Class BClosed
Jul 20, 2017Apt 706
REPAIR LEAKY FAUCETS · WATER SUPPLY
§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT THE BATHTUB IN THE BATHROOM LOCATED AT APT 706, 7th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosed
Jul 20, 2017Apt 706
REPAIR · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE CEILING LIGHT FIXTURE IN THE BATHROOM LOCATED AT APT 706, 7th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class AClosed
Jul 20, 2017Apt 706
RESET WATER CLOSET BOWL · SEWERS AND DRAINAGE
§ 27-2026 ADM CODE RESET, SO AS TO SECURE A PROPER AND TIGHT CONNECTION, THE WATER CLOSET BOWL ... IN THE BATHROOM LOCATED AT APT 706, 7th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosed
Jul 20, 2017Apt 706
MAKE DOORS SELF-CLOSING · EGRESS
§ 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS .... IN THE ENTRANCE LOCATED AT APT 706, 7th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class AClosed
Jul 13, 2017
POST GAS LEAK NOTICE · POSTING/SIGNAGE
§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORY
Class BClosed
Jul 13, 2017
REPLACE · MAINTENANCE
§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING SAFETY CAP /COVER AT ELECTRICAL OUTLETS, TOTAL 5.. AT PUBLIC HALL, 1st STORY
Class BClosed
Jul 12, 2017
RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED
§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE CRACKED WIRE GLASS AT DOOR TO EAST FIRE STAIR , 9TH STY, AT PUBLIC HALL
Class BClosed
Jul 12, 2017
RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED
§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE PAINTED SPRINLER HEADS (9) AT, SPRINKLER SYSTEM, 9TH STORY, AT PUBLIC HALL
Class BClosed
Jul 12, 2017
RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED
§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE PAINTED SPRINLER HEADS (2) AT, SPRINKLER SYSTEM, 1ST STORY, AT PUBLIC HALL
Class AClosed
Jun 12, 2017Apt 509
PAINT METAL · PAINTING
§ 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION STEAM RADIATORS IN THE ENTIRE APARTMENT LOCATED AT APT 509, 5th STORY, 3rd APARTMENT FROM SOUTH AT WEST
Class BClosed
Jun 12, 2017Apt 509
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS AND CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 509, 5th STORY, 3rd APARTMENT FROM SOUTH AT WEST
Class CClosedRENT IMPAIRING
Jun 5, 2017Apt 1107
INADEQUATE COLD WATER · WATER SUPPLY
§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT SINK IN THE KITCHEN LOCATED AT APT 1107, 11th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class CClosedRENT IMPAIRING
Jun 5, 2017Apt 1107
INADEQUATE HOT WATER SUPPLY (VOLUME) · WATER SUPPLY
§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT SINK IN THE KITCHEN LOCATED AT APT 1107, 11th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BClosed
May 26, 2017Apt 1107
REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE KITCHEN LOCATED AT APT 1107, 11th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class AClosed
May 26, 2017Apt 1107
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD CABINET IN THE KITCHEN LOCATED AT APT 1107, 11th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BClosed
May 26, 2017Apt 1107
REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE KITCHEN LOCATED AT APT 1107, 11th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BClosed
May 26, 2017Apt 1107
REPAIR BROKEN, LOOSE CONNECTION · SEWERS AND DRAINAGE
§ 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTELINE UNDER SINK IN THE KITCHEN LOCATED AT APT 1107, 11th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BClosed
May 26, 2017Apt 1107
ABATE THE NUISANCE OF MICE · EXTERMINATION & RODENT ERADICATION
§ 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1107, 11th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class AClosed
May 26, 2017Apt 1107
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WALLS IN THE KITCHEN LOCATED AT APT 1107, 11th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class AClosed
May 2, 2017
IV-1. MAILBOXES PRESENT · POSTING/SIGNAGE
§ 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR INCORRECT FRAME AT PUBLIC HALL, 1st STORY
Class BClosed
May 2, 2017Apt 505
REPAIR LEAKY FAUCETS · WATER SUPPLY
§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT B-ROOM 505, 5th STORY, 3rd B-ROOM FROM SOUTH AT WEST
Class BClosed
May 2, 2017Apt 505
REPLACE · MAINTENANCE
§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ESCUTSCHEON PLATE AT RISER AT CEILING AND FLOOR IN THE BATHROOM LOCATED AT B-ROOM 505, 5th STORY, 3rd B-ROOM FROM SOUTH AT WEST
Class AClosed
May 2, 2017Apt 505
REPAIR · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE CAULK AROUND IN THE 2ND ROOM FROM NORTH LOCATED AT B-ROOM 505, 5th STORY, 3rd B-ROOM FROM SOUTH AT WEST
Class AClosed
May 2, 2017Apt 505
REFIT DOORS ETC. · EGRESS
§ 27-2005 ADM CODE REFIT THE ENTRANCE DOOR LOCATED AT B-ROOM 505, 5th STORY, 3rd B-ROOM FROM SOUTH AT WEST
Class CClosedRENT IMPAIRING
Mar 1, 2017Apt 706
INADEQUATE HOT WATER · HEAT AND HOT WATER
§ 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE KITCHENETTE LOCATED AT B-ROOM 706, 7th STORY, 1st B-ROOM FROM EAST AT SOUTH
Class BClosed
Aug 1, 2016Apt 505
RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED
§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE FIRE RATED DOOR AT ENTRANCE LOCATED AT B-ROOM 505 , 5th STORY, 3rd B-ROOM FROM SOUTH AT WEST
Class AClosed
Aug 1, 2016Apt 505
REPLACE · MAINTENANCE
§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ESCUTCHEON PLATE AT RISER IN THE BATHROOM LOCATED AT B-ROOM 505 , 5th STORY, 3rd B-ROOM FROM SOUTH AT WEST
Class BClosedRENT IMPAIRING
Aug 1, 2016Apt 505
REPAIR FLUSHING APPARATUS OF WATER CLOSET · SEWERS AND DRAINAGE
§ 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET .. IN THE BATHROOM LOCATED AT B-ROOM 505 , 5th STORY, 3rd B-ROOM FROM SOUTH AT WEST
Class BClosedRENT IMPAIRING
Aug 1, 2016Apt 505
REMOVE OBSTRUCTIONS · SEWERS AND DRAINAGE
§ 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTELINE AT WASH BASIN IN THE BATHROOM LOCATED AT B-ROOM 505 , 5th STORY, 3rd B-ROOM FROM SOUTH AT WEST
Class BClosed
Aug 1, 2016Apt 505
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN THE BATHROOM LOCATED AT B-ROOM 505 , 5th STORY, 3rd B-ROOM FROM SOUTH AT WEST
Class BClosed
Aug 1, 2016Apt 505
REPAIR · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTERBALANCE AT LOWER SASH OF WEST WINDOW IN THE 1st ROOM FROM NORTH LOCATED AT B-ROOM 505 , 5th STORY, 3rd B-ROOM FROM SOUTH AT WEST
Class BClosed
Aug 1, 2016Apt 505
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND CEILING IN THE 1st ROOM FROM NORTH LOCATED AT B-ROOM 505 , 5th STORY, 3rd B-ROOM FROM SOUTH AT WEST
Class BClosed
Jun 29, 2016Apt 1304
REPAIR · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INTERCOM RETURN SYSTEM LOCATED AT APT 1304, 13th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class AClosed
Jun 29, 2016Apt 1304
NO LOCK AND KEY TO APARTMENT · PROTECTIVE DEVICES AND FIRE PROTECTION
§ 27-2043 ADM CODE PROVIDE A LOCK AND KEY TO THE ENTRANCE DOOR OF DWELLING UNIT AND, IF A CL A MULTIPLE DWELLING, ALSO A CHAIN GUARD IN THE ENTRANCE LOCATED AT APT 1304, 13th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BClosed
Jun 20, 2016Apt 505
NO SMOKE DETECTOR OR SMOKE DECTOR NOT OPERATIONAL · SMOKE DETECTING DEVICES
§ 27-2045, 2046 ADM CODE PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE LOCATED AT B-ROOM 505, 5th STORY, 3rd B-ROOM FROM NORTH AT EAST
Class BClosed
Jun 20, 2016Apt 505
NO CO DETECTOR OR DETECTOR NOT OPERATIONAL · CARBON MONOXIDE DETECTING DEVICES
§ 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. LOCATED AT B-ROOM 505, 5th STORY, 3rd B-ROOM FROM NORTH AT EAST
Class BClosed
Jun 20, 2016Apt 505
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT B-ROOM 505, 5th STORY, 3rd B-ROOM FROM NORTH AT EAST
Class BClosedRENT IMPAIRING
Jun 20, 2016Apt 505
REPAIR FLUSHING APPARATUS OF WATER CLOSET · SEWERS AND DRAINAGE
§ 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET , IN THE BATHROOM LOCATED AT B-ROOM 505, 5th STORY, 1st B-ROOM FROM NORTH AT EAST
Class CClosed
Jun 16, 2016Apt 1416
RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED
§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE LOWER WINDOW GLASS IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT B-ROOM 1416, 14th STORY, 1st B-ROOM FROM WEST AT NORTH
Class AClosed
Jun 14, 2016Apt 709
PAINT METAL · PAINTING
§ 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION RADIATOR IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT B-ROOM 709, 7th STORY, 6th B-ROOM FROM WEST AT NORTH
Class BOpen
Jun 14, 2016Apt 709
RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED
§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE ENRANCE DOOR IN THE ROOM LOCATED AT B-ROOM 709, 7th STORY, 6th B-ROOM FROM WEST AT NORTH
Class BOpen
Jun 14, 2016Apt 709
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING INSIDE THE CLOSET IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT B-ROOM 709, 7th STORY, 6th B-ROOM FROM WEST AT NORTH
Class BOpen
Jun 14, 2016Apt 709
RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED
§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE ELECTRICAL LIGHT FIXTURE AT CEILING IN THE BATHROOM LOCATED AT B-ROOM 709, 7th STORY, 6th B-ROOM FROM WEST AT NORTH
Class AClosed
Jun 14, 2016Apt 709
NO PEEP HOLE · PROTECTIVE DEVICES AND FIRE PROTECTION
§ 27-2041 ADM CODE PROVIDE A PEEP HOLE IN ENTRANCE DOOR OF THE DWELLING UNIT SO LOCATED SO AS TO PERMIT A PERSON INSIDE THE DWELLING TO VIEW ANY PERSON OUTSIDE ENTRANCE DOOR , IN THE ROOM LOCATED AT B-ROOM 709, 7th STORY, 6th B-ROOM FROM WEST AT NORTH
Class AClosed
Jun 14, 2016Apt 709
REFIT DOORS ETC. · EGRESS
§ 27-2005 ADM CODE REFIT DOOR IN THE BATHROOM LOCATED AT B-ROOM 709, 7th STORY, 6th B-ROOM FROM WEST AT NORTH
Class AClosed
Jun 14, 2016Apt 709
PAINT METAL · PAINTING
§ 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION RISER IN THE BATHROOM LOCATED AT B-ROOM 709, 7th STORY, 6th B-ROOM FROM WEST AT NORTH
Class BClosed
Jun 14, 2016
REPAIR · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL LIGHT FIXTURES AT CEILING (ABOVE ROOM 709) AT PUBLIC HALL, 7th STORY
Class BClosed
Mar 15, 2016Apt 1104
REPAIR · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL POWER OUTLETS THROUGHOUT LOCATED AT B-ROOM 1104, 11th STORY, 1st B-ROOM FROM NORTH AT EAST
Class BClosed
Feb 24, 2016Apt 709
REPAIR/ABATE UNSAFE WIRES · ARTIFICIAL LIGHTING
§ 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL BX CABLE AT CEILING IN THE BATHROOM LOCATED AT APT 709, 7th STORY, 4th APARTMENT FROM WEST AT NORTH
Class AClosed
Feb 24, 2016Apt 709
RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED
§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE ESCUTCHEON PLATE AT(CEILING) STEAM RISER IN THE BATHROOM LOCATED AT APT 709, 7th STORY, 4th APARTMENT FROM WEST AT NORTH