Class BClosed
Oct 15, 2025Apt 4N
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELIN ENAMEL FINISH BY METHOD OF REGLAZING AT BATHTUB IN THE BATHROOM LOCATED AT APT 4N, 4th STORY, 6th APARTMENT FROM SOUTH AT WEST
Class BClosed
Oct 15, 2025Apt 4I
REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4I, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BClosed
Oct 15, 2025Apt 3E
TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT APT 3E, 3rd STORY, 3rd APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 18135535 ISSUED 30-JUL-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017.3a(3)(a) or (b).
Class BClosed
Oct 8, 2025Apt 3F
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL. IN THE BATHROOM LOCATED AT APT 3F, 3rd STORY, 3rd APARTMENT FROM NORTH AT EAST
Class BClosedRENT IMPAIRING
Oct 8, 2025Apt 3M
REPLACE DEFECTIVE SINK, WATER CLOSET, WASH TUB · SEWERS AND DRAINAGE
§ 27-2026 ADM CODE REPLACE THE BROKEN OR DEFECTIVE WATER CLOSET TANK IN THE BATHROOM LOCATED AT APT 3M, 3rd STORY, 5th APARTMENT FROM SOUTH AT WEST
Class BClosed
Oct 8, 2025Apt 2K
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE RUBBER GASKET AT UPPER AND LOWER REFRIGERATOR DOOR IN THE KITCHEN LOCATED AT APT 2K, 2nd STORY, 3rd APARTMENT FROM SOUTH AT WEST
Class BClosed
Oct 8, 2025Apt 2K
REPAIR · MAINTENANCE
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE DOORS AT SINK BASE CABINET IN THE KITCHEN LOCATED AT APT 2K, 2nd STORY, 3rd APARTMENT FROM SOUTH AT WEST
Class BClosed
Oct 8, 2025Apt 3F
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AT WINDOW CASING AND AT CEILING AT CLOSET IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 3F, 3rd STORY, 3rd APARTMENT FROM NORTH AT EAST
Class BClosed
Oct 8, 2025Apt 3F
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AT WINDOW CASING AND AT CEILING AT CLOSET IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 3F, 3rd STORY, 3rd APARTMENT FROM NORTH AT EAST
Class BClosed
Oct 8, 2025Apt 2K
REPAIR · MAINTENANCE
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE OUTLET AT NORTH WALL IN THE BATHROOM LOCATED AT APT 2K, 2nd STORY, 3rd APARTMENT FROM SOUTH AT WEST
Class BClosed
Oct 8, 2025Apt 2K
REPAIR/ABATE UNSAFE WIRES · ARTIFICIAL LIGHTING
§ 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED WIRES AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 2K, 2nd STORY, 3rd APARTMENT FROM SOUTH AT WEST
Class BClosed
Oct 8, 2025Apt 2K
REPAIR · MAINTENANCE
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING IN THE FOYER LOCATED AT APT 2K, 2nd STORY, 3rd APARTMENT FROM SOUTH AT WEST
Class BClosed
Oct 8, 2025Apt 2K
REPAIR · MAINTENANCE
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BELL BUZZER INTERCOM SYSTEM FROM THE BUILDING ENTRANCE DOOR TO THE APARTMENT EAST WALL PANEL. IN THE FOYER LOCATED AT APT 2K, 2nd STORY, 3rd APARTMENT FROM SOUTH AT WEST
Class BClosed
Oct 2, 2025Apt 4I
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE BATHROOM LOCATED AT APT 4I, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT SOUTH
Class BClosed
Oct 2, 2025Apt 4I
REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES THAT IS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4I, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT SOUTH
Class BClosed
Oct 2, 2025
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDAND MATERIAL AT CEILING IN FRONT OF APARTMENT 4E AT PUBLIC HALL, 4th STORY, SECTION AT SOUTH
Class BClosed
Oct 2, 2025Apt 4I
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 4I, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT SOUTH
Class BClosed
Oct 2, 2025
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AT PUBLIC HALL, 4th STORY, SECTION AT SOUTH
Class BClosed
Oct 2, 2025Apt 4I
REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS THAT IS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4I, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT SOUTH
Class BClosed
Sep 29, 2025Apt 1H
TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT NORTH AND EAST WALL UNDER SINK BASE CABINET IN THE KITCHEN LOCATED AT APT 1H, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 17929846 ISSUED 28-MAY-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017.3a(3)(a) or (b).
Class BClosed
Sep 29, 2025Apt 1H
TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 1H, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 17929839 ISSUED 28-MAY-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017.3a(3)(a) or (b).
Class BClosedRENT IMPAIRING
Sep 15, 2025Apt 5M
REMOVE OBSTRUCTIONS · SEWERS AND DRAINAGE
§ 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN AT WASTELINE AT WASH BASIN IN THE BATHROOM LOCATED AT APT 5M, 5th STORY, 4th APARTMENT FROM SOUTH AT WEST
Class BClosedRENT IMPAIRING
Sep 15, 2025Apt 5M
REMOVE OBSTRUCTIONS · SEWERS AND DRAINAGE
§ 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN AT WASTELINE AT BATHTUB IN THE BATHROOM LOCATED AT APT 5M, 5th STORY, 4th APARTMENT FROM SOUTH AT WEST
Class BClosed
Sep 15, 2025Apt 5M
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WEST WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 5M, 5th STORY, 4th APARTMENT FROM SOUTH AT WEST
Class BClosed
Sep 15, 2025Apt 5M
TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MORE THAN 10SQFT AT CEILING AND WEST WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 5M, 5th STORY, 4th APARTMENT FROM SOUTH AT WEST
Class BClosed
Sep 15, 2025Apt 5M
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 3rd ROOM FROM NORTH LOCATED AT APT 5M, 5th STORY, 4th APARTMENT FROM SOUTH AT WEST
Class BClosed
Aug 26, 2025
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT CEILING AT PUBLIC HALL, 4th STORY
Class BClosed
Aug 26, 2025
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT THE CEILING AT PUBLIC HALL, 5th STORY
Class BClosed
Aug 26, 2025Apt 3E
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT EAST WALL IN THE BATHROOM LOCATED AT APT 3E, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BClosed
Aug 26, 2025Apt 3E
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 3E, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BClosed
Aug 26, 2025Apt 1F
TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ.FT AT EAST WALL AND NORTH WALL IN THE KITCHEN LOCATED AT APT 1F, 1st STORY, 3rd APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 17853461 ISSUED 26-APR-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017.3a(3)(a) or (b).
Class BClosedRENT IMPAIRING
Aug 26, 2025
LEAKY ROOF · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING AT PUBLIC HALL, 8th STORY
Class BClosed
Aug 26, 2025Apt 5I
REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5I, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BClosed
Aug 26, 2025
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT THE CEILING AT PUBLIC HALL, 8th STORY
Class BClosed
Aug 26, 2025
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT CEILING AT PUBLIC HALL, 3rd STORY
Class BClosed
Aug 19, 2025Apt 3E
REPAIR LEAKY FAUCETS · WATER SUPPLY
§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT WASH BASIN IN THE KITCHEN LOCATED AT APT 3E, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BClosed
Aug 19, 2025Apt 3E
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 3E, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BClosed
Aug 19, 2025Apt 3E
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 3E, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BClosed
Aug 19, 2025Apt 3M
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 3M, 3rd STORY, 5th APARTMENT FROM SOUTH AT WEST
Class BClosed
Aug 19, 2025
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AND WEST WALL AT PUBLIC HALL, 5th STORY
Class BClosed
Aug 19, 2025Apt 3E
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 3E, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BClosed
Aug 19, 2025Apt 5I
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 3rd ROOM FROM NORTH AT WEST LOCATED AT APT 5I, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BClosed
Aug 19, 2025Apt 5I
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE .BACK SPLASH AT COUNTER TOP IN THE KITCHEN LOCATED AT APT 5I, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BOpen
Aug 19, 2025Apt 5I
REPAIR · MAINTENANCE
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BELL BUZZER/INTERCOM SYSTEM FROM BUILDING FRONT TO EAST WALL IN THE FOYER LOCATED AT APT 5I, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BClosed
Aug 19, 2025Apt 3M
TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 5SQFT OF MOLD FOUND AT WASH BASIN CABINET AT FLOOR . IN THE BATHROOM LOCATED AT APT 3M, 3rd STORY, 5th APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 17836602 ISSUED 17-APR-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).
Class BClosed
Aug 19, 2025Apt 5I
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE FOYER LOCATED AT APT 5I, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BClosed
Aug 11, 2025Apt 1F
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WEST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 1F, 1st STORY, 3rd APARTMENT FROM NORTH AT EAST
Class BClosed
Aug 11, 2025Apt 1F
TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GRATER THAN 10SQ FT AT NORTH AND SOUTH WALLS IN THE 1st ROOM FROM NORTH LOCATED AT APT 1F, 1st STORY, 3rd APARTMENT FROM NORTH AT EAST
Class BClosed
Aug 11, 2025Apt 1F
REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1F, 1st STORY, 3rd APARTMENT FROM NORTH AT EAST
Class BClosed
Aug 11, 2025Apt 1F
REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1F, 1st STORY, 3rd APARTMENT FROM NORTH AT EAST