stoop
MAP
LeaderboardAbout
Building SafetyHousing Conditions

997 ROGERS AVENUE

Brooklyn · ZIP 11249 · BIN 3000000 · Fort Greene · Last violation Aug 11, 2026 · Last complaint Aug 14, 2026

NeighborhoodFort Greene
More violations than 100% of nearby buildings
More violations than 100% of buildings and more complaints than 100% of buildings in Fort Greene. Size-normalized against residential buildings in the neighborhood for issues in the last 10 years.
ViolationsComplaints
Activity TrendsLast 5 years
A steady level of activity over time
Last 2 yrs: 938 violations · 1814 complaints
'21'26ViolationsComplaints
▼ View all activity over time
Severityⓘopen violations
656 immediately hazardous (Class C) violations still open
Class C violations include lead paint, mold, pest infestations, heat/hot water failure, and structural hazards — the most serious category.
Class Cimmediately hazardous656Class Bhazardous1629

What to watch forⓘ

  1. Hazardous violations are open, including building maintenance, heat and hot water, and fire safety.
    Worth checking · AI-assistedⓘ
    Look at baseboards, walls, and ceilings for water stains, soft spots, or visible damage. Check that the radiator or heating unit turns on and warms up when you ask the super to try it. Walk the hallway and stairwell to see if doors block any exits and if steps are intact and even.
    details ▸

    Deadlines vary by condition: immediate for heat and hot water, 14 days for self-closing doors, 21 days for lead paint, window guards, mold, and mice, cockroaches or rats, and 24 hours for everything else. They run from the date the owner is served, and mark when civil penalties can be sought in Housing Court. They are not a promise the condition is fixed by then. If the owner does not fix it, HPD can send its own contractor and bill them.

    • —Bldg maintenance — General building repair, upkeep, and maintenance related housing code violations.
    • —Heat / hot water — Lack of heat, hot water, or heating system related issues affecting tenants.
    • —
Housing Preservation & Development Violations
Total violations since 1974
11,850
224 per year avg.→ Stable in the last 2 years
Open violations
3,590
Class C (immed. haz.)ⓘ656
Class B (hazardous)ⓘ1,629
Rent-impairingⓘ134
Housing Preservation & Development Complaints
Total complaints since 2003
14,893
621 per year avg.↑ Up 41% in the last 2 years (1,814 vs 1,287 prior 2 yrs)
Complaint Resolution
No access27%Violation issued18%No violation33%Phone resolved22%Other1%(14,893)
Urgency breakdown
Last 12 mo.

Top violation categories

5 yrsAll time
Filing: Bedbugsⓘ719 violations
Maintenanceⓘ363 violations
Posting/Signageⓘ252 violations
Egressⓘ224 violations
Heat And Hot Waterⓘ113 violations
Water Supplyⓘ112 violations
Cleaningⓘ109 violations
Carbon Monoxide Detecting Devicesⓘ82 violations
Top complaint groupsⓘ
5 yrsAll time
Heat / hot waterⓘ1,074 complaints
Water & plumbingⓘ661 complaints
Mold & pestsⓘ547 complaints
Bldg maintenanceⓘ480 complaints
Electricalⓘ184 complaints
Safety & fireⓘ129 complaints
Appliancesⓘ80 complaints
Adminⓘ22 complaints
Elevatorⓘ5 complaints
Outdoor / structuralⓘ4 complaints
Hide violations ↑See complaints →

Violation log

3,590 violations · Open

All classesClass AClass BClass CClass IAllOpenClosed
ClassStatusApt
See something wrong? File a complaint with 311
Safety & fire — Blocked, unsafe, or inaccessible exits, hallways, stairs, or fire escape routes.

The violation list below shows which conditions are open and when each was cited. If one in your own apartment is still unaddressed, call 311.

  • ABCs of Housing
  • NYC HPD, Penalties and Fees
  • Lead-paint violations on record.
    Worth checking · AI-assistedⓘ
    Look for paint that is peeling, chipped, or cracked on interior walls, trim, windows, doors, and door frames.
    details ▸

    Buildings built before 1960 may still contain lead-based paint, which causes behavioral and learning problems in young children, who can swallow dust and paint chips from windowsills and floors.

    If a child under six lives with you, or spends 10 or more hours a week in your apartment, tell the owner in writing, which is what obliges them to inspect annually. Report peeling paint, and call 311 if it is not fixed or if repair work is raising dust that is not being contained.

    • ABCs of Housing
  • Detector violations on record.
    Worth checking · AI-assistedⓘ
    Locate smoke detectors on the ceiling near bedrooms and in hallways, and ask the broker whether carbon monoxide detectors are present in the unit.
    details ▸

    Responsibility is split: the owner provides, installs, and replaces the detectors, while the tenant tests them monthly and replaces the batteries. An open violation means the owner has not yet certified to HPD that the condition was fixed, so a device may still be missing or dead at move-in. A tenant reimburses the owner for a newly installed device, $25 for a smoke or carbon monoxide detector and $50 for a combined unit, and is responsible for replacing one that goes missing or is damaged during the tenancy.

    On a viewing, look for a smoke alarm within fifteen feet of the door of each room used for sleeping, on the ceiling or just below it on the wall, and a carbon monoxide alarm at any height, including one plugged into a hallway outlet. Press the test button, and check that none have been painted over. A chirping alarm usually means a low battery, which is the tenant's to replace, but detectors also sound a separate end-of-life alarm when the device itself has to be replaced by the owner.

    • ABCs of Housing
    • NYC HPD, Smoke, Carbon Monoxide, and Natural Gas Detectors
  • Open violation ages
    ▪ < 30 days1% (18)
    ▪ 30–90 days2% (57)
    ▪ 3–12 months7% (213)
    ▪ 1–3 years10% (309)
    ▪ 3+ years81% (2586)
    Prior 4 yr.
    Immed. Emergency9%7%
    Emergency60%59%
    Non-Emergency31%35%
    (1,097)
    (2,367)
    Issued
    Description
    Class BOpen2Sep 25, 2018REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
    Class BOpen2Sep 25, 2018REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INTERCOMMUNICATIONAL SYSTEM IN THE FOYER LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
    Class AOpen2Sep 25, 2018REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
    Class BOpen—Sep 17, 2018REMOVE ENCUMBRANCE · EGRESS§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF HOUSEHOLD ARTICLES AT 3RD STORY BALCONY AT BLDG FRONT .
    Class AOpen—Sep 17, 2018PROVIDE SHOE FOR DROP LADDER · FIRE EGRESS AND PROTECTION§ 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER AT FIRE ESCAPE.AT BLDG FRONT.
    Class BOpenRENT IMPAIRING—Sep 11, 2018REMOVE ILLEGAL FASTENING · EGRESS§ 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CONSISTING OF DOUBLE CYLINDER KEY OPERATED LOCK INSTALLED ON METAL DOOR AT FRONT ENTRANCE TO BUILDING , 1st STORY
    Class BOpen421Aug 13, 2018TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... APROX 18 SQ.FT CEILING IN THE BATHROOM LOCATED AT APT 421, 4th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class BOpen421Aug 13, 2018REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK THE NORTH WALL IN THE BATHROOM LOCATED AT APT 421, 4th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class BOpen421Aug 13, 2018REPAIR LEAKY FAUCETS · WATER SUPPLY§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 421, 4th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class BOpen421Aug 13, 2018ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATION§ 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 421, 4th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class AOpen3FLJun 18, 2018§ 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE ELECTRIC SWITCH COVER AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 3FL, 3rd STORY§ 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE ELECTRIC SWITCH COVER AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 3FL, 3rd STORY
    Class AOpen3FLJun 18, 2018REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE LOOSE AND DEFECTIVE REFRIGERATOR RUBBER GASKET IN THE KITCHEN LOCATED AT APT 3FL, 3rd STORY
    Class BOpen—Jun 15, 2018REPAIR · MAINTENANCE§ 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT BUILDING ENTRANCE
    Class BOpen3FLJun 15, 2018TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... 1 SQ. FT. AROUND THE BATHTUB IN THE BATHROOM LOCATED AT APT 3FL, 3rd STORY
    Class COpen1FLApr 30, 2018RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE BROKEN WINDOW GLASS PANE AT EAST WALL IN THE KITCHEN LOCATED AT APT 1FL, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
    Class COpenRENT IMPAIRING1FLApr 30, 2018INADEQUATE COLD WATER · WATER SUPPLY§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES .. IN THE ENTIRE APARTMENT LOCATED AT APT 1FL, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
    Class COpenRENT IMPAIRING1FLApr 30, 2018INADEQUATE HOT WATER SUPPLY (VOLUME) · WATER SUPPLY§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES .. IN THE ENTIRE APARTMENT LOCATED AT APT 1FL, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
    Class COpen1FLApr 30, 2018PROVIDE SUPPLY OF ELECTRICTY TO FIXTURES · ARTIFICIAL LIGHTING§ 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES .. IN THE ENTIRE APARTMENT LOCATED AT APT 1FL, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
    Class BOpen1Mar 22, 2018NO CO DETECTOR OR DETECTOR NOT OPERATIONAL · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, APARTMENT AT SOUTH
    Class BOpen—Mar 22, 2018REPAIR · MAINTENANCE§ 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING AT PUBLIC HALL, 1st STORY
    Class BOpen1Mar 22, 2018ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATION§ 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, APARTMENT AT SOUTH
    Class BOpen1Mar 22, 2018REPLACE · MAINTENANCE§ 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING STRIKING PLATE AT DOOR POST IN THE ENTRANCE LOCATED AT APT 1, 1st STORY, APARTMENT AT SOUTH
    Class BOpen1Mar 22, 2018REMOVE OBSTRUCTIONS · SEWERS AND DRAINAGE§ 27-2026 ADMIN. CODE: REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTE LINE AT SINK IN THE KITCHEN LOCATED AT APT 1, 1st STORY, APARTMENT AT SOUTH
    Class BOpen1Mar 22, 2018ABATE THE NUISANCE OF MICE · EXTERMINATION & RODENT ERADICATION§ 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, APARTMENT AT SOUTH
    Class AOpen—Feb 7, 2018POST AND MAINTAIN A NOTICE · POSTING/SIGNAGE§27-2153 ADM CODE POST AND MAINTAIN A NOTICE, WRITTEN IN ENGLISH AND IN SPANISH, ON THE BUILDING ENTRANCE DOOR OR OTHER CONSPICUOUS LOCATION IN THE BUILDING COMMON AREA, STATING THAT: (1) THE BUILDING IS IN THE ALTERNATIVE ENFORCEMENT PROGRAM, (2) THAT OCCUPANTS MAY CALL 311 OR THE AEP AT 212-863-8262 TO REPORT HOUSING MAINTENANCE COMPLAINTS, (3) THE NAME, TELEPHONE, AND ADDRESS OF THE OWNER, AND, (4) THE IDENTITY OF ANY FINANCIAL INSTITUTION THAT HOLDS A MORTGAGE ON THE PROPERTY. POST
    Class COpen2Jan 18, 2018INADEQUATE HEAT · HEAT AND HOT WATER§ 27-2029 ADMIN. CODE: PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY
    Class COpen2Jan 18, 2018INADEQUATE HOT WATER · HEAT AND HOT WATER§ 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY
    Class BOpen2Jan 18, 2018REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY
    Class COpen2Jan 9, 2018PROVIDE ADEQUATE HEAT · HEAT AND HOT WATER§ 27-2028, 2032 ADMIN.CODE: PROVIDE AN ADEQUATE SUPPLY OF HEAT FROM AN APPROVED CENTRAL HEATING SYSTEM OR AN APPROVED SYSTEM OF GAS OR ELECTRICAL HEATING IN GOOD OPERATING CONDITION FOR THE DWELLING UNIT IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, APARTMENT AT WEST
    Class COpen1FJan 2, 2018INADEQUATE HEAT · HEAT AND HOT WATER§ 27-2029 ADMIN. CODE: PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 1F, 1st STORY
    Class BOpen3RDFLDec 14, 2017REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR 'MISSING'' IN THE ENTIRE APARTMENT LOCATED AT APT 3RDFL, 3rd STORY, APARTMENT AT SOUTH
    Class BOpen3RDFLDec 14, 2017REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). 'MISSING'' IN THE ENTIRE APARTMENT LOCATED AT APT 3RDFL, 3rd STORY, APARTMENT AT SOUTH
    Class COpenRENT IMPAIRING3RDFLNov 14, 2017INADEQUATE HEAT · HEAT AND HOT WATER§ 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 3RDFL, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class COpen—Nov 14, 2017PROVIDE ACCESS TO BOILER ROOM · HEAT AND HOT WATER§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT CELLAR
    Class COpen—Nov 14, 2017POST BOILER ROOM ACCESS NOTICE · HEAT AND HOT WATER§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM , AT PUBLIC HALL, 1st STORY
    Class BOpen1RNov 13, 2017REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen1RNov 13, 2017REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE BATHROOM LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class AOpen1RNov 8, 2017REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE KITCHEN LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen1RNov 8, 2017ABATE THE NUISANCE OF MICE · EXTERMINATION & RODENT ERADICATION§ 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen1RNov 8, 2017ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATION§ 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class AOpen—Nov 6, 2017IV-1. NO MAILBOXES PRESENT · POSTING/SIGNAGE§ 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME READILY ACCESSIBLE FOR SIGNATURE, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR AT ,, AT PUBLIC HALL
    Class AOpen—Nov 6, 2017POST GAS LEAK NOTICE · POSTING/SIGNAGE§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL
    Class COpen—Oct 31, 2017POST BOILER ROOM ACCESS NOTICE · HEAT AND HOT WATER§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM , AT PUBLIC HALL, 1st STORY
    Class COpen—Oct 31, 2017PROVIDE ACCESS TO BOILER ROOM · HEAT AND HOT WATER§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM , DOOR TO CELLAR LOCKED AT CELLAR
    Class BOpen3FLROct 31, 2017REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WALLS IN THE ENTIRE APARTMENT LOCATED AT APT 3FLR, 3rd STORY
    Class BOpen—Oct 31, 2017REMOVE ACCUMULATION OR RUBBISH · CLEANING§ 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE ALL STYS AT PUBLIC HALL
    Class BOpen2Oct 2, 2017NO CO DETECTOR OR DETECTOR NOT OPERATIONAL · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 2, 1st STORY
    Class AOpen—Sep 25, 2017POST CO DETECTOR NOTICE · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL, 1st STORY
    Class AOpen—Sep 25, 2017POST REGISTRATION SIGN · ANNUAL PROPERTY REGISTRATION§ 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORY
    Class AOpen—Sep 25, 2017POST HOUSING INFORMATION GUIDE NOTICE · POSTING/SIGNAGE§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY
    Class BOpen
    Sep 25, 2018Apt 2
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
    Class BOpen
    Sep 25, 2018Apt 2
    REPAIR · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INTERCOMMUNICATIONAL SYSTEM IN THE FOYER LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
    Class AOpen
    Sep 25, 2018Apt 2
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
    Class BOpen
    Sep 17, 2018
    REMOVE ENCUMBRANCE · EGRESS
    § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF HOUSEHOLD ARTICLES AT 3RD STORY BALCONY AT BLDG FRONT .
    Class AOpen
    Sep 17, 2018
    PROVIDE SHOE FOR DROP LADDER · FIRE EGRESS AND PROTECTION
    § 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER AT FIRE ESCAPE.AT BLDG FRONT.
    Class BOpenRENT IMPAIRING
    Sep 11, 2018
    REMOVE ILLEGAL FASTENING · EGRESS
    § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CONSISTING OF DOUBLE CYLINDER KEY OPERATED LOCK INSTALLED ON METAL DOOR AT FRONT ENTRANCE TO BUILDING , 1st STORY
    Class BOpen
    Aug 13, 2018Apt 421
    TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
    § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... APROX 18 SQ.FT CEILING IN THE BATHROOM LOCATED AT APT 421, 4th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class BOpen
    Aug 13, 2018Apt 421
    REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
    § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK THE NORTH WALL IN THE BATHROOM LOCATED AT APT 421, 4th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class BOpen
    Aug 13, 2018Apt 421
    REPAIR LEAKY FAUCETS · WATER SUPPLY
    § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 421, 4th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class BOpen
    Aug 13, 2018Apt 421
    ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATION
    § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 421, 4th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class AOpen
    Jun 18, 2018Apt 3FL
    § 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE ELECTRIC SWITCH COVER AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 3FL, 3rd STORY
    § 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE ELECTRIC SWITCH COVER AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 3FL, 3rd STORY
    Class AOpen
    Jun 18, 2018Apt 3FL
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE LOOSE AND DEFECTIVE REFRIGERATOR RUBBER GASKET IN THE KITCHEN LOCATED AT APT 3FL, 3rd STORY
    Class BOpen
    Jun 15, 2018
    REPAIR · MAINTENANCE
    § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT BUILDING ENTRANCE
    Class BOpen
    Jun 15, 2018Apt 3FL
    TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
    § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... 1 SQ. FT. AROUND THE BATHTUB IN THE BATHROOM LOCATED AT APT 3FL, 3rd STORY
    Class COpen
    Apr 30, 2018Apt 1FL
    RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED
    § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE BROKEN WINDOW GLASS PANE AT EAST WALL IN THE KITCHEN LOCATED AT APT 1FL, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
    Class COpenRENT IMPAIRING
    Apr 30, 2018Apt 1FL
    INADEQUATE COLD WATER · WATER SUPPLY
    § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES .. IN THE ENTIRE APARTMENT LOCATED AT APT 1FL, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
    Class COpenRENT IMPAIRING
    Apr 30, 2018Apt 1FL
    INADEQUATE HOT WATER SUPPLY (VOLUME) · WATER SUPPLY
    § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES .. IN THE ENTIRE APARTMENT LOCATED AT APT 1FL, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
    Class COpen
    Apr 30, 2018Apt 1FL
    PROVIDE SUPPLY OF ELECTRICTY TO FIXTURES · ARTIFICIAL LIGHTING
    § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES .. IN THE ENTIRE APARTMENT LOCATED AT APT 1FL, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
    Class BOpen
    Mar 22, 2018Apt 1
    NO CO DETECTOR OR DETECTOR NOT OPERATIONAL · CARBON MONOXIDE DETECTING DEVICES
    § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, APARTMENT AT SOUTH
    Class BOpen
    Mar 22, 2018
    REPAIR · MAINTENANCE
    § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING AT PUBLIC HALL, 1st STORY
    Class BOpen
    Mar 22, 2018Apt 1
    ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATION
    § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, APARTMENT AT SOUTH
    Class BOpen
    Mar 22, 2018Apt 1
    REPLACE · MAINTENANCE
    § 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING STRIKING PLATE AT DOOR POST IN THE ENTRANCE LOCATED AT APT 1, 1st STORY, APARTMENT AT SOUTH
    Class BOpen
    Mar 22, 2018Apt 1
    REMOVE OBSTRUCTIONS · SEWERS AND DRAINAGE
    § 27-2026 ADMIN. CODE: REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTE LINE AT SINK IN THE KITCHEN LOCATED AT APT 1, 1st STORY, APARTMENT AT SOUTH
    Class BOpen
    Mar 22, 2018Apt 1
    ABATE THE NUISANCE OF MICE · EXTERMINATION & RODENT ERADICATION
    § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, APARTMENT AT SOUTH
    Class AOpen
    Feb 7, 2018
    POST AND MAINTAIN A NOTICE · POSTING/SIGNAGE
    §27-2153 ADM CODE POST AND MAINTAIN A NOTICE, WRITTEN IN ENGLISH AND IN SPANISH, ON THE BUILDING ENTRANCE DOOR OR OTHER CONSPICUOUS LOCATION IN THE BUILDING COMMON AREA, STATING THAT: (1) THE BUILDING IS IN THE ALTERNATIVE ENFORCEMENT PROGRAM, (2) THAT OCCUPANTS MAY CALL 311 OR THE AEP AT 212-863-8262 TO REPORT HOUSING MAINTENANCE COMPLAINTS, (3) THE NAME, TELEPHONE, AND ADDRESS OF THE OWNER, AND, (4) THE IDENTITY OF ANY FINANCIAL INSTITUTION THAT HOLDS A MORTGAGE ON THE PROPERTY. POST
    Class COpen
    Jan 18, 2018Apt 2
    INADEQUATE HEAT · HEAT AND HOT WATER
    § 27-2029 ADMIN. CODE: PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY
    Class COpen
    Jan 18, 2018Apt 2
    INADEQUATE HOT WATER · HEAT AND HOT WATER
    § 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY
    Class BOpen
    Jan 18, 2018Apt 2
    REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
    § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY
    Class COpen
    Jan 9, 2018Apt 2
    PROVIDE ADEQUATE HEAT · HEAT AND HOT WATER
    § 27-2028, 2032 ADMIN.CODE: PROVIDE AN ADEQUATE SUPPLY OF HEAT FROM AN APPROVED CENTRAL HEATING SYSTEM OR AN APPROVED SYSTEM OF GAS OR ELECTRICAL HEATING IN GOOD OPERATING CONDITION FOR THE DWELLING UNIT IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, APARTMENT AT WEST
    Class COpen
    Jan 2, 2018Apt 1F
    INADEQUATE HEAT · HEAT AND HOT WATER
    § 27-2029 ADMIN. CODE: PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 1F, 1st STORY
    Class BOpen
    Dec 14, 2017Apt 3RDFL
    REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
    § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR 'MISSING'' IN THE ENTIRE APARTMENT LOCATED AT APT 3RDFL, 3rd STORY, APARTMENT AT SOUTH
    Class BOpen
    Dec 14, 2017Apt 3RDFL
    REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
    § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). 'MISSING'' IN THE ENTIRE APARTMENT LOCATED AT APT 3RDFL, 3rd STORY, APARTMENT AT SOUTH
    Class COpenRENT IMPAIRING
    Nov 14, 2017Apt 3RDFL
    INADEQUATE HEAT · HEAT AND HOT WATER
    § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 3RDFL, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class COpen
    Nov 14, 2017
    PROVIDE ACCESS TO BOILER ROOM · HEAT AND HOT WATER
    § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT CELLAR
    Class COpen
    Nov 14, 2017
    POST BOILER ROOM ACCESS NOTICE · HEAT AND HOT WATER
    § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM , AT PUBLIC HALL, 1st STORY
    Class BOpen
    Nov 13, 2017Apt 1R
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Nov 13, 2017Apt 1R
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE BATHROOM LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class AOpen
    Nov 8, 2017Apt 1R
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE KITCHEN LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Nov 8, 2017Apt 1R
    ABATE THE NUISANCE OF MICE · EXTERMINATION & RODENT ERADICATION
    § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Nov 8, 2017Apt 1R
    ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATION
    § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class AOpen
    Nov 6, 2017
    IV-1. NO MAILBOXES PRESENT · POSTING/SIGNAGE
    § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME READILY ACCESSIBLE FOR SIGNATURE, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR AT ,, AT PUBLIC HALL
    Class AOpen
    Nov 6, 2017
    POST GAS LEAK NOTICE · POSTING/SIGNAGE
    § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL
    Class COpen
    Oct 31, 2017
    POST BOILER ROOM ACCESS NOTICE · HEAT AND HOT WATER
    § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM , AT PUBLIC HALL, 1st STORY
    Class COpen
    Oct 31, 2017
    PROVIDE ACCESS TO BOILER ROOM · HEAT AND HOT WATER
    § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM , DOOR TO CELLAR LOCKED AT CELLAR
    Class BOpen
    Oct 31, 2017Apt 3FLR
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WALLS IN THE ENTIRE APARTMENT LOCATED AT APT 3FLR, 3rd STORY
    Class BOpen
    Oct 31, 2017
    REMOVE ACCUMULATION OR RUBBISH · CLEANING
    § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE ALL STYS AT PUBLIC HALL
    Class BOpen
    Oct 2, 2017Apt 2
    NO CO DETECTOR OR DETECTOR NOT OPERATIONAL · CARBON MONOXIDE DETECTING DEVICES
    § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 2, 1st STORY
    Class AOpen
    Sep 25, 2017
    POST CO DETECTOR NOTICE · CARBON MONOXIDE DETECTING DEVICES
    § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL, 1st STORY
    Class AOpen
    Sep 25, 2017
    POST REGISTRATION SIGN · ANNUAL PROPERTY REGISTRATION
    § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORY
    Class AOpen
    Sep 25, 2017
    POST HOUSING INFORMATION GUIDE NOTICE · POSTING/SIGNAGE
    § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY
    Page 20 of 72