stoop
MAP
LeaderboardAbout
Building SafetyHousing Conditions

107 EAST 126 STREET

Manhattan · ZIP 10035 · BIN 1054496 · East Harlem (North) · Last violation Oct 1, 2026 · Last complaint Sep 28, 2026

NeighborhoodEast Harlem (North)
More violations than 92% of nearby buildings
More violations than 92% of buildings and more complaints than 92% of buildings in East Harlem (North). Size-normalized against residential buildings in the neighborhood for issues in the last 10 years.
ViolationsComplaints
Activity TrendsLast 5 years
A steady level of activity over time
Last 2 yrs: 799 violations · 952 complaints
'21'26ViolationsComplaints
▼ View all activity over time
Severityⓘopen violations
154 immediately hazardous (Class C) violations still open
Class C violations include lead paint, mold, pest infestations, heat/hot water failure, and structural hazards — the most serious category.
Class Cimmediately hazardous154Class Bhazardous264

What to watch forⓘ

  1. Hazardous violations are open, including mold and pests, and building maintenance.
    Worth checking · AI-assistedⓘ
    Look along the baseboards and floor corners for droppings, dead insects, or sticky traps. Check cabinet and closet surfaces, pipes, and walls for water stains, peeling paint, or soft spots.
    details ▸

    Deadlines vary by condition: immediate for heat and hot water, 14 days for self-closing doors, 21 days for lead paint, window guards, mold, and mice, cockroaches or rats, and 24 hours for everything else. They run from the date the owner is served, and mark when civil penalties can be sought in Housing Court. They are not a promise the condition is fixed by then. If the owner does not fix it, HPD can send its own contractor and bill them.

    • —Mold & pests — Rodent, cockroach, bedbug, or other pest infestation and extermination related issues.
    • —Bldg maintenance — General building repair, upkeep, and maintenance related housing code violations.

    The violation list below shows which conditions are open and when each was cited. If one in your own apartment is still unaddressed, call 311.

    • ABCs of Housing
Housing Preservation & Development Violations
Total violations since 2009
3,166
176 per year avg.→ Stable in the last 2 years
Open violations
463
Class C (immed. haz.)ⓘ154
Class B (hazardous)ⓘ264
Rent-impairingⓘ11
Housing Preservation & Development Complaints
Total complaints since 2003
4,983
208 per year avg.↑ Up 15% in the last 2 years (952 vs 828 prior 2 yrs)
Complaint Resolution
No access18%Violation issued28%No violation37%Phone resolved15%Other1%(4,983)
Urgency breakdown
Last 12 mo.

Top violation categories

5 yrsAll time
Maintenanceⓘ609 violations
Extermination & Rodent Eradicationⓘ371 violations
Cleaningⓘ222 violations
Water Supplyⓘ173 violations
Egressⓘ128 violations
Smoke Detecting Devicesⓘ62 violations
Paintingⓘ61 violations
Carbon Monoxide Detecting Devicesⓘ60 violations
Top complaint groupsⓘ
5 yrsAll time
Mold & pestsⓘ679 complaints
Water & plumbingⓘ401 complaints
Heat / hot waterⓘ350 complaints
Bldg maintenanceⓘ300 complaints
Safety & fireⓘ94 complaints
Electricalⓘ52 complaints
Appliancesⓘ47 complaints
Outdoor / structuralⓘ1 complaints
Hide violations ↑See complaints →

Violation log

1,686 violations · Class B

All classesClass AClass BClass CClass IAllOpenClosed
ClassStatusApt
See something wrong? File a complaint with 311
  • NYC HPD, Penalties and Fees
  • Heat or hot water problems reported in the last five years.
    Worth checking · AI-assistedⓘ
    Turn on hot water at the kitchen sink and bathroom sink and feel the water temperature after running for one minute.
    details ▸

    Heat is required October 1 through May 31: at least 68°F from 6am to 10pm when it is below 55°F outside, and 62°F overnight whatever the temperature outside. Hot water must be at least 120°F, 24 hours a day, all year.

    If your apartment is colder than that, file a complaint with 311 and keep the service request number so you can track it. Never use a gas oven or range for heat, which can produce dangerous levels of carbon monoxide.

    • ABCs of Housing
  • Detector violations on record.
    Worth checking · AI-assistedⓘ
    Locate smoke detectors on the ceiling near bedrooms and in hallways, and ask the broker whether carbon monoxide detectors are present in the unit.
    details ▸

    Responsibility is split: the owner provides, installs, and replaces the detectors, while the tenant tests them monthly and replaces the batteries. An open violation means the owner has not yet certified to HPD that the condition was fixed, so a device may still be missing or dead at move-in. A tenant reimburses the owner for a newly installed device, $25 for a smoke or carbon monoxide detector and $50 for a combined unit, and is responsible for replacing one that goes missing or is damaged during the tenancy.

    On a viewing, look for a smoke alarm within fifteen feet of the door of each room used for sleeping, on the ceiling or just below it on the wall, and a carbon monoxide alarm at any height, including one plugged into a hallway outlet. Press the test button, and check that none have been painted over. A chirping alarm usually means a low battery, which is the tenant's to replace, but detectors also sound a separate end-of-life alarm when the device itself has to be replaced by the owner.

    • ABCs of Housing
    • NYC HPD, Smoke, Carbon Monoxide, and Natural Gas Detectors
  • Open violation ages
    ▪ < 30 days1% (5)
    ▪ 30–90 days9% (40)
    ▪ 3–12 months46% (215)
    ▪ 1–3 years33% (155)
    ▪ 3+ years10% (48)
    Prior 4 yr.
    Immed. Emergency4%3%
    Emergency49%47%
    Non-Emergency47%50%
    (451)
    (1,774)
    Issued
    Description
    Class BOpen7VMar 24, 2026REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 7V, 7th STORY, 2nd APARTMENT FROM NORTH AT EAST
    Class BClosed4CMar 24, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WEST WALL IN THE BATHROOM LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class BOpen11TMar 24, 2026REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 11T, 11th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen11TMar 24, 2026REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 11T, 11th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen11TMar 24, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 4th ROOM FROM NORTH LOCATED AT APT 11T, 11th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen11TMar 24, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WEST WALL IN THE KITCHEN LOCATED AT APT 11T, 11th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen7VMar 24, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 7V, 7th STORY, 2nd APARTMENT FROM NORTH AT EAST
    Class BOpen11TMar 24, 2026REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 11T, 11th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosed4CMar 24, 2026REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT WEST WALL IN THE BATHROOM LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class BOpen11TMar 24, 2026REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT WEST WALL IN THE BATHROOM LOCATED AT APT 11T, 11th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosed4CMar 24, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING, EAST AND SOUTH WALLS IN THE KITCHEN LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class BClosed10EMar 24, 2026REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 10E, 2nd APARTMENT FROM EAST AT SOUTH
    Class BOpen11TMar 24, 2026REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 11T, 11th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosed10EMar 24, 2026REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 10E, 2nd APARTMENT FROM EAST AT SOUTH
    Class BOpen7VMar 24, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING, NORTH AND WEST WALLS IN THE KITCHEN LOCATED AT APT 7V, 7th STORY, 2nd APARTMENT FROM NORTH AT EAST
    Class BOpen7VMar 24, 2026REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING, NORTH AND WEST WALLS IN THE KITCHEN LOCATED AT APT 7V, 7th STORY, 2nd APARTMENT FROM NORTH AT EAST
    Class BOpen7VMar 12, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 7V, 7th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''EAST''
    Class BOpen7VMar 12, 2026REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 7V, 7th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''EAST''
    Class BOpen7VMar 12, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND NORTH WALL IN THE KITCHEN LOCATED AT APT 7V, 7th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''EAST''
    Class BOpen7VMar 12, 2026REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AND NORTH WALL IN THE KITCHEN LOCATED AT APT 7V, 7th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''EAST''
    Class BClosed8AMar 9, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WEST WALL AND CEILING IN THE BATHROOM LOCATED AT APT 8A, 8th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BClosed8AMar 9, 2026REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT EAST AND SOUTH WALLS IN THE PRIVATE HALLWAY LOCATED AT APT 8A, 8th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BClosed8AMar 9, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST AND SOUTH WALLS IN THE PRIVATE HALLWAY LOCATED AT APT 8A, 8th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BClosed8AMar 9, 2026REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT WEST WALL AND CEILING IN THE BATHROOM LOCATED AT APT 8A, 8th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BClosed8AMar 9, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH AND WEST WALLS IN THE 1st ROOM FROM NORTH AT CENTER LOCATED AT APT 8A, 8th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BClosed10EFeb 23, 2026REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AND EAST WALL IN THE BATHROOM LOCATED AT APT 10E, 10th STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''WEST''
    Class BClosed8AFeb 23, 2026REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC-TILES FLOOR IN THE 3rd ROOM FROM NORTH LOCATED AT APT 8A, 8th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''EAST''
    Class BClosed10EFeb 23, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND EAST WALL IN THE BATHROOM LOCATED AT APT 10E, 10th STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''WEST''
    Class BClosed10EFeb 23, 2026REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT EAST WALL AND CEILING IN THE KITCHEN LOCATED AT APT 10E, 10th STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''WEST''
    Class BOpen10EFeb 23, 2026TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MORE THEN 10 SQFT AT CEILING AND EAST WALL IN THE BATHROOM LOCATED AT APT 10E, 10th STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''WEST''
    Class BClosed8AFeb 23, 2026TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MORE THAN 10 SQUARE FEET AT NORTH WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 8A, 8th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''EAST''
    Class BClosed10EFeb 23, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL AND CEILING IN THE KITCHEN LOCATED AT APT 10E, 10th STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''WEST''
    Class BOpen10HFeb 23, 2026REFIT DOORS ETC. · EGRESS§ 27-2005 HMC: REFIT THE ENTRANCE DOOR IN THE BATHROOM LOCATED AT APT 10H, 10th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''WEST''
    Class BOpen11OFeb 11, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND CEILING IN THE BATHROOM LOCATED AT APT 11O, 11th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BOpen11OFeb 11, 2026REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT NORTH WALL IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 11O, 11th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BOpen11OFeb 11, 2026SECURE LOOSE MATTER · MAINTENANCE§ 27-2005 ADM CODE PROPERLY SECURE THE LOOSE RADIATOR COVER AT NORTH WALL IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 11O, 11th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BOpen11OFeb 11, 2026TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10 SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 11O, 11th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BOpen11OFeb 11, 2026REFIT DOORS ETC. · EGRESS§ 27-2005 HMC: REFIT WOODEN DOOR AT ENTRANCE IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 11O, 11th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BOpen11OFeb 11, 2026REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BELL/BUZZER INTERCOM SYSTEM FROM BUILDING ENTRANCE TO PANEL AT WEST WALL IN THE PRIVATE HALLWAY LOCATED AT APT 11O, 11th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BOpen11OFeb 11, 2026REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 11O, 11th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BOpen11OFeb 11, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR NORTH WALL IN THE 1st ROOM FROM NORTH AT CENTER LOCATED AT APT 11O, 11th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BOpen11OFeb 11, 2026REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 11O, 11th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BOpenRENT IMPAIRING11OFeb 11, 2026INADEQUATE HOT WATER SUPPLY (VOLUME) · WATER SUPPLY§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT SINK IN THE KITCHEN LOCATED AT APT 11O, 11th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BOpen11OFeb 11, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR EAST WALL IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 11O, 11th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BClosed9SFeb 6, 2026TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT CEILING IN THE 2nd BATHROOM FROM EAST LOCATED AT APT 9S, 9th STORY, 2nd APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 18273727 ISSUED 05-OCT-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017.3a(3)(a) or (b).
    Class BClosed3UJan 20, 2026REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 3U, 3rd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class BOpen3UJan 20, 2026TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 20 SQ FT AT CEILING AND NORTH, EAST, WEST AND SOUTH WALLS IN THE BATHROOM LOCATED AT APT 3U, 3rd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class BClosed3UJan 20, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 3U, 3rd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class BOpen8SJan 16, 2026TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT NORTH WALL IN THE BATHROOM LOCATED AT APT 8S, 8th STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION AT EAST ORIGINAL VIOLATION 18243940 ISSUED 12-SEP-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017.3a(3)(a) or (b).
    Class BOpen11TJan 15, 2026REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 11T, 11th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Mar 24, 2026Apt 7V
    REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
    § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 7V, 7th STORY, 2nd APARTMENT FROM NORTH AT EAST
    Class BClosed
    Mar 24, 2026Apt 4C
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WEST WALL IN THE BATHROOM LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class BOpen
    Mar 24, 2026Apt 11T
    REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
    § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 11T, 11th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Mar 24, 2026Apt 11T
    REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
    § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 11T, 11th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Mar 24, 2026Apt 11T
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 4th ROOM FROM NORTH LOCATED AT APT 11T, 11th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Mar 24, 2026Apt 11T
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WEST WALL IN THE KITCHEN LOCATED AT APT 11T, 11th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Mar 24, 2026Apt 7V
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 7V, 7th STORY, 2nd APARTMENT FROM NORTH AT EAST
    Class BOpen
    Mar 24, 2026Apt 11T
    REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
    § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 11T, 11th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Mar 24, 2026Apt 4C
    REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
    § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT WEST WALL IN THE BATHROOM LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class BOpen
    Mar 24, 2026Apt 11T
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT WEST WALL IN THE BATHROOM LOCATED AT APT 11T, 11th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Mar 24, 2026Apt 4C
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING, EAST AND SOUTH WALLS IN THE KITCHEN LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class BClosed
    Mar 24, 2026Apt 10E
    REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
    § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 10E, 2nd APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Mar 24, 2026Apt 11T
    REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
    § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 11T, 11th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Class BClosed
    Mar 24, 2026Apt 10E
    REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
    § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 10E, 2nd APARTMENT FROM EAST AT SOUTH
    Class BOpen
    Mar 24, 2026Apt 7V
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING, NORTH AND WEST WALLS IN THE KITCHEN LOCATED AT APT 7V, 7th STORY, 2nd APARTMENT FROM NORTH AT EAST
    Class BOpen
    Mar 24, 2026Apt 7V
    REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
    § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING, NORTH AND WEST WALLS IN THE KITCHEN LOCATED AT APT 7V, 7th STORY, 2nd APARTMENT FROM NORTH AT EAST
    Class BOpen
    Mar 12, 2026Apt 7V
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 7V, 7th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''EAST''
    Class BOpen
    Mar 12, 2026Apt 7V
    REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
    § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 7V, 7th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''EAST''
    Class BOpen
    Mar 12, 2026Apt 7V
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND NORTH WALL IN THE KITCHEN LOCATED AT APT 7V, 7th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''EAST''
    Class BOpen
    Mar 12, 2026Apt 7V
    REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
    § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AND NORTH WALL IN THE KITCHEN LOCATED AT APT 7V, 7th STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''EAST''
    Class BClosed
    Mar 9, 2026Apt 8A
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WEST WALL AND CEILING IN THE BATHROOM LOCATED AT APT 8A, 8th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BClosed
    Mar 9, 2026Apt 8A
    REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
    § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT EAST AND SOUTH WALLS IN THE PRIVATE HALLWAY LOCATED AT APT 8A, 8th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BClosed
    Mar 9, 2026Apt 8A
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST AND SOUTH WALLS IN THE PRIVATE HALLWAY LOCATED AT APT 8A, 8th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BClosed
    Mar 9, 2026Apt 8A
    REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
    § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT WEST WALL AND CEILING IN THE BATHROOM LOCATED AT APT 8A, 8th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BClosed
    Mar 9, 2026Apt 8A
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH AND WEST WALLS IN THE 1st ROOM FROM NORTH AT CENTER LOCATED AT APT 8A, 8th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BClosed
    Feb 23, 2026Apt 10E
    REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
    § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AND EAST WALL IN THE BATHROOM LOCATED AT APT 10E, 10th STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''WEST''
    Class BClosed
    Feb 23, 2026Apt 8A
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC-TILES FLOOR IN THE 3rd ROOM FROM NORTH LOCATED AT APT 8A, 8th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''EAST''
    Class BClosed
    Feb 23, 2026Apt 10E
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND EAST WALL IN THE BATHROOM LOCATED AT APT 10E, 10th STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''WEST''
    Class BClosed
    Feb 23, 2026Apt 10E
    REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
    § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT EAST WALL AND CEILING IN THE KITCHEN LOCATED AT APT 10E, 10th STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''WEST''
    Class BOpen
    Feb 23, 2026Apt 10E
    TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
    § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MORE THEN 10 SQFT AT CEILING AND EAST WALL IN THE BATHROOM LOCATED AT APT 10E, 10th STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''WEST''
    Class BClosed
    Feb 23, 2026Apt 8A
    TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
    § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MORE THAN 10 SQUARE FEET AT NORTH WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 8A, 8th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''EAST''
    Class BClosed
    Feb 23, 2026Apt 10E
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL AND CEILING IN THE KITCHEN LOCATED AT APT 10E, 10th STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''WEST''
    Class BOpen
    Feb 23, 2026Apt 10H
    REFIT DOORS ETC. · EGRESS
    § 27-2005 HMC: REFIT THE ENTRANCE DOOR IN THE BATHROOM LOCATED AT APT 10H, 10th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''WEST''
    Class BOpen
    Feb 11, 2026Apt 11O
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND CEILING IN THE BATHROOM LOCATED AT APT 11O, 11th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BOpen
    Feb 11, 2026Apt 11O
    REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
    § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT NORTH WALL IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 11O, 11th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BOpen
    Feb 11, 2026Apt 11O
    SECURE LOOSE MATTER · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE RADIATOR COVER AT NORTH WALL IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 11O, 11th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BOpen
    Feb 11, 2026Apt 11O
    TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
    § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10 SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 11O, 11th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BOpen
    Feb 11, 2026Apt 11O
    REFIT DOORS ETC. · EGRESS
    § 27-2005 HMC: REFIT WOODEN DOOR AT ENTRANCE IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 11O, 11th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BOpen
    Feb 11, 2026Apt 11O
    REPAIR · MAINTENANCE
    § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BELL/BUZZER INTERCOM SYSTEM FROM BUILDING ENTRANCE TO PANEL AT WEST WALL IN THE PRIVATE HALLWAY LOCATED AT APT 11O, 11th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BOpen
    Feb 11, 2026Apt 11O
    REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
    § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 11O, 11th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BOpen
    Feb 11, 2026Apt 11O
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR NORTH WALL IN THE 1st ROOM FROM NORTH AT CENTER LOCATED AT APT 11O, 11th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BOpen
    Feb 11, 2026Apt 11O
    REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
    § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 11O, 11th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BOpenRENT IMPAIRING
    Feb 11, 2026Apt 11O
    INADEQUATE HOT WATER SUPPLY (VOLUME) · WATER SUPPLY
    § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT SINK IN THE KITCHEN LOCATED AT APT 11O, 11th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BOpen
    Feb 11, 2026Apt 11O
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR EAST WALL IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 11O, 11th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class BClosed
    Feb 6, 2026Apt 9S
    TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
    § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT CEILING IN THE 2nd BATHROOM FROM EAST LOCATED AT APT 9S, 9th STORY, 2nd APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 18273727 ISSUED 05-OCT-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017.3a(3)(a) or (b).
    Class BClosed
    Jan 20, 2026Apt 3U
    REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
    § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 3U, 3rd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class BOpen
    Jan 20, 2026Apt 3U
    TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
    § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 20 SQ FT AT CEILING AND NORTH, EAST, WEST AND SOUTH WALLS IN THE BATHROOM LOCATED AT APT 3U, 3rd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class BClosed
    Jan 20, 2026Apt 3U
    REPAIR PLASTER · MAINTENANCE
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 3U, 3rd STORY, 3rd APARTMENT FROM NORTH AT EAST
    Class BOpen
    Jan 16, 2026Apt 8S
    TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
    § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT NORTH WALL IN THE BATHROOM LOCATED AT APT 8S, 8th STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION AT EAST ORIGINAL VIOLATION 18243940 ISSUED 12-SEP-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017.3a(3)(a) or (b).
    Class BOpen
    Jan 15, 2026Apt 11T
    REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
    § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 11T, 11th STORY, 1st APARTMENT FROM EAST AT SOUTH
    Page 3 of 34