stoop
MAP
LeaderboardAbout
Building SafetyHousing Conditions

351 WEST 125 STREET

Manhattan · ZIP 10027 · BIN 1059309 · Morningside Heights · Last violation Nov 16, 2026 · Last complaint Nov 12, 2026

NeighborhoodMorningside Heights
More violations than 99% of nearby buildings
More violations than 99% of buildings and more complaints than 98% of buildings in Morningside Heights. Size-normalized against residential buildings in the neighborhood for issues in the last 10 years.
ViolationsComplaints
Activity TrendsLast 5 years
More activity recently than in past years
Last 2 yrs: 586 violations · 540 complaints
'21'26ViolationsComplaints
▼ View all activity over time
Severityⓘopen violations
89 immediately hazardous (Class C) violations still open
Class C violations include lead paint, mold, pest infestations, heat/hot water failure, and structural hazards — the most serious category.
Class Cimmediately hazardous89Class Bhazardous220

What to watch forⓘ

  1. Hazardous violations are open, including mold and pests, and building maintenance.
    Worth checking · AI-assistedⓘ
    Look along the baseboards and floor corners for droppings, dead insects, or sticky traps. Check cabinet and closet surfaces, pipes, and walls for water stains, peeling paint, or soft spots.
    details ▸

    Deadlines vary by condition: immediate for heat and hot water, 14 days for self-closing doors, 21 days for lead paint, window guards, mold, and mice, cockroaches or rats, and 24 hours for everything else. They run from the date the owner is served, and mark when civil penalties can be sought in Housing Court. They are not a promise the condition is fixed by then. If the owner does not fix it, HPD can send its own contractor and bill them.

    • —Mold & pests — Rodent, cockroach, bedbug, or other pest infestation and extermination related issues.
    • —Bldg maintenance — General building repair, upkeep, and maintenance related housing code violations.

    The violation list below shows which conditions are open and when each was cited. If one in your own apartment is still unaddressed, call 311.

    • ABCs of Housing
Housing Preservation & Development Violations
Total violations since 2007
1,482
74 per year avg.↑ Up 78% in the last 2 years (586 vs 329 prior 2 yrs)
Open violations
395
Class C (immed. haz.)ⓘ89
Class B (hazardous)ⓘ220
Rent-impairingⓘ24
Housing Preservation & Development Complaints
Total complaints since 2004
1,410
61 per year avg.↑ Up 151% in the last 2 years (540 vs 215 prior 2 yrs)
Complaint Resolution
No access15%Violation issued29%No violation39%Phone resolved18%Other0%(1,410)
Urgency breakdown
Last 12 mo.

Top violation categories

5 yrsAll time
Maintenanceⓘ445 violations
Paintingⓘ109 violations
Extermination & Rodent Eradicationⓘ67 violations
Water Supplyⓘ66 violations
Lead-Based Paintⓘ60 violations
Heat And Hot Waterⓘ43 violations
Egressⓘ43 violations
Cleaningⓘ40 violations
Top complaint groupsⓘ
5 yrsAll time
Bldg maintenanceⓘ176 complaints
Heat / hot waterⓘ175 complaints
Mold & pestsⓘ123 complaints
Water & plumbingⓘ121 complaints
Electricalⓘ45 complaints
Appliancesⓘ16 complaints
Safety & fireⓘ13 complaints
Elevatorⓘ3 complaints
Adminⓘ3 complaints
Outdoor / structuralⓘ1 complaints
Hide violations ↑See complaints →

Violation log

832 violations · Class B

All classesClass AClass BClass CClass IAllOpenClosed
ClassStatusApt
See something wrong? File a complaint with 311
  • NYC HPD, Penalties and Fees
  • Heat or hot water problems reported in the last five years.
    Worth checking · AI-assistedⓘ
    Turn on hot water at the kitchen sink and bathroom sink and feel the water temperature after running for one minute.
    details ▸

    Heat is required October 1 through May 31: at least 68°F from 6am to 10pm when it is below 55°F outside, and 62°F overnight whatever the temperature outside. Hot water must be at least 120°F, 24 hours a day, all year.

    If your apartment is colder than that, file a complaint with 311 and keep the service request number so you can track it. Never use a gas oven or range for heat, which can produce dangerous levels of carbon monoxide.

    • ABCs of Housing
  • Lead-paint violations on record.
    Worth checking · AI-assistedⓘ
    Look for paint that is peeling, chipped, or cracked on interior walls, trim, windows, doors, and door frames.
    details ▸

    Buildings built before 1960 may still contain lead-based paint, which causes behavioral and learning problems in young children, who can swallow dust and paint chips from windowsills and floors.

    If a child under six lives with you, or spends 10 or more hours a week in your apartment, tell the owner in writing, which is what obliges them to inspect annually. Report peeling paint, and call 311 if it is not fixed or if repair work is raising dust that is not being contained.

    • ABCs of Housing
  • Open violation ages
    ▪ < 30 days15% (57)
    ▪ 30–90 days1% (4)
    ▪ 3–12 months24% (94)
    ▪ 1–3 years52% (204)
    ▪ 3+ years8% (30)
    Prior 4 yr.
    Immed. Emergency2%3%
    Emergency47%48%
    Non-Emergency52%49%
    (384)
    (409)
    Issued
    Description
    Class BClosedRENT IMPAIRING—Jun 4, 2024REMOVE ENCUMBRANCES · EGRESS§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEM(MATTRESS) AT PUBLIC HALL, 1st STORY
    Class BOpen—Jun 4, 2024REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEIILING AND NORTH WALL AT PUBLIC HALL, 6th STORY
    Class BClosedRENT IMPAIRING35Jun 4, 2024REMOVE OBSTRUCTIONS · SEWERS AND DRAINAGE§ 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN AT SHOWER DRAIN IN THE BATHROOM LOCATED AT APT 35, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed41Apr 26, 2024REPAIR LEAKY FAUCETS · WATER SUPPLY§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 41, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH
    Class BClosed47Apr 5, 2024REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL LIGHT FIXTURE AT CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 47, 4th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BClosed—Apr 5, 2024REMOVE ENCUMBRANCE · EGRESS§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES AIR CONDITIONER POTURDING APPROXIMATELY MORE THAN 4 INCHES BEYOND WINDOW SILL AT 2ND STORY BALCONY AT WEST EXTERIOR WALL AT FIRE ESCAPE
    Class BOpen65Mar 14, 2024TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROXIMATELY 1 SQ.FT AT WINDOW JAMB, 1 SQ.FT AT WINDOW CASING AND 1 SQ.FT AT THE CEILING IN THE BATHROOM LOCATED AT APT 65, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 16378838 ISSUED 13-NOV-23 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).
    Class BClosed65Jan 23, 2024TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 4 SQFT AT THE WINDOW FRAME FROM NORTH AT EAST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 65, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 16243169 ISSUED 21-SEP-23 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).
    Class BOpen65Jan 23, 2024TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 6 SQ FT AT THE EAST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 65, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 16243165 ISSUED 21-SEP-23 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).
    Class BClosed65Jan 23, 2024TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 6 SQ FT AT THE CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 65, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 16243167 ISSUED 21-SEP-23 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).
    Class BClosed65Jan 23, 2024TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 4 SQ FT AT THE WINDOW FRAME FROM WEST AT NORTH WALL IN THE BATHROOM LOCATED AT APT 65, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 16243170 ISSUED 21-SEP-23 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).
    Class BClosed55Jan 15, 2024REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT 55, 5th STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosedRENT IMPAIRING31Jan 15, 2024INADEQUATE HOT WATER SUPPLY (VOLUME) · WATER SUPPLY§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT BATHTUB IN THE BATHROOM LOCATED AT APT 31, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH
    Class BClosed55Jan 15, 2024REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 55, 5th STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed53Jan 4, 2024REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT APT 53, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen53Jan 4, 2024REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 53, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen53Jan 4, 2024REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT FLOOR, NORTH WALL, AND WEST WALL, IN THE BATHROOM LOCATED AT APT 53, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen53Jan 4, 2024REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND SOUTH WALL IN THE KITCHEN LOCATED AT APT 53, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen53Jan 4, 2024REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR IN THE KITCHEN LOCATED AT APT 53, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen53Jan 4, 2024REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND NORTH WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 53, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen53Jan 4, 2024REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL WALLS IN THE FOYER LOCATED AT APT 53, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosed53Jan 4, 2024REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE UPPER SASH WINDOW SPRING BALANCE, 2ND WINDOW FROM EAST AT SOUTH IN THE 5th ROOM FROM NORTH AT WEST LOCATED AT APT 53, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen53Jan 4, 2024REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 53, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosed53Jan 4, 2024REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL WALLS IN THE 5th ROOM FROM NORTH AT WEST LOCATED AT APT 53, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen53Jan 4, 2024REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND NORTH WALL IN THE 5th ROOM FROM EAST AT SOUTH LOCATED AT APT 53, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosed65Dec 14, 2023TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROXIMATELY 6 SQ FT AT NORTH WALL WINDOW FRAME FROM WEST AT NORTH WALL IN THE BATHROOM LOCATED AT APT 65, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 16159411 ISSUED 14-AUG-23 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).
    Class BClosed31Dec 8, 2023REPAIR LEAKY FAUCETS · WATER SUPPLY§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 31, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH
    Class BClosed66Nov 29, 2023REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 2nd ROOM FROM NORTH LOCATED AT APT 66, 6th STORY, 4th APARTMENT FROM WEST AT NORTH
    Class BOpen65Nov 15, 2023REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR NEAR RADIATOR IN THE 4th ROOM FROM NORTH AT WEST LOCATED AT APT 65, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed25Oct 30, 2023REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 25, 2nd STORY, 3rd APARTMENT FROM WEST AT NORTH
    Class BClosed25Oct 30, 2023REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 25, 2nd STORY, 3rd APARTMENT FROM WEST AT NORTH
    Class BClosed65Sep 25, 2023REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 65, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosedRENT IMPAIRING65Sep 25, 2023LEAKY ROOF · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK ABOVE THE CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 65, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BOpen65Sep 25, 2023REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 4th ROOM FROM NORTH AT WEST LOCATED AT APT 65, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed65Sep 25, 2023REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 65, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed25Aug 28, 2023REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SINK BASE CABINET IN THE KITCHEN LOCATED AT APT 25, 2nd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed25Aug 23, 2023REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 25, 2nd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed25Aug 23, 2023REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE RUBBER GASKETS LOWER AND UPPER REFREGERATOR DOORS IN THE KITCHEN LOCATED AT APT 25, 2nd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed25Aug 23, 2023REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 25, 2nd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BOpen25Aug 23, 2023REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT 25, 2nd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed25Aug 23, 2023REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ENTRANCE DOOR IN THE 2nd ROOM FROM NORTH LOCATED AT APT 25, 2nd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed37Aug 23, 2023REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 37, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BClosed37Aug 23, 2023REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 37, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BClosed25Aug 23, 2023REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 25, 2nd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed25Aug 23, 2023REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WOOD FLOOR AROUND RADIATOR IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT 25, 2nd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed25Aug 23, 2023PROVIDE SUPPLY OF ELECTRICTY TO FIXTURES · ARTIFICIAL LIGHTING§ 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING IN THE BATHROOM LOCATED AT APT 25, 2nd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed—Aug 21, 2023REMOVE ENCUMBRANCE · EGRESS§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES A/C PROTRUDING AT 1ST AND 3RD BALCONY AT REAR WEST FIRE ESCAPE
    Class BClosed62Aug 21, 2023REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 62, 6th STORY, 3rd APARTMENT FROM WEST AT NORTH
    Class BClosed62Aug 21, 2023REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 62, 6th STORY, 3rd APARTMENT FROM WEST AT NORTH
    Class BClosed57Aug 21, 2023REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 57, 5th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BClosedRENT IMPAIRING
    Jun 4, 2024
    REMOVE ENCUMBRANCES · EGRESS
    § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEM(MATTRESS) AT PUBLIC HALL, 1st STORY
    Class BOpen
    Jun 4, 2024
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEIILING AND NORTH WALL AT PUBLIC HALL, 6th STORY
    Class BClosedRENT IMPAIRING
    Jun 4, 2024Apt 35
    REMOVE OBSTRUCTIONS · SEWERS AND DRAINAGE
    § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN AT SHOWER DRAIN IN THE BATHROOM LOCATED AT APT 35, 3rd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Apr 26, 2024Apt 41
    REPAIR LEAKY FAUCETS · WATER SUPPLY
    § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 41, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH
    Class BClosed
    Apr 5, 2024Apt 47
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL LIGHT FIXTURE AT CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 47, 4th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BClosed
    Apr 5, 2024
    REMOVE ENCUMBRANCE · EGRESS
    § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES AIR CONDITIONER POTURDING APPROXIMATELY MORE THAN 4 INCHES BEYOND WINDOW SILL AT 2ND STORY BALCONY AT WEST EXTERIOR WALL AT FIRE ESCAPE
    Class BOpen
    Mar 14, 2024Apt 65
    TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
    § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROXIMATELY 1 SQ.FT AT WINDOW JAMB, 1 SQ.FT AT WINDOW CASING AND 1 SQ.FT AT THE CEILING IN THE BATHROOM LOCATED AT APT 65, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 16378838 ISSUED 13-NOV-23 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).
    Class BClosed
    Jan 23, 2024Apt 65
    TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
    § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 4 SQFT AT THE WINDOW FRAME FROM NORTH AT EAST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 65, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 16243169 ISSUED 21-SEP-23 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).
    Class BOpen
    Jan 23, 2024Apt 65
    TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
    § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 6 SQ FT AT THE EAST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 65, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 16243165 ISSUED 21-SEP-23 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).
    Class BClosed
    Jan 23, 2024Apt 65
    TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
    § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 6 SQ FT AT THE CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 65, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 16243167 ISSUED 21-SEP-23 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).
    Class BClosed
    Jan 23, 2024Apt 65
    TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
    § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 4 SQ FT AT THE WINDOW FRAME FROM WEST AT NORTH WALL IN THE BATHROOM LOCATED AT APT 65, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 16243170 ISSUED 21-SEP-23 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).
    Class BClosed
    Jan 15, 2024Apt 55
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT 55, 5th STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosedRENT IMPAIRING
    Jan 15, 2024Apt 31
    INADEQUATE HOT WATER SUPPLY (VOLUME) · WATER SUPPLY
    § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT BATHTUB IN THE BATHROOM LOCATED AT APT 31, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH
    Class BClosed
    Jan 15, 2024Apt 55
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 55, 5th STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Jan 4, 2024Apt 53
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT APT 53, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Jan 4, 2024Apt 53
    REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
    § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 53, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Jan 4, 2024Apt 53
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT FLOOR, NORTH WALL, AND WEST WALL, IN THE BATHROOM LOCATED AT APT 53, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Jan 4, 2024Apt 53
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND SOUTH WALL IN THE KITCHEN LOCATED AT APT 53, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Jan 4, 2024Apt 53
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR IN THE KITCHEN LOCATED AT APT 53, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Jan 4, 2024Apt 53
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND NORTH WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 53, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Jan 4, 2024Apt 53
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL WALLS IN THE FOYER LOCATED AT APT 53, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Jan 4, 2024Apt 53
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE UPPER SASH WINDOW SPRING BALANCE, 2ND WINDOW FROM EAST AT SOUTH IN THE 5th ROOM FROM NORTH AT WEST LOCATED AT APT 53, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Jan 4, 2024Apt 53
    REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
    § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 53, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Jan 4, 2024Apt 53
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL WALLS IN THE 5th ROOM FROM NORTH AT WEST LOCATED AT APT 53, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Jan 4, 2024Apt 53
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND NORTH WALL IN THE 5th ROOM FROM EAST AT SOUTH LOCATED AT APT 53, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Dec 14, 2023Apt 65
    TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
    § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROXIMATELY 6 SQ FT AT NORTH WALL WINDOW FRAME FROM WEST AT NORTH WALL IN THE BATHROOM LOCATED AT APT 65, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 16159411 ISSUED 14-AUG-23 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).
    Class BClosed
    Dec 8, 2023Apt 31
    REPAIR LEAKY FAUCETS · WATER SUPPLY
    § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 31, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH
    Class BClosed
    Nov 29, 2023Apt 66
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 2nd ROOM FROM NORTH LOCATED AT APT 66, 6th STORY, 4th APARTMENT FROM WEST AT NORTH
    Class BOpen
    Nov 15, 2023Apt 65
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR NEAR RADIATOR IN THE 4th ROOM FROM NORTH AT WEST LOCATED AT APT 65, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Oct 30, 2023Apt 25
    REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
    § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 25, 2nd STORY, 3rd APARTMENT FROM WEST AT NORTH
    Class BClosed
    Oct 30, 2023Apt 25
    REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
    § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 25, 2nd STORY, 3rd APARTMENT FROM WEST AT NORTH
    Class BClosed
    Sep 25, 2023Apt 65
    REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
    § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 65, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosedRENT IMPAIRING
    Sep 25, 2023Apt 65
    LEAKY ROOF · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK ABOVE THE CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 65, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Sep 25, 2023Apt 65
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 4th ROOM FROM NORTH AT WEST LOCATED AT APT 65, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Sep 25, 2023Apt 65
    REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
    § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 65, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Aug 28, 2023Apt 25
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SINK BASE CABINET IN THE KITCHEN LOCATED AT APT 25, 2nd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Aug 23, 2023Apt 25
    REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
    § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 25, 2nd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Aug 23, 2023Apt 25
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE RUBBER GASKETS LOWER AND UPPER REFREGERATOR DOORS IN THE KITCHEN LOCATED AT APT 25, 2nd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Aug 23, 2023Apt 25
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 25, 2nd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Aug 23, 2023Apt 25
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT 25, 2nd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Aug 23, 2023Apt 25
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ENTRANCE DOOR IN THE 2nd ROOM FROM NORTH LOCATED AT APT 25, 2nd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Aug 23, 2023Apt 37
    REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
    § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 37, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BClosed
    Aug 23, 2023Apt 37
    REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
    § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 37, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BClosed
    Aug 23, 2023Apt 25
    REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
    § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 25, 2nd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Aug 23, 2023Apt 25
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WOOD FLOOR AROUND RADIATOR IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT 25, 2nd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Aug 23, 2023Apt 25
    PROVIDE SUPPLY OF ELECTRICTY TO FIXTURES · ARTIFICIAL LIGHTING
    § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING IN THE BATHROOM LOCATED AT APT 25, 2nd STORY, 3rd APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Aug 21, 2023
    REMOVE ENCUMBRANCE · EGRESS
    § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES A/C PROTRUDING AT 1ST AND 3RD BALCONY AT REAR WEST FIRE ESCAPE
    Class BClosed
    Aug 21, 2023Apt 62
    REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
    § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 62, 6th STORY, 3rd APARTMENT FROM WEST AT NORTH
    Class BClosed
    Aug 21, 2023Apt 62
    REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
    § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 62, 6th STORY, 3rd APARTMENT FROM WEST AT NORTH
    Class BClosed
    Aug 21, 2023Apt 57
    REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
    § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 57, 5th STORY, 1st APARTMENT FROM WEST AT NORTH
    Page 8 of 17
    ← PrevNext →