stoop
MAP
LeaderboardAbout
Building SafetyHousing Conditions

997 ROGERS AVENUE

Brooklyn · ZIP 11249 · BIN 3000000 · Fort Greene · Last violation Nov 18, 2026 · Last complaint Nov 20, 2026

NeighborhoodFort Greene
More violations than 100% of nearby buildings
More violations than 100% of buildings and more complaints than 100% of buildings in Fort Greene. Size-normalized against residential buildings in the neighborhood for issues in the last 10 years.
ViolationsComplaints
Activity TrendsLast 5 years
A steady level of activity over time
Last 2 yrs: 1095 violations · 2151 complaints
'21'26ViolationsComplaints
▼ View all activity over time
Severityⓘopen violations
685 immediately hazardous (Class C) violations still open
Class C violations include lead paint, mold, pest infestations, heat/hot water failure, and structural hazards — the most serious category.
Class Cimmediately hazardous685Class Bhazardous1676

What to watch forⓘ

  1. Hazardous violations are open, including building maintenance, heat and hot water, and fire safety.
    Worth checking · AI-assistedⓘ
    Look at baseboards, walls, and ceilings for water stains, soft spots, or visible damage. Check that the radiator or heating unit turns on and warms up when you ask the super to try it. Walk the hallway and stairwell to see if doors block any exits and if steps are intact and even.
    details ▸

    Deadlines vary by condition: immediate for heat and hot water, 14 days for self-closing doors, 21 days for lead paint, window guards, mold, and mice, cockroaches or rats, and 24 hours for everything else. They run from the date the owner is served, and mark when civil penalties can be sought in Housing Court. They are not a promise the condition is fixed by then. If the owner does not fix it, HPD can send its own contractor and bill them.

    • —Bldg maintenance — General building repair, upkeep, and maintenance related housing code violations.
    • —Heat / hot water — Lack of heat, hot water, or heating system related issues affecting tenants.
    • —
Housing Preservation & Development Violations
Total violations since 1974
12,154
229 per year avg.↑ Up 10% in the last 2 years (1,095 vs 998 prior 2 yrs)
Open violations
3,700
Class C (immed. haz.)ⓘ685
Class B (hazardous)ⓘ1,676
Rent-impairingⓘ140
Housing Preservation & Development Complaints
Total complaints since 2003
15,401
642 per year avg.↑ Up 51% in the last 2 years (2,151 vs 1,427 prior 2 yrs)
Complaint Resolution
No access27%Violation issued17%No violation33%Phone resolved22%Other1%(15,401)
Urgency breakdown
Last 12 mo.

Top violation categories

5 yrsAll time
Filing: Bedbugsⓘ723 violations
Maintenanceⓘ428 violations
Posting/Signageⓘ289 violations
Egressⓘ246 violations
Water Supplyⓘ129 violations
Heat And Hot Waterⓘ119 violations
Cleaningⓘ118 violations
Carbon Monoxide Detecting Devicesⓘ97 violations
Top complaint groupsⓘ
5 yrsAll time
Heat / hot waterⓘ1,140 complaints
Water & plumbingⓘ747 complaints
Mold & pestsⓘ636 complaints
Bldg maintenanceⓘ554 complaints
Electricalⓘ233 complaints
Safety & fireⓘ142 complaints
Appliancesⓘ88 complaints
Adminⓘ28 complaints
Elevatorⓘ6 complaints
Outdoor / structuralⓘ4 complaints
Hide violations ↑See complaints →

Violation log

8,454 violations · Close

All classesClass AClass BClass CClass IAllOpenClosed
ClassStatusApt
See something wrong? File a complaint with 311
Safety & fire — Blocked, unsafe, or inaccessible exits, hallways, stairs, or fire escape routes.

The violation list below shows which conditions are open and when each was cited. If one in your own apartment is still unaddressed, call 311.

  • ABCs of Housing
  • NYC HPD, Penalties and Fees
  • Lead-paint violations on record.
    Worth checking · AI-assistedⓘ
    Look for paint that is peeling, chipped, or cracked on interior walls, trim, windows, doors, and door frames.
    details ▸

    Buildings built before 1960 may still contain lead-based paint, which causes behavioral and learning problems in young children, who can swallow dust and paint chips from windowsills and floors.

    If a child under six lives with you, or spends 10 or more hours a week in your apartment, tell the owner in writing, which is what obliges them to inspect annually. Report peeling paint, and call 311 if it is not fixed or if repair work is raising dust that is not being contained.

    • ABCs of Housing
  • Detector violations on record.
    Worth checking · AI-assistedⓘ
    Locate smoke detectors on the ceiling near bedrooms and in hallways, and ask the broker whether carbon monoxide detectors are present in the unit.
    details ▸

    Responsibility is split: the owner provides, installs, and replaces the detectors, while the tenant tests them monthly and replaces the batteries. An open violation means the owner has not yet certified to HPD that the condition was fixed, so a device may still be missing or dead at move-in. A tenant reimburses the owner for a newly installed device, $25 for a smoke or carbon monoxide detector and $50 for a combined unit, and is responsible for replacing one that goes missing or is damaged during the tenancy.

    On a viewing, look for a smoke alarm within fifteen feet of the door of each room used for sleeping, on the ceiling or just below it on the wall, and a carbon monoxide alarm at any height, including one plugged into a hallway outlet. Press the test button, and check that none have been painted over. A chirping alarm usually means a low battery, which is the tenant's to replace, but detectors also sound a separate end-of-life alarm when the device itself has to be replaced by the owner.

    • ABCs of Housing
    • NYC HPD, Smoke, Carbon Monoxide, and Natural Gas Detectors
  • Open violation ages
    ▪ < 30 days2% (51)
    ▪ 30–90 days5% (164)
    ▪ 3–12 months6% (185)
    ▪ 1–3 years9% (304)
    ▪ 3+ years79% (2595)
    Prior 4 yr.
    Immed. Emergency11%7%
    Emergency56%59%
    Non-Emergency33%34%
    (1,409)
    (2,479)
    Issued
    Description
    Class AClosed—Jun 11, 2008REPAIR PLASTER · MAINTENANCED26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CLG & WALLS PUB HALL ALL STYS.
    Class BClosed3Jun 11, 2008REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICESSECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE 3 STY APT 3 TORRES. LOCATED AT APT 3
    Class AClosed—Jun 11, 2008IV-1. MAILBOXES PRESENT · POSTING/SIGNAGESECTION 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR FRAME MISSING.
    Class AClosed—Jun 11, 2008REPAIR · MAINTENANCED26-10.01 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BRICK CHIMNEY ROOF FRONT.
    Class BClosedRENT IMPAIRING—Jun 11, 2008MAKE GATE IN FENCE OPENABLE · EGRESSD26-10.01, 10.05 ADM CODE FIRE EGRESS DEFECTIVE. RESTORE EGRESS BY REMOVING LOCKING DEVICE AND ARRANGE TO OPEN READILY THE GATE IN FENCE AT LOT LINE EAST COURT.
    Class AClosed—Jun 11, 2008FILE CERTIFICATION SMOKE DETECTOR - DO NOT USE, RULE REVISED · RETIREDD26-20.08,20.09 ADM CODE FILE CERTIFICATION OF SATISFACTORY INSTALLATION OF SMOKE DETECTING DEVICE IN ACCORDANCE WITH H.P.D. RULES AND REGULATIONS.
    Class AClosed—Jun 11, 2008REPAIR · MAINTENANCED26-10.01 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE EXTERIOR SIDING 1 STY TO ROOF AT FRONT.
    Class BClosed1Jun 11, 2008NO SMOKE DETECTOR OR SMOKE DECTOR NOT OPERATIONAL · SMOKE DETECTING DEVICESSECTION 27-2045, 2046 ADM CODE PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING 1 STY WEST APT 1. , SECTION '' ''
    Class AClosed—Jun 11, 2008REPAIR RAIN LEADER · SEWERS AND DRAINAGED26-16.03 ADM CODE REPAIR THE BROKEN OR DEFECTIVE RAIN LEADER 1 TO 2 STY FRONT WEST OF BLDG.
    Class BClosed—Jun 11, 2008ABATE THE NUISANCE · MAINTENANCED26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CAR PARKED UNDER DROP LADDER AT EAST COURT.
    Class AClosed—Jun 11, 2008POST SMOKE DETECTOR NOTICE · POSTING/SIGNAGED26-20.08 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING.
    Class BClosed—Jun 11, 2008REMOVE ENCUMBRANCE · EGRESSD26-10.01, 10.05 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES 3 STY BALCONY EAST.
    Class BClosed—Jun 11, 2008REPAIR PLASTER · MAINTENANCE§ 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR WALLS AND CEILING AT SOUTH WEST ROOM 2ND STORY APT. #2.
    Class CClosedRENT IMPAIRING—Jun 11, 2008REMOVE RODENT · EXTERMINATION & RODENT ERADICATIONSECTION 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF RODENTS RATS CELLAR THRU OUT.
    Class CClosed—Jun 11, 2008REMOVE OBSTUCTION FROM WATER CLOSET · SEWERS AND DRAINAGE§ 27-2026 ADMIN. CODE: REMOVE ALL OBSTRUCTIONS FROM WATER CLOSET BATHROOM 2ND STY. APT.
    Class BClosed1Jun 11, 2008ABATE THE NUISANCE · MAINTENANCESECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRICAL WIRE CEILING 1 STY APT 1 FRONT ROOM. LOCATED AT APT 1
    Class BClosed—Jun 11, 2008INADEQUATE HOT WATER · HEAT AND HOT WATER§ 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES KITCHEN & BATHROOM FIXTURES 2ND STY. APT.
    Class BClosed—Jun 11, 2008§ 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE WALL SWITCH BATHROOM 2ND STY. APT.§ 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE WALL SWITCH BATHROOM 2ND STY. APT.
    Class AClosed—Jun 11, 2008NO PEEP HOLE · PROTECTIVE DEVICES AND FIRE PROTECTION§ 27-2041 ADMIN. CODE: PROVIDE A PEEP HOLE IN ENTRANCE DOOR OF THE DWELLING UNIT SO LOCATED AS TO PERMIT A PERSON INSIDE THE DWELLING UNIT TO VIEW ANY PERSON OUTSIDE ENTRANCE DOOR TO 2ND STY. APT.
    Class CClosed—Jun 11, 2008INADEQUATE HOT WATER · HEAT AND HOT WATER§ 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES KITCHEN & BATHROOM 2 STY. APT. 1.
    Class CClosed—Jun 11, 2008INADEQUATE HOT WATER · HEAT AND HOT WATER§ 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES 2 STY. APT. 3.
    Class BClosed—Jun 11, 2008DISCONTINUE ROOMS AT BSMT OR OBTAIN C/O · OCCUPANY OF BASEMENT AND CELLARS§ 27-2087 ADM CODE - DISCONTINUE USE OF ROOMS FOR LIVING PURPOSES OR OBTAIN A CERTIFICATE OF OCCUPANCY BASEMENT STY. THROUGHOUT.
    Class AClosed—Jun 11, 2008NO PEEP HOLE · PROTECTIVE DEVICES AND FIRE PROTECTION§ 27-2041 ADMIN. CODE: PROVIDE A PEEP HOLE IN ENTRANCE DOOR OF THE DWELLING UNIT SO LOCATED AS TO PERMIT A PERSON INSIDE THE DWELLING UNIT TO VIEW ANY PERSON OUTSIDE ENTRANCE DOOR FRONT ENTRANCE DOOR 3RD STY. APT.
    Class BClosed—Jun 11, 2008REPAIR · MAINTENANCE§ 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK & JAMB TO FRONT ENTRANCE DOOR 3RD STY. APT.
    Class CClosed—Jun 11, 2008INADEQUATE HOT WATER · HEAT AND HOT WATER§ 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES KITCHEN & BATHROOM 2ND STY. APT. 2.
    Class CClosed—Jun 11, 2008ABATE THE NUISANCE · MAINTENANCE§ 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF DOUBLE CYLINDER KEY OPERATED LOCK AT ENTRANCE DOOR 3RD STY. APT.
    Class CClosed—Jun 11, 2008INADEQUATE HOT WATER · HEAT AND HOT WATER§ 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES BATHROOM & KITCHEN 3RD STY. APT. 3.
    Class CClosed—Jun 11, 2008INADEQUATE HOT WATER · HEAT AND HOT WATER§ 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES KITCHEN & BATHROOM 2ND STY. APT. 2.
    Class AClosed1RJun 11, 2008NO PEEP HOLE · PROTECTIVE DEVICES AND FIRE PROTECTIOND26-20.01 ADM CODE PROVIDE A PEEP HOLE IN ENTRANCE DOOR OF THE DWELLING UNIT SO LOCATED SO AS TO PERMIT A PERSON INSIDE THE DWELLING TO VIEW ANY PERSON OUTSIDE ENTRANCE DOOR 2 STY APT 1R. LOCATED AT APT 1R
    Class BClosed—Jun 11, 2008INADEQUATE LIGHTING IN YARD OR COURT · ARTIFICIAL LIGHTINGD26-19.07 ADM CODE INSTALL AND MAINTAIN SUFFICIENT LIGHT OR LIGHTS OF AT LEAST 40 WATTS INCANDESCENT OR EQUIVALENT EACH, TO LIGHT ADEQUATELY FROM SUNSET TO SUNRISE THE WEST COURT YARD NIGHT INSPECTION.
    Class CClosed—Jun 11, 2008INADEQUATE HOT WATER · HEAT AND HOT WATER§ 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES 3RD STY. APT.
    Class AClosed1LJun 11, 2008NO PEEP HOLE · PROTECTIVE DEVICES AND FIRE PROTECTIOND26-20.01 ADM CODE PROVIDE A PEEP HOLE IN ENTRANCE DOOR OF THE DWELLING UNIT SO LOCATED SO AS TO PERMIT A PERSON INSIDE THE DWELLING TO VIEW ANY PERSON OUTSIDE ENTRANCE DOOR 2 STY APT 1L. LOCATED AT APT 1L
    Class CClosed—Jun 11, 2008REPLACE · MAINTENANCE§ 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING STEAM RADIATOR AT SOUTHWEST ROOM 2ND STY. NORTHEAST APT. 2.
    Class CClosed—Jun 11, 2008INADEQUATE COLD WATER · WATER SUPPLY§ 27-2024 ADMIN. CODE: PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT KITCHEN AND BATHROOM 2ND STORY APT. #2.
    Class BClosedRENT IMPAIRING—Jun 11, 2008REMOVE ENCUMBRANCES · EGRESSD26-10.01, 10.05 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ARTICLES 3 STY PUB HALL.
    Class BClosed—Jun 10, 2008ABATE THE NUISANCE · MAINTENANCED26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF COCKLOFT AT SCUTTLE OPENING COVERED WITH ONE EIGHTH INCH WOOD PANELING 3 STY PUB HALL.
    Class CClosed—Jun 10, 2008POST BOILER ROOM ACCESS NOTICE · HEAT AND HOT WATERD26-17.10 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDING'S HEATING SYSTEM 1 STY PUB HALL & BOILER ROOM DOOR.
    Class AClosed—Jun 10, 2008POST FLOOR SIGN · POSTING/SIGNAGED26-21.03 ADM CODE PAINT OR POST A SIGN INDICATING FLOORS ON WALLS AT OR NEAR STAIRS ALL STYS PUB HALLS.
    Class AClosed—Jun 10, 2008POST SMOKE DETECTOR NOTICE · POSTING/SIGNAGED26-20.08 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING.
    Class AClosed—Jun 10, 2008REPLACE · MAINTENANCED26-10.01 ADM CODE REPLACE WITH NEW THE MISSING DOORKNOB OF VESTIBULE TO 1 STY PUB HALL DOOR.
    Class AClosed—Jun 10, 2008RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIREDD26-10.01 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE CERAMIC WALL TILES OF VESTIBULE.
    Class BClosed—Jun 10, 2008PROVIDE LIGHT - Not Less that 60 Watt incadescent · ARTIFICIAL LIGHTINGD26-19.05 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION ALL STYS PUB HALL.
    Class BClosed—Jun 10, 2008REPAIR PLASTER · MAINTENANCED26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING 3 STY PUB HALL.
    Class AClosed—Jun 10, 2008FILE CERTIFICATION SMOKE DETECTOR - DO NOT USE, RULE REVISED · RETIREDD26-20.08,20.09 ADM CODE FILE CERTIFICATION OF SATISFACTORY INSTALLATION OF SMOKE DETECTING DEVICE IN ACCORDANCE WITH H.P.D. RULES AND REGULATIONS.
    Class AClosed—Jun 10, 2008REPAIR RAIN LEADER · SEWERS AND DRAINAGED26-16.03 ADM CODE REPAIR THE BROKEN OR DEFECTIVE RAIN LEADER REAR YARD.
    Class AClosed—Jun 10, 2008PROVIDE A GUTTER · SEWERS AND DRAINAGED26-16.03 ADM CODE PROVIDE A GUTTER, PROPERLY CONNECTED TO DRAINAGE SYSTEM, FOR PROPER DRAINAGE ROOF REAR EXTENSION.
    Class BClosed—Jun 10, 2008REPAIR WITH SIMILAR MATERIAL · MAINTENANCED26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE HOLE IN PLASTERED WALL OF COCKLOFT AT SCUTTLE.
    Class AClosed—Jun 10, 2008REPAIR WITH SIMILAR MATERIAL · MAINTENANCED26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SHEET ROCK CEILING CELLAR THROUGHOUT R 43.
    Class AClosed—Jun 10, 2008REPAIR WITH SIMILAR MATERIAL · MAINTENANCED26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE METAL CEILING IN BOILER ROOM CELLAR AT REAR R 44.
    Class BClosed—Jun 10, 2008REMOVE ACCUMULATION OR RUBBISH · CLEANINGD26-11.01, 11.03, 11.05 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE REAR YARD.
    Class AClosed
    Jun 11, 2008
    REPAIR PLASTER · MAINTENANCE
    D26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CLG & WALLS PUB HALL ALL STYS.
    Class BClosed
    Jun 11, 2008Apt 3
    REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
    SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE 3 STY APT 3 TORRES. LOCATED AT APT 3
    Class AClosed
    Jun 11, 2008
    IV-1. MAILBOXES PRESENT · POSTING/SIGNAGE
    SECTION 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR FRAME MISSING.
    Class AClosed
    Jun 11, 2008
    REPAIR · MAINTENANCE
    D26-10.01 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BRICK CHIMNEY ROOF FRONT.
    Class BClosedRENT IMPAIRING
    Jun 11, 2008
    MAKE GATE IN FENCE OPENABLE · EGRESS
    D26-10.01, 10.05 ADM CODE FIRE EGRESS DEFECTIVE. RESTORE EGRESS BY REMOVING LOCKING DEVICE AND ARRANGE TO OPEN READILY THE GATE IN FENCE AT LOT LINE EAST COURT.
    Class AClosed
    Jun 11, 2008
    FILE CERTIFICATION SMOKE DETECTOR - DO NOT USE, RULE REVISED · RETIRED
    D26-20.08,20.09 ADM CODE FILE CERTIFICATION OF SATISFACTORY INSTALLATION OF SMOKE DETECTING DEVICE IN ACCORDANCE WITH H.P.D. RULES AND REGULATIONS.
    Class AClosed
    Jun 11, 2008
    REPAIR · MAINTENANCE
    D26-10.01 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE EXTERIOR SIDING 1 STY TO ROOF AT FRONT.
    Class BClosed
    Jun 11, 2008Apt 1
    NO SMOKE DETECTOR OR SMOKE DECTOR NOT OPERATIONAL · SMOKE DETECTING DEVICES
    SECTION 27-2045, 2046 ADM CODE PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING 1 STY WEST APT 1. , SECTION '' ''
    Class AClosed
    Jun 11, 2008
    REPAIR RAIN LEADER · SEWERS AND DRAINAGE
    D26-16.03 ADM CODE REPAIR THE BROKEN OR DEFECTIVE RAIN LEADER 1 TO 2 STY FRONT WEST OF BLDG.
    Class BClosed
    Jun 11, 2008
    ABATE THE NUISANCE · MAINTENANCE
    D26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CAR PARKED UNDER DROP LADDER AT EAST COURT.
    Class AClosed
    Jun 11, 2008
    POST SMOKE DETECTOR NOTICE · POSTING/SIGNAGE
    D26-20.08 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING.
    Class BClosed
    Jun 11, 2008
    REMOVE ENCUMBRANCE · EGRESS
    D26-10.01, 10.05 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES 3 STY BALCONY EAST.
    Class BClosed
    Jun 11, 2008
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR WALLS AND CEILING AT SOUTH WEST ROOM 2ND STORY APT. #2.
    Class CClosedRENT IMPAIRING
    Jun 11, 2008
    REMOVE RODENT · EXTERMINATION & RODENT ERADICATION
    SECTION 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF RODENTS RATS CELLAR THRU OUT.
    Class CClosed
    Jun 11, 2008
    REMOVE OBSTUCTION FROM WATER CLOSET · SEWERS AND DRAINAGE
    § 27-2026 ADMIN. CODE: REMOVE ALL OBSTRUCTIONS FROM WATER CLOSET BATHROOM 2ND STY. APT.
    Class BClosed
    Jun 11, 2008Apt 1
    ABATE THE NUISANCE · MAINTENANCE
    SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRICAL WIRE CEILING 1 STY APT 1 FRONT ROOM. LOCATED AT APT 1
    Class BClosed
    Jun 11, 2008
    INADEQUATE HOT WATER · HEAT AND HOT WATER
    § 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES KITCHEN & BATHROOM FIXTURES 2ND STY. APT.
    Class BClosed
    Jun 11, 2008
    § 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE WALL SWITCH BATHROOM 2ND STY. APT.
    § 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE WALL SWITCH BATHROOM 2ND STY. APT.
    Class AClosed
    Jun 11, 2008
    NO PEEP HOLE · PROTECTIVE DEVICES AND FIRE PROTECTION
    § 27-2041 ADMIN. CODE: PROVIDE A PEEP HOLE IN ENTRANCE DOOR OF THE DWELLING UNIT SO LOCATED AS TO PERMIT A PERSON INSIDE THE DWELLING UNIT TO VIEW ANY PERSON OUTSIDE ENTRANCE DOOR TO 2ND STY. APT.
    Class CClosed
    Jun 11, 2008
    INADEQUATE HOT WATER · HEAT AND HOT WATER
    § 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES KITCHEN & BATHROOM 2 STY. APT. 1.
    Class CClosed
    Jun 11, 2008
    INADEQUATE HOT WATER · HEAT AND HOT WATER
    § 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES 2 STY. APT. 3.
    Class BClosed
    Jun 11, 2008
    DISCONTINUE ROOMS AT BSMT OR OBTAIN C/O · OCCUPANY OF BASEMENT AND CELLARS
    § 27-2087 ADM CODE - DISCONTINUE USE OF ROOMS FOR LIVING PURPOSES OR OBTAIN A CERTIFICATE OF OCCUPANCY BASEMENT STY. THROUGHOUT.
    Class AClosed
    Jun 11, 2008
    NO PEEP HOLE · PROTECTIVE DEVICES AND FIRE PROTECTION
    § 27-2041 ADMIN. CODE: PROVIDE A PEEP HOLE IN ENTRANCE DOOR OF THE DWELLING UNIT SO LOCATED AS TO PERMIT A PERSON INSIDE THE DWELLING UNIT TO VIEW ANY PERSON OUTSIDE ENTRANCE DOOR FRONT ENTRANCE DOOR 3RD STY. APT.
    Class BClosed
    Jun 11, 2008
    REPAIR · MAINTENANCE
    § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK & JAMB TO FRONT ENTRANCE DOOR 3RD STY. APT.
    Class CClosed
    Jun 11, 2008
    INADEQUATE HOT WATER · HEAT AND HOT WATER
    § 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES KITCHEN & BATHROOM 2ND STY. APT. 2.
    Class CClosed
    Jun 11, 2008
    ABATE THE NUISANCE · MAINTENANCE
    § 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF DOUBLE CYLINDER KEY OPERATED LOCK AT ENTRANCE DOOR 3RD STY. APT.
    Class CClosed
    Jun 11, 2008
    INADEQUATE HOT WATER · HEAT AND HOT WATER
    § 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES BATHROOM & KITCHEN 3RD STY. APT. 3.
    Class CClosed
    Jun 11, 2008
    INADEQUATE HOT WATER · HEAT AND HOT WATER
    § 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES KITCHEN & BATHROOM 2ND STY. APT. 2.
    Class AClosed
    Jun 11, 2008Apt 1R
    NO PEEP HOLE · PROTECTIVE DEVICES AND FIRE PROTECTION
    D26-20.01 ADM CODE PROVIDE A PEEP HOLE IN ENTRANCE DOOR OF THE DWELLING UNIT SO LOCATED SO AS TO PERMIT A PERSON INSIDE THE DWELLING TO VIEW ANY PERSON OUTSIDE ENTRANCE DOOR 2 STY APT 1R. LOCATED AT APT 1R
    Class BClosed
    Jun 11, 2008
    INADEQUATE LIGHTING IN YARD OR COURT · ARTIFICIAL LIGHTING
    D26-19.07 ADM CODE INSTALL AND MAINTAIN SUFFICIENT LIGHT OR LIGHTS OF AT LEAST 40 WATTS INCANDESCENT OR EQUIVALENT EACH, TO LIGHT ADEQUATELY FROM SUNSET TO SUNRISE THE WEST COURT YARD NIGHT INSPECTION.
    Class CClosed
    Jun 11, 2008
    INADEQUATE HOT WATER · HEAT AND HOT WATER
    § 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES 3RD STY. APT.
    Class AClosed
    Jun 11, 2008Apt 1L
    NO PEEP HOLE · PROTECTIVE DEVICES AND FIRE PROTECTION
    D26-20.01 ADM CODE PROVIDE A PEEP HOLE IN ENTRANCE DOOR OF THE DWELLING UNIT SO LOCATED SO AS TO PERMIT A PERSON INSIDE THE DWELLING TO VIEW ANY PERSON OUTSIDE ENTRANCE DOOR 2 STY APT 1L. LOCATED AT APT 1L
    Class CClosed
    Jun 11, 2008
    REPLACE · MAINTENANCE
    § 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING STEAM RADIATOR AT SOUTHWEST ROOM 2ND STY. NORTHEAST APT. 2.
    Class CClosed
    Jun 11, 2008
    INADEQUATE COLD WATER · WATER SUPPLY
    § 27-2024 ADMIN. CODE: PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT KITCHEN AND BATHROOM 2ND STORY APT. #2.
    Class BClosedRENT IMPAIRING
    Jun 11, 2008
    REMOVE ENCUMBRANCES · EGRESS
    D26-10.01, 10.05 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ARTICLES 3 STY PUB HALL.
    Class BClosed
    Jun 10, 2008
    ABATE THE NUISANCE · MAINTENANCE
    D26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF COCKLOFT AT SCUTTLE OPENING COVERED WITH ONE EIGHTH INCH WOOD PANELING 3 STY PUB HALL.
    Class CClosed
    Jun 10, 2008
    POST BOILER ROOM ACCESS NOTICE · HEAT AND HOT WATER
    D26-17.10 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDING'S HEATING SYSTEM 1 STY PUB HALL & BOILER ROOM DOOR.
    Class AClosed
    Jun 10, 2008
    POST FLOOR SIGN · POSTING/SIGNAGE
    D26-21.03 ADM CODE PAINT OR POST A SIGN INDICATING FLOORS ON WALLS AT OR NEAR STAIRS ALL STYS PUB HALLS.
    Class AClosed
    Jun 10, 2008
    POST SMOKE DETECTOR NOTICE · POSTING/SIGNAGE
    D26-20.08 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING.
    Class AClosed
    Jun 10, 2008
    REPLACE · MAINTENANCE
    D26-10.01 ADM CODE REPLACE WITH NEW THE MISSING DOORKNOB OF VESTIBULE TO 1 STY PUB HALL DOOR.
    Class AClosed
    Jun 10, 2008
    RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED
    D26-10.01 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE CERAMIC WALL TILES OF VESTIBULE.
    Class BClosed
    Jun 10, 2008
    PROVIDE LIGHT - Not Less that 60 Watt incadescent · ARTIFICIAL LIGHTING
    D26-19.05 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION ALL STYS PUB HALL.
    Class BClosed
    Jun 10, 2008
    REPAIR PLASTER · MAINTENANCE
    D26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING 3 STY PUB HALL.
    Class AClosed
    Jun 10, 2008
    FILE CERTIFICATION SMOKE DETECTOR - DO NOT USE, RULE REVISED · RETIRED
    D26-20.08,20.09 ADM CODE FILE CERTIFICATION OF SATISFACTORY INSTALLATION OF SMOKE DETECTING DEVICE IN ACCORDANCE WITH H.P.D. RULES AND REGULATIONS.
    Class AClosed
    Jun 10, 2008
    REPAIR RAIN LEADER · SEWERS AND DRAINAGE
    D26-16.03 ADM CODE REPAIR THE BROKEN OR DEFECTIVE RAIN LEADER REAR YARD.
    Class AClosed
    Jun 10, 2008
    PROVIDE A GUTTER · SEWERS AND DRAINAGE
    D26-16.03 ADM CODE PROVIDE A GUTTER, PROPERLY CONNECTED TO DRAINAGE SYSTEM, FOR PROPER DRAINAGE ROOF REAR EXTENSION.
    Class BClosed
    Jun 10, 2008
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    D26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE HOLE IN PLASTERED WALL OF COCKLOFT AT SCUTTLE.
    Class AClosed
    Jun 10, 2008
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    D26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SHEET ROCK CEILING CELLAR THROUGHOUT R 43.
    Class AClosed
    Jun 10, 2008
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    D26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE METAL CEILING IN BOILER ROOM CELLAR AT REAR R 44.
    Class BClosed
    Jun 10, 2008
    REMOVE ACCUMULATION OR RUBBISH · CLEANING
    D26-11.01, 11.03, 11.05 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE REAR YARD.
    Page 101 of 170