Severityⓘopen violations
30 immediately hazardous (Class C) violations still open
Class C violations include lead paint, mold, pest infestations, heat/hot water failure, and structural hazards — the most serious category.
Class Cimmediately hazardous30Class Bhazardous46

What to watch forⓘ

  1. Hazardous violations are open, including fire safety, heat and hot water, and mold and pests.
    Worth checking · AI-assistedⓘ
    Look for blocked stairwells, hallways, or exits, and check that all doors in the unit open and close fully. Turn on the heat and feel whether warm air comes from the radiators or vents. Inspect baseboards, corners, and under sinks for droppings, dead insects, or gnaw marks.
    details ▸

    Deadlines vary by condition: immediate for heat and hot water, 14 days for self-closing doors, 21 days for lead paint, window guards, mold, and mice, cockroaches or rats, and 24 hours for everything else. They run from the date the owner is served, and mark when civil penalties can be sought in Housing Court. They are not a promise the condition is fixed by then. If the owner does not fix it, HPD can send its own contractor and bill them.

    • —Safety & fire — Blocked, unsafe, or inaccessible exits, hallways, stairs, or fire escape routes.
    • —Heat / hot water — Lack of heat, hot water, or heating system related issues affecting tenants.
    • —
Housing Preservation & Development Violations
Total violations since 2005
897
41 per year avg.↑ Up 133% in the last 2 years (200 vs 86 prior 2 yrs)
Open violations
84
Class C (immed. haz.)ⓘ30
Class B (hazardous)ⓘ46
Rent-impairingⓘ8
Housing Preservation & Development Complaints
Total complaints since 2003
2,419
101 per year avg.↑ Up 640% in the last 2 years (933 vs 126 prior 2 yrs)
Complaint Resolution
No access11%Violation issued17%No violation20%Phone resolved51%Other1%(2,419)
Urgency breakdown
Last 12 mo.

Top violation categories

5 yrsAll time
Maintenanceⓘ103 violations
Egressⓘ52 violations
Heat And Hot Waterⓘ29 violations
Carbon Monoxide Detecting Devicesⓘ19 violations
Smoke Detecting Devicesⓘ19 violations
Water Supplyⓘ19 violations
Extermination & Rodent Eradicationⓘ17 violations
Cleaningⓘ16 violations
Top complaint groupsⓘ
5 yrsAll time
Heat / hot waterⓘ922 complaints
Bldg maintenanceⓘ41 complaints
Mold & pestsⓘ39 complaints
Water & plumbingⓘ27 complaints
Elevatorⓘ12 complaints
Safety & fireⓘ7 complaints
Electricalⓘ4 complaints
Appliancesⓘ3 complaints
Outdoor / structuralⓘ3 complaints
Adminⓘ3 complaints
Hide violations ↑See complaints →

Violation log

813 violations · Close

All classesClass AClass BClass CClass IAllOpenClosed
ClassStatusApt
See something wrong? File a complaint with 311
Mold & pests — Rodent, cockroach, bedbug, or other pest infestation and extermination related issues.

The violation list below shows which conditions are open and when each was cited. If one in your own apartment is still unaddressed, call 311.

  • ABCs of Housing
  • NYC HPD, Penalties and Fees
  • Detector violations on record.
    Worth checking · AI-assistedⓘ
    Locate smoke detectors on the ceiling near bedrooms and in hallways, and ask the broker whether carbon monoxide detectors are present in the unit.
    details ▸

    Responsibility is split: the owner provides, installs, and replaces the detectors, while the tenant tests them monthly and replaces the batteries. An open violation means the owner has not yet certified to HPD that the condition was fixed, so a device may still be missing or dead at move-in. A tenant reimburses the owner for a newly installed device, $25 for a smoke or carbon monoxide detector and $50 for a combined unit, and is responsible for replacing one that goes missing or is damaged during the tenancy.

    On a viewing, look for a smoke alarm within fifteen feet of the door of each room used for sleeping, on the ceiling or just below it on the wall, and a carbon monoxide alarm at any height, including one plugged into a hallway outlet. Press the test button, and check that none have been painted over. A chirping alarm usually means a low battery, which is the tenant's to replace, but detectors also sound a separate end-of-life alarm when the device itself has to be replaced by the owner.

    • ABCs of Housing
    • NYC HPD, Smoke, Carbon Monoxide, and Natural Gas Detectors
  • Open violation ages
    ▪ < 30 days25% (21)
    ▪ 30–90 days30% (25)
    ▪ 3–12 months32% (27)
    ▪ 1–3 years7% (6)
    ▪ 3+ years6% (5)
    Prior 4 yr.
    Immed. Emergency0%3%
    Emergency98%68%
    Non-Emergency2%30%
    (859)
    (229)
    Issued
    Description
    Class CClosed—Feb 8, 2023MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT PUBLIC HALL, 3rd STORY
    Class CClosedRENT IMPAIRING5HJan 30, 2023INADEQUATE HEAT · HEAT AND HOT WATER§ 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 5H, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH
    Class CClosed—Jan 30, 2023PROVIDE ACCESS TO BOILER ROOM · HEAT AND HOT WATER§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT BOILER ROOM
    Class CClosed—Sep 8, 2022ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATIONHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES AT PUBLIC HALL, 5th STORY
    Class CClosed—Sep 8, 2022ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATIONHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES AT PUBLIC HALL, 5th STORY
    Class CClosedAAug 16, 2022MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE IN THE ENTRANCE LOCATED AT APT A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT NORTHWEST
    Class CClosed—Jul 25, 2022POST BOILER ROOM ACCESS NOTICE · HEAT AND HOT WATER§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM AT OR NEAR MAIL BOX (INCORRECT INFORMATION)
    Class CClosed3JJul 25, 2022MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ... IN THE ENTRANCE LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class CClosed—Jul 25, 2022MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE FIRE DOOR AT 3RD STORY PUBLIC HALL
    Class AClosed—Jul 25, 2022POST SIGN INDICATING NAME AND ADDRESS OF JANITOR, ETC. · POSTING/SIGNAGE§ 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER.
    Class CClosed—Jun 10, 2022MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LEADING TO WEST SECTION AT PUBLIC HALL, 1st STORY
    Class BClosedRENT IMPAIRING—Jun 6, 2022LEAKY ROOF · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AROUND SKYLIGHT , 7th STORY
    Class CClosed—Jul 27, 2021POST BOILER ROOM ACCESS NOTICE · HEAT AND HOT WATER§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING AT PUBLIC HALL, 1st STORY
    Class AClosed6KJul 21, 2021NO PEEP HOLE · PROTECTIVE DEVICES AND FIRE PROTECTION§ 27-2041 ADM CODE PROVIDE A PEEP HOLE IN ENTRANCE DOOR OF THE DWELLING UNIT SO LOCATED SO AS TO PERMIT A PERSON INSIDE THE DWELLING TO VIEW ANY PERSON OUTSIDE ENTRANCE DOOR .. IN THE ENTRANCE LOCATED AT APT 6K, 6th STORY, 4th APARTMENT FROM EAST AT SOUTH
    Class BClosed6KJul 21, 2021REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND WEST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 6K, 6th STORY, 4th APARTMENT FROM EAST AT SOUTH
    Class AClosed6KJul 21, 2021REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL BUZZER INTERCOM SYSTEM LOCATED AT APT 6K, 6th STORY, 4th APARTMENT FROM EAST AT SOUTH
    Class BClosed6GJul 9, 2021REPLACE · MAINTENANCE§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ESCUTCHEON PLATE AT HEAT RISER TOP AND BOTTOM IN THE BATHROOM LOCATED AT APT 6G, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class AClosed6GJul 9, 2021PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING IN THE BATHROOM LOCATED AT APT 6G, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class CClosed6GJul 9, 2021ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATIONHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 6G, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosed6GJul 9, 2021REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING AROUND BATH TUB IN THE BATHROOM LOCATED AT APT 6G, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosed6GJul 9, 2021REMOVE VERMIN · EXTERMINATION & RODENT ERADICATIONHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF VERMIN FLIES IN THE ENTIRE APARTMENT LOCATED AT APT 6G, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class CClosed6GJul 9, 2021MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 2007, 204.1 HMC CODE: ARRANGE AND MAKE SELF-CLOSING THE DOORS .. IN THE ENTRANCE LOCATED AT APT 6G, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosed6GJul 9, 2021TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING IN THE BATHROOM LOCATED AT APT 6G, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class AClosed3JJun 21, 2021PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND EAST WALL IN THE BATHROOM LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed3JJun 21, 2021REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOODEN FLOOR IN THE ENTIRE APARTMENT LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class CClosed3JJun 21, 2021TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING AND EAST WALL IN THE BATHROOM LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed—Jun 18, 2021REMOVE ENCUMBRANCE · EGRESS§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES AIR CONDITIONER UNIT AT BALCONY REAR AT CENTER STACK AT FIRE ESCAPE, 4th STORY
    Class BClosed—Jun 9, 2021REMOVE ENCUMBRANCE · EGRESS§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES AIR CONDITIONER UNIT PROTRUDING AT WINDOW INTO FIRE ESCAPE BALCONY AT REAR , 4th STORY
    Class AClosed3JJun 9, 2021PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed3JJun 1, 2021REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR EAST AND WEST WALL IN THE BATHROOM LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed—Jun 1, 2021REMOVE ENCUMBRANCE · EGRESS§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES AIR CONDITIONER IN WINDOW PROTRUDING AT BALCONY 4TH STORY AT FIRE ESCAPE, 4th STORY
    Class AClosed3JJun 1, 2021CLEANSE · CLEANING§ 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE MOLD CERAMIC WALLS TILES IN THE BATHROOM LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed3JJun 1, 2021REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT EAST AND WEST WALL IN THE BATHROOM LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed—Jun 1, 2021REMOVE ACCUMULATION OR RUBBISH · CLEANING§ 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE FIRE PASSAGEWAY , 1st STORY
    Class CClosed3JJun 1, 2021TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING APPROX 40 SQ FT IN THE BATHROOM LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed6HMay 28, 2021TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT SOUTH WALL AAPPROXIMATELY 4 SQUARE FEET IN THE 1st ROOM FROM EAST LOCATED AT APT 6H, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 13944409 ISSUED 27-JAN-21 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).
    Class BClosed3JMay 20, 2021REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL GFCI OUTLETS AT NORTH WALL IN THE KITCHENETTE LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH , SECTION AT EAST
    Class CClosed3JMay 20, 2021ABATE THE NUISANCE · MAINTENANCE§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF UNCAPPED GAS VALVE IN THE KITCHENETTE LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH , SECTION AT EAST
    Class BClosed3JMay 20, 2021REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE (ROTTED) HARD WOOD FLOOR IN THE FOYER LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH , SECTION AT EAST
    Class BClosed3JMay 20, 2021REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH , SECTION AT EAST
    Class BClosed—May 20, 2021REMOVE ENCUMBRANCE · EGRESS§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES FLOWER PLANTER ON 3RD STY BALCONY AT 2ND FIRE ESCAPE FROM EAST AT BUILDING FRONT AT FIRE ESCAPE
    Class AClosed3JMay 20, 2021REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE EAST WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH , SECTION AT EAST
    Class AClosed—Apr 7, 2021POST SIGN INDICATING NAME AND ADDRESS OF JANITOR, ETC. · POSTING/SIGNAGE§ 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORY
    Class BClosed3JApr 7, 2021REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class CClosed3JApr 7, 2021REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER SASH WINDOW IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed3JApr 7, 2021REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER SASH WINDOW IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class CClosed6HFeb 17, 2021ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATIONHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 6H, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH
    Class CClosed6HFeb 17, 2021RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE RADIATOR AIR VALVE IN THE 1st ROOM FROM EAST LOCATED AT APT 6H, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH
    Class AClosed6HFeb 17, 2021REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE EAST AND SOUTH WALLS IN THE 1st ROOM FROM EAST LOCATED AT APT 6H, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH
    Class CClosed6EFeb 17, 2021MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 2007, 204.1 HMC CODE: ARRANGE AND MAKE SELF-CLOSING THE DOORS .. IN THE ENTRANCE LOCATED AT APT 6E, 6th STORY, 5th APARTMENT FROM WEST AT NORTH
    Class CClosed
    Feb 8, 2023
    MAKE DOORS SELF-CLOSING · EGRESS
    § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT PUBLIC HALL, 3rd STORY
    Class CClosedRENT IMPAIRING
    Jan 30, 2023Apt 5H
    INADEQUATE HEAT · HEAT AND HOT WATER
    § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 5H, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH
    Class CClosed
    Jan 30, 2023
    PROVIDE ACCESS TO BOILER ROOM · HEAT AND HOT WATER
    § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT BOILER ROOM
    Class CClosed
    Sep 8, 2022
    ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATION
    HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES AT PUBLIC HALL, 5th STORY
    Class CClosed
    Sep 8, 2022
    ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATION
    HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES AT PUBLIC HALL, 5th STORY
    Class CClosed
    Aug 16, 2022Apt A
    MAKE DOORS SELF-CLOSING · EGRESS
    § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE IN THE ENTRANCE LOCATED AT APT A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT NORTHWEST
    Class CClosed
    Jul 25, 2022
    POST BOILER ROOM ACCESS NOTICE · HEAT AND HOT WATER
    § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM AT OR NEAR MAIL BOX (INCORRECT INFORMATION)
    Class CClosed
    Jul 25, 2022Apt 3J
    MAKE DOORS SELF-CLOSING · EGRESS
    § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ... IN THE ENTRANCE LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class CClosed
    Jul 25, 2022
    MAKE DOORS SELF-CLOSING · EGRESS
    § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE FIRE DOOR AT 3RD STORY PUBLIC HALL
    Class AClosed
    Jul 25, 2022
    POST SIGN INDICATING NAME AND ADDRESS OF JANITOR, ETC. · POSTING/SIGNAGE
    § 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER.
    Class CClosed
    Jun 10, 2022
    MAKE DOORS SELF-CLOSING · EGRESS
    § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LEADING TO WEST SECTION AT PUBLIC HALL, 1st STORY
    Class BClosedRENT IMPAIRING
    Jun 6, 2022
    LEAKY ROOF · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AROUND SKYLIGHT , 7th STORY
    Class CClosed
    Jul 27, 2021
    POST BOILER ROOM ACCESS NOTICE · HEAT AND HOT WATER
    § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING AT PUBLIC HALL, 1st STORY
    Class AClosed
    Jul 21, 2021Apt 6K
    NO PEEP HOLE · PROTECTIVE DEVICES AND FIRE PROTECTION
    § 27-2041 ADM CODE PROVIDE A PEEP HOLE IN ENTRANCE DOOR OF THE DWELLING UNIT SO LOCATED SO AS TO PERMIT A PERSON INSIDE THE DWELLING TO VIEW ANY PERSON OUTSIDE ENTRANCE DOOR .. IN THE ENTRANCE LOCATED AT APT 6K, 6th STORY, 4th APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Jul 21, 2021Apt 6K
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND WEST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 6K, 6th STORY, 4th APARTMENT FROM EAST AT SOUTH
    Class AClosed
    Jul 21, 2021Apt 6K
    REPAIR · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL BUZZER INTERCOM SYSTEM LOCATED AT APT 6K, 6th STORY, 4th APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Jul 9, 2021Apt 6G
    REPLACE · MAINTENANCE
    § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ESCUTCHEON PLATE AT HEAT RISER TOP AND BOTTOM IN THE BATHROOM LOCATED AT APT 6G, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class AClosed
    Jul 9, 2021Apt 6G
    PAINT · PAINTING
    § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING IN THE BATHROOM LOCATED AT APT 6G, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class CClosed
    Jul 9, 2021Apt 6G
    ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATION
    HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 6G, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Jul 9, 2021Apt 6G
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING AROUND BATH TUB IN THE BATHROOM LOCATED AT APT 6G, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Jul 9, 2021Apt 6G
    REMOVE VERMIN · EXTERMINATION & RODENT ERADICATION
    HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF VERMIN FLIES IN THE ENTIRE APARTMENT LOCATED AT APT 6G, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class CClosed
    Jul 9, 2021Apt 6G
    MAKE DOORS SELF-CLOSING · EGRESS
    § 27-2005, 2007, 204.1 HMC CODE: ARRANGE AND MAKE SELF-CLOSING THE DOORS .. IN THE ENTRANCE LOCATED AT APT 6G, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Jul 9, 2021Apt 6G
    TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
    § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING IN THE BATHROOM LOCATED AT APT 6G, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class AClosed
    Jun 21, 2021Apt 3J
    PAINT · PAINTING
    § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND EAST WALL IN THE BATHROOM LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Jun 21, 2021Apt 3J
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOODEN FLOOR IN THE ENTIRE APARTMENT LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class CClosed
    Jun 21, 2021Apt 3J
    TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
    § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING AND EAST WALL IN THE BATHROOM LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Jun 18, 2021
    REMOVE ENCUMBRANCE · EGRESS
    § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES AIR CONDITIONER UNIT AT BALCONY REAR AT CENTER STACK AT FIRE ESCAPE, 4th STORY
    Class BClosed
    Jun 9, 2021
    REMOVE ENCUMBRANCE · EGRESS
    § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES AIR CONDITIONER UNIT PROTRUDING AT WINDOW INTO FIRE ESCAPE BALCONY AT REAR , 4th STORY
    Class AClosed
    Jun 9, 2021Apt 3J
    PAINT · PAINTING
    § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Jun 1, 2021Apt 3J
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR EAST AND WEST WALL IN THE BATHROOM LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Jun 1, 2021
    REMOVE ENCUMBRANCE · EGRESS
    § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES AIR CONDITIONER IN WINDOW PROTRUDING AT BALCONY 4TH STORY AT FIRE ESCAPE, 4th STORY
    Class AClosed
    Jun 1, 2021Apt 3J
    CLEANSE · CLEANING
    § 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE MOLD CERAMIC WALLS TILES IN THE BATHROOM LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Jun 1, 2021Apt 3J
    REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
    § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT EAST AND WEST WALL IN THE BATHROOM LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Jun 1, 2021
    REMOVE ACCUMULATION OR RUBBISH · CLEANING
    § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE FIRE PASSAGEWAY , 1st STORY
    Class CClosed
    Jun 1, 2021Apt 3J
    TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
    § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING APPROX 40 SQ FT IN THE BATHROOM LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed
    May 28, 2021Apt 6H
    TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
    § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT SOUTH WALL AAPPROXIMATELY 4 SQUARE FEET IN THE 1st ROOM FROM EAST LOCATED AT APT 6H, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 13944409 ISSUED 27-JAN-21 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).
    Class BClosed
    May 20, 2021Apt 3J
    REPAIR · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL GFCI OUTLETS AT NORTH WALL IN THE KITCHENETTE LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH , SECTION AT EAST
    Class CClosed
    May 20, 2021Apt 3J
    ABATE THE NUISANCE · MAINTENANCE
    § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF UNCAPPED GAS VALVE IN THE KITCHENETTE LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH , SECTION AT EAST
    Class BClosed
    May 20, 2021Apt 3J
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE (ROTTED) HARD WOOD FLOOR IN THE FOYER LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH , SECTION AT EAST
    Class BClosed
    May 20, 2021Apt 3J
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH , SECTION AT EAST
    Class BClosed
    May 20, 2021
    REMOVE ENCUMBRANCE · EGRESS
    § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES FLOWER PLANTER ON 3RD STY BALCONY AT 2ND FIRE ESCAPE FROM EAST AT BUILDING FRONT AT FIRE ESCAPE
    Class AClosed
    May 20, 2021Apt 3J
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE EAST WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH , SECTION AT EAST
    Class AClosed
    Apr 7, 2021
    POST SIGN INDICATING NAME AND ADDRESS OF JANITOR, ETC. · POSTING/SIGNAGE
    § 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORY
    Class BClosed
    Apr 7, 2021Apt 3J
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class CClosed
    Apr 7, 2021Apt 3J
    REPAIR · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER SASH WINDOW IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Apr 7, 2021Apt 3J
    REPAIR · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER SASH WINDOW IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class CClosed
    Feb 17, 2021Apt 6H
    ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATION
    HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 6H, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH
    Class CClosed
    Feb 17, 2021Apt 6H
    RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED
    § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE RADIATOR AIR VALVE IN THE 1st ROOM FROM EAST LOCATED AT APT 6H, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH
    Class AClosed
    Feb 17, 2021Apt 6H
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE EAST AND SOUTH WALLS IN THE 1st ROOM FROM EAST LOCATED AT APT 6H, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH
    Class CClosed
    Feb 17, 2021Apt 6E
    MAKE DOORS SELF-CLOSING · EGRESS
    § 27-2005, 2007, 204.1 HMC CODE: ARRANGE AND MAKE SELF-CLOSING THE DOORS .. IN THE ENTRANCE LOCATED AT APT 6E, 6th STORY, 5th APARTMENT FROM WEST AT NORTH
    Page 5 of 17