stoop
MAP
LeaderboardAbout
Building SafetyHousing Conditions

488 EAST 163 STREET

Bronx · ZIP 10451 · BIN 2116644 · Morrisania · Last violation Nov 12, 2026 · Last complaint Nov 12, 2026

NeighborhoodMorrisania
Above-average violations for the neighborhood
More violations than 69% of buildings and more complaints than 84% of buildings in Morrisania. Size-normalized against residential buildings in the neighborhood for issues in the last 10 years.
ViolationsComplaints
Activity TrendsLast 5 years
More activity recently than in past years
Last 2 yrs: 248 violations · 508 complaints
'21'26ViolationsComplaints
▼ View all activity over time
Severityⓘopen violations
41 immediately hazardous (Class C) violations still open
Class C violations include lead paint, mold, pest infestations, heat/hot water failure, and structural hazards — the most serious category.
Class Cimmediately hazardous41Class Bhazardous76

What to watch forⓘ

  1. Hazardous violations are open, including mold and pests, building maintenance, and fire safety.
    Worth checking · AI-assistedⓘ
    Look in corners, under sinks, and behind appliances for droppings, dead insects, or signs of active infestation; check walls and ceilings for mold, water stains, or discoloration. Open cabinets, closets, and the area under the sink to look for soft spots, rot, or loose trim in the wood. Try the doors to stairwells and fire escapes—they should open easily and have clear, unobstructed paths.
    details ▸

    Deadlines vary by condition: immediate for heat and hot water, 14 days for self-closing doors, 21 days for lead paint, window guards, mold, and mice, cockroaches or rats, and 24 hours for everything else. They run from the date the owner is served, and mark when civil penalties can be sought in Housing Court. They are not a promise the condition is fixed by then. If the owner does not fix it, HPD can send its own contractor and bill them.

    • —Mold & pests — Rodent, cockroach, bedbug, or other pest infestation and extermination related issues.
    • —Bldg maintenance — General building repair, upkeep, and maintenance related housing code violations.
Housing Preservation & Development Violations
Total violations since 2011
458
29 per year avg.↑ Up 71% in the last 2 years (248 vs 145 prior 2 yrs)
Open violations
137
Class C (immed. haz.)ⓘ41
Class B (hazardous)ⓘ76
Rent-impairingⓘ14
Housing Preservation & Development Complaints
Total complaints since 2010
1,134
67 per year avg.↑ Up 107% in the last 2 years (508 vs 246 prior 2 yrs)
Complaint Resolution
No access13%Violation issued14%No violation25%Phone resolved38%Other10%(1,134)
Urgency breakdown
Last 12 mo.

Top violation categories

5 yrsAll time
Maintenanceⓘ136 violations
Egressⓘ62 violations
Extermination & Rodent Eradicationⓘ54 violations
Water Supplyⓘ30 violations
Carbon Monoxide Detecting Devicesⓘ19 violations
Smoke Detecting Devicesⓘ19 violations
Cleaningⓘ19 violations
Paintingⓘ18 violations
Top complaint groupsⓘ
5 yrsAll time
Heat / hot waterⓘ225 complaints
Water & plumbingⓘ155 complaints
Mold & pestsⓘ142 complaints
Bldg maintenanceⓘ100 complaints
Electricalⓘ79 complaints
Safety & fireⓘ26 complaints
Appliancesⓘ12 complaints
Outdoor / structuralⓘ2 complaints
See violations →Hide complaints ↑

Complaint log

1,134 complaints

All categoriesHEAT/HOT WATERUNSANITARY CONDITIONPLUMBINGELECTRICHEATINGAllOpenClosed
Type
See something wrong? File a complaint with 311
—
Safety & fire — Blocked, unsafe, or inaccessible exits, hallways, stairs, or fire escape routes.

The violation list below shows which conditions are open and when each was cited. If one in your own apartment is still unaddressed, call 311.

  • ABCs of Housing
  • NYC HPD, Penalties and Fees
  • Heat or hot water problems reported in the last five years.
    Worth checking · AI-assistedⓘ
    Turn on a faucet in the kitchen and bathroom and feel whether hot water arrives, and check radiators or baseboards for warmth when the heat is on.
    details ▸

    Heat is required October 1 through May 31: at least 68°F from 6am to 10pm when it is below 55°F outside, and 62°F overnight whatever the temperature outside. Hot water must be at least 120°F, 24 hours a day, all year.

    If your apartment is colder than that, file a complaint with 311 and keep the service request number so you can track it. Never use a gas oven or range for heat, which can produce dangerous levels of carbon monoxide.

    • ABCs of Housing
  • Detector violations on record.
    Worth checking · AI-assistedⓘ
    Look at the walls near the smoke detector and ask the person showing the apartment: "When was this detector last tested?"
    details ▸

    Responsibility is split: the owner provides, installs, and replaces the detectors, while the tenant tests them monthly and replaces the batteries. An open violation means the owner has not yet certified to HPD that the condition was fixed, so a device may still be missing or dead at move-in. A tenant reimburses the owner for a newly installed device, $25 for a smoke or carbon monoxide detector and $50 for a combined unit, and is responsible for replacing one that goes missing or is damaged during the tenancy.

    On a viewing, look for a smoke alarm within fifteen feet of the door of each room used for sleeping, on the ceiling or just below it on the wall, and a carbon monoxide alarm at any height, including one plugged into a hallway outlet. Press the test button, and check that none have been painted over. A chirping alarm usually means a low battery, which is the tenant's to replace, but detectors also sound a separate end-of-life alarm when the device itself has to be replaced by the owner.

    • ABCs of Housing
    • NYC HPD, Smoke, Carbon Monoxide, and Natural Gas Detectors
  • Open violation ages
    ▪ < 30 days14% (19)
    ▪ 30–90 days27% (37)
    ▪ 3–12 months42% (57)
    ▪ 1–3 years18% (24)
    Prior 4 yr.
    Immed. Emergency9%8%
    Emergency53%61%
    Non-Emergency38%30%
    (353)
    (430)
    Status
    Apt
    Received
    Category
    EmergencyClosedBLDGDec 2, 2024HEAT/HOT WATER · ENTIRE BUILDINGThe Department of Housing Preservation and Development was not able to gain access to your apartment or others in the building to inspect for a lack of heat or hot water. The complaint has been closed. If the condition still exists, please file a new complaint.
    EmergencyClosedBLDGNov 27, 2024HEAT/HOT WATER · ENTIRE BUILDINGThe Department of Housing Preservation and Development was not able to gain access to your apartment or others in the building to inspect for a lack of heat or hot water. The complaint has been closed. If the condition still exists, please file a new complaint.
    EmergencyClosed9GNov 23, 2024PLUMBING · WATER SUPPLYHPD attempted to conduct an inspection in response to this complaint, but was unable to complete the inspection. Please submit a new service request with 311 if the condition still exists. For more information on the reason why HPD was unable to inspect, contact HPD at the Tenant Information Messaging Service at 212-863-4951.
    Non-emergencyClosedBLDGNov 23, 2024PLUMBING · WATER SUPPLYMore than one complaint was received for this building-wide condition. This complaint status is for the initial complaint.The Department of Housing Preservation and Development contacted a tenant in the building and verified that the following conditions were corrected. The complaint has been closed. If the condition still exists, please file a new complaint.
    Non-emergencyClosed10HNov 23, 2024PLUMBING · WATER SUPPLYMore than one complaint was received for this building-wide condition. This complaint status is for the initial complaint.HPD called the telephone number on file for this complaint. Someone at that number indicated that the condition was corrected. The complaint has been closed. Please submit a new service request with 311 if the condition still exists.
    Non-emergencyClosedBLDGNov 23, 2024PLUMBING · WATER SUPPLYThe Department of Housing Preservation and Development contacted a tenant in the building and verified that the following conditions were corrected. The complaint has been closed. If the condition still exists, please file a new complaint.
    Non-emergencyClosedNANov 19, 2024UNSANITARY CONDITION · GARBAGE/RECYCLING STORAGEHPD conducted an inspection of this complaint. The conditions observed by the inspector did not violate the housing laws enforced by HPD. The complaint has been closed.
    EmergencyClosedNANov 19, 2024DOOR/WINDOW · DOORHPD conducted an inspection of this complaint. The conditions observed by the inspector did not violate the housing laws enforced by HPD. The complaint has been closed.
    Non-emergencyClosed5KOct 22, 2024GENERAL · CABINETAn HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
    Non-emergencyClosed5KOct 22, 2024PAINT/PLASTER · WALLAn HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
    Non-emergencyClosed9GOct 18, 2024GENERAL · CABINETHPD conducted an inspection of this complaint. The conditions observed by the inspector did not violate the housing laws enforced by HPD. The complaint has been closed.
    EmergencyClosed9GOct 18, 2024DOOR/WINDOW · DOORHPD inspected this condition so the complaint has been closed. Violations were issued. The law provides the property owner time to correct the condition(s). Violation descriptions and the dates for the property owner to correct any violations are available at HPDONLINE. If the owner has not corrected the condition by the date provided, you may wish to bring a case in housing court seeking the correction of these conditions.To find out more about how to start a housing court case, visit HPD's webpage on Housing Court (https://www.nyc.gov/site/hpd/services-and-information/housing-court.page).
    EmergencyClosed9GOct 18, 2024PLUMBING · BASIN/SINKHPD conducted an inspection of this complaint. The conditions observed by the inspector did not violate the housing laws enforced by HPD. The complaint has been closed.
    EmergencyClosed5KOct 14, 2024HEAT/HOT WATER · APARTMENT ONLYHPD called the telephone number on file for this complaint. Someone at that number indicated that the condition was corrected. The complaint has been closed. Please submit a new service request with 311 if the condition still exists.
    Non-emergencyClosed5KOct 9, 2024PLUMBING · WATER SUPPLYHPD attempted to conduct an inspection in response to this complaint, but was unable to complete the inspection. Please submit a new service request with 311 if the condition still exists. For more information on the reason why HPD was unable to inspect, contact HPD at the Tenant Information Messaging Service at 212-863-4951.
    Non-emergencyClosed5KOct 9, 2024ELEVATOR · MAINTENANCEHPD conducted an inspection of this complaint. The conditions observed by the inspector did not violate the housing laws enforced by HPD. The complaint has been closed.
    EmergencyClosed5KOct 9, 2024UNSANITARY CONDITION · MOLDHPD attempted to conduct an inspection in response to this complaint, but was unable to complete the inspection. Please submit a new service request with 311 if the condition still exists. For more information on the reason why HPD was unable to inspect, contact HPD at the Tenant Information Messaging Service at 212-863-4951.
    EmergencyClosed5KOct 9, 2024SAFETY · CARBON MONOXIDE DETECTORHPD attempted to conduct an inspection in response to this complaint, but was unable to complete the inspection. Please submit a new service request with 311 if the condition still exists. For more information on the reason why HPD was unable to inspect, contact HPD at the Tenant Information Messaging Service at 212-863-4951.
    EmergencyClosed5KOct 9, 2024SAFETY · SMOKE DETECTORHPD attempted to conduct an inspection in response to this complaint, but was unable to complete the inspection. Please submit a new service request with 311 if the condition still exists. For more information on the reason why HPD was unable to inspect, contact HPD at the Tenant Information Messaging Service at 212-863-4951.
    EmergencyClosed5KOct 9, 2024DOOR/WINDOW · DOORHPD attempted to conduct an inspection in response to this complaint, but was unable to complete the inspection. Please submit a new service request with 311 if the condition still exists. For more information on the reason why HPD was unable to inspect, contact HPD at the Tenant Information Messaging Service at 212-863-4951.
    EmergencyClosed3BOct 2, 2024PAINT/PLASTER · CEILINGHPD conducted an inspection of this complaint. The conditions observed by the inspector did not violate the housing laws enforced by HPD. The complaint has been closed.
    Non-emergencyClosed3BOct 2, 2024UNSANITARY CONDITION · PESTSHPD inspected this condition so the complaint has been closed. Violations were issued. The law provides the property owner time to correct the condition(s). Violation descriptions and the dates for the property owner to correct any violations are available at HPDONLINE. If the owner has not corrected the condition by the date provided, you may wish to bring a case in housing court seeking the correction of these conditions.To find out more about how to start a housing court case, visit HPD's webpage on Housing Court (https://www.nyc.gov/site/hpd/services-and-information/housing-court.page).
    EmergencyClosed3BOct 2, 2024DOOR/WINDOW · DOORHPD inspected this condition so the complaint has been closed. Violations were issued. The law provides the property owner time to correct the condition(s). Violation descriptions and the dates for the property owner to correct any violations are available at HPDONLINE. If the owner has not corrected the condition by the date provided, you may wish to bring a case in housing court seeking the correction of these conditions.To find out more about how to start a housing court case, visit HPD's webpage on Housing Court (https://www.nyc.gov/site/hpd/services-and-information/housing-court.page).
    Non-emergencyClosed3BOct 2, 2024UNSANITARY CONDITION · PESTSHPD inspected this condition so the complaint has been closed. Violations were issued. The law provides the property owner time to correct the condition(s). Violation descriptions and the dates for the property owner to correct any violations are available at HPDONLINE. If the owner has not corrected the condition by the date provided, you may wish to bring a case in housing court seeking the correction of these conditions.To find out more about how to start a housing court case, visit HPD's webpage on Housing Court (https://www.nyc.gov/site/hpd/services-and-information/housing-court.page).
    Non-emergencyClosed3BOct 2, 2024GENERAL · CABINETHPD conducted an inspection of this complaint. The conditions observed by the inspector did not violate the housing laws enforced by HPD. The complaint has been closed.
    EmergencyClosedBSTAIRSep 12, 2024ELECTRIC · NO LIGHTINGThe Department of Housing Preservation and Development inspected the following conditions. Violations were issued. Information about specific violations is available at www.nyc.gov/hpd
    Non-emergencyClosedPORCHLSep 12, 2024ELECTRIC · NO LIGHTINGThe Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    Non-emergencyClosedBLDGAug 30, 2024ELECTRIC · NO LIGHTINGThe Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    Non-emergencyClosedBLDGAug 30, 2024ELECTRIC · NO LIGHTINGThe Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    EmergencyClosedBLDGAug 19, 2024ELECTRIC · NO LIGHTINGThe Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    EmergencyClosedBLDGAug 19, 2024ELECTRIC · NO LIGHTINGThe Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    Non-emergencyClosedWHOLEBAug 12, 2024ELECTRIC · NO LIGHTINGThe Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    Non-emergencyClosed1Jul 31, 2024GENERAL · BELL/BUZZER/INTERCOMHPD called the telephone number on file for this complaint. Someone at that number indicated that the condition was corrected. The complaint has been closed. Please submit a new service request with 311 if the condition still exists.
    EmergencyClosed10HJul 30, 2024PLUMBING · RADIATORThe Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    EmergencyClosed10HJul 30, 2024PLUMBING · RADIATORThe Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    EmergencyClosed10HJul 30, 2024PLUMBING · RADIATORThe Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    EmergencyClosed10HJul 30, 2024PLUMBING · RADIATORThe Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    EmergencyClosed10HJul 30, 2024PLUMBING · WATER SUPPLYThe Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    Non-emergencyClosed10HJul 30, 2024PLUMBING · WATER SUPPLYThe Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    EmergencyClosed10HJul 30, 2024GENERAL · CABINETThe Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    Non-emergencyClosed10HJul 30, 2024FLOORING/STAIRS · FLOORThe Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    EmergencyClosed10HJul 30, 2024PLUMBING · TOILETThe Department of Housing Preservation and Development inspected the following conditions. Violations were issued. Information about specific violations is available at www.nyc.gov/hpd
    Non-emergencyClosed10HJul 30, 2024PAINT/PLASTER · WALLThe Department of Housing Preservation and Development inspected the following conditions. Violations were issued. Information about specific violations is available at www.nyc.gov/hpd
    Non-emergencyClosed10HJul 30, 2024ELEVATOR · MAINTENANCEThe Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    Non-emergencyClosed10CJul 29, 2024ELECTRIC · NO LIGHTINGThe Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    Non-emergencyClosedBLDGJul 23, 2024ELECTRIC · NO LIGHTINGThe Department of Housing Preservation and Development inspected the following conditions. Violations were issued. Information about specific violations is available at www.nyc.gov/hpd
    Non-emergencyClosedBLDGJul 23, 2024ELECTRIC · POWER OUTAGEThe Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    EmergencyClosed10GJul 23, 2024ELECTRIC · NO LIGHTINGThe Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    EmergencyClosed10GJul 21, 2024ELECTRIC · NO LIGHTINGThe Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    EmergencyClosed10GJul 21, 2024ELECTRIC · NO LIGHTINGThe Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    EmergencyClosed
    Dec 2, 2024Apt BLDG
    HEAT/HOT WATER · ENTIRE BUILDING
    The Department of Housing Preservation and Development was not able to gain access to your apartment or others in the building to inspect for a lack of heat or hot water. The complaint has been closed. If the condition still exists, please file a new complaint.
    EmergencyClosed
    Nov 27, 2024Apt BLDG
    HEAT/HOT WATER · ENTIRE BUILDING
    The Department of Housing Preservation and Development was not able to gain access to your apartment or others in the building to inspect for a lack of heat or hot water. The complaint has been closed. If the condition still exists, please file a new complaint.
    EmergencyClosed
    Nov 23, 2024Apt 9G
    PLUMBING · WATER SUPPLY
    HPD attempted to conduct an inspection in response to this complaint, but was unable to complete the inspection. Please submit a new service request with 311 if the condition still exists. For more information on the reason why HPD was unable to inspect, contact HPD at the Tenant Information Messaging Service at 212-863-4951.
    Non-emergencyClosed
    Nov 23, 2024Apt BLDG
    PLUMBING · WATER SUPPLY
    More than one complaint was received for this building-wide condition. This complaint status is for the initial complaint.The Department of Housing Preservation and Development contacted a tenant in the building and verified that the following conditions were corrected. The complaint has been closed. If the condition still exists, please file a new complaint.
    Non-emergencyClosed
    Nov 23, 2024Apt 10H
    PLUMBING · WATER SUPPLY
    More than one complaint was received for this building-wide condition. This complaint status is for the initial complaint.HPD called the telephone number on file for this complaint. Someone at that number indicated that the condition was corrected. The complaint has been closed. Please submit a new service request with 311 if the condition still exists.
    Non-emergencyClosed
    Nov 23, 2024Apt BLDG
    PLUMBING · WATER SUPPLY
    The Department of Housing Preservation and Development contacted a tenant in the building and verified that the following conditions were corrected. The complaint has been closed. If the condition still exists, please file a new complaint.
    Non-emergencyClosed
    Nov 19, 2024Apt NA
    UNSANITARY CONDITION · GARBAGE/RECYCLING STORAGE
    HPD conducted an inspection of this complaint. The conditions observed by the inspector did not violate the housing laws enforced by HPD. The complaint has been closed.
    EmergencyClosed
    Nov 19, 2024Apt NA
    DOOR/WINDOW · DOOR
    HPD conducted an inspection of this complaint. The conditions observed by the inspector did not violate the housing laws enforced by HPD. The complaint has been closed.
    Non-emergencyClosed
    Oct 22, 2024Apt 5K
    GENERAL · CABINET
    An HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
    Non-emergencyClosed
    Oct 22, 2024Apt 5K
    PAINT/PLASTER · WALL
    An HPD Inspector was not able to gain access to inspect this complaint. The Inspector left a card at the time of the inspection and a letter was sent from HPD after the inspection attempt to encourage you to call to schedule an inspection. HPD did not receive a timely response from you and the complaint has been closed. Please submit a new service request with 311 if the condition still exists.
    Non-emergencyClosed
    Oct 18, 2024Apt 9G
    GENERAL · CABINET
    HPD conducted an inspection of this complaint. The conditions observed by the inspector did not violate the housing laws enforced by HPD. The complaint has been closed.
    EmergencyClosed
    Oct 18, 2024Apt 9G
    DOOR/WINDOW · DOOR
    HPD inspected this condition so the complaint has been closed. Violations were issued. The law provides the property owner time to correct the condition(s). Violation descriptions and the dates for the property owner to correct any violations are available at HPDONLINE. If the owner has not corrected the condition by the date provided, you may wish to bring a case in housing court seeking the correction of these conditions.To find out more about how to start a housing court case, visit HPD's webpage on Housing Court (https://www.nyc.gov/site/hpd/services-and-information/housing-court.page).
    EmergencyClosed
    Oct 18, 2024Apt 9G
    PLUMBING · BASIN/SINK
    HPD conducted an inspection of this complaint. The conditions observed by the inspector did not violate the housing laws enforced by HPD. The complaint has been closed.
    EmergencyClosed
    Oct 14, 2024Apt 5K
    HEAT/HOT WATER · APARTMENT ONLY
    HPD called the telephone number on file for this complaint. Someone at that number indicated that the condition was corrected. The complaint has been closed. Please submit a new service request with 311 if the condition still exists.
    Non-emergencyClosed
    Oct 9, 2024Apt 5K
    PLUMBING · WATER SUPPLY
    HPD attempted to conduct an inspection in response to this complaint, but was unable to complete the inspection. Please submit a new service request with 311 if the condition still exists. For more information on the reason why HPD was unable to inspect, contact HPD at the Tenant Information Messaging Service at 212-863-4951.
    Non-emergencyClosed
    Oct 9, 2024Apt 5K
    ELEVATOR · MAINTENANCE
    HPD conducted an inspection of this complaint. The conditions observed by the inspector did not violate the housing laws enforced by HPD. The complaint has been closed.
    EmergencyClosed
    Oct 9, 2024Apt 5K
    UNSANITARY CONDITION · MOLD
    HPD attempted to conduct an inspection in response to this complaint, but was unable to complete the inspection. Please submit a new service request with 311 if the condition still exists. For more information on the reason why HPD was unable to inspect, contact HPD at the Tenant Information Messaging Service at 212-863-4951.
    EmergencyClosed
    Oct 9, 2024Apt 5K
    SAFETY · CARBON MONOXIDE DETECTOR
    HPD attempted to conduct an inspection in response to this complaint, but was unable to complete the inspection. Please submit a new service request with 311 if the condition still exists. For more information on the reason why HPD was unable to inspect, contact HPD at the Tenant Information Messaging Service at 212-863-4951.
    EmergencyClosed
    Oct 9, 2024Apt 5K
    SAFETY · SMOKE DETECTOR
    HPD attempted to conduct an inspection in response to this complaint, but was unable to complete the inspection. Please submit a new service request with 311 if the condition still exists. For more information on the reason why HPD was unable to inspect, contact HPD at the Tenant Information Messaging Service at 212-863-4951.
    EmergencyClosed
    Oct 9, 2024Apt 5K
    DOOR/WINDOW · DOOR
    HPD attempted to conduct an inspection in response to this complaint, but was unable to complete the inspection. Please submit a new service request with 311 if the condition still exists. For more information on the reason why HPD was unable to inspect, contact HPD at the Tenant Information Messaging Service at 212-863-4951.
    EmergencyClosed
    Oct 2, 2024Apt 3B
    PAINT/PLASTER · CEILING
    HPD conducted an inspection of this complaint. The conditions observed by the inspector did not violate the housing laws enforced by HPD. The complaint has been closed.
    Non-emergencyClosed
    Oct 2, 2024Apt 3B
    UNSANITARY CONDITION · PESTS
    HPD inspected this condition so the complaint has been closed. Violations were issued. The law provides the property owner time to correct the condition(s). Violation descriptions and the dates for the property owner to correct any violations are available at HPDONLINE. If the owner has not corrected the condition by the date provided, you may wish to bring a case in housing court seeking the correction of these conditions.To find out more about how to start a housing court case, visit HPD's webpage on Housing Court (https://www.nyc.gov/site/hpd/services-and-information/housing-court.page).
    EmergencyClosed
    Oct 2, 2024Apt 3B
    DOOR/WINDOW · DOOR
    HPD inspected this condition so the complaint has been closed. Violations were issued. The law provides the property owner time to correct the condition(s). Violation descriptions and the dates for the property owner to correct any violations are available at HPDONLINE. If the owner has not corrected the condition by the date provided, you may wish to bring a case in housing court seeking the correction of these conditions.To find out more about how to start a housing court case, visit HPD's webpage on Housing Court (https://www.nyc.gov/site/hpd/services-and-information/housing-court.page).
    Non-emergencyClosed
    Oct 2, 2024Apt 3B
    UNSANITARY CONDITION · PESTS
    HPD inspected this condition so the complaint has been closed. Violations were issued. The law provides the property owner time to correct the condition(s). Violation descriptions and the dates for the property owner to correct any violations are available at HPDONLINE. If the owner has not corrected the condition by the date provided, you may wish to bring a case in housing court seeking the correction of these conditions.To find out more about how to start a housing court case, visit HPD's webpage on Housing Court (https://www.nyc.gov/site/hpd/services-and-information/housing-court.page).
    Non-emergencyClosed
    Oct 2, 2024Apt 3B
    GENERAL · CABINET
    HPD conducted an inspection of this complaint. The conditions observed by the inspector did not violate the housing laws enforced by HPD. The complaint has been closed.
    EmergencyClosed
    Sep 12, 2024Apt BSTAIR
    ELECTRIC · NO LIGHTING
    The Department of Housing Preservation and Development inspected the following conditions. Violations were issued. Information about specific violations is available at www.nyc.gov/hpd
    Non-emergencyClosed
    Sep 12, 2024Apt PORCHL
    ELECTRIC · NO LIGHTING
    The Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    Non-emergencyClosed
    Aug 30, 2024Apt BLDG
    ELECTRIC · NO LIGHTING
    The Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    Non-emergencyClosed
    Aug 30, 2024Apt BLDG
    ELECTRIC · NO LIGHTING
    The Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    EmergencyClosed
    Aug 19, 2024Apt BLDG
    ELECTRIC · NO LIGHTING
    The Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    EmergencyClosed
    Aug 19, 2024Apt BLDG
    ELECTRIC · NO LIGHTING
    The Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    Non-emergencyClosed
    Aug 12, 2024Apt WHOLEB
    ELECTRIC · NO LIGHTING
    The Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    Non-emergencyClosed
    Jul 31, 2024Apt 1
    GENERAL · BELL/BUZZER/INTERCOM
    HPD called the telephone number on file for this complaint. Someone at that number indicated that the condition was corrected. The complaint has been closed. Please submit a new service request with 311 if the condition still exists.
    EmergencyClosed
    Jul 30, 2024Apt 10H
    PLUMBING · RADIATOR
    The Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    EmergencyClosed
    Jul 30, 2024Apt 10H
    PLUMBING · RADIATOR
    The Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    EmergencyClosed
    Jul 30, 2024Apt 10H
    PLUMBING · RADIATOR
    The Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    EmergencyClosed
    Jul 30, 2024Apt 10H
    PLUMBING · RADIATOR
    The Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    EmergencyClosed
    Jul 30, 2024Apt 10H
    PLUMBING · WATER SUPPLY
    The Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    Non-emergencyClosed
    Jul 30, 2024Apt 10H
    PLUMBING · WATER SUPPLY
    The Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    EmergencyClosed
    Jul 30, 2024Apt 10H
    GENERAL · CABINET
    The Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    Non-emergencyClosed
    Jul 30, 2024Apt 10H
    FLOORING/STAIRS · FLOOR
    The Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    EmergencyClosed
    Jul 30, 2024Apt 10H
    PLUMBING · TOILET
    The Department of Housing Preservation and Development inspected the following conditions. Violations were issued. Information about specific violations is available at www.nyc.gov/hpd
    Non-emergencyClosed
    Jul 30, 2024Apt 10H
    PAINT/PLASTER · WALL
    The Department of Housing Preservation and Development inspected the following conditions. Violations were issued. Information about specific violations is available at www.nyc.gov/hpd
    Non-emergencyClosed
    Jul 30, 2024Apt 10H
    ELEVATOR · MAINTENANCE
    The Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    Non-emergencyClosed
    Jul 29, 2024Apt 10C
    ELECTRIC · NO LIGHTING
    The Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    Non-emergencyClosed
    Jul 23, 2024Apt BLDG
    ELECTRIC · NO LIGHTING
    The Department of Housing Preservation and Development inspected the following conditions. Violations were issued. Information about specific violations is available at www.nyc.gov/hpd
    Non-emergencyClosed
    Jul 23, 2024Apt BLDG
    ELECTRIC · POWER OUTAGE
    The Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    EmergencyClosed
    Jul 23, 2024Apt 10G
    ELECTRIC · NO LIGHTING
    The Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    EmergencyClosed
    Jul 21, 2024Apt 10G
    ELECTRIC · NO LIGHTING
    The Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
    EmergencyClosed
    Jul 21, 2024Apt 10G
    ELECTRIC · NO LIGHTING
    The Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.