stoop
MAP
LeaderboardAbout
Building SafetyHousing Conditions

473 WILSON AVENUE

Brooklyn · ZIP 11221 · BIN 3077973 · Bushwick (East) · Last violation Sep 23, 2026 · Last complaint Sep 30, 2026

NeighborhoodBushwick (East)
More violations than 100% of nearby buildings
More violations than 100% of buildings and more complaints than 100% of buildings in Bushwick (East). Size-normalized against residential buildings in the neighborhood for issues in the last 10 years.
ViolationsComplaints
Activity TrendsLast 5 years
A steady level of activity over time
Last 2 yrs: 184 violations · 323 complaints
'21'26ViolationsComplaints
▼ View all activity over time
Severityⓘopen violations
71 immediately hazardous (Class C) violations still open
Class C violations include lead paint, mold, pest infestations, heat/hot water failure, and structural hazards — the most serious category.
Class Cimmediately hazardous71Class Bhazardous68

What to watch forⓘ

  1. Hazardous violations are open, including building maintenance, mold and pests, and heat and hot water.
    Worth checking · AI-assistedⓘ
    Look at walls, ceilings, and structural elements for cracks, water damage, or deterioration that is plainly visible. Check cabinets, corners, and under sinks for signs of rodents, droppings, or live pests. Turn on the radiator or heating system and feel whether heat reaches the room within a few minutes.
    details ▸

    Deadlines vary by condition: immediate for heat and hot water, 14 days for self-closing doors, 21 days for lead paint, window guards, mold, and mice, cockroaches or rats, and 24 hours for everything else. They run from the date the owner is served, and mark when civil penalties can be sought in Housing Court. They are not a promise the condition is fixed by then. If the owner does not fix it, HPD can send its own contractor and bill them.

    • —Bldg maintenance — General building repair, upkeep, and maintenance related housing code violations.
    • —Mold & pests — Rodent, cockroach, bedbug, or other pest infestation and extermination related issues.
Housing Preservation & Development Violations
Total violations since 2007
885
44 per year avg.↑ Up 111% in the last 2 years (184 vs 87 prior 2 yrs)
Open violations
157
Class C (immed. haz.)ⓘ71
Class B (hazardous)ⓘ68
Rent-impairingⓘ13
Housing Preservation & Development Complaints
Total complaints since 2004
812
35 per year avg.↑ Up 618% in the last 2 years (323 vs 45 prior 2 yrs)
Complaint Resolution
No access13%Violation issued25%No violation30%Phone resolved30%Other2%(812)
Urgency breakdown
Last 12 mo.

Top violation categories

5 yrsAll time
Maintenanceⓘ141 violations
Heat And Hot Waterⓘ59 violations
Water Supplyⓘ39 violations
Egressⓘ34 violations
Extermination & Rodent Eradicationⓘ26 violations
Paintingⓘ22 violations
Artificial Lightingⓘ18 violations
Retiredⓘ15 violations
Top complaint groupsⓘ
5 yrsAll time
Heat / hot waterⓘ167 complaints
Water & plumbingⓘ61 complaints
Bldg maintenanceⓘ61 complaints
Mold & pestsⓘ57 complaints
Electricalⓘ24 complaints
Elevatorⓘ7 complaints
Appliancesⓘ7 complaints
Safety & fireⓘ4 complaints
Adminⓘ2 complaints
Hide violations ↑See complaints →

Violation log

157 violations · Open

All classesClass AClass BClass CClass IAllOpenClosed
ClassStatusApt
See something wrong? File a complaint with 311
—
Heat / hot water — Lack of heat, hot water, or heating system related issues affecting tenants.

The violation list below shows which conditions are open and when each was cited. If one in your own apartment is still unaddressed, call 311.

  • ABCs of Housing
  • NYC HPD, Penalties and Fees
  • Detector violations on record.
    Worth checking · AI-assistedⓘ
    Locate smoke detectors on the ceiling near bedrooms and in hallways, and ask the broker whether carbon monoxide detectors are present in the unit.
    details ▸

    Responsibility is split: the owner provides, installs, and replaces the detectors, while the tenant tests them monthly and replaces the batteries. An open violation means the owner has not yet certified to HPD that the condition was fixed, so a device may still be missing or dead at move-in. A tenant reimburses the owner for a newly installed device, $25 for a smoke or carbon monoxide detector and $50 for a combined unit, and is responsible for replacing one that goes missing or is damaged during the tenancy.

    On a viewing, look for a smoke alarm within fifteen feet of the door of each room used for sleeping, on the ceiling or just below it on the wall, and a carbon monoxide alarm at any height, including one plugged into a hallway outlet. Press the test button, and check that none have been painted over. A chirping alarm usually means a low battery, which is the tenant's to replace, but detectors also sound a separate end-of-life alarm when the device itself has to be replaced by the owner.

    • ABCs of Housing
    • NYC HPD, Smoke, Carbon Monoxide, and Natural Gas Detectors
  • Open violation ages
    ▪ < 30 days2% (3)
    ▪ 30–90 days21% (32)
    ▪ 3–12 months23% (36)
    ▪ 1–3 years15% (23)
    ▪ 3+ years40% (62)
    Prior 4 yr.
    Immed. Emergency2%6%
    Emergency64%65%
    Non-Emergency34%30%
    (225)
    (193)
    Issued
    Description
    Class COpen—May 22, 2026PROVIDE ACCESS TO BOILER ROOM · HEAT AND HOT WATER§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM
    Class AOpen—May 6, 2026FILE ANNUAL BEDBUG REPORT · FILING: BEDBUGS(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
    Class BOpen2RMay 1, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHEN LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class COpen—May 1, 2026PROVIDE ACCESS TO BOILER ROOM · HEAT AND HOT WATER§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM
    Class BOpen2RApr 21, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class COpen2RApr 21, 2026REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class COpen2RApr 21, 2026REPLACE · MAINTENANCE§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING LIGHT FIXTURE AT CEILING IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class COpen—Apr 21, 2026PROVIDE ACCESS TO BOILER ROOM · HEAT AND HOT WATER§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM
    Class COpen2RApr 21, 2026REPAIR/ABATE UNSAFE WIRES · ARTIFICIAL LIGHTING§ 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRING AT CELING IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class COpenRENT IMPAIRING3LJan 12, 2026INADEQUATE HEAT · HEAT AND HOT WATER§ 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
    Class COpen2RJan 12, 2026ABATE THE NUISANCE OF MICE · EXTERMINATION & RODENT ERADICATIONHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen2RJan 12, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHEN LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class COpen2RJan 12, 2026ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATIONHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class COpen—Jan 12, 2026PROVIDE ACCESS TO BOILER ROOM · HEAT AND HOT WATER§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT BOILER ROOM
    Class COpenRENT IMPAIRING3LJan 9, 2026INADEQUATE HEAT · HEAT AND HOT WATER§ 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BOpen—Jan 5, 2026REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT NORTH WALL AT PUBLIC HALL, 1st STORY
    Class AOpen—Jan 5, 2026PROVIDE SHOE FOR DROP LADDER · FIRE EGRESS AND PROTECTION§ 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER MISSING AT FIRE ESCAPE, SECTION ''FRONT BLDG''
    Class AOpen—Jan 5, 2026PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE NORTH WALL AT PUBLIC HALL, 1st STORY
    Class COpenRENT IMPAIRING3LDec 11, 2025INADEQUATE HOT WATER · HEAT AND HOT WATER§ 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST
    Class COpen—Nov 6, 2025PROVIDE ACCESS TO BOILER ROOM · HEAT AND HOT WATER§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM BILCO DOORS PADLOCKED LEADING FROM THE STREET TO THE CELLAR AT CELLAR
    Class BOpenRENT IMPAIRING—Nov 5, 2025PROVIDE A JANITOR · JANITORIAL SERVICES§ 27-2053 ADM CODE PROVIDE DWELLING WITH A JANITOR OR RESPONSIBLE PERSON OR JANITORIAL SERVICE.
    Class COpen2RSep 8, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE UPPER AND LOWER SASH AT WINDOW IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
    Class COpen2RSep 8, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER SASH AT WINDOW IN THE 2nd ROOM FROM EAST AT NORTH LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
    Class BOpen2RSep 8, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ENTRY DOOR IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
    Class BOpen2RSep 8, 2025REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR EAST WALL IN THE FOYER LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
    Class BOpen—Sep 8, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MAILBOXES AT NORTH WALL AT PUBLIC HALL, 1st STORY
    Class BOpen2RSep 8, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BELL, BUZZER AND RETURN INTERCOM SYSTEM FROM BUILDING FRONT ENTRANCE TO IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
    Class COpen2LSep 8, 2025ABATE THE NUISANCE OF MICE · EXTERMINATION & RODENT ERADICATIONHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
    Class AOpen2RSep 8, 2025PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AND NORTH WALL IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
    Class BOpen2LSep 8, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BELL, BUZZER AND RETURN INTERCOM SYSTEM FROM BUILDING FRONT ENTRANCE TO IN THE ENTIRE APARTMENT LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
    Class COpen2RSep 8, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE AT UPPER AND LOWER SASH AT WINDOW IN THE 3rd ROOM FROM EAST AT NORTH LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
    Class COpen2RSep 8, 2025ABATE THE NUISANCE OF MICE · EXTERMINATION & RODENT ERADICATIONHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
    Class AOpen—Sep 8, 2025PAINT METAL · PAINTING§ 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALL PARTS, ALL COMPONENTS, ALL STORIES BOTH EAST AND WEST STACKS AT BUILDING FRONT AT FIRE ESCAPE
    Class COpen—Aug 28, 2025REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BRICKS AND MORTAR ALL NORTH EXTERIOR WALL AT NORTH SIDE OF THE BUILDING
    Class COpen2LAug 21, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE APARTMENT ENTRANCE DOOR IN THE ENTRANCE LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
    Class AOpen—Aug 4, 2025PROVIDE SHOE FOR DROP LADDER · FIRE EGRESS AND PROTECTION§ 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER AT 1ST FIRE ESCAPE FROM NORTH AT EAST AT BUILDING FRONT
    Class BOpenRENT IMPAIRING—Jul 14, 2025REMOVE ENCUMBRANCES · EGRESS§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF CONSTUCTION MATERIALS AT BASEMENT STAIRS AT PUBLIC HALL, 1st STORY
    Class COpen—Jul 14, 2025MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT DOOR LEADING TO BASEMENT AT PUBLIC HALL, 1st STORY
    Class BOpen2RJun 20, 2025REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class AOpen2RJun 20, 2025REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING, SOUTH, AND NORTH WALLS IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class AOpen—Jun 11, 2025FILE ANNUAL BEDBUG REPORT · FILING: BEDBUGS(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
    Class BOpen—May 7, 2025REMOVE ENCUMBRANCE · EGRESS§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES WIRING ON DROPLADDER AT WEST STACK AT FIRE ESCAPE, 1st STORY
    Class BOpen2RMar 10, 2025REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE KITCHEN LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
    Class BOpen2RMar 10, 2025REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE SOUTH WALL AND THE CEILING IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
    Class BOpen2RSep 20, 2022TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILINGG IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 15171776 ISSUED 19-MAY-22 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).
    Class AOpen3LMay 23, 2022PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING IN THE BATHROOM LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BOpen2LFeb 14, 2022REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL BUZZER INTERCOM SYSTEM IN THE ENTIRE APARTMENT LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
    Class BOpen2RJan 28, 2022TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... (APPROX. 5 SQ FT) AT CEILING IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 14597044 ISSUED 28-SEP-21 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).
    Class BOpen3LOct 19, 2021REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCES AT LOWER SASH AT WINDOW AT NORTH WALL IN THE KITCHEN LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BOpen3LOct 19, 2021REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCES AT LOWER SASH AT WINDOW AT NORTH WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
    Class COpen
    May 22, 2026
    PROVIDE ACCESS TO BOILER ROOM · HEAT AND HOT WATER
    § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM
    Class AOpen
    May 6, 2026
    FILE ANNUAL BEDBUG REPORT · FILING: BEDBUGS
    (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
    Class BOpen
    May 1, 2026Apt 2R
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHEN LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class COpen
    May 1, 2026
    PROVIDE ACCESS TO BOILER ROOM · HEAT AND HOT WATER
    § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM
    Class BOpen
    Apr 21, 2026Apt 2R
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class COpen
    Apr 21, 2026Apt 2R
    REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
    § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class COpen
    Apr 21, 2026Apt 2R
    REPLACE · MAINTENANCE
    § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING LIGHT FIXTURE AT CEILING IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class COpen
    Apr 21, 2026
    PROVIDE ACCESS TO BOILER ROOM · HEAT AND HOT WATER
    § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM
    Class COpen
    Apr 21, 2026Apt 2R
    REPAIR/ABATE UNSAFE WIRES · ARTIFICIAL LIGHTING
    § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRING AT CELING IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class COpenRENT IMPAIRING
    Jan 12, 2026Apt 3L
    INADEQUATE HEAT · HEAT AND HOT WATER
    § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
    Class COpen
    Jan 12, 2026Apt 2R
    ABATE THE NUISANCE OF MICE · EXTERMINATION & RODENT ERADICATION
    HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Jan 12, 2026Apt 2R
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHEN LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class COpen
    Jan 12, 2026Apt 2R
    ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATION
    HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class COpen
    Jan 12, 2026
    PROVIDE ACCESS TO BOILER ROOM · HEAT AND HOT WATER
    § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT BOILER ROOM
    Class COpenRENT IMPAIRING
    Jan 9, 2026Apt 3L
    INADEQUATE HEAT · HEAT AND HOT WATER
    § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BOpen
    Jan 5, 2026
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT NORTH WALL AT PUBLIC HALL, 1st STORY
    Class AOpen
    Jan 5, 2026
    PROVIDE SHOE FOR DROP LADDER · FIRE EGRESS AND PROTECTION
    § 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER MISSING AT FIRE ESCAPE, SECTION ''FRONT BLDG''
    Class AOpen
    Jan 5, 2026
    PAINT · PAINTING
    § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE NORTH WALL AT PUBLIC HALL, 1st STORY
    Class COpenRENT IMPAIRING
    Dec 11, 2025Apt 3L
    INADEQUATE HOT WATER · HEAT AND HOT WATER
    § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST
    Class COpen
    Nov 6, 2025
    PROVIDE ACCESS TO BOILER ROOM · HEAT AND HOT WATER
    § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM BILCO DOORS PADLOCKED LEADING FROM THE STREET TO THE CELLAR AT CELLAR
    Class BOpenRENT IMPAIRING
    Nov 5, 2025
    PROVIDE A JANITOR · JANITORIAL SERVICES
    § 27-2053 ADM CODE PROVIDE DWELLING WITH A JANITOR OR RESPONSIBLE PERSON OR JANITORIAL SERVICE.
    Class COpen
    Sep 8, 2025Apt 2R
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE UPPER AND LOWER SASH AT WINDOW IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
    Class COpen
    Sep 8, 2025Apt 2R
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER SASH AT WINDOW IN THE 2nd ROOM FROM EAST AT NORTH LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
    Class BOpen
    Sep 8, 2025Apt 2R
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ENTRY DOOR IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
    Class BOpen
    Sep 8, 2025Apt 2R
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR EAST WALL IN THE FOYER LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
    Class BOpen
    Sep 8, 2025
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MAILBOXES AT NORTH WALL AT PUBLIC HALL, 1st STORY
    Class BOpen
    Sep 8, 2025Apt 2R
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BELL, BUZZER AND RETURN INTERCOM SYSTEM FROM BUILDING FRONT ENTRANCE TO IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
    Class COpen
    Sep 8, 2025Apt 2L
    ABATE THE NUISANCE OF MICE · EXTERMINATION & RODENT ERADICATION
    HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
    Class AOpen
    Sep 8, 2025Apt 2R
    PAINT · PAINTING
    § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AND NORTH WALL IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
    Class BOpen
    Sep 8, 2025Apt 2L
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BELL, BUZZER AND RETURN INTERCOM SYSTEM FROM BUILDING FRONT ENTRANCE TO IN THE ENTIRE APARTMENT LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
    Class COpen
    Sep 8, 2025Apt 2R
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE AT UPPER AND LOWER SASH AT WINDOW IN THE 3rd ROOM FROM EAST AT NORTH LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
    Class COpen
    Sep 8, 2025Apt 2R
    ABATE THE NUISANCE OF MICE · EXTERMINATION & RODENT ERADICATION
    HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
    Class AOpen
    Sep 8, 2025
    PAINT METAL · PAINTING
    § 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALL PARTS, ALL COMPONENTS, ALL STORIES BOTH EAST AND WEST STACKS AT BUILDING FRONT AT FIRE ESCAPE
    Class COpen
    Aug 28, 2025
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BRICKS AND MORTAR ALL NORTH EXTERIOR WALL AT NORTH SIDE OF THE BUILDING
    Class COpen
    Aug 21, 2025Apt 2L
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE APARTMENT ENTRANCE DOOR IN THE ENTRANCE LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
    Class AOpen
    Aug 4, 2025
    PROVIDE SHOE FOR DROP LADDER · FIRE EGRESS AND PROTECTION
    § 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER AT 1ST FIRE ESCAPE FROM NORTH AT EAST AT BUILDING FRONT
    Class BOpenRENT IMPAIRING
    Jul 14, 2025
    REMOVE ENCUMBRANCES · EGRESS
    § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF CONSTUCTION MATERIALS AT BASEMENT STAIRS AT PUBLIC HALL, 1st STORY
    Class COpen
    Jul 14, 2025
    MAKE DOORS SELF-CLOSING · EGRESS
    § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT DOOR LEADING TO BASEMENT AT PUBLIC HALL, 1st STORY
    Class BOpen
    Jun 20, 2025Apt 2R
    REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
    § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class AOpen
    Jun 20, 2025Apt 2R
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING, SOUTH, AND NORTH WALLS IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class AOpen
    Jun 11, 2025
    FILE ANNUAL BEDBUG REPORT · FILING: BEDBUGS
    (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
    Class BOpen
    May 7, 2025
    REMOVE ENCUMBRANCE · EGRESS
    § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES WIRING ON DROPLADDER AT WEST STACK AT FIRE ESCAPE, 1st STORY
    Class BOpen
    Mar 10, 2025Apt 2R
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE KITCHEN LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
    Class BOpen
    Mar 10, 2025Apt 2R
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE SOUTH WALL AND THE CEILING IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
    Class BOpen
    Sep 20, 2022Apt 2R
    TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
    § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILINGG IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 15171776 ISSUED 19-MAY-22 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).
    Class AOpen
    May 23, 2022Apt 3L
    PAINT · PAINTING
    § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING IN THE BATHROOM LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BOpen
    Feb 14, 2022Apt 2L
    REPAIR · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL BUZZER INTERCOM SYSTEM IN THE ENTIRE APARTMENT LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
    Class BOpen
    Jan 28, 2022Apt 2R
    TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
    § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... (APPROX. 5 SQ FT) AT CEILING IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 14597044 ISSUED 28-SEP-21 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).
    Class BOpen
    Oct 19, 2021Apt 3L
    REPAIR · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCES AT LOWER SASH AT WINDOW AT NORTH WALL IN THE KITCHEN LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BOpen
    Oct 19, 2021Apt 3L
    REPAIR · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCES AT LOWER SASH AT WINDOW AT NORTH WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
    Page 2 of 4