stoop
MAP
LeaderboardAbout
Building SafetyHousing Conditions

2025 SEWARD AVENUE

Bronx · ZIP 10473 · BIN 2022208 · Castle Hill-Unionport · Last violation Sep 25, 2026 · Last complaint Sep 29, 2026

NeighborhoodCastle Hill-Unionport
More violations than 97% of nearby buildings
More violations than 97% of buildings and more complaints than 96% of buildings in Castle Hill-Unionport. Size-normalized against residential buildings in the neighborhood for issues in the last 10 years.
ViolationsComplaints
Activity TrendsLast 5 years
A steady level of activity over time
Last 2 yrs: 668 violations · 581 complaints
'21'26ViolationsComplaints
▼ View all activity over time
Severityⓘopen violations
91 immediately hazardous (Class C) violations still open
Class C violations include lead paint, mold, pest infestations, heat/hot water failure, and structural hazards — the most serious category.
Class Cimmediately hazardous91Class Bhazardous160

What to watch forⓘ

  1. Hazardous violations are open, including mold and pests, and fire safety.
    Worth checking · AI-assistedⓘ
    Look for droppings, live insects, or damage to walls, cabinets, and baseboards in the kitchen, bathroom, and under sinks. Check that apartment entry doors, stairwell doors, and fire escape access are all unlocked and open freely without obstruction.
    details ▸

    Deadlines vary by condition: immediate for heat and hot water, 14 days for self-closing doors, 21 days for lead paint, window guards, mold, and mice, cockroaches or rats, and 24 hours for everything else. They run from the date the owner is served, and mark when civil penalties can be sought in Housing Court. They are not a promise the condition is fixed by then. If the owner does not fix it, HPD can send its own contractor and bill them.

    • —Mold & pests — Rodent, cockroach, bedbug, or other pest infestation and extermination related issues.
    • —Safety & fire — Blocked, unsafe, or inaccessible exits, hallways, stairs, or fire escape routes.

    The violation list below shows which conditions are open and when each was cited. If one in your own apartment is still unaddressed, call 311.

Housing Preservation & Development Violations
Total violations since 2011
3,448
216 per year avg.→ Stable in the last 2 years
Open violations
266
Class C (immed. haz.)ⓘ91
Class B (hazardous)ⓘ160
Rent-impairingⓘ13
Housing Preservation & Development Complaints
Total complaints since 2003
2,990
125 per year avg.↑ Up 27% in the last 2 years (581 vs 458 prior 2 yrs)
Complaint Resolution
No access20%Violation issued27%No violation33%Phone resolved20%Other0%(2,990)
Urgency breakdown
Last 12 mo.

Top violation categories

5 yrsAll time
Maintenanceⓘ584 violations
Extermination & Rodent Eradicationⓘ215 violations
Water Supplyⓘ178 violations
Cleaningⓘ163 violations
Egressⓘ143 violations
Carbon Monoxide Detecting Devicesⓘ65 violations
Paintingⓘ63 violations
Smoke Detecting Devicesⓘ60 violations
Top complaint groupsⓘ
5 yrsAll time
Water & plumbingⓘ323 complaints
Mold & pestsⓘ304 complaints
Bldg maintenanceⓘ129 complaints
Heat / hot waterⓘ108 complaints
Appliancesⓘ65 complaints
Safety & fireⓘ48 complaints
Electricalⓘ36 complaints
Adminⓘ1 complaints
Hide violations ↑See complaints →

Violation log

2,201 violations · Class B

All classesClass AClass BClass CClass IAllOpenClosed
ClassStatusApt
See something wrong? File a complaint with 311
  • ABCs of Housing
  • NYC HPD, Penalties and Fees
  • Heat or hot water problems reported in the last five years.
    Worth checking · AI-assistedⓘ
    Turn on hot water at the kitchen sink and bathroom sink and feel the water temperature after running for one minute.
    details ▸

    Heat is required October 1 through May 31: at least 68°F from 6am to 10pm when it is below 55°F outside, and 62°F overnight whatever the temperature outside. Hot water must be at least 120°F, 24 hours a day, all year.

    If your apartment is colder than that, file a complaint with 311 and keep the service request number so you can track it. Never use a gas oven or range for heat, which can produce dangerous levels of carbon monoxide.

    • ABCs of Housing
  • Detector violations on record.
    Worth checking · AI-assistedⓘ
    Locate smoke detectors on the ceiling near bedrooms and in hallways, and ask the broker whether carbon monoxide detectors are present in the unit.
    details ▸

    Responsibility is split: the owner provides, installs, and replaces the detectors, while the tenant tests them monthly and replaces the batteries. An open violation means the owner has not yet certified to HPD that the condition was fixed, so a device may still be missing or dead at move-in. A tenant reimburses the owner for a newly installed device, $25 for a smoke or carbon monoxide detector and $50 for a combined unit, and is responsible for replacing one that goes missing or is damaged during the tenancy.

    On a viewing, look for a smoke alarm within fifteen feet of the door of each room used for sleeping, on the ceiling or just below it on the wall, and a carbon monoxide alarm at any height, including one plugged into a hallway outlet. Press the test button, and check that none have been painted over. A chirping alarm usually means a low battery, which is the tenant's to replace, but detectors also sound a separate end-of-life alarm when the device itself has to be replaced by the owner.

    • ABCs of Housing
    • NYC HPD, Smoke, Carbon Monoxide, and Natural Gas Detectors
  • Open violation ages
    ▪ < 30 days5% (12)
    ▪ 30–90 days13% (34)
    ▪ 3–12 months35% (93)
    ▪ 1–3 years31% (81)
    ▪ 3+ years17% (45)
    Prior 4 yr.
    Immed. Emergency2%4%
    Emergency56%47%
    Non-Emergency42%49%
    (178)
    (994)
    Issued
    Description
    Class BClosed4RJul 22, 2025REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 4R, 4th STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH
    Class BClosed5TJul 22, 2025REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 5T, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH
    Class BClosed4RJul 22, 2025REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4R, 4th STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH
    Class BClosed4RJul 22, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SINK BASECABINET ( BROKEN DRAWERS AND DOORS ) IN THE KITCHEN LOCATED AT APT 4R, 4th STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH
    Class BClosed4PJul 22, 2025REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND NORTH WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 4P, 4th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION AT NORTH
    Class BClosed4PJul 22, 2025REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 4P, 4th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION AT NORTH
    Class BClosed4RJul 22, 2025REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4R, 4th STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH
    Class BClosed—Jul 14, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE IN COMPACTOR CLOSET, DEFECTIVE LATCH SET AND ITS ASSEMBLIES AT HOPPER CHUTE DOOR, AT 1ST STORY, FROM SOUTH AT WEST SECTION,
    Class BClosed—Jul 14, 2025REMOVE VERMIN · EXTERMINATION & RODENT ERADICATION566 (B) 27-2021.4 HMC: ABATE THE NUISANCE CONSISTING OF PESTS. EVIDENCE OF FLIES AT BASEMENT STORY, PUBLIC HALL
    Class BClosed—Jul 14, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SETAND ITS ASSEMBLIES AT 1ST DOOR, FROM SOUTH AT EAST SECTION, LEADING TO PUBLIC STIAR CASE,AT BASEMENT STORY
    Class BClosed—Jun 27, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AND ASSEMBLY AT HOPPER DOOR. AT COMPACTOR CLOSET, 6th STORY, SECTION ''WEST''
    Class BClosed—Jun 27, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AND ASSEMBLY AT COMPACTOR CLOSET, 1st STORY, SECTION ''WEST''
    Class BClosed—Jun 27, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AND ASSEMBLY. AT COMPACTOR CLOSET, 6th STORY, SECTION ''WEST''
    Class BClosed5NJun 27, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MORTIISE LOCK AND ASSEMBLY. IN THE ENTRANCE LOCATED AT APT 5N, 5th STORY, SECTION ''WEST''
    Class BClosed—Jun 27, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AND ASSEMBLY AT HOPPER DOOR. AT COMPACTOR CLOSET, 1st STORY
    Class BClosed24Jun 27, 2025REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 24, 2nd APARTMENT FROM WEST AT NORTH
    Class BClosed—Jun 27, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AND ASSEMBLY AT ROOF DOOR AT 2nd PUBLIC HALL BULKHEAD FROM EAST, 7th STORY, SECTION ''WEST''
    Class BClosed3EJun 27, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BUZZER AND RETURN VOICE INTERCOM SYSTEM FROM BUILDING ENTRANCE DOOR UP TO PANEL AT EAST WALL IN THE PRIVATE HALLWAY LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''EAST''
    Class BClosed24Jun 27, 2025REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 24, 2nd APARTMENT FROM WEST AT NORTH
    Class BOpen7PJun 12, 2025REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR EAST WALL IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 7P, 7th STORY
    Class BClosed1Jun 12, 2025REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR SOUTH WALL IN THE FOYER LOCATED AT BSMT-APT 1, 1st BSMT-APT FROM WEST AT NORTH , SECTION AT EAST
    Class BClosed—Jun 12, 2025REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT SOUTH WALL AT BASEMENT AT PUBLIC HALL, SECTION AT EAST
    Class BOpen7PJun 12, 2025REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WEST WALL IN THE BATHROOM LOCATED AT APT 7P, 7th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION AT WEST
    Class BClosed4OJun 12, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT WEST WALL IN THE FOYER LOCATED AT APT 4O, 4th STORY, 3rd APARTMENT FROM NORTH AT EAST , SECTION AT WEST
    Class BClosed4OJun 12, 2025REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR NORTH WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 4O, 4th STORY, 3rd APARTMENT FROM NORTH AT EAST , SECTION AT WEST
    Class BClosed1Jun 12, 2025REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR EAST WALL IN THE 1st ROOM FROM EAST LOCATED AT BSMT-APT 1, 1st BSMT-APT FROM WEST AT NORTH , SECTION AT EAST
    Class BClosed4OJun 12, 2025REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR NORTH WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 4O, 4th STORY, 3rd APARTMENT FROM NORTH AT EAST , SECTION AT WEST
    Class BOpen7PJun 12, 2025REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR NORTH WALL IN THE KITCHEN LOCATED AT APT 7P, 7th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION AT WEST
    Class BClosed4TJun 3, 2025REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL WALLS IN THE KITCHEN LOCATED AT APT 4T, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT WEST
    Class BClosed4TJun 3, 2025REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 4T, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT WEST
    Class BClosed5NJun 3, 2025REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING, IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 5N, 5th STORY, 4th APARTMENT FROM NORTH AT EAST , SECTION AT WEST
    Class BClosed—Jun 3, 2025REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL CEILING BY ELEVATOR 10% AT PUBLIC HALL, 7th STORY, SECTION AT WEST
    Class BClosed4TJun 3, 2025REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMEL FINISH BY METHOD OF REGLAZING AT BATHTUB IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 4T, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT WEST
    Class BClosed3NJun 3, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MECHANICAL VENTILATION AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 3N, 3rd STORY, 4th APARTMENT FROM NORTH AT EAST , SECTION AT WEST
    Class BClosed4TJun 3, 2025REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4T, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT WEST
    Class BClosed7SJun 3, 2025REMOVE VERMIN · EXTERMINATION & RODENT ERADICATION566 (B) 27-2021.4 HMC: ABATE THE NUISANCE CONSISTING OF PESTS. EVIDENCE OF FLIES LOCATED AT APT 7S, 7th STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION AT WEST
    Class BClosed4TJun 3, 2025REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK OVER CEILING IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 4T, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT WEST
    Class BClosed1VJun 3, 2025REPAIR BROKEN, LOOSE CONNECTION · SEWERS AND DRAINAGE§ 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTE LINE AT SINK, IN THE KITCHEN LOCATED AT BSMT-APT 1V, 2nd BSMT-APT FROM EAST AT SOUTH , SECTION AT WEST
    Class BClosed5SJun 3, 2025REPAIR LEAKY FAUCETS · WATER SUPPLY§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT WASH BASIN, IN THE 2nd BATHROOM LOCATED AT APT 5S, 5th STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION AT WEST
    Class BClosedRENT IMPAIRING5SJun 3, 2025REMOVE OBSTRUCTIONS · SEWERS AND DRAINAGE§ 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTE LINE AT WASH BASIN, IN THE 1st BATHROOM LOCATED AT APT 5S, 5th STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION AT WEST
    Class BClosed5SJun 3, 2025REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING, IN THE PRIVATE HALLWAY LOCATED AT APT 5S, 5th STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION AT WEST
    Class BClosed7SJun 3, 2025REPAIR LEAKY FAUCETS · WATER SUPPLY§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB, IN THE 1st BATHROOM LOCATED AT APT 7S, 7th STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION AT WEST
    Class BClosed5SJun 3, 2025REPAIR LEAKY FAUCETS · WATER SUPPLY§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB, IN THE 2nd BATHROOM LOCATED AT APT 5S, 5th STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION AT WEST
    Class BClosed1VJun 3, 2025REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOORING AT BASE CABINET SINK IN THE KITCHEN LOCATED AT BSMT-APT 1V, 2nd BSMT-APT FROM EAST AT SOUTH , SECTION AT WEST
    Class BClosed1VJun 3, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MECHANICAL VENTILATION, IN THE BATHROOM LOCATED AT BSMT-APT 1V, 2nd BSMT-APT FROM EAST AT SOUTH , SECTION AT WEST
    Class BOpen5KJun 3, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE INTERCOMMUNICATION SYSTEM LOCATED AT APT 5K, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION AT EAST
    Class BClosed1VJun 3, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MECHANICAL VENTILATION, IN THE KITCHEN LOCATED AT BSMT-APT 1V, 2nd BSMT-APT FROM EAST AT SOUTH , SECTION AT WEST
    Class BClosed7SJun 3, 2025REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 7S, 7th STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION AT WEST
    Class BClosed4TJun 3, 2025REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULIKING AROUND BATHTUB IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 4T, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT WEST
    Class BClosed3NJun 3, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MECHANICAL VENTILATION AT WEST WALL, IN THE BATHROOM LOCATED AT APT 3N, 3rd STORY, 4th APARTMENT FROM NORTH AT EAST , SECTION AT WEST
    Class BClosed
    Jul 22, 2025Apt 4R
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 4R, 4th STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH
    Class BClosed
    Jul 22, 2025Apt 5T
    REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
    § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 5T, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH
    Class BClosed
    Jul 22, 2025Apt 4R
    REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
    § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4R, 4th STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH
    Class BClosed
    Jul 22, 2025Apt 4R
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SINK BASECABINET ( BROKEN DRAWERS AND DOORS ) IN THE KITCHEN LOCATED AT APT 4R, 4th STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH
    Class BClosed
    Jul 22, 2025Apt 4P
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND NORTH WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 4P, 4th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION AT NORTH
    Class BClosed
    Jul 22, 2025Apt 4P
    REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
    § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 4P, 4th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION AT NORTH
    Class BClosed
    Jul 22, 2025Apt 4R
    REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
    § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4R, 4th STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH
    Class BClosed
    Jul 14, 2025
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE IN COMPACTOR CLOSET, DEFECTIVE LATCH SET AND ITS ASSEMBLIES AT HOPPER CHUTE DOOR, AT 1ST STORY, FROM SOUTH AT WEST SECTION,
    Class BClosed
    Jul 14, 2025
    REMOVE VERMIN · EXTERMINATION & RODENT ERADICATION
    566 (B) 27-2021.4 HMC: ABATE THE NUISANCE CONSISTING OF PESTS. EVIDENCE OF FLIES AT BASEMENT STORY, PUBLIC HALL
    Class BClosed
    Jul 14, 2025
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SETAND ITS ASSEMBLIES AT 1ST DOOR, FROM SOUTH AT EAST SECTION, LEADING TO PUBLIC STIAR CASE,AT BASEMENT STORY
    Class BClosed
    Jun 27, 2025
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AND ASSEMBLY AT HOPPER DOOR. AT COMPACTOR CLOSET, 6th STORY, SECTION ''WEST''
    Class BClosed
    Jun 27, 2025
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AND ASSEMBLY AT COMPACTOR CLOSET, 1st STORY, SECTION ''WEST''
    Class BClosed
    Jun 27, 2025
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AND ASSEMBLY. AT COMPACTOR CLOSET, 6th STORY, SECTION ''WEST''
    Class BClosed
    Jun 27, 2025Apt 5N
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MORTIISE LOCK AND ASSEMBLY. IN THE ENTRANCE LOCATED AT APT 5N, 5th STORY, SECTION ''WEST''
    Class BClosed
    Jun 27, 2025
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AND ASSEMBLY AT HOPPER DOOR. AT COMPACTOR CLOSET, 1st STORY
    Class BClosed
    Jun 27, 2025Apt 24
    REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
    § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 24, 2nd APARTMENT FROM WEST AT NORTH
    Class BClosed
    Jun 27, 2025
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AND ASSEMBLY AT ROOF DOOR AT 2nd PUBLIC HALL BULKHEAD FROM EAST, 7th STORY, SECTION ''WEST''
    Class BClosed
    Jun 27, 2025Apt 3E
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BUZZER AND RETURN VOICE INTERCOM SYSTEM FROM BUILDING ENTRANCE DOOR UP TO PANEL AT EAST WALL IN THE PRIVATE HALLWAY LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''EAST''
    Class BClosed
    Jun 27, 2025Apt 24
    REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
    § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 24, 2nd APARTMENT FROM WEST AT NORTH
    Class BOpen
    Jun 12, 2025Apt 7P
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR EAST WALL IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 7P, 7th STORY
    Class BClosed
    Jun 12, 2025Apt 1
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR SOUTH WALL IN THE FOYER LOCATED AT BSMT-APT 1, 1st BSMT-APT FROM WEST AT NORTH , SECTION AT EAST
    Class BClosed
    Jun 12, 2025
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT SOUTH WALL AT BASEMENT AT PUBLIC HALL, SECTION AT EAST
    Class BOpen
    Jun 12, 2025Apt 7P
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WEST WALL IN THE BATHROOM LOCATED AT APT 7P, 7th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION AT WEST
    Class BClosed
    Jun 12, 2025Apt 4O
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT WEST WALL IN THE FOYER LOCATED AT APT 4O, 4th STORY, 3rd APARTMENT FROM NORTH AT EAST , SECTION AT WEST
    Class BClosed
    Jun 12, 2025Apt 4O
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR NORTH WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 4O, 4th STORY, 3rd APARTMENT FROM NORTH AT EAST , SECTION AT WEST
    Class BClosed
    Jun 12, 2025Apt 1
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR EAST WALL IN THE 1st ROOM FROM EAST LOCATED AT BSMT-APT 1, 1st BSMT-APT FROM WEST AT NORTH , SECTION AT EAST
    Class BClosed
    Jun 12, 2025Apt 4O
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR NORTH WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 4O, 4th STORY, 3rd APARTMENT FROM NORTH AT EAST , SECTION AT WEST
    Class BOpen
    Jun 12, 2025Apt 7P
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR NORTH WALL IN THE KITCHEN LOCATED AT APT 7P, 7th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION AT WEST
    Class BClosed
    Jun 3, 2025Apt 4T
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL WALLS IN THE KITCHEN LOCATED AT APT 4T, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT WEST
    Class BClosed
    Jun 3, 2025Apt 4T
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 4T, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT WEST
    Class BClosed
    Jun 3, 2025Apt 5N
    REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
    § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING, IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 5N, 5th STORY, 4th APARTMENT FROM NORTH AT EAST , SECTION AT WEST
    Class BClosed
    Jun 3, 2025
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL CEILING BY ELEVATOR 10% AT PUBLIC HALL, 7th STORY, SECTION AT WEST
    Class BClosed
    Jun 3, 2025Apt 4T
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMEL FINISH BY METHOD OF REGLAZING AT BATHTUB IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 4T, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT WEST
    Class BClosed
    Jun 3, 2025Apt 3N
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MECHANICAL VENTILATION AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 3N, 3rd STORY, 4th APARTMENT FROM NORTH AT EAST , SECTION AT WEST
    Class BClosed
    Jun 3, 2025Apt 4T
    REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
    § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4T, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT WEST
    Class BClosed
    Jun 3, 2025Apt 7S
    REMOVE VERMIN · EXTERMINATION & RODENT ERADICATION
    566 (B) 27-2021.4 HMC: ABATE THE NUISANCE CONSISTING OF PESTS. EVIDENCE OF FLIES LOCATED AT APT 7S, 7th STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION AT WEST
    Class BClosed
    Jun 3, 2025Apt 4T
    REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
    § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK OVER CEILING IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 4T, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT WEST
    Class BClosed
    Jun 3, 2025Apt 1V
    REPAIR BROKEN, LOOSE CONNECTION · SEWERS AND DRAINAGE
    § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTE LINE AT SINK, IN THE KITCHEN LOCATED AT BSMT-APT 1V, 2nd BSMT-APT FROM EAST AT SOUTH , SECTION AT WEST
    Class BClosed
    Jun 3, 2025Apt 5S
    REPAIR LEAKY FAUCETS · WATER SUPPLY
    § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT WASH BASIN, IN THE 2nd BATHROOM LOCATED AT APT 5S, 5th STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION AT WEST
    Class BClosedRENT IMPAIRING
    Jun 3, 2025Apt 5S
    REMOVE OBSTRUCTIONS · SEWERS AND DRAINAGE
    § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTE LINE AT WASH BASIN, IN THE 1st BATHROOM LOCATED AT APT 5S, 5th STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION AT WEST
    Class BClosed
    Jun 3, 2025Apt 5S
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING, IN THE PRIVATE HALLWAY LOCATED AT APT 5S, 5th STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION AT WEST
    Class BClosed
    Jun 3, 2025Apt 7S
    REPAIR LEAKY FAUCETS · WATER SUPPLY
    § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB, IN THE 1st BATHROOM LOCATED AT APT 7S, 7th STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION AT WEST
    Class BClosed
    Jun 3, 2025Apt 5S
    REPAIR LEAKY FAUCETS · WATER SUPPLY
    § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB, IN THE 2nd BATHROOM LOCATED AT APT 5S, 5th STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION AT WEST
    Class BClosed
    Jun 3, 2025Apt 1V
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOORING AT BASE CABINET SINK IN THE KITCHEN LOCATED AT BSMT-APT 1V, 2nd BSMT-APT FROM EAST AT SOUTH , SECTION AT WEST
    Class BClosed
    Jun 3, 2025Apt 1V
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MECHANICAL VENTILATION, IN THE BATHROOM LOCATED AT BSMT-APT 1V, 2nd BSMT-APT FROM EAST AT SOUTH , SECTION AT WEST
    Class BOpen
    Jun 3, 2025Apt 5K
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE INTERCOMMUNICATION SYSTEM LOCATED AT APT 5K, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION AT EAST
    Class BClosed
    Jun 3, 2025Apt 1V
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MECHANICAL VENTILATION, IN THE KITCHEN LOCATED AT BSMT-APT 1V, 2nd BSMT-APT FROM EAST AT SOUTH , SECTION AT WEST
    Class BClosed
    Jun 3, 2025Apt 7S
    REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
    § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 7S, 7th STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION AT WEST
    Class BClosed
    Jun 3, 2025Apt 4T
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULIKING AROUND BATHTUB IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 4T, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION AT WEST
    Class BClosed
    Jun 3, 2025Apt 3N
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MECHANICAL VENTILATION AT WEST WALL, IN THE BATHROOM LOCATED AT APT 3N, 3rd STORY, 4th APARTMENT FROM NORTH AT EAST , SECTION AT WEST
    Page 5 of 45