stoop
MAP
LeaderboardAbout
Building SafetyHousing Conditions

315 EAST 95 STREET

Manhattan · ZIP 10128 · BIN 1050333 · Upper East Side-Yorkville · Last violation Sep 8, 2026 · Last complaint Aug 17, 2026

NeighborhoodUpper East Side-Yorkville
More violations than 100% of nearby buildings
More violations than 100% of buildings and more complaints than 99% of buildings in Upper East Side-Yorkville. Size-normalized against residential buildings in the neighborhood for issues in the last 10 years.
ViolationsComplaints
Activity TrendsLast 5 years
More activity recently than in past years
Last 2 yrs: 128 violations · 124 complaints
'21'26ViolationsComplaints
▼ View all activity over time
Severityⓘopen violations
22 immediately hazardous (Class C) violations still open
Class C violations include lead paint, mold, pest infestations, heat/hot water failure, and structural hazards — the most serious category.
Class Cimmediately hazardous22Class Bhazardous26

What to watch forⓘ

  1. Hazardous violations are open, including fire safety, mold and pests, and heat and hot water.
    Worth checking · AI-assistedⓘ
    Look for blocked doorways, cluttered hallways, or damage to stair railings and fire escape access from windows. Look for droppings, gnaw marks, or live insects in cabinets, under sinks, and along baseboards. Turn on the heat and hot water and feel whether both reach full temperature within a few minutes.
    details ▸

    Deadlines vary by condition: immediate for heat and hot water, 14 days for self-closing doors, 21 days for lead paint, window guards, mold, and mice, cockroaches or rats, and 24 hours for everything else. They run from the date the owner is served, and mark when civil penalties can be sought in Housing Court. They are not a promise the condition is fixed by then. If the owner does not fix it, HPD can send its own contractor and bill them.

    • —Safety & fire — Blocked, unsafe, or inaccessible exits, hallways, stairs, or fire escape routes.
    • —Mold & pests — Rodent, cockroach, bedbug, or other pest infestation and extermination related issues.
Housing Preservation & Development Violations
Total violations since 2007
232
12 per year avg.↑ Up 653% in the last 2 years (128 vs 17 prior 2 yrs)
Open violations
55
Class C (immed. haz.)ⓘ22
Class B (hazardous)ⓘ26
Rent-impairingⓘ15
Housing Preservation & Development Complaints
Total complaints since 2003
243
10 per year avg.↑ Up 786% in the last 2 years (124 vs 14 prior 2 yrs)
Complaint Resolution
No access14%Violation issued21%No violation33%Phone resolved32%Other0%(243)
Urgency breakdown
Last 12 mo.

Top violation categories

5 yrsAll time
Egressⓘ41 violations
Maintenanceⓘ38 violations
Heat And Hot Waterⓘ15 violations
Paintingⓘ12 violations
Water Supplyⓘ12 violations
Carbon Monoxide Detecting Devicesⓘ9 violations
Posting/Signageⓘ7 violations
Smoke Detecting Devicesⓘ7 violations
Top complaint groupsⓘ
5 yrsAll time
Heat / hot waterⓘ34 complaints
Water & plumbingⓘ32 complaints
Bldg maintenanceⓘ29 complaints
Mold & pestsⓘ22 complaints
Safety & fireⓘ7 complaints
Electricalⓘ6 complaints
Appliancesⓘ2 complaints
Outdoor / structuralⓘ1 complaints
Hide violations ↑See complaints →

Violation log

177 violations · Close

All classesClass AClass BClass CClass IAllOpenClosed
ClassStatusApt
See something wrong? File a complaint with 311
—
Heat / hot water — Lack of heat, hot water, or heating system related issues affecting tenants.

The violation list below shows which conditions are open and when each was cited. If one in your own apartment is still unaddressed, call 311.

  • ABCs of Housing
  • NYC HPD, Penalties and Fees
Open violation ages
▪ < 30 days5% (3)
▪ 3–12 months49% (27)
▪ 1–3 years5% (3)
▪ 3+ years40% (22)
Prior 4 yr.
Immed. Emergency1%4%
Emergency66%47%
Non-Emergency33%49%
(98)
(47)
Issued
Description
Class CClosed—Oct 2, 2023MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR AND FRAME LEADING TO EAST COURT AT PUBLIC HALL, 1st STORY
Class BClosed4CSep 8, 2023REPAIR BROKEN, LOOSE CONNECTION · SEWERS AND DRAINAGE§ 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTELINE AT SINK IN THE KITCHEN LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed4CSep 8, 2023REPAIR LEAKY FAUCETS · WATER SUPPLY§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH
Class CClosed—Sep 8, 2023DOOR NOT SELF-CLOSING · EGRESS§ 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING HOOK AND EYE AT VESTIBULE DOOR
Class CClosed—Sep 8, 2023DOOR NOT SELF-CLOSING · EGRESS§ 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING HOOK AND EYE AT BUILDING ENTRANCE DOOR
Class BClosed4CSep 8, 2023REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AND SOUTH WALL IN THE BATHROOM LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH
Class CClosed4CSep 8, 2023ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATIONHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosedRENT IMPAIRING6ANov 14, 2022LEAKY ROOF · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed6ANov 14, 2022REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND WEST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM WEST AT NORTH
Class CClosed6ANov 14, 2022MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ... IN THE ENTRANCE LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM WEST AT NORTH
Class AClosed6ASep 26, 2022REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE ENTIRE APARTMENT LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM NORTH AT EAST
Class BClosedRENT IMPAIRING6ASep 26, 2022LEAKY ROOF · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE ENTIRE APARTMENT LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM NORTH AT EAST
Class AClosed—Sep 13, 2022POST SMOKE DETECTOR NOTICE · POSTING/SIGNAGE§ 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX AT PUBLIC HALL, 1st STORY
Class BClosedRENT IMPAIRING6ASep 13, 2022LEAKY ROOF · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM WEST AT NORTH
Class AClosed—Sep 13, 2022POST GAS LEAK NOTICE · POSTING/SIGNAGE§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED
Class BClosed6ASep 13, 2022REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND WEST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM WEST AT NORTH
Class CClosed6ASep 13, 2022MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ... IN THE ENTRANCE LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM WEST AT NORTH
Class AClosed—Sep 13, 2022POST CO DETECTOR NOTICE · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING.
Class CClosed—Aug 25, 2022DOOR NOT SELF-CLOSING · EGRESS§ 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING HOOK AND EYE INSTALLED AT VESTIBULE AT PUBLIC HALL, 1st STORY
Class CClosed—Aug 25, 2022MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LEADING TO EAST YARD AT PUBLIC HALL, 1st STORY
Class CClosed—Aug 25, 2022MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT VESTIBULE AT PUBLIC HALL, 1st STORY
Class CClosed—Aug 25, 2022DOOR NOT SELF-CLOSING · EGRESS§ 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING HOOK AND EYE INSTALLED AT BUILDING FRONT ENTRANCE , 1st STORY
Class CClosed—Aug 25, 2022MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT BUILDING FRONT ENTRANCE , 1st STORY
Class AClosed—Sep 27, 2021PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WEST WALL AT BULHEAD STAIRS TO ROOF , 6th STORY
Class BClosedRENT IMPAIRING—Sep 27, 2021LEAKY ROOF · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING AT BULKHEAD TO ROOF , 6th STORY
Class BClosedRENT IMPAIRING—Sep 27, 2021REMOVE ENCUMBRANCES · EGRESS§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AT BULKHEAD TO ROOF , 6th STORY
Class BClosedRENT IMPAIRING—Sep 27, 2021REMOVE ENCUMBRANCES · EGRESS§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF BICYCLE AT PUBLIC HALL, 5th STORY
Class AClosed—Sep 27, 2021TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING(2 SQ FT.) AND WEST WALL(13 SQ FT.) AT BULKHEAD TO ROOF , 6th STORY
Class BClosedRENT IMPAIRING—Sep 27, 2021F/E ADJUST THE DROP LADDER · EGRESS§ 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS AT STACK WEST SIDE OF BUILDING AT FIRE ESCAPE
Class BClosed—Sep 27, 2021REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT WEST WALL BULKHEAD TO ROOF , 6th STORY
Class AClosed—Apr 1, 2021FILE ANNUAL BEDBUG REPORT · FILING: BEDBUGS(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
Class AClosed—Aug 9, 2018PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 6th STORY
Class BClosedRENT IMPAIRING—Aug 9, 2018LEAKY ROOF · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT WEST WALL AT BULKHEAD
Class AClosed—Aug 9, 2018PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WEST WALL AT BULKHEAD
Class AClosed—Aug 9, 2018POST SIGN INDICATING NAME AND ADDRESS OF JANITOR, ETC. · POSTING/SIGNAGE§ 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORY
Class AClosed—Aug 9, 2018POST GAS LEAK NOTICE · POSTING/SIGNAGE§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORY
Class AClosed—Aug 9, 2018REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT PUBLIC HALL, 6th STORY
Class BClosed—Aug 9, 2018REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT WEST WALL AT BULKHEAD AT ROOF
Class BClosedRENT IMPAIRING—Aug 9, 2018REMOVE ENCUMBRANCES · EGRESS§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSE HOLD ITEMS STORED AT BULKHEAD AT ROOF
Class BClosedRENT IMPAIRING—Aug 9, 2018REMOVE ENCUMBRANCES · EGRESS§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS STORED AT ROOF THROUGHOUT
Class BClosed—Jul 23, 2018REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDENT MATERIAL WEST WALL AT BULKHEAD AT PUBLIC HALL, 6th STORY
Class CClosed—Jul 23, 2018POST BOILER ROOM ACCESS NOTICE · HEAT AND HOT WATER§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM SIGN MISSING AT PUBLIC HALL, 1st STORY
Class AClosed—Jul 23, 2018POST GAS LEAK NOTICE · POSTING/SIGNAGE§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORY
Class AClosed—Jul 23, 2018PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WEST WALL BULKHEAD AT PUBLIC HALL, 6th STORY
Class CClosed—Sep 9, 2016POST BOILER ROOM ACCESS NOTICE · HEAT AND HOT WATER§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING AT PUBLIC HALL, 1st STORY
Class BClosed—Sep 9, 2016REMOVE ENCUMBRANCE · EGRESSSECTION 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES 3 RD STORY , BLDG FRONT AT FIRE ESCAPE, 3rd STORY
Class AClosed—Sep 9, 2016POST SIGN INDICATING NAME AND ADDRESS OF JANITOR, ETC. · POSTING/SIGNAGE§ 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORY
Class CClosedRENT IMPAIRING4EDec 5, 2012NO GAS · KITCHEN AND KITCHENETTESSECTION 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES RANGE IN THE KITCHEN LOCATED AT APT 4E, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class CClosedRENT IMPAIRING—Nov 23, 2012F/E DEFECTIVE: PROPERLY SECURE · EGRESSSECTION 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. PROPERLY SECURE THE LOOSE METAL TREAD, 4TH FORM THE BOTTOM, AT THE 1ST BALCONY AT BLDG FRONT AT FIRE ESCAPE, 2nd STORY
Class CClosedRENT IMPAIRING5ENov 23, 2012NO GAS · KITCHEN AND KITCHENETTESSECTION 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT THE STOVE IN THE KITCHEN LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class CClosed
Oct 2, 2023
MAKE DOORS SELF-CLOSING · EGRESS
§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR AND FRAME LEADING TO EAST COURT AT PUBLIC HALL, 1st STORY
Class BClosed
Sep 8, 2023Apt 4C
REPAIR BROKEN, LOOSE CONNECTION · SEWERS AND DRAINAGE
§ 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTELINE AT SINK IN THE KITCHEN LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed
Sep 8, 2023Apt 4C
REPAIR LEAKY FAUCETS · WATER SUPPLY
§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH
Class CClosed
Sep 8, 2023
DOOR NOT SELF-CLOSING · EGRESS
§ 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING HOOK AND EYE AT VESTIBULE DOOR
Class CClosed
Sep 8, 2023
DOOR NOT SELF-CLOSING · EGRESS
§ 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING HOOK AND EYE AT BUILDING ENTRANCE DOOR
Class BClosed
Sep 8, 2023Apt 4C
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AND SOUTH WALL IN THE BATHROOM LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH
Class CClosed
Sep 8, 2023Apt 4C
ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATION
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosedRENT IMPAIRING
Nov 14, 2022Apt 6A
LEAKY ROOF · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed
Nov 14, 2022Apt 6A
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND WEST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM WEST AT NORTH
Class CClosed
Nov 14, 2022Apt 6A
MAKE DOORS SELF-CLOSING · EGRESS
§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ... IN THE ENTRANCE LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM WEST AT NORTH
Class AClosed
Sep 26, 2022Apt 6A
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE ENTIRE APARTMENT LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM NORTH AT EAST
Class BClosedRENT IMPAIRING
Sep 26, 2022Apt 6A
LEAKY ROOF · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE ENTIRE APARTMENT LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM NORTH AT EAST
Class AClosed
Sep 13, 2022
POST SMOKE DETECTOR NOTICE · POSTING/SIGNAGE
§ 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX AT PUBLIC HALL, 1st STORY
Class BClosedRENT IMPAIRING
Sep 13, 2022Apt 6A
LEAKY ROOF · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM WEST AT NORTH
Class AClosed
Sep 13, 2022
POST GAS LEAK NOTICE · POSTING/SIGNAGE
§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED
Class BClosed
Sep 13, 2022Apt 6A
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND WEST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM WEST AT NORTH
Class CClosed
Sep 13, 2022Apt 6A
MAKE DOORS SELF-CLOSING · EGRESS
§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ... IN THE ENTRANCE LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM WEST AT NORTH
Class AClosed
Sep 13, 2022
POST CO DETECTOR NOTICE · CARBON MONOXIDE DETECTING DEVICES
§ 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING.
Class CClosed
Aug 25, 2022
DOOR NOT SELF-CLOSING · EGRESS
§ 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING HOOK AND EYE INSTALLED AT VESTIBULE AT PUBLIC HALL, 1st STORY
Class CClosed
Aug 25, 2022
MAKE DOORS SELF-CLOSING · EGRESS
§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LEADING TO EAST YARD AT PUBLIC HALL, 1st STORY
Class CClosed
Aug 25, 2022
MAKE DOORS SELF-CLOSING · EGRESS
§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT VESTIBULE AT PUBLIC HALL, 1st STORY
Class CClosed
Aug 25, 2022
DOOR NOT SELF-CLOSING · EGRESS
§ 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING HOOK AND EYE INSTALLED AT BUILDING FRONT ENTRANCE , 1st STORY
Class CClosed
Aug 25, 2022
MAKE DOORS SELF-CLOSING · EGRESS
§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT BUILDING FRONT ENTRANCE , 1st STORY
Class AClosed
Sep 27, 2021
PAINT · PAINTING
§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WEST WALL AT BULHEAD STAIRS TO ROOF , 6th STORY
Class BClosedRENT IMPAIRING
Sep 27, 2021
LEAKY ROOF · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING AT BULKHEAD TO ROOF , 6th STORY
Class BClosedRENT IMPAIRING
Sep 27, 2021
REMOVE ENCUMBRANCES · EGRESS
§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AT BULKHEAD TO ROOF , 6th STORY
Class BClosedRENT IMPAIRING
Sep 27, 2021
REMOVE ENCUMBRANCES · EGRESS
§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF BICYCLE AT PUBLIC HALL, 5th STORY
Class AClosed
Sep 27, 2021
TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING(2 SQ FT.) AND WEST WALL(13 SQ FT.) AT BULKHEAD TO ROOF , 6th STORY
Class BClosedRENT IMPAIRING
Sep 27, 2021
F/E ADJUST THE DROP LADDER · EGRESS
§ 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS AT STACK WEST SIDE OF BUILDING AT FIRE ESCAPE
Class BClosed
Sep 27, 2021
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT WEST WALL BULKHEAD TO ROOF , 6th STORY
Class AClosed
Apr 1, 2021
FILE ANNUAL BEDBUG REPORT · FILING: BEDBUGS
(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
Class AClosed
Aug 9, 2018
PAINT · PAINTING
§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 6th STORY
Class BClosedRENT IMPAIRING
Aug 9, 2018
LEAKY ROOF · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT WEST WALL AT BULKHEAD
Class AClosed
Aug 9, 2018
PAINT · PAINTING
§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WEST WALL AT BULKHEAD
Class AClosed
Aug 9, 2018
POST SIGN INDICATING NAME AND ADDRESS OF JANITOR, ETC. · POSTING/SIGNAGE
§ 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORY
Class AClosed
Aug 9, 2018
POST GAS LEAK NOTICE · POSTING/SIGNAGE
§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORY
Class AClosed
Aug 9, 2018
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT PUBLIC HALL, 6th STORY
Class BClosed
Aug 9, 2018
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT WEST WALL AT BULKHEAD AT ROOF
Class BClosedRENT IMPAIRING
Aug 9, 2018
REMOVE ENCUMBRANCES · EGRESS
§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSE HOLD ITEMS STORED AT BULKHEAD AT ROOF
Class BClosedRENT IMPAIRING
Aug 9, 2018
REMOVE ENCUMBRANCES · EGRESS
§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS STORED AT ROOF THROUGHOUT
Class BClosed
Jul 23, 2018
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDENT MATERIAL WEST WALL AT BULKHEAD AT PUBLIC HALL, 6th STORY
Class CClosed
Jul 23, 2018
POST BOILER ROOM ACCESS NOTICE · HEAT AND HOT WATER
§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM SIGN MISSING AT PUBLIC HALL, 1st STORY
Class AClosed
Jul 23, 2018
POST GAS LEAK NOTICE · POSTING/SIGNAGE
§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORY
Class AClosed
Jul 23, 2018
PAINT · PAINTING
§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WEST WALL BULKHEAD AT PUBLIC HALL, 6th STORY
Class CClosed
Sep 9, 2016
POST BOILER ROOM ACCESS NOTICE · HEAT AND HOT WATER
§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING AT PUBLIC HALL, 1st STORY
Class BClosed
Sep 9, 2016
REMOVE ENCUMBRANCE · EGRESS
SECTION 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES 3 RD STORY , BLDG FRONT AT FIRE ESCAPE, 3rd STORY
Class AClosed
Sep 9, 2016
POST SIGN INDICATING NAME AND ADDRESS OF JANITOR, ETC. · POSTING/SIGNAGE
§ 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORY
Class CClosedRENT IMPAIRING
Dec 5, 2012Apt 4E
NO GAS · KITCHEN AND KITCHENETTES
SECTION 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES RANGE IN THE KITCHEN LOCATED AT APT 4E, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class CClosedRENT IMPAIRING
Nov 23, 2012
F/E DEFECTIVE: PROPERLY SECURE · EGRESS
SECTION 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. PROPERLY SECURE THE LOOSE METAL TREAD, 4TH FORM THE BOTTOM, AT THE 1ST BALCONY AT BLDG FRONT AT FIRE ESCAPE, 2nd STORY
Class CClosedRENT IMPAIRING
Nov 23, 2012Apt 5E
NO GAS · KITCHEN AND KITCHENETTES
SECTION 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT THE STOVE IN THE KITCHEN LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH