1075 NELSON AVENUE

Bronx · ZIP 10452 · BIN 2003262 · Highbridge · Last violation Sep 18, 2026 · Last complaint Sep 30, 2026

NeighborhoodHighbridge
More violations than 90% of nearby buildings
More violations than 90% of buildings and more complaints than 94% of buildings in Highbridge. Size-normalized against residential buildings in the neighborhood for issues in the last 10 years.
ViolationsComplaints
Activity TrendsLast 5 years
A steady level of activity over time
Last 2 yrs: 170 violations · 187 complaints
'21'26ViolationsComplaints
▼ View all activity over time
Severityⓘopen violations
19 immediately hazardous (Class C) violations still open
Class C violations include lead paint, mold, pest infestations, heat/hot water failure, and structural hazards — the most serious category.
Class Cimmediately hazardous19Class Bhazardous67

What to watch forⓘ

  1. Hazardous violations are open, including building maintenance, mold and pests, and fire safety.
    Worth checking · AI-assistedⓘ
    Look at baseboards, trim, and door frames for signs of warping, soft spots, or gaps; check walls and ceilings in corners and under sinks for discoloration or staining. Open kitchen and bathroom cabinets and look for droppings, dead insects, or live pests in corners and along edges. Test that doors and windows on fire escape routes open freely, and look for blocked or cluttered hallways or stairwells.
    details ▸

    Deadlines vary by condition: immediate for heat and hot water, 14 days for self-closing doors, 21 days for lead paint, window guards, mold, and mice, cockroaches or rats, and 24 hours for everything else. They run from the date the owner is served, and mark when civil penalties can be sought in Housing Court. They are not a promise the condition is fixed by then. If the owner does not fix it, HPD can send its own contractor and bill them.

    • —Bldg maintenance — General building repair, upkeep, and maintenance related housing code violations.
    • —Mold & pests — Rodent, cockroach, bedbug, or other pest infestation and extermination related issues.
Housing Preservation & Development Violations
Total violations since 2013
636
45 per year avg.↓ Down 40% in the last 2 years (170 vs 282 prior 2 yrs)
Open violations
98
Class C (immed. haz.)ⓘ19
Class B (hazardous)ⓘ67
Rent-impairingⓘ1
Housing Preservation & Development Complaints
Total complaints since 2003
1,428
60 per year avg.↓ Down 13% in the last 2 years (187 vs 214 prior 2 yrs)
Complaint Resolution
No access15%Violation issued19%No violation25%Phone resolved41%Other0%(1,428)
Urgency breakdown
Last 12 mo.

Top violation categories

5 yrsAll time
Maintenanceⓘ192 violations
Cleaningⓘ52 violations
Extermination & Rodent Eradicationⓘ38 violations
Water Supplyⓘ36 violations
Smoke Detecting Devicesⓘ35 violations
Carbon Monoxide Detecting Devicesⓘ35 violations
Paintingⓘ34 violations
Egressⓘ26 violations
Top complaint groupsⓘ
5 yrsAll time
Heat / hot waterⓘ190 complaints
Bldg maintenanceⓘ66 complaints
Mold & pestsⓘ55 complaints
Water & plumbingⓘ46 complaints
Safety & fireⓘ31 complaints
Appliancesⓘ18 complaints
Electricalⓘ12 complaints
Adminⓘ3 complaints
Outdoor / structuralⓘ1 complaints
Hide violations ↑See complaints →

Violation log

538 violations · Close

All classesClass AClass BClass CClass IAllOpenClosed
ClassStatusApt
See something wrong? File a complaint with 311
—
Safety & fire — Blocked, unsafe, or inaccessible exits, hallways, stairs, or fire escape routes.

The violation list below shows which conditions are open and when each was cited. If one in your own apartment is still unaddressed, call 311.

  • ABCs of Housing
  • NYC HPD, Penalties and Fees
  • Heat or hot water problems reported in the last five years.
    Worth checking · AI-assistedⓘ
    Turn on hot water at the kitchen sink and bathroom sink and feel the water temperature after running for one minute.
    details ▸

    Heat is required October 1 through May 31: at least 68°F from 6am to 10pm when it is below 55°F outside, and 62°F overnight whatever the temperature outside. Hot water must be at least 120°F, 24 hours a day, all year.

    If your apartment is colder than that, file a complaint with 311 and keep the service request number so you can track it. Never use a gas oven or range for heat, which can produce dangerous levels of carbon monoxide.

    • ABCs of Housing
  • Lead-paint violations on record.
    Worth checking · AI-assistedⓘ
    Look for paint that is peeling, chipped, or cracked on interior walls, trim, windows, doors, and door frames.
    details ▸

    Buildings built before 1960 may still contain lead-based paint, which causes behavioral and learning problems in young children, who can swallow dust and paint chips from windowsills and floors.

    If a child under six lives with you, or spends 10 or more hours a week in your apartment, tell the owner in writing, which is what obliges them to inspect annually. Report peeling paint, and call 311 if it is not fixed or if repair work is raising dust that is not being contained.

    • ABCs of Housing
  • Open violation ages
    ▪ < 30 days2% (2)
    ▪ 30–90 days11% (11)
    ▪ 3–12 months7% (7)
    ▪ 1–3 years49% (47)
    ▪ 3+ years30% (29)
    Prior 4 yr.
    Immed. Emergency1%3%
    Emergency76%71%
    Non-Emergency23%26%
    (95)
    (351)
    Issued
    Description
    Class BClosed—Jan 25, 2023REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES FLOOR AT PUBLIC HALL, 1st STORY
    Class BClosed—Jan 25, 2023REMOVE ENCUMBRANCE · EGRESS§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES AIR CONDITIONER INSTALLED AT WINDOW AT 6TH STORY BALCONY AT NORTH STACK BUILDING FRONT AT FIRE ESCAPE
    Class BClosed—Jan 25, 2023REMOVE ENCUMBRANCE · EGRESS§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES AIR CONDITIONER INSTALLED AT WINDOW AT 2ND STORY BALCONY AT NORTH STACK BUILDING FRONT AT FIRE ESCAPE
    Class BClosed—Jan 25, 2023REMOVE ENCUMBRANCE · EGRESS§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES HOUSE HOLD ITEMS AT 3RD STORY BALCONY AT SOUTH STACK BUILDING FRONT AT FIRE ESCAPE
    Class CClosed—Jan 25, 2023RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE LOCKING DEVICE AT DOOR AT BUILDING ENTRANCE , 1st STORY
    Class CClosed—Jan 25, 2023DOOR NOT SELF-CLOSING · EGRESS§ 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING KICK DOWN DOOR STOP INSTALLED AT VESTIBULE DOOR , 1st STORY
    Class BClosed—Jan 25, 2023REMOVE ACCUMULATION OR RUBBISH · CLEANING§ 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE FLOOR AT PUBLIC HALL, 6th STORY
    Class BClosed1DJan 25, 2023REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1D, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosed2DJan 25, 2023REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES FLOOR IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class CClosed4BJan 11, 2023INSTALL/REPLACE/REPAIR WINDOW GUARDS (APT) · WINDOW GUARDS§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 1, WG TO REPLACE = 1, WG TO REPAIR = 1 IN THE ENTIRE APARTMENT LOCATED AT APT 4B, 4th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class BClosed4BJan 11, 2023REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 4B, 4th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class BClosed4BJan 11, 2023REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 4B, 4th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class AClosed—Jan 5, 2023PROVIDE SHOE FOR DROP LADDER · FIRE EGRESS AND PROTECTION§ 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER MISSING AT 1st FIRE ESCAPE FROM NORTH AT WEST
    Class AClosed—Jan 5, 2023PROVIDE SHOE FOR DROP LADDER · FIRE EGRESS AND PROTECTION§ 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER MISSING AT 2nd FIRE ESCAPE FROM NORTH AT WEST
    Class CClosed—Jan 5, 2023REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK AND ASSEMBLIES AT BUILDING ENTRANCE DOOR , 1st STORY
    Class AClosed—Jan 5, 2023CLEANSE · CLEANING§ 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE FLOOR AT PUBLIC HALL, 4th STORY
    Class BClosed2DNov 7, 2022REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CEREMIC FLOOR TILES IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class BClosed—Nov 7, 2022RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE MARBLE TREAD 5TH UP FROM THE BOTTOM AT PUBLIC HALL STAIRS, 2nd STORY
    Class AClosed2DNov 7, 2022TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CELLING APPRX 4 SQ FEET IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class CClosed—Nov 7, 2022REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MORTISE LOCK AT BULDING ENTRANCE DOOR , 1st STORY
    Class BClosed5BAug 18, 2022REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class CClosed5BAug 18, 2022REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR APPROXIMATELY 16 SQ. FT. UNKEYED PLASTER AT CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class CClosed5BAug 18, 2022ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATIONHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class BClosed—Aug 18, 2022REPLACE · MAINTENANCE§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ELECTRICAL OUTLET COVER PLATE AT NORTH WALL AT PUBLIC HALL, 1st STORY
    Class AClosed5BAug 18, 2022PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE FOYER , THE 2nd ROOM FROM EAST AT SOUTH, THE BATHROOM , THE 1st ROOM FROM EAST LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class BClosed5BAug 18, 2022ABATE THE NUISANCE · MAINTENANCE§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF UNCAPPED RADIATOR VALVE AT EAST WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class CClosed5BAug 18, 2022INSTALL/REPLACE/REPAIR WINDOW GUARDS (APT) · WINDOW GUARDS§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 0; WG TO REPLACE = 0; WG TO REPAIR = 1; MISSING ONE WAY SCREWS AT AC IN THE ENTIRE APARTMENT LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class CClosed5BAug 18, 2022RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE INNER GLASS PANE AT UPPER SASH AT FIRE ESCAPE WINDOW IN THE 1st ROOM FROM EAST LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class BClosed5BAug 18, 2022REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class AClosed2DJun 28, 2022RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GASKET AT REFRIDGERATOR DOOR LOWER IN THE KITCHEN LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class AClosedBASEMEJun 28, 2022TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROXIMATELY 2 SQ.FT AT CEILING AND 2 SQ.FT AT WEST WALL IN THE BATHROOM LOCATED AT BSMT-APT BASEME, 2nd BSMT-APT FROM SOUTH AT WEST
    Class BClosed2DJun 14, 2022REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class BClosed2DMay 4, 2022REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE SOUTH WALL IN THE KITCHEN LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class BClosed2DMay 4, 2022REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class CClosed2DMay 4, 2022MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ... IN THE ENTRANCE LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class BClosed2DMay 4, 2022REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LIGHT SWITCH AT WEST WALL IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class BClosed2DMay 4, 2022SECURE LOOSE MATTER · MAINTENANCE§ 27-2005 ADM CODE PROPERLY SECURE THE LOOSE SINK'S FAUCET IN THE KITCHEN LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class CClosed2DMay 4, 2022ABATE THE NUISANCE OF MICE · EXTERMINATION & RODENT ERADICATIONHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class BClosed2DMar 1, 2022TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING APPROX 6 SQ FT IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 14649754 ISSUED 30-OCT-21 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).
    Class BClosed2DFeb 18, 2022TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROXIMATELY 2 SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 14632158 ISSUED 20-OCT-21 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).
    Class CClosedRENT IMPAIRING1ADec 23, 2021INADEQUATE HOT WATER · HEAT AND HOT WATER§ 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STORY, 3rd APARTMENT FROM SOUTH AT WEST
    Class BClosed2DNov 1, 2021RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE AIR VALVE ON RADIATOR AT SOUTH WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class BClosed2DNov 1, 2021REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class BClosed2DNov 1, 2021RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE RUBBER GASKET AT REFRIGERATOR DOOR IN THE KITCHEN LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class AClosed2DNov 1, 2021PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class AClosed2DNov 1, 2021TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING APPROX 6 SQ FT IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class AClosed2DNov 1, 2021PROVIDE · MAINTENANCE§ 27-2005 ADM CODE PROVIDE ESCUTCHEON PLATE ON STEAM RISER AT NORTH WALL IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class BClosedRENT IMPAIRING2DNov 1, 2021REPAIR FLUSHING APPARATUS OF WATER CLOSET · SEWERS AND DRAINAGE§ 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class BClosed2DNov 1, 2021REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH AND EAST WALLS IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class BClosed2DNov 1, 2021REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class BClosed
    Jan 25, 2023
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES FLOOR AT PUBLIC HALL, 1st STORY
    Class BClosed
    Jan 25, 2023
    REMOVE ENCUMBRANCE · EGRESS
    § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES AIR CONDITIONER INSTALLED AT WINDOW AT 6TH STORY BALCONY AT NORTH STACK BUILDING FRONT AT FIRE ESCAPE
    Class BClosed
    Jan 25, 2023
    REMOVE ENCUMBRANCE · EGRESS
    § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES AIR CONDITIONER INSTALLED AT WINDOW AT 2ND STORY BALCONY AT NORTH STACK BUILDING FRONT AT FIRE ESCAPE
    Class BClosed
    Jan 25, 2023
    REMOVE ENCUMBRANCE · EGRESS
    § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES HOUSE HOLD ITEMS AT 3RD STORY BALCONY AT SOUTH STACK BUILDING FRONT AT FIRE ESCAPE
    Class CClosed
    Jan 25, 2023
    RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED
    § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE LOCKING DEVICE AT DOOR AT BUILDING ENTRANCE , 1st STORY
    Class CClosed
    Jan 25, 2023
    DOOR NOT SELF-CLOSING · EGRESS
    § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING KICK DOWN DOOR STOP INSTALLED AT VESTIBULE DOOR , 1st STORY
    Class BClosed
    Jan 25, 2023
    REMOVE ACCUMULATION OR RUBBISH · CLEANING
    § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE FLOOR AT PUBLIC HALL, 6th STORY
    Class BClosed
    Jan 25, 2023Apt 1D
    REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
    § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1D, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Jan 25, 2023Apt 2D
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES FLOOR IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class CClosed
    Jan 11, 2023Apt 4B
    INSTALL/REPLACE/REPAIR WINDOW GUARDS (APT) · WINDOW GUARDS
    § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 1, WG TO REPLACE = 1, WG TO REPAIR = 1 IN THE ENTIRE APARTMENT LOCATED AT APT 4B, 4th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class BClosed
    Jan 11, 2023Apt 4B
    REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
    § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 4B, 4th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class BClosed
    Jan 11, 2023Apt 4B
    REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
    § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 4B, 4th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class AClosed
    Jan 5, 2023
    PROVIDE SHOE FOR DROP LADDER · FIRE EGRESS AND PROTECTION
    § 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER MISSING AT 1st FIRE ESCAPE FROM NORTH AT WEST
    Class AClosed
    Jan 5, 2023
    PROVIDE SHOE FOR DROP LADDER · FIRE EGRESS AND PROTECTION
    § 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER MISSING AT 2nd FIRE ESCAPE FROM NORTH AT WEST
    Class CClosed
    Jan 5, 2023
    REPAIR · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK AND ASSEMBLIES AT BUILDING ENTRANCE DOOR , 1st STORY
    Class AClosed
    Jan 5, 2023
    CLEANSE · CLEANING
    § 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE FLOOR AT PUBLIC HALL, 4th STORY
    Class BClosed
    Nov 7, 2022Apt 2D
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CEREMIC FLOOR TILES IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class BClosed
    Nov 7, 2022
    RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED
    § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE MARBLE TREAD 5TH UP FROM THE BOTTOM AT PUBLIC HALL STAIRS, 2nd STORY
    Class AClosed
    Nov 7, 2022Apt 2D
    TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
    § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CELLING APPRX 4 SQ FEET IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class CClosed
    Nov 7, 2022
    REPAIR · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MORTISE LOCK AT BULDING ENTRANCE DOOR , 1st STORY
    Class BClosed
    Aug 18, 2022Apt 5B
    REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
    § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class CClosed
    Aug 18, 2022Apt 5B
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR APPROXIMATELY 16 SQ. FT. UNKEYED PLASTER AT CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class CClosed
    Aug 18, 2022Apt 5B
    ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATION
    HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class BClosed
    Aug 18, 2022
    REPLACE · MAINTENANCE
    § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ELECTRICAL OUTLET COVER PLATE AT NORTH WALL AT PUBLIC HALL, 1st STORY
    Class AClosed
    Aug 18, 2022Apt 5B
    PAINT · PAINTING
    § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE FOYER , THE 2nd ROOM FROM EAST AT SOUTH, THE BATHROOM , THE 1st ROOM FROM EAST LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class BClosed
    Aug 18, 2022Apt 5B
    ABATE THE NUISANCE · MAINTENANCE
    § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF UNCAPPED RADIATOR VALVE AT EAST WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class CClosed
    Aug 18, 2022Apt 5B
    INSTALL/REPLACE/REPAIR WINDOW GUARDS (APT) · WINDOW GUARDS
    § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 0; WG TO REPLACE = 0; WG TO REPAIR = 1; MISSING ONE WAY SCREWS AT AC IN THE ENTIRE APARTMENT LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class CClosed
    Aug 18, 2022Apt 5B
    RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED
    § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE INNER GLASS PANE AT UPPER SASH AT FIRE ESCAPE WINDOW IN THE 1st ROOM FROM EAST LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class BClosed
    Aug 18, 2022Apt 5B
    REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
    § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class AClosed
    Jun 28, 2022Apt 2D
    RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED
    § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GASKET AT REFRIDGERATOR DOOR LOWER IN THE KITCHEN LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class AClosed
    Jun 28, 2022Apt BASEME
    TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
    § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROXIMATELY 2 SQ.FT AT CEILING AND 2 SQ.FT AT WEST WALL IN THE BATHROOM LOCATED AT BSMT-APT BASEME, 2nd BSMT-APT FROM SOUTH AT WEST
    Class BClosed
    Jun 14, 2022Apt 2D
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class BClosed
    May 4, 2022Apt 2D
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE SOUTH WALL IN THE KITCHEN LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class BClosed
    May 4, 2022Apt 2D
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class CClosed
    May 4, 2022Apt 2D
    MAKE DOORS SELF-CLOSING · EGRESS
    § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ... IN THE ENTRANCE LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class BClosed
    May 4, 2022Apt 2D
    REPAIR · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LIGHT SWITCH AT WEST WALL IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class BClosed
    May 4, 2022Apt 2D
    SECURE LOOSE MATTER · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE SINK'S FAUCET IN THE KITCHEN LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class CClosed
    May 4, 2022Apt 2D
    ABATE THE NUISANCE OF MICE · EXTERMINATION & RODENT ERADICATION
    HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class BClosed
    Mar 1, 2022Apt 2D
    TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
    § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING APPROX 6 SQ FT IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 14649754 ISSUED 30-OCT-21 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).
    Class BClosed
    Feb 18, 2022Apt 2D
    TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
    § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROXIMATELY 2 SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 14632158 ISSUED 20-OCT-21 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).
    Class CClosedRENT IMPAIRING
    Dec 23, 2021Apt 1A
    INADEQUATE HOT WATER · HEAT AND HOT WATER
    § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STORY, 3rd APARTMENT FROM SOUTH AT WEST
    Class BClosed
    Nov 1, 2021Apt 2D
    RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED
    § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE AIR VALVE ON RADIATOR AT SOUTH WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class BClosed
    Nov 1, 2021Apt 2D
    REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
    § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class BClosed
    Nov 1, 2021Apt 2D
    RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED
    § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE RUBBER GASKET AT REFRIGERATOR DOOR IN THE KITCHEN LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class AClosed
    Nov 1, 2021Apt 2D
    PAINT · PAINTING
    § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class AClosed
    Nov 1, 2021Apt 2D
    TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
    § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING APPROX 6 SQ FT IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class AClosed
    Nov 1, 2021Apt 2D
    PROVIDE · MAINTENANCE
    § 27-2005 ADM CODE PROVIDE ESCUTCHEON PLATE ON STEAM RISER AT NORTH WALL IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class BClosedRENT IMPAIRING
    Nov 1, 2021Apt 2D
    REPAIR FLUSHING APPARATUS OF WATER CLOSET · SEWERS AND DRAINAGE
    § 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class BClosed
    Nov 1, 2021Apt 2D
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH AND EAST WALLS IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class BClosed
    Nov 1, 2021Apt 2D
    REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
    § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Page 8 of 11