Severityⓘopen violations
24 immediately hazardous (Class C) violations still open
Class C violations include lead paint, mold, pest infestations, heat/hot water failure, and structural hazards — the most serious category.
Class Cimmediately hazardous24Class Bhazardous20

What to watch forⓘ

  1. Hazardous violations are open, including fire safety, and heat and hot water.
    Worth checking · AI-assistedⓘ
    Look at stairwell doors, hallways, and fire escapes to see whether they open freely and are clear of obstacles. Turn on the radiator or heat to check whether it produces warmth.
    details ▸

    Deadlines vary by condition: immediate for heat and hot water, 14 days for self-closing doors, 21 days for lead paint, window guards, mold, and mice, cockroaches or rats, and 24 hours for everything else. They run from the date the owner is served, and mark when civil penalties can be sought in Housing Court. They are not a promise the condition is fixed by then. If the owner does not fix it, HPD can send its own contractor and bill them.

    • —Safety & fire — Blocked, unsafe, or inaccessible exits, hallways, stairs, or fire escape routes.
    • —Heat / hot water — Lack of heat, hot water, or heating system related issues affecting tenants.

    The violation list below shows which conditions are open and when each was cited. If one in your own apartment is still unaddressed, call 311.

    • ABCs of Housing
Housing Preservation & Development Violations
Total violations since 2007
153
8 per year avg.↓ Down 74% in the last 2 years (6 vs 23 prior 2 yrs)
Open violations
64
Class C (immed. haz.)ⓘ24
Class B (hazardous)ⓘ20
Rent-impairingⓘ12
Housing Preservation & Development Complaints
Total complaints since 2003
230
10 per year avg.↑ Up 2100% in the last 2 years (22 vs 1 prior 2 yrs)
Complaint Resolution
No access25%Violation issued8%No violation11%Phone resolved56%Other0%(230)
Urgency breakdown
Last 12 mo.

Top violation categories

5 yrsAll time
Maintenanceⓘ21 violations
Kitchen And Kitchenettesⓘ15 violations
Egressⓘ7 violations
Filing: Bedbugsⓘ5 violations
Retiredⓘ5 violations
Cleaningⓘ3 violations
Paintingⓘ1 violations
Artificial Lightingⓘ1 violations
Top complaint groupsⓘ
5 yrsAll time
Heat / hot waterⓘ19 complaints
Mold & pestsⓘ8 complaints
Water & plumbingⓘ5 complaints
Bldg maintenanceⓘ4 complaints
Electricalⓘ2 complaints
Safety & fireⓘ2 complaints
Elevatorⓘ2 complaints
Outdoor / structuralⓘ1 complaints
Hide violations ↑See complaints →

Violation log

64 violations · Open

All classesClass AClass BClass CClass IAllOpenClosed
ClassStatusApt
See something wrong? File a complaint with 311
  • NYC HPD, Penalties and Fees
  • Pests reported in the last five years.
    Worth checking · AI-assistedⓘ
    Look along baseboards, in corners, and behind appliances for droppings, dead insects, or signs of active pest activity.
    details ▸

    Roaches, mice, and rats can be hazards for people with respiratory conditions such as asthma. Bedbugs spread between apartments through small cracks in walls and floors, so catching them early matters.

    Report pests to the owner and call 311 if they are not dealt with. For bedbugs, an HPD inspector visits, and a violation is issued only if they can visually confirm live bedbugs.

    • ABCs of Housing
  • Open violation ages
    ▪ 3–12 months2% (1)
    ▪ 1–3 years16% (10)
    ▪ 3+ years83% (52)
    Prior 4 yr.
    Immed. Emergency0%9%
    Emergency100%58%
    Non-Emergency0%33%
    (11)
    (33)
    Issued
    Description
    Class AOpen—Apr 29, 2026FILE ANNUAL BEDBUG REPORT · FILING: BEDBUGS(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
    Class BOpen—Jun 16, 2025REMOVE ENCUMBRANCE · EGRESS§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES HOUSEHOLD ITEMS AT BALCONY AT BUILDING FRONT AT FIRE ESCAPE, 4th STORY
    Class AOpen—Jun 4, 2025FILE ANNUAL BEDBUG REPORT · FILING: BEDBUGS(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
    Class COpen15Jan 23, 2025MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 15, 6th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class COpen12Jul 30, 2024TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 30 SQ. FT AT EAST AND WEST WALLS AND CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 12, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH
    Class COpenRENT IMPAIRING14Jun 4, 2024NO GAS · KITCHEN AND KITCHENETTES§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE AT KITCHEN. LOCATED AT APT 14, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST
    Class COpenRENT IMPAIRING10Jun 4, 2024NO GAS · KITCHEN AND KITCHENETTES§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE AT KITCHEN. LOCATED AT APT 10, 4th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class BOpen7May 28, 2024ABATE THE NUISANCE · MAINTENANCE§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPRATED LOCK INSTALLED AT ENTRANCE DOOR TO ROOM LEADING TO THE FIRE ESCAPE WINDOW IN THE 2nd ROOM FROM EAST LOCATED AT APT 7, 3rd STORY, APARTMENT AT NORTH
    Class COpenRENT IMPAIRING6May 28, 2024NO GAS · KITCHEN AND KITCHENETTES§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE AT KITCHEN AT APT. 6 LOCATED AT APT 6, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
    Class COpenRENT IMPAIRING9May 28, 2024NO GAS · KITCHEN AND KITCHENETTES§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE AT KITCHEN AT APT. 9 LOCATED AT APT 9, 4th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class AOpen—Apr 1, 2024FILE ANNUAL BEDBUG REPORT · FILING: BEDBUGS(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
    Class AOpen—Mar 15, 2023FILE ANNUAL BEDBUG REPORT · FILING: BEDBUGS(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
    Class COpen—Oct 14, 2022RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS PANE AT UPPER AND LOWER SASH WINDOW AT THE 5TH STORY AT PUBLIC HALL
    Class COpen—Oct 14, 2022RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS PANE AT UPPER AND LOWER SASH WINDOW AT THE 6TH STORY AT PUBLIC HALL
    Class COpen—Oct 14, 2022RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS PANE AT UPPER AND LOWER SASH WINDOW AT THE 4TH STORY AT PUBLIC HALL
    Class COpen—Oct 14, 2022RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE THE SKLYLIGH
    Class COpen—Oct 14, 2022RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS PANE AT UPPER AND LOWER SASH WINDOW AT THE 3RD STORY AT PUBLIC HALL
    Class BOpen—Jun 28, 2022REMOVE ACCUMULATION OR RUBBISH · CLEANING§ 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE SOUTH COURT
    Class COpen—Jun 15, 2022REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRERETARDING CEILING AND WEST WALL AT 1st PUBLIC HALL BULKHEAD FROM NORTH AT WEST, 6th STORY
    Class BOpenRENT IMPAIRING—Jun 15, 2022REMOVE ENCUMBRANCES · EGRESS§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AT 1st PUBLIC HALL BULKHEAD FROM NORTH AT WEST, 6th STORY
    Class COpen—Jun 15, 2022MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT 1st PUBLIC HALL BULKHEAD FROM NORTH AT WEST, 6th STORY
    Class AOpen—Jun 15, 2022PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND WEST WALL AT 1st PUBLIC HALL BULKHEAD FROM NORTH AT WEST, 6th STORY
    Class BOpen—Jun 15, 2022REMOVE ACCUMULATION OR RUBBISH · CLEANING§ 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE SOUTH YARD, 1st STORY
    Class AOpen—Feb 15, 2022FILE ANNUAL BEDBUG REPORT · FILING: BEDBUGS(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
    Class AOpen—Apr 1, 2021FILE ANNUAL BEDBUG REPORT · FILING: BEDBUGS(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
    Class BOpen—May 11, 2020REMOVE ENCUMBRANCE · EGRESS§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES HOUEHOLD ITEMS AT 5TH STORY BALCONY, FRONT STACK AT FIRE ESCAPE
    Class BOpen—Feb 27, 2020REMOVE ENCUMBRANCE · EGRESS§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES FLOWER POT AT 3RD STORY BALCONY, FRONT STACK AT FIRE ESCAPE
    Class BOpenRENT IMPAIRING—Feb 27, 2020REMOVE ENCUMBRANCES · EGRESS§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF RUBBISH BINS AT PUBLIC HALL, 1st STORY
    Class COpen—Dec 16, 2019POST BOILER ROOM ACCESS NOTICE · HEAT AND HOT WATER§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM AT OR NEAR MAILBOX AT PUBLIC HALL, 1st STORY
    Class COpen—Dec 16, 2019PROVIDE ACCESS TO BOILER ROOM · HEAT AND HOT WATER§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LEADING TO BOILER ROOM LOCKED AT PUBLIC HALL, 1st STORY
    Class AOpen—Oct 7, 2019POST GAS LEAK NOTICE · POSTING/SIGNAGE§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORY
    Class AOpen—Oct 7, 2019POST HOUSING INFORMATION GUIDE NOTICE · POSTING/SIGNAGE§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY
    Class BOpen—Oct 7, 2019REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER SASH WINDOW AT PUBLIC HALL, 3rd STORY
    Class AOpen—Mar 15, 2019PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AND WALLS. AT PUBLIC HALL, 1st STORY
    Class BOpen—Mar 15, 2019REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AT PUBLIC HALL, 1st STORY
    Class BOpen—Feb 6, 2019PROVIDE · MAINTENANCE§ 27-2005 ADM CODE PROVIDE SECURITY IN THE EVENT OF A POWER OUTAGE BY MEANS OF AN ACCEPTABLE MECHANICAL HEAVY DUTY LOCK AND LATCH SET AT STREET ENTRANCE DOOR TO BUILDING
    Class BOpenRENT IMPAIRING—Feb 6, 2019REMOVE ENCUMBRANCES · EGRESS§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF GARBAGE RECEPTACLES STORED AT PUBLIC HALL, 1st STORY
    Class AOpen—Feb 6, 2019STORAGE OF GARBAGE CANS · COLLECTION OF WASTE§ 27-2021 ADM CODE PROVIDE PLACE WITHIN THE BUILDING FOR THE STORAGE OF WASTE RECEPTACLES AND DISINFECT SAME REGULARLY.
    Class COpenRENT IMPAIRING—Feb 6, 2019REMOVE ILLEGAL FASTENING · EGRESS§ 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CONSISTING OF AN UNACCEPTABLE ELECTROMAGNETIC LOCKING DEVICE INSTALLED AT STREET ENTRANCE DOOR TO BUILDING
    Class AOpen—Jun 29, 2018POST HOUSING INFORMATION GUIDE NOTICE · POSTING/SIGNAGE§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY
    Class COpen—Jun 29, 2018ABATE THE NUISANCE · MAINTENANCE§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF GARBAGE STORED UNDER STAIRS AT PUBLIC HALL, 1st STORY
    Class COpen—Jun 29, 2018RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS PANE AT LOWER WINDOW SASH AT FIRE ESCAPE WINDOW WEST WALL AT PUBLIC HALL, 3rd STORY
    Class COpenRENT IMPAIRING—Jun 29, 2018REMOVE ILLEGAL FASTENING · EGRESS§ 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CONSISTING OF AN UNACCEPTABLE ELECTROMAGNETIC LOCKING DEVICE INSTALLED AT STREET ENTRANCE DOOR TO BUILDING
    Class COpen—Jun 29, 2018PROVIDE · MAINTENANCE§ 27-2005 ADM CODE PROVIDE SECURITY IN THE EVENT OF A POWER OUTAGE BY MEANS OF AN ACCEPTABLE MECHANICAL HEAVY DUTY LOCK AND LATCH SET AT STREET ENTRANCE DOOR TO BUILDING
    Class COpen—Jun 29, 2018POST BOILER ROOM ACCESS NOTICE · HEAT AND HOT WATER§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM KEY NOT ON PREMISES AT PUBLIC HALL, 1st STORY
    Class AOpen—Jun 29, 2018POST SIGN INDICATING NAME AND ADDRESS OF JANITOR, ETC. · POSTING/SIGNAGE§ 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORY
    Class AOpen—Jun 29, 2018POST GAS LEAK NOTICE · POSTING/SIGNAGE§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORY
    Class COpenRENT IMPAIRING—Dec 14, 2017FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN · EGRESS§ 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN, DEFECTIVE AND/OR MISSING SECONDARY MEANS OF EGRESS DEFECTIVE - BROKEN 11TH TREAD FROM BOTTOM AT 3RD STORY FIRE ESCAPE STAIRS AT BUILDING NORTH
    Class AOpen—Oct 17, 2017PAINT METAL · PAINTING§ 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALL STORIES, ALL BALCONIES AND ALL COMPONETS BUILDING FRONT AT FIRE ESCAPE, SECTION AT EAST
    Class BOpen—Oct 17, 2017PROVIDE · MAINTENANCE§ 27-2005 ADM CODE PROVIDE SECURITY IN THE EVENT OF AN POWER OUTAGE BY MEANS OF AN ACCEPTABLE MECHANICAL HEAVY DUTY LOCK AND LATCH SET AT BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORY
    Class AOpen
    Apr 29, 2026
    FILE ANNUAL BEDBUG REPORT · FILING: BEDBUGS
    (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
    Class BOpen
    Jun 16, 2025
    REMOVE ENCUMBRANCE · EGRESS
    § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES HOUSEHOLD ITEMS AT BALCONY AT BUILDING FRONT AT FIRE ESCAPE, 4th STORY
    Class AOpen
    Jun 4, 2025
    FILE ANNUAL BEDBUG REPORT · FILING: BEDBUGS
    (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
    Class COpen
    Jan 23, 2025Apt 15
    MAKE DOORS SELF-CLOSING · EGRESS
    § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 15, 6th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class COpen
    Jul 30, 2024Apt 12
    TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
    § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 30 SQ. FT AT EAST AND WEST WALLS AND CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 12, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH
    Class COpenRENT IMPAIRING
    Jun 4, 2024Apt 14
    NO GAS · KITCHEN AND KITCHENETTES
    § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE AT KITCHEN. LOCATED AT APT 14, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST
    Class COpenRENT IMPAIRING
    Jun 4, 2024Apt 10
    NO GAS · KITCHEN AND KITCHENETTES
    § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE AT KITCHEN. LOCATED AT APT 10, 4th STORY, 1st APARTMENT FROM NORTH AT EAST
    Class BOpen
    May 28, 2024Apt 7
    ABATE THE NUISANCE · MAINTENANCE
    § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPRATED LOCK INSTALLED AT ENTRANCE DOOR TO ROOM LEADING TO THE FIRE ESCAPE WINDOW IN THE 2nd ROOM FROM EAST LOCATED AT APT 7, 3rd STORY, APARTMENT AT NORTH
    Class COpenRENT IMPAIRING
    May 28, 2024Apt 6
    NO GAS · KITCHEN AND KITCHENETTES
    § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE AT KITCHEN AT APT. 6 LOCATED AT APT 6, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
    Class COpenRENT IMPAIRING
    May 28, 2024Apt 9
    NO GAS · KITCHEN AND KITCHENETTES
    § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE AT KITCHEN AT APT. 9 LOCATED AT APT 9, 4th STORY, 1st APARTMENT FROM WEST AT NORTH
    Class AOpen
    Apr 1, 2024
    FILE ANNUAL BEDBUG REPORT · FILING: BEDBUGS
    (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
    Class AOpen
    Mar 15, 2023
    FILE ANNUAL BEDBUG REPORT · FILING: BEDBUGS
    (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
    Class COpen
    Oct 14, 2022
    RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED
    § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS PANE AT UPPER AND LOWER SASH WINDOW AT THE 5TH STORY AT PUBLIC HALL
    Class COpen
    Oct 14, 2022
    RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED
    § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS PANE AT UPPER AND LOWER SASH WINDOW AT THE 6TH STORY AT PUBLIC HALL
    Class COpen
    Oct 14, 2022
    RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED
    § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS PANE AT UPPER AND LOWER SASH WINDOW AT THE 4TH STORY AT PUBLIC HALL
    Class COpen
    Oct 14, 2022
    RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED
    § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE THE SKLYLIGH
    Class COpen
    Oct 14, 2022
    RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED
    § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS PANE AT UPPER AND LOWER SASH WINDOW AT THE 3RD STORY AT PUBLIC HALL
    Class BOpen
    Jun 28, 2022
    REMOVE ACCUMULATION OR RUBBISH · CLEANING
    § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE SOUTH COURT
    Class COpen
    Jun 15, 2022
    REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRERETARDING CEILING AND WEST WALL AT 1st PUBLIC HALL BULKHEAD FROM NORTH AT WEST, 6th STORY
    Class BOpenRENT IMPAIRING
    Jun 15, 2022
    REMOVE ENCUMBRANCES · EGRESS
    § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AT 1st PUBLIC HALL BULKHEAD FROM NORTH AT WEST, 6th STORY
    Class COpen
    Jun 15, 2022
    MAKE DOORS SELF-CLOSING · EGRESS
    § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT 1st PUBLIC HALL BULKHEAD FROM NORTH AT WEST, 6th STORY
    Class AOpen
    Jun 15, 2022
    PAINT · PAINTING
    § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND WEST WALL AT 1st PUBLIC HALL BULKHEAD FROM NORTH AT WEST, 6th STORY
    Class BOpen
    Jun 15, 2022
    REMOVE ACCUMULATION OR RUBBISH · CLEANING
    § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE SOUTH YARD, 1st STORY
    Class AOpen
    Feb 15, 2022
    FILE ANNUAL BEDBUG REPORT · FILING: BEDBUGS
    (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
    Class AOpen
    Apr 1, 2021
    FILE ANNUAL BEDBUG REPORT · FILING: BEDBUGS
    (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
    Class BOpen
    May 11, 2020
    REMOVE ENCUMBRANCE · EGRESS
    § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES HOUEHOLD ITEMS AT 5TH STORY BALCONY, FRONT STACK AT FIRE ESCAPE
    Class BOpen
    Feb 27, 2020
    REMOVE ENCUMBRANCE · EGRESS
    § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES FLOWER POT AT 3RD STORY BALCONY, FRONT STACK AT FIRE ESCAPE
    Class BOpenRENT IMPAIRING
    Feb 27, 2020
    REMOVE ENCUMBRANCES · EGRESS
    § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF RUBBISH BINS AT PUBLIC HALL, 1st STORY
    Class COpen
    Dec 16, 2019
    POST BOILER ROOM ACCESS NOTICE · HEAT AND HOT WATER
    § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM AT OR NEAR MAILBOX AT PUBLIC HALL, 1st STORY
    Class COpen
    Dec 16, 2019
    PROVIDE ACCESS TO BOILER ROOM · HEAT AND HOT WATER
    § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LEADING TO BOILER ROOM LOCKED AT PUBLIC HALL, 1st STORY
    Class AOpen
    Oct 7, 2019
    POST GAS LEAK NOTICE · POSTING/SIGNAGE
    § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORY
    Class AOpen
    Oct 7, 2019
    POST HOUSING INFORMATION GUIDE NOTICE · POSTING/SIGNAGE
    § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY
    Class BOpen
    Oct 7, 2019
    REPAIR · MAINTENANCE
    § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER SASH WINDOW AT PUBLIC HALL, 3rd STORY
    Class AOpen
    Mar 15, 2019
    PAINT · PAINTING
    § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AND WALLS. AT PUBLIC HALL, 1st STORY
    Class BOpen
    Mar 15, 2019
    REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
    § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AT PUBLIC HALL, 1st STORY
    Class BOpen
    Feb 6, 2019
    PROVIDE · MAINTENANCE
    § 27-2005 ADM CODE PROVIDE SECURITY IN THE EVENT OF A POWER OUTAGE BY MEANS OF AN ACCEPTABLE MECHANICAL HEAVY DUTY LOCK AND LATCH SET AT STREET ENTRANCE DOOR TO BUILDING
    Class BOpenRENT IMPAIRING
    Feb 6, 2019
    REMOVE ENCUMBRANCES · EGRESS
    § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF GARBAGE RECEPTACLES STORED AT PUBLIC HALL, 1st STORY
    Class AOpen
    Feb 6, 2019
    STORAGE OF GARBAGE CANS · COLLECTION OF WASTE
    § 27-2021 ADM CODE PROVIDE PLACE WITHIN THE BUILDING FOR THE STORAGE OF WASTE RECEPTACLES AND DISINFECT SAME REGULARLY.
    Class COpenRENT IMPAIRING
    Feb 6, 2019
    REMOVE ILLEGAL FASTENING · EGRESS
    § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CONSISTING OF AN UNACCEPTABLE ELECTROMAGNETIC LOCKING DEVICE INSTALLED AT STREET ENTRANCE DOOR TO BUILDING
    Class AOpen
    Jun 29, 2018
    POST HOUSING INFORMATION GUIDE NOTICE · POSTING/SIGNAGE
    § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY
    Class COpen
    Jun 29, 2018
    ABATE THE NUISANCE · MAINTENANCE
    § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF GARBAGE STORED UNDER STAIRS AT PUBLIC HALL, 1st STORY
    Class COpen
    Jun 29, 2018
    RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED
    § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS PANE AT LOWER WINDOW SASH AT FIRE ESCAPE WINDOW WEST WALL AT PUBLIC HALL, 3rd STORY
    Class COpenRENT IMPAIRING
    Jun 29, 2018
    REMOVE ILLEGAL FASTENING · EGRESS
    § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CONSISTING OF AN UNACCEPTABLE ELECTROMAGNETIC LOCKING DEVICE INSTALLED AT STREET ENTRANCE DOOR TO BUILDING
    Class COpen
    Jun 29, 2018
    PROVIDE · MAINTENANCE
    § 27-2005 ADM CODE PROVIDE SECURITY IN THE EVENT OF A POWER OUTAGE BY MEANS OF AN ACCEPTABLE MECHANICAL HEAVY DUTY LOCK AND LATCH SET AT STREET ENTRANCE DOOR TO BUILDING
    Class COpen
    Jun 29, 2018
    POST BOILER ROOM ACCESS NOTICE · HEAT AND HOT WATER
    § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM KEY NOT ON PREMISES AT PUBLIC HALL, 1st STORY
    Class AOpen
    Jun 29, 2018
    POST SIGN INDICATING NAME AND ADDRESS OF JANITOR, ETC. · POSTING/SIGNAGE
    § 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORY
    Class AOpen
    Jun 29, 2018
    POST GAS LEAK NOTICE · POSTING/SIGNAGE
    § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORY
    Class COpenRENT IMPAIRING
    Dec 14, 2017
    FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN · EGRESS
    § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN, DEFECTIVE AND/OR MISSING SECONDARY MEANS OF EGRESS DEFECTIVE - BROKEN 11TH TREAD FROM BOTTOM AT 3RD STORY FIRE ESCAPE STAIRS AT BUILDING NORTH
    Class AOpen
    Oct 17, 2017
    PAINT METAL · PAINTING
    § 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALL STORIES, ALL BALCONIES AND ALL COMPONETS BUILDING FRONT AT FIRE ESCAPE, SECTION AT EAST
    Class BOpen
    Oct 17, 2017
    PROVIDE · MAINTENANCE
    § 27-2005 ADM CODE PROVIDE SECURITY IN THE EVENT OF AN POWER OUTAGE BY MEANS OF AN ACCEPTABLE MECHANICAL HEAVY DUTY LOCK AND LATCH SET AT BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORY
    Page 1 of 2