stoop
MAP
LeaderboardAbout
Building SafetyHousing Conditions

277 GATES AVENUE

Brooklyn · ZIP 11216 · BIN 3056589 · Bedford-Stuyvesant (West) · Last violation Nov 12, 2026 · Last complaint Nov 17, 2026

NeighborhoodBedford-Stuyvesant (West)
More violations than 98% of nearby buildings
More violations than 98% of buildings and more complaints than 99% of buildings in Bedford-Stuyvesant (West). Size-normalized against residential buildings in the neighborhood for issues in the last 10 years.
ViolationsComplaints
Activity TrendsLast 5 years
More activity recently than in past years
Last 2 yrs: 307 violations · 497 complaints
'21'26ViolationsComplaints
▼ View all activity over time
Severityⓘopen violations
50 immediately hazardous (Class C) violations still open
Class C violations include lead paint, mold, pest infestations, heat/hot water failure, and structural hazards — the most serious category.
Class Cimmediately hazardous50Class Bhazardous209

What to watch forⓘ

  1. Hazardous violations are open, including building maintenance, mold and pests, and heat and hot water.
    Worth checking · AI-assistedⓘ
    Look at walls, ceilings, and structural elements for cracks, water damage, or deterioration that is plainly visible. Check cabinets, corners, and under sinks for signs of rodents, droppings, or live pests. Turn on the radiator or heating system and feel whether heat reaches the room within a few minutes.
    details ▸

    Deadlines vary by condition: immediate for heat and hot water, 14 days for self-closing doors, 21 days for lead paint, window guards, mold, and mice, cockroaches or rats, and 24 hours for everything else. They run from the date the owner is served, and mark when civil penalties can be sought in Housing Court. They are not a promise the condition is fixed by then. If the owner does not fix it, HPD can send its own contractor and bill them.

    • —Bldg maintenance — General building repair, upkeep, and maintenance related housing code violations.
    • —Mold & pests — Rodent, cockroach, bedbug, or other pest infestation and extermination related issues.
Housing Preservation & Development Violations
Total violations since 2010
666
39 per year avg.↑ Up 94% in the last 2 years (307 vs 158 prior 2 yrs)
Open violations
322
Class C (immed. haz.)ⓘ50
Class B (hazardous)ⓘ209
Rent-impairingⓘ31
Housing Preservation & Development Complaints
Total complaints since 2004
1,660
72 per year avg.↑ Up 215% in the last 2 years (497 vs 158 prior 2 yrs)
Complaint Resolution
No access19%Violation issued15%No violation45%Phone resolved21%Other0%(1,660)
Urgency breakdown
Last 12 mo.

Top violation categories

5 yrsAll time
Maintenanceⓘ219 violations
Water Supplyⓘ45 violations
Egressⓘ40 violations
Heat And Hot Waterⓘ37 violations
Carbon Monoxide Detecting Devicesⓘ29 violations
Cleaningⓘ29 violations
Smoke Detecting Devicesⓘ25 violations
Paintingⓘ22 violations
Top complaint groupsⓘ
5 yrsAll time
Heat / hot waterⓘ198 complaints
Mold & pestsⓘ129 complaints
Bldg maintenanceⓘ121 complaints
Water & plumbingⓘ115 complaints
Safety & fireⓘ35 complaints
Electricalⓘ30 complaints
Appliancesⓘ12 complaints
Elevatorⓘ7 complaints
Outdoor / structuralⓘ4 complaints
Adminⓘ1 complaints
Hide violations ↑See complaints →

Violation log

363 violations · Class B

All classesClass AClass BClass CClass IAllOpenClosed
ClassStatusApt
See something wrong? File a complaint with 311
—
Heat / hot water — Lack of heat, hot water, or heating system related issues affecting tenants.

The violation list below shows which conditions are open and when each was cited. If one in your own apartment is still unaddressed, call 311.

  • ABCs of Housing
  • NYC HPD, Penalties and Fees
  • Detector violations on record.
    Worth checking · AI-assistedⓘ
    Locate smoke detectors on the ceiling near bedrooms and in hallways, and ask the broker whether carbon monoxide detectors are present in the unit.
    details ▸

    Responsibility is split: the owner provides, installs, and replaces the detectors, while the tenant tests them monthly and replaces the batteries. An open violation means the owner has not yet certified to HPD that the condition was fixed, so a device may still be missing or dead at move-in. A tenant reimburses the owner for a newly installed device, $25 for a smoke or carbon monoxide detector and $50 for a combined unit, and is responsible for replacing one that goes missing or is damaged during the tenancy.

    On a viewing, look for a smoke alarm within fifteen feet of the door of each room used for sleeping, on the ceiling or just below it on the wall, and a carbon monoxide alarm at any height, including one plugged into a hallway outlet. Press the test button, and check that none have been painted over. A chirping alarm usually means a low battery, which is the tenant's to replace, but detectors also sound a separate end-of-life alarm when the device itself has to be replaced by the owner.

    • ABCs of Housing
    • NYC HPD, Smoke, Carbon Monoxide, and Natural Gas Detectors
  • Open violation ages
    ▪ < 30 days14% (45)
    ▪ 30–90 days46% (149)
    ▪ 3–12 months12% (39)
    ▪ 1–3 years16% (50)
    ▪ 3+ years12% (39)
    Prior 4 yr.
    Immed. Emergency2%2%
    Emergency65%55%
    Non-Emergency33%43%
    (333)
    (399)
    Issued
    Description
    Class BOpen2BSep 8, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen6DSep 8, 2026REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER WINDOW SASH IN THE 1st ROOM FROM EAST LOCATED AT APT 6D, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''west'', 1st FROM SOUTH AT WEST
    Class BOpenRENT IMPAIRING6DSep 8, 2026LEAKY ROOF · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK ABOVE CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 6D, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BOpen2DSep 8, 2026REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING AROUND THE BASE CABINET COUNTER TOP AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BOpen2DSep 8, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING, NORTH, EAST AND WEST WALLS IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BOpen6DSep 8, 2026REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 6D, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BOpen2DSep 8, 2026REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT WEST WALL IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BOpen2BSep 8, 2026REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen2BSep 8, 2026REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen2DSep 8, 2026REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 2D , 2nd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BOpen2DSep 8, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''WEST''
    Class BOpen2DSep 8, 2026REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''WEST''
    Class BOpen2DSep 8, 2026REPAIR LEAKY FAUCETS · WATER SUPPLY§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BOpen2DSep 8, 2026REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BOpen6DSep 8, 2026REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 6D, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BOpen6DSep 8, 2026REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 6D, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BOpen6DSep 8, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 6D, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BOpenRENT IMPAIRING6DSep 8, 2026LEAKY ROOF · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 6D, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BOpen5BSep 3, 2026PROVIDE SUPPLY OF ELECTRICTY TO FIXTURES · ARTIFICIAL LIGHTING§ 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES TO THE 2ND ELECTRICAL FIXTURE FROM EAST AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen5BSep 3, 2026REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen6DSep 1, 2026REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 6D, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''west'', 1st FROM SOUTH AT WEST
    Class BOpen6DSep 1, 2026REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 6D, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''west'', 1st FROM SOUTH AT WEST
    Class BOpen6DSep 1, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND EAST WALL IN THE BATHROOM LOCATED AT APT 6D, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''west'', 1st FROM SOUTH AT WEST
    Class BOpen—Sep 1, 2026REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL CEILING AT PUBLIC HALL, 6th STORY
    Class BOpen6DSep 1, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND EAST WALL IN THE KITCHEN LOCATED AT APT 6D, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''west'', 1st FROM SOUTH AT WEST
    Class BOpen5ESep 1, 2026REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''west'', 1st FROM SOUTH AT WEST
    Class BOpen5ESep 1, 2026REPAIR/ABATE UNSAFE WIRES · ARTIFICIAL LIGHTING§ 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF CEILING AND EAST WALL IN THE KITCHEN LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''west'', 1st FROM SOUTH AT WEST
    Class BOpen—Aug 17, 2026REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT PUBLIC HALL, 6th STORY
    Class BOpenRENT IMPAIRING—Aug 17, 2026LEAKY ROOF · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING AT PUBLIC HALL, 6th STORY
    Class BOpen4BJul 22, 2026REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMEL FINISH AT BATHTUB BY THE METHOD OF REGLAZING IN THE BATHROOM LOCATED AT APT 4B, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpenRENT IMPAIRING3AJun 17, 2026REPAIR LEAKY PIPES · WATER SUPPLY§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE WATER SUPPLY PIPE AT SINK IN THE KITCHEN LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BOpen3AJun 17, 2026REPAIR LEAKY FAUCETS · WATER SUPPLY§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BOpen3AJun 17, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BOpen3AJun 15, 2026REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH
    Class BOpen3AJun 15, 2026REPAIR LEAKY FAUCETS · WATER SUPPLY§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 3A, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH
    Class BOpen3AJun 15, 2026REPAIR BROKEN, LOOSE CONNECTION · SEWERS AND DRAINAGE§ 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT SINK WASTE LINE IN THE KITCHEN LOCATED AT APT 3A, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH
    Class BOpen—Jun 15, 2026REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MORISE LOCK VESTIBULE DOOR AT PUBLIC HALL, 1st STORY
    Class BOpen2DJun 10, 2026ABATE THE NUISANCE · MAINTENANCE§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HEAT ON IN SUMMER IN THE ENTIRE APARTMENT LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''WEST''
    Class BOpen2DJun 9, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL AND CEILING IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''WEST''
    Class BOpenRENT IMPAIRING2DJun 9, 2026REMOVE OBSTRUCTIONS · SEWERS AND DRAINAGE§ 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTE LINE AT WASHBASIN IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''WEST''
    Class BOpen3BMay 28, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen3BMay 28, 2026REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen3BMay 28, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND EAST WALL IN THE BATHROOM LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen2DFeb 12, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL, WEST WALL AND CEILING IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen2BFeb 12, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen2DFeb 12, 2026REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING AROUND WOOD COUNTER TOP IN THE KITCHEN LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen2DFeb 12, 2026REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MECHANICAL VENTILATION AT CEILING IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen2BFeb 12, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND EAST WALL IN THE BATHROOM LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen3AJan 9, 2026REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOCK AND ASSEMBLY IN THE ENTRANCE LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''EAST''
    Class BOpenRENT IMPAIRING—Oct 20, 2025LEAKY ROOF · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING AT PUBLIC HALL, 6th STORY
    Class BOpen
    Sep 8, 2026Apt 2B
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Sep 8, 2026Apt 6D
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER WINDOW SASH IN THE 1st ROOM FROM EAST LOCATED AT APT 6D, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''west'', 1st FROM SOUTH AT WEST
    Class BOpenRENT IMPAIRING
    Sep 8, 2026Apt 6D
    LEAKY ROOF · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK ABOVE CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 6D, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Sep 8, 2026Apt 2D
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING AROUND THE BASE CABINET COUNTER TOP AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Sep 8, 2026Apt 2D
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING, NORTH, EAST AND WEST WALLS IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Sep 8, 2026Apt 6D
    REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
    § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 6D, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Sep 8, 2026Apt 2D
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT WEST WALL IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Sep 8, 2026Apt 2B
    REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
    § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Sep 8, 2026Apt 2B
    REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
    § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Sep 8, 2026Apt 2D
    REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
    § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 2D , 2nd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Sep 8, 2026Apt 2D
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''WEST''
    Class BOpen
    Sep 8, 2026Apt 2D
    REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
    § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''WEST''
    Class BOpen
    Sep 8, 2026Apt 2D
    REPAIR LEAKY FAUCETS · WATER SUPPLY
    § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Sep 8, 2026Apt 2D
    REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
    § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Sep 8, 2026Apt 6D
    REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
    § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 6D, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Sep 8, 2026Apt 6D
    REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
    § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 6D, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Sep 8, 2026Apt 6D
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 6D, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BOpenRENT IMPAIRING
    Sep 8, 2026Apt 6D
    LEAKY ROOF · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 6D, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Sep 3, 2026Apt 5B
    PROVIDE SUPPLY OF ELECTRICTY TO FIXTURES · ARTIFICIAL LIGHTING
    § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES TO THE 2ND ELECTRICAL FIXTURE FROM EAST AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Sep 3, 2026Apt 5B
    REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
    § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Sep 1, 2026Apt 6D
    REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
    § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 6D, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''west'', 1st FROM SOUTH AT WEST
    Class BOpen
    Sep 1, 2026Apt 6D
    REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
    § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 6D, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''west'', 1st FROM SOUTH AT WEST
    Class BOpen
    Sep 1, 2026Apt 6D
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND EAST WALL IN THE BATHROOM LOCATED AT APT 6D, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''west'', 1st FROM SOUTH AT WEST
    Class BOpen
    Sep 1, 2026
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL CEILING AT PUBLIC HALL, 6th STORY
    Class BOpen
    Sep 1, 2026Apt 6D
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND EAST WALL IN THE KITCHEN LOCATED AT APT 6D, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''west'', 1st FROM SOUTH AT WEST
    Class BOpen
    Sep 1, 2026Apt 5E
    REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
    § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''west'', 1st FROM SOUTH AT WEST
    Class BOpen
    Sep 1, 2026Apt 5E
    REPAIR/ABATE UNSAFE WIRES · ARTIFICIAL LIGHTING
    § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF CEILING AND EAST WALL IN THE KITCHEN LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''west'', 1st FROM SOUTH AT WEST
    Class BOpen
    Aug 17, 2026
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT PUBLIC HALL, 6th STORY
    Class BOpenRENT IMPAIRING
    Aug 17, 2026
    LEAKY ROOF · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING AT PUBLIC HALL, 6th STORY
    Class BOpen
    Jul 22, 2026Apt 4B
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMEL FINISH AT BATHTUB BY THE METHOD OF REGLAZING IN THE BATHROOM LOCATED AT APT 4B, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpenRENT IMPAIRING
    Jun 17, 2026Apt 3A
    REPAIR LEAKY PIPES · WATER SUPPLY
    § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE WATER SUPPLY PIPE AT SINK IN THE KITCHEN LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BOpen
    Jun 17, 2026Apt 3A
    REPAIR LEAKY FAUCETS · WATER SUPPLY
    § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BOpen
    Jun 17, 2026Apt 3A
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BOpen
    Jun 15, 2026Apt 3A
    REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
    § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH
    Class BOpen
    Jun 15, 2026Apt 3A
    REPAIR LEAKY FAUCETS · WATER SUPPLY
    § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 3A, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH
    Class BOpen
    Jun 15, 2026Apt 3A
    REPAIR BROKEN, LOOSE CONNECTION · SEWERS AND DRAINAGE
    § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT SINK WASTE LINE IN THE KITCHEN LOCATED AT APT 3A, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH
    Class BOpen
    Jun 15, 2026
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MORISE LOCK VESTIBULE DOOR AT PUBLIC HALL, 1st STORY
    Class BOpen
    Jun 10, 2026Apt 2D
    ABATE THE NUISANCE · MAINTENANCE
    § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HEAT ON IN SUMMER IN THE ENTIRE APARTMENT LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''WEST''
    Class BOpen
    Jun 9, 2026Apt 2D
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL AND CEILING IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''WEST''
    Class BOpenRENT IMPAIRING
    Jun 9, 2026Apt 2D
    REMOVE OBSTRUCTIONS · SEWERS AND DRAINAGE
    § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTE LINE AT WASHBASIN IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''WEST''
    Class BOpen
    May 28, 2026Apt 3B
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen
    May 28, 2026Apt 3B
    REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
    § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen
    May 28, 2026Apt 3B
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND EAST WALL IN THE BATHROOM LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Feb 12, 2026Apt 2D
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL, WEST WALL AND CEILING IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Feb 12, 2026Apt 2B
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Feb 12, 2026Apt 2D
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING AROUND WOOD COUNTER TOP IN THE KITCHEN LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Feb 12, 2026Apt 2D
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MECHANICAL VENTILATION AT CEILING IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Feb 12, 2026Apt 2B
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND EAST WALL IN THE BATHROOM LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Jan 9, 2026Apt 3A
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOCK AND ASSEMBLY IN THE ENTRANCE LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''EAST''
    Class BOpenRENT IMPAIRING
    Oct 20, 2025
    LEAKY ROOF · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING AT PUBLIC HALL, 6th STORY
    Page 3 of 8