stoop
MAP
LeaderboardAbout
Building SafetyHousing Conditions

709 FAIRMOUNT PLACE

Bronx · ZIP 10457 · BIN 2009965 · Tremont · Last violation Sep 9, 2026 · Last complaint Sep 27, 2026

NeighborhoodTremont
More violations than 97% of nearby buildings
More violations than 97% of buildings and more complaints than 98% of buildings in Tremont. Size-normalized against residential buildings in the neighborhood for issues in the last 10 years.
ViolationsComplaints
Activity TrendsLast 5 years
A steady level of activity over time
Last 2 yrs: 262 violations · 448 complaints
'21'26ViolationsComplaints
▼ View all activity over time
Severityⓘopen violations
3 immediately hazardous (Class C) violations still open
Class C violations include lead paint, mold, pest infestations, heat/hot water failure, and structural hazards — the most serious category.
Class Cimmediately hazardous3Class Bhazardous15

What to watch forⓘ

  1. Hazardous violations are open, including mold and pests, and fire safety.
    Worth checking · AI-assistedⓘ
    Look for droppings, live insects, or damage to walls, cabinets, and baseboards in the kitchen, bathroom, and under sinks. Check that apartment entry doors, stairwell doors, and fire escape access are all unlocked and open freely without obstruction.
    details ▸

    Deadlines vary by condition: immediate for heat and hot water, 14 days for self-closing doors, 21 days for lead paint, window guards, mold, and mice, cockroaches or rats, and 24 hours for everything else. They run from the date the owner is served, and mark when civil penalties can be sought in Housing Court. They are not a promise the condition is fixed by then. If the owner does not fix it, HPD can send its own contractor and bill them.

    • —Mold & pests — Rodent, cockroach, bedbug, or other pest infestation and extermination related issues.
    • —Safety & fire — Blocked, unsafe, or inaccessible exits, hallways, stairs, or fire escape routes.

    The violation list below shows which conditions are open and when each was cited. If one in your own apartment is still unaddressed, call 311.

Housing Preservation & Development Violations
Total violations since 1994
3,828
116 per year avg.↓ Down 71% in the last 2 years (262 vs 901 prior 2 yrs)
Open violations
21
Class C (immed. haz.)ⓘ3
Class B (hazardous)ⓘ15
Rent-impairingⓘ0
Housing Preservation & Development Complaints
Total complaints since 2003
5,502
229 per year avg.↓ Down 26% in the last 2 years (448 vs 609 prior 2 yrs)
Complaint Resolution
No access17%Violation issued30%No violation37%Phone resolved17%Other0%(5,502)
Urgency breakdown
Last 12 mo.

Top violation categories

5 yrsAll time
Maintenanceⓘ610 violations
Extermination & Rodent Eradicationⓘ184 violations
Water Supplyⓘ174 violations
Cleaningⓘ140 violations
Egressⓘ113 violations
Paintingⓘ99 violations
Carbon Monoxide Detecting Devicesⓘ78 violations
Retiredⓘ78 violations
Top complaint groupsⓘ
5 yrsAll time
Heat / hot waterⓘ320 complaints
Water & plumbingⓘ276 complaints
Mold & pestsⓘ257 complaints
Bldg maintenanceⓘ210 complaints
Appliancesⓘ65 complaints
Electricalⓘ64 complaints
Safety & fireⓘ50 complaints
Outdoor / structuralⓘ1 complaints
Hide violations ↑See complaints →

Violation log

3,828 violations

All classesClass AClass BClass CClass IAllOpenClosed
ClassStatusApt
See something wrong? File a complaint with 311
  • ABCs of Housing
  • NYC HPD, Penalties and Fees
  • Heat or hot water problems reported in the last five years.
    Worth checking · AI-assistedⓘ
    Turn on hot water at the kitchen sink and bathroom sink and feel the water temperature after running for one minute.
    details ▸

    Heat is required October 1 through May 31: at least 68°F from 6am to 10pm when it is below 55°F outside, and 62°F overnight whatever the temperature outside. Hot water must be at least 120°F, 24 hours a day, all year.

    If your apartment is colder than that, file a complaint with 311 and keep the service request number so you can track it. Never use a gas oven or range for heat, which can produce dangerous levels of carbon monoxide.

    • ABCs of Housing
  • Detector violations on record.
    Worth checking · AI-assistedⓘ
    Locate smoke detectors on the ceiling near bedrooms and in hallways, and ask the broker whether carbon monoxide detectors are present in the unit.
    details ▸

    Responsibility is split: the owner provides, installs, and replaces the detectors, while the tenant tests them monthly and replaces the batteries. An open violation means the owner has not yet certified to HPD that the condition was fixed, so a device may still be missing or dead at move-in. A tenant reimburses the owner for a newly installed device, $25 for a smoke or carbon monoxide detector and $50 for a combined unit, and is responsible for replacing one that goes missing or is damaged during the tenancy.

    On a viewing, look for a smoke alarm within fifteen feet of the door of each room used for sleeping, on the ceiling or just below it on the wall, and a carbon monoxide alarm at any height, including one plugged into a hallway outlet. Press the test button, and check that none have been painted over. A chirping alarm usually means a low battery, which is the tenant's to replace, but detectors also sound a separate end-of-life alarm when the device itself has to be replaced by the owner.

    • ABCs of Housing
    • NYC HPD, Smoke, Carbon Monoxide, and Natural Gas Detectors
  • Open violation ages
    ▪ < 30 days24% (5)
    ▪ 30–90 days67% (14)
    ▪ 3–12 months10% (2)
    Prior 4 yr.
    Immed. Emergency5%4%
    Emergency72%54%
    Non-Emergency23%41%
    (194)
    (1,203)
    Issued
    Description
    Class AClosedD6Jul 23, 2015REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT D6, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION AT NORTH
    Class AClosedD3Jul 23, 2015REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES AT WASH BASIN IN THE BATHROOM LOCATED AT APT D3, 4th STORY, 1st APARTMENT FROM WEST AT NORTH , 1st SECTION FROM SOUTH AT WEST
    Class BClosedE1Jul 21, 2015REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MORTISE LOCK ON DOOR IN THE ENTRANCE LOCATED AT APT E1, 5th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''709'', 1st FROM SOUTH AT WEST
    Class AClosedE1Jul 21, 2015REFIT DOORS ETC. · EGRESS§ 27-2005 ADM CODE REFIT FIRE RATED DOOR IN THE ENTRANCE LOCATED AT APT E1, 5th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''709'', 1st FROM SOUTH AT WEST
    Class BClosedE1Jul 21, 2015REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT E1, 5th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''709'', 1st FROM SOUTH AT WEST
    Class CClosedE1Jul 21, 2015INSTALL/REPLACE/REPAIR WINDOW GUARDS (APT) · WINDOW GUARDS§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 1; WG TO REPLACE = 0; WG TO REPAIR = 1; MISSING W/G AND STOPS TO N/4/E,ONE WAY SCREWS MISSING N/2 ROOM IN THE ENTIRE APARTMENT LOCATED AT APT E1, 5th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''709'', 1st FROM SOUTH AT WEST
    Class CClosedA1Jul 17, 2015LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINT§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) NORTH WALL, SOUTH WALL, WEST WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT A1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''709''
    Class CClosedA1Jul 17, 2015LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINT§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING, SOUTH WALL, EAST WALL IN THE 4th ROOM FROM NORTH AT EAST LOCATED AT APT A1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''709''
    Class CClosedA1Jul 17, 2015LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINT§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING, EAST WALL IN THE BATHROOM LOCATED AT APT A1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''709''
    Class CClosedB10Jul 17, 2015LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINT§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) NORTH WALL, SOUTH WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT B10, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''715''
    Class CClosedD2Jul 17, 2015LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINT§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) EAST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT D2, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''709''
    Class CClosedD5Jul 17, 2015LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINT§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) NORTH WALL, WEST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT D5, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''711''
    Class CClosedD5Jul 17, 2015LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINT§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING IN THE BATHROOM LOCATED AT APT D5, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''711''
    Class AClosed—Jul 16, 2015PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 1st STORY, SECTION ''711''
    Class AClosedA5Jul 16, 2015FILE PLANS OR RESTORE · ALTERATIONS§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION SHEETROCK PARTITION WALL ERECTED FROM FLOOR TO CEILING CREATING ADDITIONAL ROOM IN THE 3rd ROOM FROM NORTH LOCATED AT APT A5, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''711''
    Class CClosedA5Jul 16, 2015INSTALL/REPLACE/REPAIR WINDOW GUARDS (APT) · WINDOW GUARDS§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 0; WG TO REPLACE = 0; WG TO REPAIR = 2; MISSING STOPPERS AT 1 WINDOW GUARD AND AND MISSING ONE-WAY SCREWS TO SECURE 1 AIR CONDITIONER WINDOW IN THE ENTIRE APARTMENT LOCATED AT APT A5, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''711''
    Class CClosedD5Jul 16, 2015REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT D5, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''711''
    Class CClosedD5Jul 16, 2015INSTALL/REPLACE/REPAIR WINDOW GUARDS (APT) · WINDOW GUARDS§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 0; WG TO REPLACE = 0; WG TO REPAIR = 2; MISSING ONE-WAY SCREWS TO SECURE 2 AIR CONDITIONER WINDOW IN THE ENTIRE APARTMENT LOCATED AT APT D5, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''711''
    Class BClosedA2Jul 16, 2015REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET COVER AT SOUTH WALL IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT A2, 1st STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''709''
    Class BClosedA2Jul 16, 2015REMOVE BARS OR GATES FROM NON FIRE ESCAPE WINDOW · EGRESS§ 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM AT LEAST 1 WINDOW OR PROVIDE APPROVED TYPE GATE LOCATED AT APT A2, 1st STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''709''
    Class CClosedE10Jul 16, 2015INSTALL/REPLACE/REPAIR WINDOW GUARDS (APT) · WINDOW GUARDS§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 0; WG TO REPLACE = 0; WG TO REPAIR = 4; MISSING STOPPERS IN 1 WINDOW GUARD AND MISSING ONE-WAY SCREWS TO SECURE 3 AIR CONDITIONER IN THE ENTIRE APARTMENT LOCATED AT APT E10, 5th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''715''
    Class CClosedB2Jul 16, 2015INSTALL/REPLACE/REPAIR WINDOW GUARDS (APT) · WINDOW GUARDS§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 0; WG TO REPLACE = 0; WG TO REPAIR = 3; MISSING STOPPERS IN 1 WINDOW GUARD, MISSING ONE-WAY SCREWS TO SECURE 1 WINDOW GUARD, MISSING ONE-WAY SCREWS TO SECURE 1 A/C WINDOW IN THE ENTIRE APARTMENT LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''709''
    Class CClosedD2Jul 16, 2015INSTALL/REPLACE/REPAIR WINDOW GUARDS (APT) · WINDOW GUARDS§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 0; WG TO REPLACE = 0; WG TO REPAIR = 1; MISSING STOPPERS IN 1 WINDOW GUARD IN THE ENTIRE APARTMENT LOCATED AT APT D2, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''709''
    Class CClosedE1Jul 16, 2015INSTALL/REPLACE/REPAIR WINDOW GUARDS (APT) · WINDOW GUARDS§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 0; WG TO REPLACE = 0; WG TO REPAIR = 2; MISSING ONE-WAY SCREWS TO SECURE 1 WINDOW GUARD AND MISSING ONE-WAY SCREWS TO SECURE 1 AIR CONDITIONER WINDOW IN THE ENTIRE APARTMENT LOCATED AT APT E1, 5th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''709''
    Class BClosed—Jul 16, 2015REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIALS AT CEILING AT PUBLIC HALL, 1st STORY, SECTION ''711''
    Class AClosedE1Jul 9, 2015PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE WEST WALL IN THE FOYER LOCATED AT APT E1, 5th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class CClosed—Jul 6, 2015RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE MARBLE TREAD #6 UP FROM BOTTOM AT PUBLIC HALL STAIRS, 2nd STORY
    Class BClosedE5Jun 25, 2015REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR EAST WALL AT BATHTUB IN THE BATHROOM LOCATED AT APT E5, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''BLDG 711''
    Class AClosedE5Jun 25, 2015PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE SOUTH WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT E5, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''BLDG 711''
    Class BClosedE5Jun 25, 2015REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT SOUTH AND WEST WALLS AT BATHTUB IN THE BATHROOM LOCATED AT APT E5, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''BLDG 711''
    Class CClosed—Jun 25, 2015RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE MARBLE TREAD #6 UP FROM BOTTOM AT PUBLIC HALL STAIRS, 2nd STORY, SECTION ''BLDG 711''
    Class AClosedA1Jun 23, 2015PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT A1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT WEST
    Class AClosedA1Jun 23, 2015PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING, EAST WALL, WEST WALL IN THE BATHROOM LOCATED AT APT A1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT WEST
    Class BClosedB11Jun 18, 2015REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOORS THROUGH OUT IN THE ENTIRE APARTMENT LOCATED AT APT B11, 2nd STORY, APARTMENT AT WEST , SECTION ''715'', AT EAST
    Class AClosedB11Jun 18, 2015FILE PLANS OR RESTORE · ALTERATIONS§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION STUD AND SHEETROCK CEILING INSTALLED DECREASING THE HEIGHT OF CEILING ,CREATING A FIRE HAZARD IN THE BATHROOM LOCATED AT APT B11, 2nd STORY, APARTMENT AT WEST , SECTION ''715''
    Class BClosedB11Jun 18, 2015REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT B11, 2nd STORY, APARTMENT AT WEST , SECTION ''715'', AT EAST
    Class BClosedB11Jun 18, 2015REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT B11, 2nd STORY, APARTMENT AT WEST , SECTION ''715'', AT EAST
    Class BClosed—Jun 18, 2015PROVIDE · MAINTENANCE§ 27-2005 ADM CODE PROVIDE AN UNLOCKABLE SLIDE BOLT OR HOOK ON BULKHEAD ROOF DOOR AT PUBLIC HALL STAIRS, 5th STORY, SECTION ''715''
    Class CClosed—Jun 18, 2015REPLACE · MAINTENANCE§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING DUMB WAITER DOOR AT BOILER ROOM AREA (CREATING A FIRE HAZARD) , SECTION ''715''
    Class CClosed—Jun 18, 2015INSTALL/REPLACE/REPAIR WINDOW GUARDS (PUBLIC AREA) · WINDOW GUARDS§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) THROUGHOUT THE PUBLIC AREAS IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. AT PUBLIC HALL STAIRS, SECTION ''715''
    Class AClosed—Jun 18, 2015FILE PLANS OR RESTORE · ALTERATIONS§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION ENCLOSURE CREATING A UTILITY CLOSET UNDER STAIRS AND BLOCKING OFF PASSAGE TO COURT YARD DOOR AT PUBLIC HALL, 1st STORY, SECTION ''715''
    Class BClosedRENT IMPAIRING—Jun 18, 2015F/E DEFECTIVE: PROPERLY SECURE · EGRESS§ 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. PROPERLY SECURE LOOSE GUSSET PLATE AT 3RD STORY BALCONY TOP RETURN RAIL ON THE 715 BUILDING SECTION WEST 2 STACK AT EAST YARD AT FIRE ESCAPE
    Class BClosedRENT IMPAIRING—Jun 18, 2015FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN · EGRESS§ 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN, DEFECTIVE AND/OR MISSING FIRST BATTEN FROM NORTH AT 2ND STY BALCONY ON THE 715 BUILDING SECTION WEST 2 STACK AT EAST YARD AT FIRE ESCAPE
    Class BClosedRENT IMPAIRING—Jun 18, 2015F/E DEFECTIVE: PROPERLY SECURE · EGRESS§ 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. PROPERLY SECURE LOOSE GUSSET PLATE AT FRONT RETURN RAIL AT 3RD STORY BALCONY ON THE 715 BUILDING SECTION WEST 2 STACK AT EAST YARD AT FIRE ESCAPE
    Class BClosedRENT IMPAIRING—Jun 18, 2015F/E DEFECTIVE: PROPERLY SECURE · EGRESS§ 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. PROPERLY SECURE UNSECURED GUSSET PLATE A TOP RAIL AT 5TH STORY BALCONY AT NORTH 2 STACK AT FRONT OF BUILDING AT FIRE ESCAPE
    Class CClosed—Jun 18, 2015ABATE THE NUISANCE · MAINTENANCE§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF FIRE PASSAGEWAY CEILING HEIGHT DECREASED BY APPROX: 18''. PER SECTION OF N.Y. MDW. LAW § 53 ,HEIGHT OF CEILING MUST BE 7' HIGH. , SECTION ''715''
    Class AClosed—Jun 18, 2015FILE PLANS OR RESTORE · ALTERATIONS§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION 18' W X 10' H CINDER BLOCK WALL ERECTED FROM FLOOR TO CEILING CREATING A GARBAGE RECEPTICLE AREA AT EAST FIRE PASSAGEWAY , SECTION ''715''
    Class CClosed—Jun 18, 2015REPLACE · MAINTENANCE§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING DUMB WAITER DOOR AT ROOM EAST1 WEST SECTION BLDG 711 CAMERA ROOM AREA (CREATING A FIRE HAZARD) , SECTION ''711''
    Class CClosed—Jun 18, 2015ABATE THE NUISANCE · MAINTENANCE§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF WEST WALL AT EAST FIRE PASSAGEWAY BREECHED BY APPROXIMATELY 12' WIDE SPAN AFFECTING SAFE EGRESS ( CREATING A FIRE HAZZARD ) , SECTION ''715''
    Class BClosed—Jun 18, 2015REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE ERRODED BRICK MORTAR JOINTS AT BREECHING AT BOILER ROOM FLUE , SECTION ''715''
    Class AClosed
    Jul 23, 2015Apt D6
    REPAIR · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT D6, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION AT NORTH
    Class AClosed
    Jul 23, 2015Apt D3
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES AT WASH BASIN IN THE BATHROOM LOCATED AT APT D3, 4th STORY, 1st APARTMENT FROM WEST AT NORTH , 1st SECTION FROM SOUTH AT WEST
    Class BClosed
    Jul 21, 2015Apt E1
    REPAIR · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MORTISE LOCK ON DOOR IN THE ENTRANCE LOCATED AT APT E1, 5th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''709'', 1st FROM SOUTH AT WEST
    Class AClosed
    Jul 21, 2015Apt E1
    REFIT DOORS ETC. · EGRESS
    § 27-2005 ADM CODE REFIT FIRE RATED DOOR IN THE ENTRANCE LOCATED AT APT E1, 5th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''709'', 1st FROM SOUTH AT WEST
    Class BClosed
    Jul 21, 2015Apt E1
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT E1, 5th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''709'', 1st FROM SOUTH AT WEST
    Class CClosed
    Jul 21, 2015Apt E1
    INSTALL/REPLACE/REPAIR WINDOW GUARDS (APT) · WINDOW GUARDS
    § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 1; WG TO REPLACE = 0; WG TO REPAIR = 1; MISSING W/G AND STOPS TO N/4/E,ONE WAY SCREWS MISSING N/2 ROOM IN THE ENTIRE APARTMENT LOCATED AT APT E1, 5th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''709'', 1st FROM SOUTH AT WEST
    Class CClosed
    Jul 17, 2015Apt A1
    LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINT
    § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) NORTH WALL, SOUTH WALL, WEST WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT A1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''709''
    Class CClosed
    Jul 17, 2015Apt A1
    LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINT
    § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING, SOUTH WALL, EAST WALL IN THE 4th ROOM FROM NORTH AT EAST LOCATED AT APT A1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''709''
    Class CClosed
    Jul 17, 2015Apt A1
    LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINT
    § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING, EAST WALL IN THE BATHROOM LOCATED AT APT A1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''709''
    Class CClosed
    Jul 17, 2015Apt B10
    LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINT
    § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) NORTH WALL, SOUTH WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT B10, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''715''
    Class CClosed
    Jul 17, 2015Apt D2
    LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINT
    § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) EAST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT D2, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''709''
    Class CClosed
    Jul 17, 2015Apt D5
    LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINT
    § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) NORTH WALL, WEST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT D5, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''711''
    Class CClosed
    Jul 17, 2015Apt D5
    LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINT
    § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING IN THE BATHROOM LOCATED AT APT D5, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''711''
    Class AClosed
    Jul 16, 2015
    PAINT · PAINTING
    § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 1st STORY, SECTION ''711''
    Class AClosed
    Jul 16, 2015Apt A5
    FILE PLANS OR RESTORE · ALTERATIONS
    § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION SHEETROCK PARTITION WALL ERECTED FROM FLOOR TO CEILING CREATING ADDITIONAL ROOM IN THE 3rd ROOM FROM NORTH LOCATED AT APT A5, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''711''
    Class CClosed
    Jul 16, 2015Apt A5
    INSTALL/REPLACE/REPAIR WINDOW GUARDS (APT) · WINDOW GUARDS
    § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 0; WG TO REPLACE = 0; WG TO REPAIR = 2; MISSING STOPPERS AT 1 WINDOW GUARD AND AND MISSING ONE-WAY SCREWS TO SECURE 1 AIR CONDITIONER WINDOW IN THE ENTIRE APARTMENT LOCATED AT APT A5, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''711''
    Class CClosed
    Jul 16, 2015Apt D5
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT D5, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''711''
    Class CClosed
    Jul 16, 2015Apt D5
    INSTALL/REPLACE/REPAIR WINDOW GUARDS (APT) · WINDOW GUARDS
    § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 0; WG TO REPLACE = 0; WG TO REPAIR = 2; MISSING ONE-WAY SCREWS TO SECURE 2 AIR CONDITIONER WINDOW IN THE ENTIRE APARTMENT LOCATED AT APT D5, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''711''
    Class BClosed
    Jul 16, 2015Apt A2
    REPAIR · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET COVER AT SOUTH WALL IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT A2, 1st STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''709''
    Class BClosed
    Jul 16, 2015Apt A2
    REMOVE BARS OR GATES FROM NON FIRE ESCAPE WINDOW · EGRESS
    § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM AT LEAST 1 WINDOW OR PROVIDE APPROVED TYPE GATE LOCATED AT APT A2, 1st STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''709''
    Class CClosed
    Jul 16, 2015Apt E10
    INSTALL/REPLACE/REPAIR WINDOW GUARDS (APT) · WINDOW GUARDS
    § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 0; WG TO REPLACE = 0; WG TO REPAIR = 4; MISSING STOPPERS IN 1 WINDOW GUARD AND MISSING ONE-WAY SCREWS TO SECURE 3 AIR CONDITIONER IN THE ENTIRE APARTMENT LOCATED AT APT E10, 5th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''715''
    Class CClosed
    Jul 16, 2015Apt B2
    INSTALL/REPLACE/REPAIR WINDOW GUARDS (APT) · WINDOW GUARDS
    § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 0; WG TO REPLACE = 0; WG TO REPAIR = 3; MISSING STOPPERS IN 1 WINDOW GUARD, MISSING ONE-WAY SCREWS TO SECURE 1 WINDOW GUARD, MISSING ONE-WAY SCREWS TO SECURE 1 A/C WINDOW IN THE ENTIRE APARTMENT LOCATED AT APT B2, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''709''
    Class CClosed
    Jul 16, 2015Apt D2
    INSTALL/REPLACE/REPAIR WINDOW GUARDS (APT) · WINDOW GUARDS
    § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 0; WG TO REPLACE = 0; WG TO REPAIR = 1; MISSING STOPPERS IN 1 WINDOW GUARD IN THE ENTIRE APARTMENT LOCATED AT APT D2, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''709''
    Class CClosed
    Jul 16, 2015Apt E1
    INSTALL/REPLACE/REPAIR WINDOW GUARDS (APT) · WINDOW GUARDS
    § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 0; WG TO REPLACE = 0; WG TO REPAIR = 2; MISSING ONE-WAY SCREWS TO SECURE 1 WINDOW GUARD AND MISSING ONE-WAY SCREWS TO SECURE 1 AIR CONDITIONER WINDOW IN THE ENTIRE APARTMENT LOCATED AT APT E1, 5th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''709''
    Class BClosed
    Jul 16, 2015
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIALS AT CEILING AT PUBLIC HALL, 1st STORY, SECTION ''711''
    Class AClosed
    Jul 9, 2015Apt E1
    PAINT · PAINTING
    § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE WEST WALL IN THE FOYER LOCATED AT APT E1, 5th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class CClosed
    Jul 6, 2015
    RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED
    § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE MARBLE TREAD #6 UP FROM BOTTOM AT PUBLIC HALL STAIRS, 2nd STORY
    Class BClosed
    Jun 25, 2015Apt E5
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR EAST WALL AT BATHTUB IN THE BATHROOM LOCATED AT APT E5, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''BLDG 711''
    Class AClosed
    Jun 25, 2015Apt E5
    PAINT · PAINTING
    § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE SOUTH WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT E5, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''BLDG 711''
    Class BClosed
    Jun 25, 2015Apt E5
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT SOUTH AND WEST WALLS AT BATHTUB IN THE BATHROOM LOCATED AT APT E5, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''BLDG 711''
    Class CClosed
    Jun 25, 2015
    RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED
    § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE MARBLE TREAD #6 UP FROM BOTTOM AT PUBLIC HALL STAIRS, 2nd STORY, SECTION ''BLDG 711''
    Class AClosed
    Jun 23, 2015Apt A1
    PAINT · PAINTING
    § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT A1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT WEST
    Class AClosed
    Jun 23, 2015Apt A1
    PAINT · PAINTING
    § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING, EAST WALL, WEST WALL IN THE BATHROOM LOCATED AT APT A1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT WEST
    Class BClosed
    Jun 18, 2015Apt B11
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOORS THROUGH OUT IN THE ENTIRE APARTMENT LOCATED AT APT B11, 2nd STORY, APARTMENT AT WEST , SECTION ''715'', AT EAST
    Class AClosed
    Jun 18, 2015Apt B11
    FILE PLANS OR RESTORE · ALTERATIONS
    § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION STUD AND SHEETROCK CEILING INSTALLED DECREASING THE HEIGHT OF CEILING ,CREATING A FIRE HAZARD IN THE BATHROOM LOCATED AT APT B11, 2nd STORY, APARTMENT AT WEST , SECTION ''715''
    Class BClosed
    Jun 18, 2015Apt B11
    REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
    § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT B11, 2nd STORY, APARTMENT AT WEST , SECTION ''715'', AT EAST
    Class BClosed
    Jun 18, 2015Apt B11
    REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
    § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT B11, 2nd STORY, APARTMENT AT WEST , SECTION ''715'', AT EAST
    Class BClosed
    Jun 18, 2015
    PROVIDE · MAINTENANCE
    § 27-2005 ADM CODE PROVIDE AN UNLOCKABLE SLIDE BOLT OR HOOK ON BULKHEAD ROOF DOOR AT PUBLIC HALL STAIRS, 5th STORY, SECTION ''715''
    Class CClosed
    Jun 18, 2015
    REPLACE · MAINTENANCE
    § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING DUMB WAITER DOOR AT BOILER ROOM AREA (CREATING A FIRE HAZARD) , SECTION ''715''
    Class CClosed
    Jun 18, 2015
    INSTALL/REPLACE/REPAIR WINDOW GUARDS (PUBLIC AREA) · WINDOW GUARDS
    § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) THROUGHOUT THE PUBLIC AREAS IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. AT PUBLIC HALL STAIRS, SECTION ''715''
    Class AClosed
    Jun 18, 2015
    FILE PLANS OR RESTORE · ALTERATIONS
    § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION ENCLOSURE CREATING A UTILITY CLOSET UNDER STAIRS AND BLOCKING OFF PASSAGE TO COURT YARD DOOR AT PUBLIC HALL, 1st STORY, SECTION ''715''
    Class BClosedRENT IMPAIRING
    Jun 18, 2015
    F/E DEFECTIVE: PROPERLY SECURE · EGRESS
    § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. PROPERLY SECURE LOOSE GUSSET PLATE AT 3RD STORY BALCONY TOP RETURN RAIL ON THE 715 BUILDING SECTION WEST 2 STACK AT EAST YARD AT FIRE ESCAPE
    Class BClosedRENT IMPAIRING
    Jun 18, 2015
    FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN · EGRESS
    § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN, DEFECTIVE AND/OR MISSING FIRST BATTEN FROM NORTH AT 2ND STY BALCONY ON THE 715 BUILDING SECTION WEST 2 STACK AT EAST YARD AT FIRE ESCAPE
    Class BClosedRENT IMPAIRING
    Jun 18, 2015
    F/E DEFECTIVE: PROPERLY SECURE · EGRESS
    § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. PROPERLY SECURE LOOSE GUSSET PLATE AT FRONT RETURN RAIL AT 3RD STORY BALCONY ON THE 715 BUILDING SECTION WEST 2 STACK AT EAST YARD AT FIRE ESCAPE
    Class BClosedRENT IMPAIRING
    Jun 18, 2015
    F/E DEFECTIVE: PROPERLY SECURE · EGRESS
    § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. PROPERLY SECURE UNSECURED GUSSET PLATE A TOP RAIL AT 5TH STORY BALCONY AT NORTH 2 STACK AT FRONT OF BUILDING AT FIRE ESCAPE
    Class CClosed
    Jun 18, 2015
    ABATE THE NUISANCE · MAINTENANCE
    § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF FIRE PASSAGEWAY CEILING HEIGHT DECREASED BY APPROX: 18''. PER SECTION OF N.Y. MDW. LAW § 53 ,HEIGHT OF CEILING MUST BE 7' HIGH. , SECTION ''715''
    Class AClosed
    Jun 18, 2015
    FILE PLANS OR RESTORE · ALTERATIONS
    § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION 18' W X 10' H CINDER BLOCK WALL ERECTED FROM FLOOR TO CEILING CREATING A GARBAGE RECEPTICLE AREA AT EAST FIRE PASSAGEWAY , SECTION ''715''
    Class CClosed
    Jun 18, 2015
    REPLACE · MAINTENANCE
    § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING DUMB WAITER DOOR AT ROOM EAST1 WEST SECTION BLDG 711 CAMERA ROOM AREA (CREATING A FIRE HAZARD) , SECTION ''711''
    Class CClosed
    Jun 18, 2015
    ABATE THE NUISANCE · MAINTENANCE
    § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF WEST WALL AT EAST FIRE PASSAGEWAY BREECHED BY APPROXIMATELY 12' WIDE SPAN AFFECTING SAFE EGRESS ( CREATING A FIRE HAZZARD ) , SECTION ''715''
    Class BClosed
    Jun 18, 2015
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE ERRODED BRICK MORTAR JOINTS AT BREECHING AT BOILER ROOM FLUE , SECTION ''715''
    Page 61 of 77