Class COpen
Nov 15, 2023Apt 23
CORRECT THE LEAD-BASED PAINT TESTED INCONCLUSIVE OR POSTIVE FOR METAL/CERAMIC SUBSTRATE · LEAD-BASED PAINT
§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD-PAINT THAT IS XRF TESTED INCONCLUSIVE FOR LEAD CONTENT AT 0.5MG/CM2 AND IS PRESUMED LEAD PAINT AS SET FORTH IN (28 RCNY §11-07(b)) AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE-USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(b)(2) 1st CLOSET FROM NORTH AT EAST WALL DOOR IN THE PRIVATE HALLWAY LOCATED AT APT 23, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH
Class COpen
Nov 15, 2023Apt 23
CORRECT THE LEAD-BASED PAINT TESTED INCONCLUSIVE OR POSTIVE FOR METAL/CERAMIC SUBSTRATE · LEAD-BASED PAINT
§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD-PAINT THAT IS XRF TESTED INCONCLUSIVE FOR LEAD CONTENT AT 0.5MG/CM2 AND IS PRESUMED LEAD PAINT AS SET FORTH IN (28 RCNY §11-07(b)) AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE-USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(b)(2) 1st DOOR FRAME FROM WEST AT NORTH WALL IN THE KITCHEN LOCATED AT APT 23, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH
Class COpen
Nov 15, 2023Apt 23
LEAD-BASED PAINT HAZARD- POSITIVE · LEAD-BASED PAINT
§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st CLOSET FROM NORTH AT EAST WALL DOOR FRAME IN THE PRIVATE HALLWAY LOCATED AT APT 23, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH
Class COpen
Nov 9, 2023Apt 12
CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD · LEAD-BASED PAINT
§ 27-2056.7, 27-2056.8, 27-2056.9 ADM CODE -CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY PERFORMING ACTIVITIES NECESSARY TO ABATE PRESUMED LEAD-BASED PAINT FROM REQUIRED WINDOW AND/OR DOOR FRICTION SURFACES FOR APARTMENT AND MAKE FLOORS SMOOTH AND CLEANABLE, PRESUMED LEAD PAINT IN AN APARTMENT WITH A CHILD UNDER SIX LOCATED AT APT 12, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BOpen
Oct 30, 2023Apt 15
REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 15, 1st STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BOpen
Oct 30, 2023Apt 15
REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 15, 1st STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class COpen
Oct 30, 2023Apt 26
ABATE THE NUISANCE · MAINTENANCE
§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK INSTALLED AT DOOR LEADING TO FIRE ESCAPE WINDOW IN THE 2nd ROOM FROM NORTH LOCATED AT APT 26, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''NORTH ''
Class COpen
Aug 30, 2023Apt 12
LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINT
§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING IN THE BATHROOM LOCATED AT APT 12, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
Class COpen
Aug 21, 2023Apt 23
LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINT
§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) NORTH WALL, SOUTH WALL IN THE FOYER LOCATED AT APT 23, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH
Class BOpen
Jan 17, 2023Apt 28
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 28, 2nd STORY, 3rd APARTMENT FROM EAST AT SOUTH , SECTION ''SOUTH''