IMPAIRING
Jul 29, 2025
REMOVE RODENT · EXTERMINATION & RODENT ERADICATION
567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND ALL UNDERLYING CAUSES CREATING THE PEST INFESTATIONS, BY USING INTEGRATED PEST MANAGEMENT (IPM), ELIMINATE ALL BURROW ENTRY AND PASSAGEWAYS, PEST NESTS, HOLES, GAPS OR CRACKS IN WALLS, CEILINGS, FLOORS, FIXING LEAKS AND MANAGING GARBAGE IN PUBLIC AREAS. EVIDENCE FOUND AT WEST YARD , 1st STORY
Class COpenRENT IMPAIRING
Jul 29, 2025Apt D4
INADEQUATE HOT WATER · HEAT AND HOT WATER
§ 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT D4, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class COpen
Jul 29, 2025
REPLACE · MAINTENANCE
§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING MORTISE LOCK AT BUILDING ENTRANCE DOOR , 1st STORY
Class BOpen
Jul 29, 2025Apt D4
REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT D4, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class COpen
Jul 29, 2025Apt D4
ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATION
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT D4, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BOpen
Jul 29, 2025Apt D4
REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT D4, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class COpenRENT IMPAIRING
Jul 28, 2025
REMOVE RODENT · EXTERMINATION & RODENT ERADICATION
567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND ALL UNDERLYING CAUSES CREATING THE PEST INFESTATIONS, BY USING INTEGRATED PEST MANAGEMENT (IPM), ELIMINATE ALL BURROW ENTRY AND PASSAGEWAYS, PEST NESTS, HOLES, GAPS OR CRACKS IN WALLS, CEILINGS, FLOORS, FIXING LEAKS AND MANAGING GARBAGE IN PUBLIC AREAS. EVIDENCE FOUND AT LIVING AND DEAD RATS AT CELLAR
Class COpen
Jul 28, 2025
PROVIDE SUPPLY OF ELECTRICTY TO FIXTURES · ARTIFICIAL LIGHTING
§ 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES PUBLIC HALL ALL STORIES
Class BOpen
Jul 28, 2025
REMOVE VERMIN · EXTERMINATION & RODENT ERADICATION
566 (B) 27-2021.4 HMC: ABATE THE NUISANCE CONSISTING OF PESTS. EVIDENCE OF WATER BUGS AT CELLAR
Class COpenRENT IMPAIRING
Jul 28, 2025
REMOVE RODENT · EXTERMINATION & RODENT ERADICATION
567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND ALL UNDERLYING CAUSES CREATING THE PEST INFESTATIONS, BY USING INTEGRATED PEST MANAGEMENT (IPM), ELIMINATE ALL BURROW ENTRY AND PASSAGEWAYS, PEST NESTS, HOLES, GAPS OR CRACKS IN WALLS, CEILINGS, FLOORS, FIXING LEAKS AND MANAGING GARBAGE IN PUBLIC AREAS. EVIDENCE FOUND AT RATS DROPPING 1st COURT FROM NORTH AT WEST
Class COpen
Jul 28, 2025
REPAIR · MAINTENANCE
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MORTISE LOCKING DEVICE AT DOOR ENTRANCE BUILDING , 1st STORY
Class AOpen
Jul 28, 2025
BROKEN FLOOR, PAVE WITH CONCRETE · PAVING AND GRADING
§ 27-2005 ADM CODE REMOVE THE BROKEN OR DEFECTIVE FLOORING AND PAVE THE FLOOR WITH 4 INCHES OF CONCRETE REAR 1st YARD FROM NORTH
Class BOpen
Jul 28, 2025
REPAIR · MAINTENANCE
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MAILBOXES FOR APARTMENTS :A4, B3, 7C, AND A2 AT PUBLIC HALL, 1st STORY
Class COpenRENT IMPAIRING
Jul 28, 2025Apt D5
INADEQUATE HOT WATER · HEAT AND HOT WATER
§ 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT D5, 4th STORY, 1st APARTMENT FROM NORTH AT EAST
Class COpen
Jul 28, 2025Apt D5
ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATION
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT D5, 4th STORY, 1st APARTMENT FROM NORTH AT EAST
Class COpen
Jul 28, 2025
PROVIDE SUPPLY OF ELECTRICTY TO FIXTURES · ARTIFICIAL LIGHTING
§ 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES . AT CELLAR
Class COpen
Jul 22, 2025
PROVIDE ACCESS TO BOILER ROOM · HEAT AND HOT WATER
§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED TO CELLAR AT BOILER ROOM
Class COpen
Jul 22, 2025Apt A3
ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATION
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT A3, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH
Class BOpen
Jul 22, 2025
REPAIR · MAINTENANCE
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BROKEN GLASS PANE AT DOOR AT BUILDING ENRANCE
Class COpenRENT IMPAIRING
Jul 22, 2025
REMOVE RODENT · EXTERMINATION & RODENT ERADICATION
567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND ALL UNDERLYING CAUSES CREATING THE PEST INFESTATIONS, BY USING INTEGRATED PEST MANAGEMENT (IPM), ELIMINATE ALL BURROW ENTRY AND PASSAGEWAYS, PEST NESTS, HOLES, GAPS OR CRACKS IN WALLS, CEILINGS, FLOORS, FIXING LEAKS AND MANAGING GARBAGE IN PUBLIC AREAS. EVIDENCE FOUND AT RATS AT BUILDING WEST COURT